Sanuvox S300FX, S300GX Installation, Maintenance & Operation Manual

INSTALLATION, MAINTENANCE & OPERATION
GUIDE
MODEL S300FX-GX
WHOLE HOUSE
HEPA/UV AIR PURIFIER
ITE M # 101275
Installation and servicing or equipment can be hazardous. Only trained and qualified service personnel should install, repair, or service equipment.
Untrained personnel can perform basic maintenance functions such as changing lamps and filters. All other operations should be performed by trained service personnel. When working on equipment, observe precautions in the literature, tags and labels attached to the unit or accessory, and other safety precautions that may apply.
Follow all safety codes.Wear safety glasses and work gloves
WARNING
Before installing the S300FX-GX HEPA/UV Purifier or performing maintenance or service on the air purifier, disconnect power cord from the unit.
WARNING
Never expose eyes or skin to ultra-violet light from any source. The S300FX-GX must be unplugged before performing maintenance or service. Personal injury may result.
WARNING
Do not touch lamp glass without gloves. Reduced performance of lamp may result. Clean lamp after handling.
WARNING
Lamp contains a small quantity of mercury. If a lamp breaks, clean and dispose of with care.
WARNING
Use only specified replacement Lamps with your Sanuvox Purifier. Use of an incorrect Lamp can result in damage to the Purifier and/or Lamp.
INSTALLATION GUIDE
LIMITED PARTS WARRANTY
THREE-YEAR WARRANTY — This SANUVOX TECHNOLOGIES INC. product is warranted to be free from defects in material and workmanship under normal use and maintenance for a period of 3 years from the date of original installation and for a period of 3 years (2 years for commercial) for the UV Lamp.
A new or remanufactured part to replace the defective part will be provided without charge for the part itself, through a qualified servicing SANUVOX TECHNOLOGIES INC. dealer or distributor, PROVIDED the defective part is returned to our distributor. The replacement part assumes the unused portion of the warranty
TABLE OF CONTENTS
1. GETTING STARTED
1.1 Unpacking and inspection 3
1.2 Technical data 4
2. INSTALLATION GUIDE
2.1 Planning the installation 5
2.2 Type of installation: Return to Return 6
2.3 Type of installation: Stand-Alone 6
2.4 Installing the unit 7
2.5 Installing the UV Lamp 10
3. OWNER’S OPERATION GUIDE
3.1 General Operating Information 11
4. MAINTENANCE GUIDE
4.1 Changing filters 12
4.2 Cleaning unit 12
4.3 Troubleshooting 12
4.4 Electrical Wiring Diagram 12
1.1. UNPACKING AND INSPECTION
BOX CONTENT INCLUDES:
• S300FX-GX HEPA/UV AIR PURIFIER
• Power cord, 5 FT
• Plenum seal, 7.5 FT
• Screws, (16) 8 x 32 x 1/2"
• Template
• Ultraviolet UVC/UVV Lamp J Type 10.5" (266.7 mm)
• Pre-Filter
• HEPA Filter
SANUVOX - M ODEL S 300FX- GX - 3
17"
432 mm
30"
770 mm
4"
97 mm
13"
327 mm
12"
305 mm
Stage 1
Stage 2
17"
432 mm
30"
770 mm
4"
97 mm
13"
327 mm
31"
795 mm
17"
432 mm
30"
770 mm
4"
97 mm
13"
327 mm
12"
305 mm
Stage 1
Stage 2
Power Connection
12"
305 mm
Stage 1
Stage 2
17"
432 mm
30"
770 mm
4"
97 mm
17"
432 mm
30"
770 mm
4"
97 mm
13"
327 mm
17"
432 mm
30"
770 mm
4"
97 mm
Power Connection
12"
305 mm
Stage 1
Stage 2
17"
432 mm
30"
770 mm
4"
97 mm
INSTALLATION GUIDE
1.2. TECHNICAL DATA
SPECIFICATIONS
MODEL S300FX-GX
Filtration Stage 1 Prefilter
Filtration Stage 2 HEPA filter
Weight 33 Lbs. (15kg)
Plenum Mount 16" x 3.5" (406mm x 89mm) Port Openings
Collar Mount 8" (203mm) Round* Port Openings
Installation t ype Plenum, Floor Mount*
or Wall Mount**
Electrical Supply 120 VAC @ 60 Hz
Power Consumption 270 W
Certification
Air flow data 220-300 CFM
UV Lamp Proprietary UV-C /UV-V
“J” Lamp
* Installation requires inlet / outlet 8" round collars
(sold in pairs). Part# MSCCOL1
** Installation requires inlet / outlet louvers
(sold individually) . Part# MSCLOU1
C
CSA
US
IMPORTANT INFORMATION
Sanuvox Technologies Inc. reserves the right
to modify the product without prior notice. Please consult local authorities as to whether the installation requires the services of a certified technician or electrician.
DIMENSIONS AND CLEARANCE
INSTAL LAT ION
RETURN AIR PLENUM INSTALLATION
Front View
31"
795 mm
RETURN AIR PLENUM AND STAND ALONE INSTALLATIONS*
WITH COLLAR MOUNT KIT
Front View
8"
203 mm
Side View - Clearance
13"
327 mm
Side View - Clearance
Stage 1
Stage 2
12"
305 mm
Back View
17"
432 mm
Back View
Power Connection
4"
97 mm
4"
97 mm
30"
770 mm
4 - SANUVOX - M ODEL S 300FX- GX
31"
795 mm
13"
327 mm
Stage 1
Stage 2
12"
305 mm
17"
432 mm
30"
770 mm
INSTALLATION GUIDE
2.1 PLANNING THE INSTALLATION
SPECIAL CONSIDERATION FOR INTEGRATED SYSTEM INSTALLATION
• Verify clearance on the ductwork to mount the unit using the Forced Air Heating/
Cooling system
• Respect the Minimum clearance
requirements for maintenance and service
The HEPA/UV air purier is a versatile appliance with multiple installations conguration. It is
recommended to take your time in planning the installation.
A number of installations follow for HEPA/UV air purier applications:
• Return duct to Return duct integrated with the forced air HVAC system.
• Central draw points using a dedicated duct system.
• Consult Sanuvox for other special applications.
• Electrical power requirements
• Interaction between the HEPA/UV air purier
unit and other mechanical devices.
2.2 TYPE OF INSTALLATION: RETURN TO RETURN
DUCTING FLAIR SYSTEM INSTALLATION
The HEPA/UV air purier system is designed to
install directly onto the return air plenum of the HVAC system. This installation eliminates the
need to externally duct the HEPA/UV air purier
to the plenum system. With this installation, it is recommended that you run the fan on your
forced air system continuously to maximize its
cleaning ability.
TIPS TO INSTALLER
The HEPA/UV air purier does not replace
the filter from the HVAC system. Regular maintenance of this filter is necessary for proper performance of the system.
DUCTING FLAIR SYSTEM
(MOUNTED ON DUCT)
Return
Air Plenum
To living space
OPTIONAL COLLAR SYSTEM
(MOUNTED ON WALL)
To living space
OPTIONAL MOUNTING COLLAR SYSTEM INSTALLATION
Using Part Number: Collars1, the HEPA/UV air purier can be converted to use 8 inch round
collars for applications that require ducting.
The kit includes two, 8 inch round collars, two
mounting brackets for wall or floor mounting, installation guide and fasteners.
Forced Air Heating /Cooling System
Return
Air Plenum
Forced Air Heating /Cooling System
INSTALLATION SHOULD BE PERFORMED BY A CERTIFIED PROFESSIONAL.
Consult your HVAC product manufacturer if the usage of this product will affect the performance of
your forced air heating/cooling system.
SANUVOX - M ODEL S 300FX- GX - 5