Special Functions
■When “SPO1” is input, all special functions are reset.
■When “SPOO is input, all special functions are cancelled, and the start condition for TV power is changed to the
standby start condition, meaning that the picture will not appear even when the mains ON/OFF switch ~ is set at the
on position. To turn on the TV set from the standby mode, press the Power ON/OFF~,Programme UP/DOWN @ or
Programme Selector ~ key.
“SP31” is used to set a limit for the maximum volume level while keeping the current preset programme position in
memory.
When “SP31” is entered, the volume output at the time of entering the code is placed in the memory as the maximum
volume level. In other words, with this code it is possible to set the maximum volume at your preference. Entering this
code automatically suppresses the preset function, so that even if the preset button is pressed, the preset mode will
remain inactive.
(1)Set the disirable volume level using the LEVELQ key,
~~.’.’.’.~,,, ,,, ... ,,, ,,, ,,, ,,,, ,
LEVEL
‘m
-
SOUND
11111111-----”
(2) Input “SP31”.
The volume level set in this
procedure will be memorized
as the maximum volume level.
To cancell “SP 31”, input “SP 30”.
When “SP 50” is entered, the start condition of the TV power is set to the standby start condition, meaning that the picture
will not appear even when the Mains ON/OFF switch @ is set at the on position(The TV set remains in standby mode).
To return the TV’s power start condition to its original condition(normal start condition), input “SP51”.
When “SP 61” is entered, the auto shut off function is suppressed.
AUTO SHUT OFF
(Refer to page 4)
To cancell “SP61”, input “SP60”.
–9–