Typical Characteristics
Cell Type CR14500
Specifications
Nominal Capacity
Nominal Voltage
Standard Discharge Current
D
d
Max. Di scharge Current
Temperature Range
Weight
Dimensions
H
Nominal capacity is determined to an end voltage of 2.0V when the battery is
*1
allowed to discharge at a standard current level at 23oC.
Current value is determined to be the level at which 50% of the nominal
*2
capacity is obtained with an end voltage of 2.0V at 23
Current value for obtaining 1.0V cell voltage when pulse is applied for
*3
15seconds at 50% disc harge depth at 23
*1
1650mAh
3V
10mA
1500mA
3500mA
-40
℃〜60℃
Continuous
*3
Pulse
*2
17g
D14mm
H50mm
d6.3mm
o
C.
o
C.
Pulse Discharge Characteristics of CR14500
3.5
3.0
2.5
2.0
Cell Voltage(V)
1.5
1.0
0 200 400 600 800 1000 1200 1400 1600 1800
Number of Cycles
23℃
-20℃
Discharge Characteristics of CR14500
3.5
60℃
3.0
2.5
2.0
Cell Voltage(V)
1.5
1.0
23℃
-20℃
0 10 20 30 40 50 60 70 80
Duration(hour)
1.2A 3s on / 7s off
Initial
Load: 100ohm
Initial
Discharge Characteristics of CR14500
3.5
3.0
2.5
2.0
Cell Voltage(V)
1.5
1.0
0 10 20 30 40 50 60 70 80
23℃
0℃
Duration (minute)
Discharge Characteristics of CR14500
3.5
60℃
3.0
2.5
2.0
Cell Voltage(V)
1.5
1.0
23℃
-20℃
0 20 40 60 80 100 120 140 160
Duration(hour)
Load: 3 watt
Initial
Load: 200ohm
Ini tia l