Split System Submittal Data
System: 42TW72R Indoor/Outdoor: THW4272R/C4272R
Ceiling Suspended Air Conditioner
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
General Data (at 230V)
Power V/PH/Hz 230/208/1/60
Circuit Ampacity
Fuse Size, Max.
Compressor
No. used
R.L. Amps - L.R.
Crankcase Heater
Outdoor Unit
Fan type
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
No. Motors
CFM
F.L. Amps
(A) 15-40 Indoor-Outdoor
(A) 15-40 Indoor-Outdoor
DC Rotary Inverter
1
(A) 18.1-31.0
(W) -
Propeller
18-7/64-2
Direct Inverter
(RPM) 8 - 830
(W) 2-90
(High) 3531
(A) 19.7
Approval:
Date:
Construction:
Unit #:
Drawing #:
Refrigerant
Lbs. - R410a (outdoor unit)
Control
Connection
Line Length, Max
Lift Difference, Max
Line Size
Line Size
Dimensions
Indoor Unit
Outdoor Unit
R410A
7.94
Electric Expansion Valve
Flare
165
50 (Outdoor lower), 100 (Outdoor higher)
(in. O.D. Discharge) 3/8”
(in. O.D. Suction) 5/8”
(in.) H x W x D
(Uncrated) 9-7/16 x 62-1/32 x 26-3/8
(Crated) 12-15/32 x 66-1/16 x 31-1/6
(Uncrated) 48-7/16 x 37 x 13-3/8
(Crated) 52-3/8 x 39-31/32 x 16-3/32
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
No. Poles
No. Motors
CFM
Indoor Sound Rating
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
Tube Size
Drain Connection Size
Aluminum Fin & Copper Pipe
Slit Plate - Inner Rifl ed
2-12.7
(sq.ft.) 11.62
(in.) 3/8”
Centrifugal
5-29/32 - 4
3 & Auto
(RPM, High) 4-1099
(W) 1-100
(HI/Med/Lo) 1130/950/775
(Hi) (dB-A) 44
(A) 0.8
Aluminum Fin & Copper Tube
Slit Plate - Inner Rifl ed
3-14.9
(sq.ft.) 3.51
(in.) 9/32”
(in.) (1-1/4)
Weight
Net
Shipping
Shipping Volume
Performance Data @ ARI Standard Conditions (230V)
Cooling
Total Capacity
Sensible Capacity
Latent Capacity
SEER
Dehumidification
Amps
Power Inputs
Outdoor Sound Rating
(cu.ft.) 14.8 19.5
(Pints/H) 12.6
(A) 21.1/23.3
(dB-A) 53
Indoor Outdoor
(lbs.) 84 220
(lbs.) 97 240
Indoor Outdoor
(BTU/H) 39,000 (9,500-39,000)
(BTU/H) 23,560
(BTU/H) 15,440
(W) 4,140/4,140
15.6
Dimens ions
Feature
Controls
Remote Controller
Temperature Control
Timer
Night Setback
Air Louver
Power Failure Automatic Restart
Self-Diagnosis
Air Filter
(Horizontal) Manual
(Vertical) Automatic
Microprocessor
LCD Wired Type, Temp. Sensor Built In
IC Thermostat
72HR, ON/OFF
Built-In
Built-In
Built-In
Washable, Anti-Mold
Option
Refrigerant Line Set
Fresh Air Intake
Condensate Drain Pump
Wireless Remote Controller
Non-Removeable Remo-con Bracket
Operating Range
Indoor Air Intake Temp. Outdoor Air Intake Temp.
Cooling
Maximum 95F DB/71F WB 115F DB
Minimum 67F DB/57F WB 0F DB
Available
Knock-Out
Available
Available
Available
Sanyo Commercial Solutions
A Division of SANYO North America
1300 Michael Drive
Wood Dale, IL 60191 USA
www.sanyohvac.com