H
d
Typical Characteristics
Cell Type CR17450HE-R
Specifications
Nominal Capac ity
Nominal Voltage
Standard Discharge Current
D
Max. Discharge Current
Temperature Range
Weight
Dimensions
Nominal capacity is determined to an end voltage of 2.0V when the battery is
*1
allowed to discharge at a standard current level at 23oC.
Current value is determined to be the level at which 50% of the nominal
*2
capacity is obtained with an end voltage of 2.0V at 23
Current value for obtaining 1.0V cell voltage when pulse is applied for
*3
15seconds at 50% discharge depth at 23
*1
2000mAh
3V
5mA
Continuous
Pulse
*2
*3
1500mA
3500mA
-40
℃~85℃
22g
D 17.0mm
H 45.0mm
d7mm
o
C.
o
C.
Discharge Characteristics of CR17450HE-R
3.5
3.0
2.5
2.0
Cell Voltage(V)
1.5
1.0
-20oC
o
-30
C
o
-40
C
0
10
20
30
40
Duration(minute)
23oC
50
60
Discharge Characteristics of CR17450HE-R
3.5
3.0
2.5
2.0
Cell Voltage(V)
1.5
1.0
-30
o
-40
C
0
30
-20
o
C
60
o
C
90
Duration(minute)
120
150
23oC
70
Load: 1A
80
Load: 500mA
180
Discharge Characteristics of CR17450HE-R
3.5
3.0
2.5
2.0
Cell Voltage(V)
1.5
90
100
1.0
o
-40
C
0
-20oC
-30oC
20
40
60
Duration(minute)
23oC
80
Load: 750mA
100
120
140
160
Discharge Characteristics of CR17450HE-R
3.5
3.0
2.5
2.0
Cell Voltage(V)
1.5
210
240
1.0
0
o
-40
C
30
60
90
o
-20
o
-30
C
120
150
Duration(minute)
C
180
210
23oC
Load: 400mA
240
270
300
330
360