ELECTRIC VRF
GAS DRIVEN VRF
COMMERCIAL SPLIT SYSTEMS
ROOM AIR CONDITIONERS
HEATING SOLUTIONS
GAS DRIVEN VRF
ELECTRIC VRF
ROOM AIR CONDITIONERS
CO
2
ECO HEATING SYSTEM
Contact your local SANYO distributor for brochures on all other ranges of air conditioning and heating solutions
Indicates conformation
with EC Directives
SANYO reserves the right to make any variation in specication to the equipment described or to withdraw or replace products
without prior notication or public announcement. All descriptions, illustrations, drawings and specications in this publication
are given in good faith, but are intended to present only general particulars and shall not form any part of the contract. For full
installation details, please contact your SANYO distributor.
ISO 9001: 2001
ISO 14001: 2001
Certicate Number: ECOOJ0303-33
Electric VRF
The cooling and heating capacities are based on the following conditions:
Cooling: Indoor temperature 27˚C DB/19˚C WB, Outdoor temperature 35˚C DB/24˚ C WB.
Heating: Indoor temperature 20˚C DB, Outdoor Temperature 7˚C DB 6˚C WB.
Rating Conditions
www.sanyoaircon.com
SANYO Air Conditioners. The natural choice. SANYO Air Conditioners. The natural choice.
ECOi_VRF_V1_2009
Page 2
1
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
2
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
ECOi - 2 and 3 pipe electric VRF systems
L3 L4
H2
H1
L2
Ln
L1
0
5
10
15
20
25
30
35
40
8HP 10HP
ECOi system capacity
12HP 14HP 16HP 18HP 20HP 22HP 24HP - 48HP
13
16
19
23
26
29
33
36
40
Number of indoor units
Since its formation in 1958, SANYO Air Conditioners has been at the forefront of innovation with its market-leading research and development program. From the world’s rst heat pump air conditioner in 1960 to the rst 3 pipe VRF system in 1989, SANYO continues to deliver leading technology combined with the reliability and customer service that you would expect from a global brand like SANYO.
Benets
Ease of installation
R410A has a higher operating pressure with a lower pressure loss than previous refrigerants. This enables smaller pipe sizes to be used and allows reduced refrigerant charges.
Simple to design
SANYO recognise that designing, selecting and preparing a professional VRF quotation can be a time consuming and costly process, especially as it is often also a speculative exercise. So we have designed proprietary software which is quick and easy to use and produces a full schematic layout of pipework and controls, as well as a full materials list and performance data.
Easy to position
The compact design of the ECOi outdoor units means that they t into a standard lift and are easy to handle and position when on site. The small footprint and modular appearance of the units ensure a cohesive appearance to an installation.
O-coil temperature control
SANYO ducted units oer the unique advantage of being able to oer o-coil temperature coil as standard. This allows designers to select units using an o coil temperature between 7°C and 22°C. This allows room environments to be cooled without subjecting its occupants to cold drafts or uncomfortable conditions. This is achieved without any extra controls or wiring to each unit.
Easy to control
A wide variety of control options are available to ensure that the ECOi system provides the user with the degree of control that they desire, from simple room controllers through to state of the art BMS controls.
Simple to commission
Simple set-up procedure including automatic addressing of connected indoor units. Conguration settings can be made from an outdoor unit or via a remote controller.
Accurate capacity control
To ensure that the compressor capacity is matched to building load as accurately and eciently as possible, SANYO has designed its range of 2 and 3 way ECOi systems to operate with DC inverter and high-eciency xed speed compressors. The system selects the most ecient compressor to operate by dynamically monitoring the building load and choosing the best compressor combination to run.
Easy to maintain
Each system allows the use of prognostic and diagnostic controls routines, from refrigerant charge control through to complex fault code diagnostics, all designed to reduce the speed of maintenance calls and unit down time.
Lower running and life cycle costs
SANYO ECOi VRF systems are amongst the most ecient VRF systems on the market, oering COPs in excess of 4.0 at full load conditions. The system is also designed to make sure that we reduce the running cost of each system by using our unique road map control routine to ensure that the most ecient combination of compressors are running at any one time. Improved defrost sequencing also reduces running cost by defrosting each outdoor coil in turn when conditions allow.
Wide selection and connectability
With 15 indoor model styles available, ECOi systems are the ideal choice for multiple small capacity indoor unit installations, with the ability to connect up to 40 indoor units to systems of 24HP or greater.
Flexible pipe length
Category Item Description Max length (m)
Allowable pipework length
Allowable height dierence
L1
L2-L3
L3 L4 Ln Maximum length of each distribution joint 30
L1+L3+L4 Maximum total pipe run length 300
H1
H2 Maximum dierence between indoor units 15
Maximum pipe run in one direction Actual length 150
Dierence between maximum length and minimum length from the rst distribution joint
When outdoor unit installed higher 50
When outdoor unit installed lower 40
Equivalent length 175
40
Page 3
3
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
4
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
Unique SANYO benets
New PAC2 System Design Software
SANYO-Installation cost saving design
Solenoid Valve Box
Industry’s Smallest – 147mm High
• Brazed connections
• Requires only 1 Fixing for mounting
• No transmission wiring at SVK
• No mains power wiring at SVK
• Comes inclusive with lead connection to indoor unit
Saves the cost of local isolators and additional electrical wiring
SANYO-Intelligent on site learning
Compressor Road Map Control
• Measures the average saturated suction temperature from the
fan coil units
• Measures the suction pressure and temperature entering the
outdoor unit
Designing a system for VRF (ECOi and GHP) and PACi Commercial Split Systems has never been easier
SANYO has identied the importance of ever-increasing demands for fast and accurate responses to customer requests in our industry. More and more emphasis is being placed upon energy-eciency in our marketplace. The ability to calculate cooling/heating loads and produce information of actual design conditions is a major advantage to any architect, consultant, contractor or end user.
SANYO understands the ever-changing and demanding industry we are in and we are pleased to announce the launch of the next generation of our system design software program. The new advanced PAC2 system design software has been customised to make any selection and design process as quick and easy as possible. The software features a version of AC Calc Lite. This allows small building loadings to be accurately calculated and directly imported into the PAC2 software.
The design package utilises system wizards and import tools to enable both simple and complex systems to be created. In addition, the system will allow outdoor and indoor units to be dragged and dropped on an interactive desktop. This allows users to create everything from realistic oor plans with detailed piping and wiring schematics to send out with quotations, through to installation guidance drawings.
The new PAC2 system software can be used for all SANYO ECOi, GHP and PACi systems.
Features include:
• AC Calc Lite (included in the package)
• Easy to use system wizards
• Auto piping and wiring features
• Converted duties for conditions and pipework
• Auto CAD (DXF) export
• Detailed wiring and pipework diagram
• Calculates the best combination of compressors to run
• Targets inverter compressor at 30 – 80% (most ecient)
Reduces the running cost of the system
SANYO-Comfort control Air Discharge Temperature Control
• Available on U indoor ducted units
• Discharge air at below 10°C is uncomfortable and can cause
draughts due to cold air dumping
0
• Air o temperature can be controlled between 7
C - 220C
Guaranteed user comfort
Refrigerant Volume “self check” procedure
ECOi 2 & 3WAY systems have an inbuilt self judgement mode to indicate the present system refrigerant volume.
From the outdoor unit you can start the self judgement mode, after completion (approx 30mins) the LED display’s the results.
No Control
LED 1 LED 2
Judgment mode Blinking Blinking
Normal ON ON
Insucient gas Blinking OFF
Overcharge OFF Blinking
Judgment not possible Blinking alternately
SANYO Solution
The new PAC2 system software can be used for all SANYO ECOi, GHP and PACi systems.
It ensures unit eciency, avoids refrigerant wastage and assists with F-Gas complince.
Page 4
5
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
6
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
ECOi Mini 4-6HP 2 Way Inverter Heat Pump VRF Systems
Actual length: 150m
*
2
(Equivalent length: 175m)
System difference of
elevation: 50m *
1
Difference in elevation between indoor units: 15m
*1: 40m if the outdoor unit is below the indoor unit. *2: Total length of pipe: no more than 300m
ECOi 2 Way - features at a glance
SANYO’s policy of product development continues with the expansion of the ECOi Mini, the 2 pipe heat pump small VRF system specically designed for the European market.
Oering between 11kW and 16kW cooling capacity in 3 sizes and up to 9 indoor units connected, the ECOi Mini sets new standards of performance and exibility.
Utilising R410A and DC inverter technology, SANYO oers VRF to a new and growing market.
Forming a new key part of the SANYO VRF line up, the ECOi Mini is compatible with the same indoor units and controls of the electric and gas powered VRF range.
Features at a glance
• Single phase or three phase power supply
• One AMP start current
• DC inverter technology combined with R410A for excellent
eciency
• COP of up to 4.34
• Diversity ratio 50-130%
• 150m pipe runs
• Cooling operation to -10°C
• Full range of indoor units and control options
• Compact outdoor unit 1230x940x340mm
Highest COPs - lowest running costs
HP 4 5 6
EER Cooling 4.06 3.66 3.39
COP Heating 4.34 4.10 3.84
Wide operating range
The operating range for heating operation is to -20°C, the cooling range is to -10°C. The remote controller temperature setting oers a range from 16°C to 30°C.
ECOi 2 Way is a high-performance heat pump system with excellent energy-saving features, designed for creating a comfortable environment when either heating or cooling is required.
• Heat pump systems oer heating or cooling
• Single footprint size for all unit capacities
• DC inverter technology combined with R410A for excellent
eciency
• System conguration from 8HP to 48HP
• Diversity ratio 50-130%
• Industry low outdoor unit sound levels: from 54.5dB(A)
• Quiet mode oers a further 3dB(A) reduction
• Extended pipe runs of up to 150m
• COPs up to 4.10
• Heating capacity to -20°C
• Connectability of 40 indoor units from 24HP upwards
• Units available from 8-16HP as single units
Extended compressor life
The compressor running time is monitored and optimised by a microcomputer to ensure that there is no imbalance in the operation times of compressors on the same refrigerant circuit.
Longer piping means greater installation area
Reducing the refrigerant volume by reducing piping size has extended the piping actual length to 150m (175m equivalent piping length).
HP 4 5 6
Model name Power supply 230V, 1 phase, 50/60Hz/400, 3 phase, 50/60Hz Cooling capacity kW 11.20 14.00 15.50 Heating capacity kW 12.50 16.00 17.60 EER Cooling 4.06 3.66 3.39 COP Heating 4.34 4.10 3.84
Cooling
Electric rating
Heating
Recommended fuse size (motor rated)
Dimensions (H/W/D) mm 1,230x940x340 Net weight kg 104 Air circulation m Refrigerant amount at shipment kg 3.5
Piping connection
Operating sound normal mode Operating sound quiet mode 48.0 49.0 Ambient temperature operating
range Maximum number of indoor units 6 8 9 * Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details.
* Please refer to tube sizing charts for pipe selections and pipe length parameters.
Running
A 14.1/4.34 19.6/6.02 23.4/7.18
amperes
Power input kW 2.76 3.83 4.57
Running
A 14.7/4.52 19.9/6.13 23.4/7.19
amperes
Power input kW 2.88 3.90 4.58
1ph 3ph 25/16 32/16
3
/min 100
Inches
Gas
(mm) Inches
Liquid
(mm)
dB(A)
Cooling -10°C DB +43°C DB Heating -20°C DB +15°C DB
SPW-CR365GXH56B/SPW-CR365GXH8B SPW-CR485GXH56B/SPW-CR485GXH8B SPW-CR605GXH56B/SPW-CR605GXH8B
5/8 (15.88) 3/4 (19.05)
3/8 (9.52)
51.0 52.0
Save on piping cost
R410A with low pressure loss enables smaller pipe sizes. This means reduced piping space, improved workability at the site and reduced piping material costs.
Extended operating range - better output at lower temperatures
The operating range for heating has been extended to
-15°C. The remote controller temperature setting for heating operation has also been extended from 16°C to 30°C.
Higher COPs - lower running costs
HP 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
EER Cooling 3.74 3.54 3.50 3.45 3.38 3.63 3.54 3.51 3.49 3.44 3.43 3.41 3.38 3.50 3.47 3.47 3.45 3.42 3.43 3.40 3.38
COP Heating 4.10 4.10 3.91 3.91 3.79 4.06 4.06 3.97 3.96 3.88 3.84 3.85 3.79 4.00 3.94 3.89 3.91 3.86 3.83 3.83 3.79
Page 5
7
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
8
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
ECOi 2 Way Heat Pump VRF Inverter Systems
890
(Top plate dimension)
890
(Top plate dimension)
890
(Top plate dimension)
890
(Top plate dimension)
890
(Top plate dimension)
890
(Top plate dimension)
890
(Top plate dimension)
1880
100
200
18 to 32 HP
34 to 48 HP
8 to 16 HP
790
(Installation hole pitch)
790
(Installation hole pitch)
920
(
Installation
hole pitch)
1780
(Installation hole pitch)
950 (Max. dimension)
890
(Top plate dimension)
890
(Top plate dimension)
790
(Installation hole pitch)
920
(
Installation
hole pitch)
950 (Max. dimension)
2870
100
200200
100
790
(Installation hole pitch)
790
(Installation hole pitch)
2770
(Installation hole pitch)
790
(Installation hole pitch)
920
(
Installation
hole pitch)
950 (Max. dimension)
HP
Model
8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
C0705DXHN8 C0905DXHN8 C1155DXHN8 C1305DXHN8 C1405DXHN8
10 C0905DXHN8 10 C0905DXHN8 12 C1155DXHN8 14 C1305DXHN8 8 C0705DXHN8
Power supply Cooling capacity kW Heating capacity kW EER Cooling kW COP Heating kW
Running
Cooling
Electric rating
Heating
amperes
Power
input
Running
amperes
Power
input
Recommended fuse sizes (motor rated)
Dimensions (H/W/D) mm Net weight kg Air circulation m3/min
Piping connection
Gas
Liquid
Balance
Inches (mm)
Operating sound normal mode
Operating sound
dB(A)
quiet mode Ambient temperature
operating range
Cooling Heating
Maximum number of indoor units
A
kW
A
kW
22.40 28.00 33.50 40.00 45.00 50.40 56.00 61.50 68.00 73.00 78.50 85.00 90.00 96.00 101.00 107.00 113.00 118.00 124.00 130.00 135.00
25.00 31.50 37.50 45.00 50.00 56.50 63.00 69.00 76.50 81.50 87.50 95.00 100.00 108.00 113.00 119.00 127.00 132.00 138.00 145.00 150.00
3.74 3.54 3.50 3.45 3.38 3.63 3.54 3.51 3.49 3.44 3.43 3.41 3.38 3.50 3.47 3.47 3.45 3.42 3.43 3.40 3.38
4.05 4.06 3.91 3.91 3.79 4.06 4.06 3.97 3.96 3.88 3.84 3.85 3.79 4.00 3.94 3.89 3.91 3.86 3.83 3.83 3.79
10.1/9.6/9.3 13.3/12.7/12.2 16.2/15.4/14.8 20.0/19.0/18.3 23.0/21.8/21.0 23.4/22.3/21.5 26.6/25.4/24.4 29.5/28.1/27 33.3/31.7/30.5 36.3/34.5/33.2 39.2/37.2/35.8 43.0/40.8/39.3 46.0/43.6/42.0 46.6/44.4/42.7 49.6/47.2/45.4 52.5/49.9/48.0 56.3/53.5/51.5 59.3/56.3/54.2 62.2/59.0/56.8 66.0/62.6/60.3 69.0/65.4/63.0
5.99 7.90 9.58 11.60 13.30 13.90 15.80 17.50 19.50 21.20 22.90 24.90 26.60 27.40 29.10 30.80 32.80 34.50 36.20 38.20 39.90
10.4/9.9/9.5 13.1/12.4/12.0 16.2/15.4/14.8 19.9/18.9/18.2 22.8/21.6/20.9 23.5/22.3/21.5 26.2/24.8/24.0 29.3/27.8/26.8 33.0/31.3/30.2 35.9/34.0/32.9 39.0/37.0/35.7 42.7/40.5/39.1 45.6/43.2/41.8 46.1/43.7/42.2 49.0/46.4/44.9 52.1/49.4/47.7 55.8/52.9/51.1 58.7/55.6/53.8 61.8/58.6/56.6 65.5/62.1/60.0 68.4/64.8/62.7
6.17 7.75 9.60 11.50 13.20 13.90 15.50 17.70 20.70 22.60 23.10 26.10 28.00 29.30 31.20 30.60 34.70 34.20 37.10 37.90 42.00
32 40 32x2
1887×890×890 (+60) 1887×1880×890 (+60) 1887×1880×890 (+60) 1887×2870×890 (+60) 245 295 345 540 590 640 640 690 929 985 1035 150 160 180 200 220 160+150 160+160 180+160 200+160 220+160 220+180 220+220 200+160+160 220+160+160 220+180+160 220+200+160 220+220+160 220+220+180 220+220+200 220+220+220
3/4 (19.05) 7/8 (22.22) 1 1/8 (28.58) 1 3/8 (34.92) 1 5/8 (41.27)
3/8 (9.52) 1/2 (12.7) 5/8 (15.88) 3/4 (19.05)
54.5 55.0 56.0 60.0 61.0 58.0 58.5 61.5 62.0 62.5 63.5 64.0 62.5 63.0 64.5 65.0 65.5 66.0
51.5 52.0 53.0 57.0 58.0 55.0 55.5 58.5 59.0 59.5 60.5 61.0 59.5 60.0 61.5 62.0 62.5 63.0
13 16 19 23 26 29 33 36 40
* Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details. * Please refer to tube sizing charts for pipe selections and pipe length parameters.
10 C0905DXHN8
10 C0905DXHN8 10 C0905DXHN8
1x40 1x32
16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 14 C1305DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 10 C0905DXHN8 12 C1155DXHN8 14 C1305DXHN8 16 C1405DXHN8 10 C0905DXHN8 10 C0905DXHN8 12 C1155DXHN8 14 C1305DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8
10 C0905DXHN8 10 C0905DXHN8 10 C0905DXHN8 10 C0905DXHN8 10 C0905DXHN8 12 C1155DXHN8
14 C1305DXHN8
16 C1405DXHN8
380/400/415V - 3 phase/50,60Hz
1x40 1x32
2x40
2x32 1x40
1x32 2x40
3x40
1/4 (6.35)
-10°C DB +43°C DB
-20°C DB +15°C DB
System example for ECOi 2 Way
Outdoor unit
Connection
System limitations
Maximum number of combined outdoor units 3 Maximum HP of combined outdoor units 48HP Maximum number of connectable indoor units 40 Indoor/outdoor unit capacity ratio 50-130% Maximum actual piping length 150m Maximum level dierence (when outdoor unit is lower) 50(40)m Maximum total piping length in one direction 300m
SANYO make it possible to link outdoor units together for a large capacity (48HP)
If indoor/outdoor units need ser vicing, a ball valve (optional) cuts o non-operational units to let other units stay running.
Since all piping is concentrated into one pipe shaft, you can minimise piping space and construction labour.
Concentration
Addition
If your indoor capacity load changes in the future, it’s easy to add on both indoor and outdoor units using the same piping.
(2 Way version i llustrated)
Dimensions of unit combinations (ECOi 2 Way and 3 Way)
Indoor unit
Indoor unit
Page 6
9
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
10
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
8HP ~ 48HP
Cooling: -10˚C DB ~ 43˚C DB Heating: -20˚C WB ~ 15˚C WB
ECOi 3 Way - features at a glance
Solenoid Valve Kit
ECOi 3 Way is one of the most advanced VRF heat recovery systems available. Not only oering high-eciency and performance for simultaneous heating and cooling, its sophisticated design makes installation and maintenance much easier.
• Simultaneous heating and cooling for total control
Solenoid Valve Kit
Fully-automatic simultaneous Cooling/Heating operation and heat recovery
System Example
• Any design and layout can be used in a single system
• Cooling operation is possible down to an outdoor
temperature of -10°C
• Single footprint size for all unit capacities (8-16HP)
• DC inverter technology combined with R410A for
excellent eciency
• System conguration from 8HP to 48HP
• Diversity ratio 50-130%
• Sound levels: from 54.5dB(A)
• Quiet mode oers a further 3dB(A) reduction
• Extended pipe runs of up to 150m
• COPs to 4.1
• Provides cooling down to -10°C ambient
• Connectability of 40 indoor units from 24HP upwards
Extended operating range - better output at lower temperatures
The operating range for heating has been extended to
-20°C. The remote controller temperature setting for heating operation has also been extended from 16°C to 30°C.
Up to max. 40 indoor units
3 Way ECOi Multi enables simultaneous heating and cooling operation by each solenoid valve kit.
[Cooling] [Cooling] [Cooling][Stop][Heating] [Heating]
Liquid pipe medium-temperature, medium-pressure liquid pipe
Discharge pipe high-temperature, high-pressure gas pipe
Solenoid Valve Kit ATK-RZP56BG ATK-RZP160BG
Same operation
Suction pipe low-temperature, low-pressure gas pipe
There is improved performance at lower ambient conditions due to SANYO’s unique wrap-around outdoor unit coil design and active defrost management.
Higher COPs - lower running costs
HP
EER Cooling
COP Heating 4.09 3.95 3.81 3.91 3.79 4.01 3.96 3.88 3.92 3.84 3.8 3.85 3.79 3.93 3.88 3.84 3.88 3.84 3.81 3.83 3.79
8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
3.78 3.45 3.41 3.45 3.38 3.57 3.46 3.44 3.45 3.41 3.4 3.41 3.38 3.45 3.41 3.42 3.42 3.4 3.41 3.40 3.38
Up to 5 indoor units with individual remote control can be connected o 1 SVK box.
Box dimensions: L 166mm X 147mm X 217mm
Timer remote controller
RCS-TM80BG
Page 7
11
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C
Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
12
UK Conditions: Cooling Indoor 23˚C DB 50% RH Outdoor 30˚C Heating Indoor 20˚C Outdoor 0˚C Rating Conditions: Cooling Indoor 27˚C DB 19˚C WB Outdoor 35˚C DB 24˚C WB Heating Indoor 20˚C DB Outdoor 7˚C DB 6˚C WB
ECOi 3 Way Heat Recovery VRF Inverter Systems
HP (Combined systems)
Model
Power supply Cooling capacity kW Heating capacity kW EER Cooling kW COP Heating kW
Electric ratings
Recommended fuse sizes (motor rated)
Dimensions (H/W/D) mm Net weight kg Airow m3/min
Piping connection
Operating sound normal mode Operating sound quiet mode Ambient temperature
operating range Maximum number of indoor units * Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details.
* Please refer to tube sizing charts for pipe selections and pipe length parameters.
Cooling
Heating
Discharge
Balance
Gas
Liquid
Cooling Heating
Inches (mm)
Running amperes A
Power input kW
Running amperes A
Power input kW
dB(A)
8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
C0705DZH8 C0905DZH8 C1155DZH8 C1305DZH8 C1405DZH8 8 C0705DZH8
22.40 28.00 33.50 40.00 45.00 50.40 56.00 61.50 68.00 73.00 78.50 85.00 90.00 96.00 101.00 107.00 113.00 118.00 124.00 130.00 135.00
25.00 31.50 37.50 45.00 50.00 56.50 63.00 69.00 76.50 81.50 87.50 95.00 100.00 108.00 113.00 119.00 127.00 132.00 138.00 145.00 150.00
3.78 3.45 3.41 3.45 3.38 3.57 3.46 3.44 3.45 3.41 3.40 3.41 3.38 3.45 3.41 3.42 3.42 3.40 3.41 3.40 3.38
4.09 3.95 3.81 3.91 3.79 4.01 3.96 3.88 3.92 3.84 3.80 3.85 3.79 3.93 3.88 3.84 3.88 3.84 3.81 3.83 3.79
10.0/9.5/9.2 13.7/13.0/12.6 16.6/15.7/15.2 20.0/19.0/18.3 23.0/21.8/21.0 23.8/22.6/21.8 27.3/26.0/25.0 30.2/28.7/27.7 33.6/31.9/30.8 36.5/34.7/33.5 39.4/37.5/36.1 43.0/40.8/39.4 45.9/43.6/42.1 47.5/45.1/43.5 50.5/48.0/46.3 53.0/51.0/49.0 57.0/54.0/52.0 60.0/57.0/55.0 63.0/60.0/58.0 66.0/63.0/60.0 69.0/65.0/63.0
5.93 8.12 9.82 11.59 13.31 14.10 16.20 17.90 19.70 21.40 23.10 24.90 26.60 27.80 29.60 31.30 33.00 34.70 36.40 38.20 39.90
10.3/9.8/9.4 13.5/12.8/12.3 16.6/15.8/15.2 19.9/18.9/18.2 22.8/21.6/20.9 23.9/22.6/21.8 26.8/25.5/24.6 30.0/28.5/27.5 33.3/31.6/30.5 36.2/34.4/33.1 39.3/37.3/36.0 42.6/40.5/39.0 45.6/43.3/41.7 46.9/44.6/43.0 49.7/47.2/45.5 53.0/50.0/48.0 56.0/54.0/52.0 59.0/56.0/54.0 63.0/59.0/57.0 65.0/62.0/60.0 68.0/65.0/63.0
6.11 7.97 9.84 11.51 13.19 14.10 15.90 17.80 19.50 21.20 23.30 24.70 26.40 27.50 29.10 31.00 32.70 34.40 36.20 37.90 39.60
32 40 32x2
1,887x890x890 (+60) 1,887x1,880x890 (+60) 1,887x1,880x890 (+60) 1887x2870x890 (+60)
290 340 580 630 680 920 970 1020
150 160 180 200 220 150+160 160+160 160+180 160+200 160+220 180+220 200+220 220+220 160+160+200 160+160+220 160+180+220 160+200+220 160+220+220 180+220+220 200+220+220 220+220+220
3/4 (19.05) 7/8 (22.22) 1 1/8 (28.58) 1 3/8 (34.92) 1 5/8 (41.27) 5/8 (15.88) 3/4 (19.05) 7/8 (22.22) 1 1/8 (28.58) 1 3/8 (34.92)
3/8 (9.52) 1/2 (12.7) 5/8 (15.88) 3/4 (19.05)
54.5 55.0 56.0 60.0 61.0 57.8 58.0 58.5 57.8 60.1 60.4 61.0 61.5 60.8 61.3 61.5 62.0 62.4 62.6 63.0 63.3
51.5 52.0 53.0 57.0 58.0 54.8 55.0 55.5 54.8 57.1 57.4 58.0 58.5 57.8 58.3 58.5 59.0 59.4 59.6 60.0 60.3
13 16 19 23 26 29 33 36 40
10 C0905DZH8 10 C0905DZH8 12 C1155DZH8 14 C1305DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 10 C0905DZH8 10 C0905DZH8 12 C1155DZH8 14 C1305DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8
10 C0905DZH8 10 C0905DZH8 10 C0905DZH8 10 C0905DZH8 12 C1155DZH8 14 C1305DZH8 16 C1405DZH8 10 C0905DZH8 10 C0905DZH8 10 C0905DZH8 10 C0905DZH8 10 C0905DZH8 12 C1155DZH8 14 C1305DZH8 16 C1405DZH8
380/400/415V - 3phase/50Hz
1x40 1x32
3/8 (9.52)
-10°C DB +43°C DB
-20°C DB +15°C DB
2x40
14 C1305DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8 16 C1405DZH8
2x32 1x40
1x32 2x40
3x40
ATK-RZP56BG and ATK-RZP160BG
Industry’s smallest changeover boxes - fewer locating problems
The SANYO solenoid valve kit is only 147mm high (without the removable bracket) and takes its power from the indoor unit, saving the cost of an additional supply.
• No additional power supply required
• Single mounting x point
• 2 sizes avaliable (up to 5.6kW and 7.5 to 16kW)
Dimensions ECOi 2 Way and 3 Way (8-16 HP)
Solenoid Valve Kit
Page 8
13
14
VRF Indoor Unit Range for ECOi and GHP
Wider operation
Comfortable auto -ap control
Model size 7 9 12 16 18 22 25 36 48 60 76 96 Wireless remote control
Capacity kW
Capacity
X Type Semi-Concealed Cassette
XM Type Semi-Concealed
US Type Concealed Duct
U Type Concealed Duct
DR Type Concealed Duct
K Type Wall Mounted Unit
BTU/h
25,48 type
Cooling 2.2 2.8 3.6 4.5 5.6 6.4 7.3 Heating 2.5 3.2 4.2 5.0 6.3 7.0 8.0 Cooling 7,500 9,600 12,000 15,000 19,000 22,000 25,000 Heating 8,500 11,000 14,000 17,000 21,000 24,000 27,000
76,96 type
SPW-X075XH
SPW-XDR74GXH56B
Panel
PNR-XD484GHAB
SPW-XM075XH
Panel
PNR-XM185
SPW-US075XH SPW-US095XH SPW-US125XH SPW-US165XH SPW-US185XH
SPW-U075XH
SPW-UR74GXH56B
SPW-K075XH SPW-K095XH SPW-K125XH
SPW-X095XH
SPW-XDR94GXH56B
Panel
PNR-XD484GHAB
SPW-XM095XH
Panel
PNR-XM185
SPW-U095XH
SPW-UR94GXH56B
SPW-X125XH
SPW-XDR124GXH56B
Panel
PNR-XD484GHAB
SPW-XM125XH
Panel
PNR-XM185
SPW-U125XH
SPW-UR124GXH56B
SPW-X165XH
SPW-XDR164GXH56B
Panel
PNR-XD484GHAB
SPW-XM165XH
Panel
PNR-XM185
SPW-U165XH
SPW-UR164GXH56B
SPW-X185XH
SPW-XDR184GXH56B
Panel
PNR-XD484GHAB
SPW-XM185XH
Panel
PNR-XM185
SPW-U185XH
SPW-UR184GXH56B
SPW-X255XH
SPW-XDR254GXH56B
Panel
PNR-XD484GHAB
SPW-U255XH
SPW-UR254GXH56B
SPW-DR254GXH56B
10.6 14.0 16.0 22.4 28.0
11.4 16.0 18.0 25.0 31.5 36,000 47,800 54,600 76,400 95,500 39,000 54,600 61,500 85,300 107,500
SPW-X365XH
SPW-XDR364GXH56B
Panel
PNR-XD484GHAB
SPW-U365XH
SPW-UR364GXH56B
SPW-DR364GX-
H56B
SPW-X485XH
SPW-XDR484GXH56B
Panel
PNR-XD484GHAB
SPW-U485XH
SPW-UR484GXH56B
SPW-DR484GX-
H56B
Automatic restart function for power failure
SPW-X605XH
SPW-XDR604GXH56B
Panel
PNR-XD484GHAB
SPW-U605XH
SPW-UR604GXH56B
Self-diagnosing function
SPW-DR764GXH56B SPW-DR964GXH56B
Built-in infra red
sensorl
Automatic fan operation
Separately installed
infra red sensor
Air Sweep
Mild dry
Built-in drain pump
Functions
KR Type Wall Mounted Unit
T Type Ceiling­Mounted Unit
FTR Type Floor/Ceiling Mounted Units
FUR Type Floor/Ceiling Slim Concealed Duct
FR Type Floor Standing Unit
FMR Type Concealed Floor Standing Unit
ADR Type Semi-Concealed Cassette 1-Way Air Discharge
SR Type Semi-Concealed Cassette 2-Way Air Discharge
LDR Type Semi-Concealed Slim Cassette
SPW-KR164GXH56B SPW-KR184GXH56B SPW-KR254GXH56B
SPW-T125XH
SPW-TDR124GXH56B
SPW-FTR74EXH56B SPW-FTR94EXH56B SPW-FTR124EXH56B SPW-FTR164EXH56B SPW-FTR184EXH56B SPW-FTR224EXH56B
SPW-FUR74EXH56B SPW-FUR94EXH56B SPW-FUR124EXH56B SPW-FUR164EXH56B SPW-FUR184EXH56B SPW-FUR224EXH56B
SPW-FR74GXH56B SPW-FR94GXH56B SPW-FR124GXH56B SPW-FR164GXH56B SPW-FR184GXH56B SPW-FR254GXH56B
SPW-FMR74GXH56B SPW-FMR94GXH56B
SPW-ADR74GXH56B
Panel
PNR-AD124GHB
SPW-SR74GXH56B
Panel
PNR-S124GHB
SPW-ADR94GXH56B
Panel
PNR-AD124GHB
SR94GXH56B
Panel
PNR-S124GHB
SPW-LDR94GXH56B
Panel
PNR-LD254GHAB
SPW-FMR124GXH56B SPW-FMR164GXH56B SPW-FMR184GXH56B SPW-FMR254GXH56B
SPW-ADR124GXH56B
Panel
PNR-AD124GHB
SR124GXH56B
Panel
PNR-S124GHB
SPW-LDR124GXH56B
Panel
PNR-LD254GHAB
SPW-T165XH
SPW-TDR164GXH56B
SR164GXH56B,
Panel
PNR-S124GHB
SPW-LDR164GXH56B
Panel
PNR-LD254GHAB
SPW-T185XH
SPW-TDR184GXH56B
SR184GXH56B
Panel
PNR-S124GHB
SPW-LDR184GXH56B
Panel
PNR-LD254GHAB
SPW-T225XH
SPW-TDR254GXH56B
SPW-SR254GXH56B
Panel
PNR-S253GHANB
SPW-LDR254GXH56B
Panel
PNR-LD254GHAB
SPW-T365XH
SPW-TDR364GXH56B
SPW-T485XH
SPW-TDR484GXH56B
GU Type Total Heat Exchanger
SPW-GU055XH SPW-GU075XH SPW-GU105XH
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Page 9
15
16
Room Control Systems Overview Centralised Control Systems Overview
A wide variety of control options to meet the requirements of dierent customers.
Operation system Individual control systems Timer operation
Requirements
External appearance
Type, model name
Number of indoor units which
can be controlled
Use limitations
Connectable
indoor unit
Function
Normal
operation
Timer wired
remote controller
RCS-TM80BG
1 group, 8 units 1 group, 8 units 1 group, 8 units
Up to 2 units can be
connected per group.
4 series indoor unit 4 series indoor unit 4 series indoor unit 4 series indoor unit
Operation from
each seat
Wireless remote
controller
RCS-SH80BG.WLB RCS-TH80BG.WLB
RCS-BH80AG.WLB
RCS-TRP80BG.WLB
RCS-SH1BGB
Up to 2 units can be
connected per group.
Simple operation
Simplied remote
controller
RCS-KR1EG
Up to 2 units can be
connected per group.
weekly programme
Power supply from the system
When there is no system
controller, connection is
possible to the T10 terminal
Daily and
Schedule timer
SHA-TM64AGB
64 groups,
max. 64 units
controller.
of an
indoor unit.
External appearance
Type, model name
Number of indoor units which can be
controlled
Use limitations
Connectable
indoor unit
Function
Centralised control systems
Operation with various
function from central
station
Only ON/OFF operation from
central station
Simplied charge ratio for each tenant
Touch screen panel
Personal computer
(eld supply)
Web
application
System controller
SHA-KC64AGB
64 groups,
max. 64 units
Up to 10 units can be
connected to one system.
Main unit/sub unit (1 main
unit + 1 sub unit) connection
is possible.
Use without remote controller
is possible.
4 series indoor unit 4 series indoor unit 4 series indoor unit 4 series indoor unit
ON/OFF controller
SHA-KC16KAGB
16 groups,
max. 64 units
Up to 8 units (4 main units + 4
sub units) can be connected
to one system.
Use without remote controller
is impossible.
Intelligent controller
SHA-KT256EG
64 units x 4 systems,
max. 256 units
A communication adaptor
(SHA-KA128AGB) must be
installed for three or more
systems.
Communication adaptor
SHA-KA128AGB
2 systems,
max. 128 units
Maximum 500 indoor units
(128 per communication
adaptor)
ON/OFF
Mode setting
Fan speed setting
Temperature setting
Air ow direction
Permit/Prohibit switching - - - -
Weekly programme
*1 Setting is not possible when a remote control unit is present. (Use the remote control for setting.)
*1 *1 *1
- -
-
-
-
-
-
ON/OFF
Mode setting
Fan speed setting
Temperature setting
Air ow direction
Permit/Prohibit switching
Weekly programme
*1 *1
-
-
-
-
-
*1
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WBRating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Page 10
17
18
GU Type Heat Exchanger
CFR Units
SANYO’s new heat recovery ventilation system allows total control via a system network whilst modulating the temperature and humidity of incoming air supply.
• Integration of heat recovery ventilation and DX coil
technology for optimum air temperature control
• The DX coil can be connected to all ECO & GHP outdoor units
• Easy to clean lter
• Compact design
• Filter option
• 3 Way: Solenoid valve kit is required for each unit
• 2 Way: RAP kit is required for each unit
Controller Options
Timer remote controller
Wireless remote controller
Simplied remote controller
Installation example
Humidication
(optional)
The CFR-PHE unit structure is constructed from Aluzink frame work and galvanised steel with 20 mm thick re resistant acoustic insulation, reducing both weight and sound levels to a minimum. The system is supplied with ducted spigots which can be positioned either at the front or side of the unit to ease installation.
• High eciency heat exchanger
• Easy to clean lters
The high eciency low pressure loss total heat exchanger is made of specially treated paper to enable the unit to be as ecient as 76% during normal operation. This allows system to recover both latent and sensible heat.
DX coil Heat exchanger
Exhaust air
Fresh air
RCS-TM80BG
RCS-BH80BG.WL
Supply air
RCS-KR1EG
Return air
Indoor unit specications
Model Name SPW-GU055XH SPW-GU075XH SPW-GU105XH
Air circulation (H) m³/h 500 750 1,000 Power source 220/230/240V, 1 phase - 50 Hz Fresh air load
treatment capacity
Enthalpy exchange eciency
Temp exchange eciency 75
Equivalent cooling capacity
Power input
Running current
Fan motor
Sound pressure level (C/H) db(A) 46 (Cooling), 47 (Heating) 47 (Cooling), 48 (Heating) 48 (Cooling), 49 (Heating)
Dimensions
Piping connections
Connection duct diameter mm 250 300 Net weight kg 134 153 168 The values in ( ) for the external static pressure and operating sound are for use of booster cable. *1: Heat recovery capacity by heat exchanger. Data subject to change without notice.
UK Cooling kW 5.3 (1.7)*¹ 8.2 (2.6)*¹ 10.7 (3.4)*¹ UK Heating kW 6.5 (2.3)*¹ 9.8 (3.5)*¹ 12.6 (4.6)*¹
UK Cooling % 59 UK Heating % 67
kW 3.6 5.6 7.3
BTU/h 12,000 19,000 25,000 Cooling kW 0.532 0.737 0.798 Heating kW 0.532 0.737 0.798 Cooling Amps 2.4 3.2 3.5 Heating Amps 2.4 3.2 3.5 Type Sirocco fan External static pressure-return air Pa 183 (170) 221 (188) 135 (88) External static pressure-supply air Pa 205 (182) 264 (218) 176 (137) Output kW 0.28 (4P)x2 0.35 (4P)x2
Height mm 425 450 Width mm 1785 1903 Depth mm 1000 1120 1220 Liquid (are) mm (inches) 6.35 (1/4) Gas (are) mm (inches) 12.7 (1/2) Drain piping VP-25
Indoor unit specications
Model CFR/ CFR-PHE 33 55 110 175 220
Nominal air ow * m3/hr 300 620 920 1580 1850 External Static Pressure pa 45 55 65 70 77 Sound Pressure ** dB(A) 43 51 50 53 52 Fans Power in Watts 184 340 294 700 700 Absorbed power A 0.75 1.8 2.2 4.4 4.8 Fan speeds no 1 3 Insulation Class F Electrical supply v/ph/htz 230/1/50 Bioxigen Elements (PHE only) Number of elements 2 X C 2 X F Electrical supply v/ph/htz 230/1/50 Power in Watts 8 8 8 8 8 Filter EU3 Paper Heat Exchanger CFR-PHE Temperature Eciency heating *** 76% 74% 72% 68% 73% Temperature Eciency cooling **** 62% 60% 58% 54% 59%
* Nominal air ow ** Sound pressure 1.5 mts from the unit in free eld *** Data referred to -5
**** Data referred to 32
0
C 80% RH OAT room condition 200C 50% RH
0
C 50% RH OAT room condition 260C 50% RH
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB