![](/html/df/dfc0/dfc0bc8d0d44642fe367d8e11fd4b1bd64a942e90d846fd5ce0a4d918a43c9b2/bg1.png)
INSTALLATION, MAINTENANCE & OPERATION
GUIDE
MODEL S300FX-GX
WHOLE HOUSE
HEPA/UV AIR PURIFIER
ITE M # 101275
![](/html/df/dfc0/dfc0bc8d0d44642fe367d8e11fd4b1bd64a942e90d846fd5ce0a4d918a43c9b2/bg2.png)
SAFETY CONSIDERATIONS
Installation and servicing or equipment can be hazardous. Only
trained and qualified service personnel should install, repair, or
service equipment.
Untrained personnel can perform basic maintenance functions
such as changing lamps and filters. All other operations should be
performed by trained service personnel. When working on equipment,
observe precautions in the literature, tags and labels attached to the
unit or accessory, and other safety precautions that may apply.
Follow all safety codes.Wear safety glasses and work gloves
WARNING
Before installing the S300FX-GX HEPA/UV Purifier or performing
maintenance or service on the air purifier, disconnect power cord
from the unit.
WARNING
Never expose eyes or skin to ultra-violet light from any source. The
S300FX-GX must be unplugged before performing maintenance or
service. Personal injury may result.
WARNING
Do not touch lamp glass without gloves. Reduced performance of
lamp may result. Clean lamp after handling.
WARNING
Lamp contains a small quantity of mercury. If a lamp breaks, clean
and dispose of with care.
WARNING
Use only specified replacement Lamps with your Sanuvox Purifier.
Use of an incorrect Lamp can result in damage to the Purifier
and/or Lamp.
![](/html/df/dfc0/dfc0bc8d0d44642fe367d8e11fd4b1bd64a942e90d846fd5ce0a4d918a43c9b2/bg3.png)
INSTALLATION GUIDE
LIMITED PARTS WARRANTY
THREE-YEAR WARRANTY — This SANUVOX
TECHNOLOGIES INC. product is warranted to be
free from defects in material and workmanship
under normal use and maintenance for a
period of 3 years from the date of original
installation and for a period of 3 years (2 years
for commercial) for the UV Lamp.
A new or remanufactured part to replace the
defective part will be provided without charge
for the part itself, through a qualified servicing
SANUVOX TECHNOLOGIES INC. dealer or
distributor, PROVIDED the defective part is
returned to our distributor. The replacement
part assumes the unused portion of the
warranty
TABLE OF CONTENTS
1. GETTING STARTED
1.1 Unpacking and inspection 3
1.2 Technical data 4
2. INSTALLATION GUIDE
2.1 Planning the installation 5
2.2 Type of installation: Return to Return 6
2.3 Type of installation: Stand-Alone 6
2.4 Installing the unit 7
2.5 Installing the UV Lamp 10
3. OWNER’S OPERATION GUIDE
3.1 General Operating Information 11
4. MAINTENANCE GUIDE
4.1 Changing filters 12
4.2 Cleaning unit 12
4.3 Troubleshooting 12
4.4 Electrical Wiring Diagram 12
1.1. UNPACKING AND INSPECTION
BOX CONTENT INCLUDES:
• S300FX-GX HEPA/UV AIR PURIFIER
• Power cord, 5 FT
• Plenum seal, 7.5 FT
• Screws, (16) 8 x 32 x 1/2"
• Template
• Ultraviolet UVC/UVV Lamp
J Type 10.5" (266.7 mm)
• Pre-Filter
• HEPA Filter
SANUVOX - M ODEL S 300FX- GX - 3
![](/html/df/dfc0/dfc0bc8d0d44642fe367d8e11fd4b1bd64a942e90d846fd5ce0a4d918a43c9b2/bg4.png)
17"
432 mm
30"
770 mm
4"
97 mm
13"
327 mm
12"
305 mm
Stage 1
Stage 2
17"
432 mm
30"
770 mm
4"
97 mm
13"
327 mm
31"
795 mm
17"
432 mm
30"
770 mm
4"
97 mm
13"
327 mm
12"
305 mm
Stage 1
Stage 2
Power Connection
12"
305 mm
Stage 1
Stage 2
17"
432 mm
30"
770 mm
4"
97 mm
17"
432 mm
30"
770 mm
4"
97 mm
13"
327 mm
17"
432 mm
30"
770 mm
4"
97 mm
Power Connection
12"
305 mm
Stage 1
Stage 2
17"
432 mm
30"
770 mm
4"
97 mm
INSTALLATION GUIDE
1.2. TECHNICAL DATA
SPECIFICATIONS
MODEL S300FX-GX
Filtration Stage 1 Prefilter
Filtration Stage 2 HEPA filter
Weight 33 Lbs. (15kg)
Plenum Mount 16" x 3.5" (406mm x 89mm)
Port Openings
Collar Mount 8" (203mm) Round*
Port Openings
Installation t ype Plenum, Floor Mount*
or Wall Mount**
Electrical Supply 120 VAC @ 60 Hz
Power Consumption 270 W
Certification
Air flow data 220-300 CFM
UV Lamp Proprietary UV-C /UV-V
“J” Lamp
* Installation requires inlet / outlet 8" round collars
(sold in pairs). Part# MSCCOL1
** Installation requires inlet / outlet louvers
(sold individually) . Part# MSCLOU1
C
CSA
US
IMPORTANT INFORMATION
Sanuvox Technologies Inc. reserves the right
to modify the product without prior notice.
Please consult local authorities as to whether
the installation requires the services of a
certified technician or electrician.
DIMENSIONS AND CLEARANCE
INSTAL LAT ION
RETURN AIR PLENUM INSTALLATION
Front View
31"
795 mm
RETURN AIR PLENUM AND STAND ALONE INSTALLATIONS*
WITH COLLAR MOUNT KIT
Front View
8"
203 mm
Side View - Clearance
13"
327 mm
Side View - Clearance
Stage 1
Stage 2
12"
305 mm
Back View
17"
432 mm
Back View
Power Connection
4"
97 mm
4"
97 mm
30"
770 mm
4 - SANUVOX - M ODEL S 300FX- GX
31"
795 mm
13"
327 mm
Stage 1
Stage 2
12"
305 mm
17"
432 mm
30"
770 mm
![](/html/df/dfc0/dfc0bc8d0d44642fe367d8e11fd4b1bd64a942e90d846fd5ce0a4d918a43c9b2/bg5.png)
INSTALLATION GUIDE
2.1 PLANNING THE INSTALLATION
SPECIAL CONSIDERATION
FOR INTEGRATED SYSTEM INSTALLATION
• Verify clearance on the ductwork to mount
the unit using the Forced Air Heating/
Cooling system
• Respect the Minimum clearance
requirements for maintenance and service
The HEPA/UV air purier is a versatile appliance with multiple installations conguration. It is
recommended to take your time in planning the installation.
A number of installations follow for HEPA/UV air purier applications:
• Return duct to Return duct integrated with the forced air HVAC system.
• Central draw points using a dedicated duct system.
• Consult Sanuvox for other special applications.
• Electrical power requirements
• Interaction between the HEPA/UV air purier
unit and other mechanical devices.
2.2 TYPE OF INSTALLATION: RETURN TO RETURN
DUCTING FLAIR SYSTEM INSTALLATION
The HEPA/UV air purier system is designed to
install directly onto the return air plenum of the
HVAC system. This installation eliminates the
need to externally duct the HEPA/UV air purier
to the plenum system. With this installation, it
is recommended that you run the fan on your
forced air system continuously to maximize its
cleaning ability.
TIPS TO INSTALLER
The HEPA/UV air purier does not replace
the filter from the HVAC system. Regular
maintenance of this filter is necessary for
proper performance of the system.
DUCTING FLAIR SYSTEM
(MOUNTED ON DUCT)
Return
Air Plenum
To living
space
OPTIONAL COLLAR SYSTEM
(MOUNTED ON WALL)
To living
space
OPTIONAL MOUNTING COLLAR SYSTEM
INSTALLATION
Using Part Number: Collars1, the HEPA/UV air
purier can be converted to use 8 inch round
collars for applications that require ducting.
The kit includes two, 8 inch round collars, two
mounting brackets for wall or floor mounting,
installation guide and fasteners.
Forced Air Heating /Cooling System
Return
Air Plenum
Forced Air Heating /Cooling System
INSTALLATION SHOULD BE PERFORMED BY A CERTIFIED PROFESSIONAL.
Consult your HVAC product manufacturer if the usage of this product will affect the performance of
your forced air heating/cooling system.
SANUVOX - M ODEL S 300FX- GX - 5