QUATTRO
INSTALLATION
MANUAL
NOTICE
PLEASE SAVE FOR YOUR RECORDS
Serial Number#
Date Installed:
Installed By:
Installers Contact info.:
WARNING
SANUVOX TECHNOLOGIES INC. © 2018
Follow all safety codes.
Wear safety glasses and work gloves.
Questions? Call 1-888-SANUVOX
1-888-SANUVOX www.sanuvox.com
Trouble-Shooting the UV Lamp
QUATTRO
INSTALLATION
MANUAL
Before installing or performing maintenance or service
on the purifier, turn off unit and disconnect from power source.
Electrical shock can cause injury or death. There may be more
than one disconnect switch.
Never expose eyes or skin to ultraviolet light from any source.
The Purifier MUST be DISCONNECTED from power source before
performing maintenance or service. Personal injury may result.
Do not touch Lamp glass without gloves. Reduced performance
of Lamp may result. Clean Lamp after handling.
The UV Lamp contains a small quantity of mercury.
If a Lamp breaks, clean and dispose of with care.
Use only specified replacement Lamps with your Purifier.
Use of an incorrect Lamp can result in damage
to the Purifier and/or Lamp.
UV rays may destroy certain types of filters (polymer or plastic),
please keep unit away from shining directly on plastic.
UV lamp can be disposed/recycled after use as for any other
fluorescent bulb.
RETURN OR SUPPLY PLENUM INSTALLATION
1 Cut a 6¼" W x 22¼" H opening in the duct-work at the desired installation location.
2. OPTIONAL: lnstall the added reflectivity if desired.
3. Adjust the UV Lamp assembly so it will be positioned in the middle of the duct. The arms that support the Lamp assembly
have an adjustable clutch which allows the Lamp and extrusion to be set at a distance from 10 to 15 inches from the backplate.
To adjust the assembly, loosen the clutch by turning it counter-clockwise (see Figure B.). The Lamps and extrusion can then be
positioned to the desired distance from the backplate. Rotate the clutch clockwise to tighten.
4. Place the QUATTRO in the duct opening in the correct position. Mount to duct-work with 12 self taping screws provided.
5. Plug in the power cord.
OPERATION
The QUATTRO has an ON-OFF toggle switch and a circuit breaker located at the bottom of the front cover. To operate, press the toggle
switch to the "ON" position. The switch has a red light to indicate that there is power. If the switch does not illuminate, check the outlet
for power and check the QUATTRO circuit breaker. Start the HVAC fan. The QUATTRO detects airflow with the vacuum switch.
The QUATTRO will only operate when the fan is ON (airflow through the plenum) and there is a pressure differential of at least 0.04 in.
When operating, the LED lights on the front cover will be lit. There are two LED lights corresponding to each of the 4 UV Lamps.
The AMBER LED indicates the UV Lamp is functioning. The RED LED indicates the Ballast is ON. If the UV Lamp is defective, the RED LED
will be lit corresponding to the BALLAST being ON and AMBER LED will be OFF corresponding to Lamp out. If both LED lights are OFF,
the ballast
is not functioning. If none of the 8 LED lights are lit, then there is not enough of a vacuum differential to activate the vacuum switch,
or the vacuum switch is defective.
Fiberglass or paper filter media are recommended for operation of HVAC when filters are exposed to direct line of sight with the ultraviolet
light. Polyester or cotton filters are subject to ultraviolet degradation and are nor recommended.
MAINTENANCE
Disconnect all power before performing any maintenance or service. Lamps need periodic replacement to maintain design specifications.
ln residential applications, replace UV after 3 years of operation. ln commercial applications, replace Lamps after 2 years of operation.
The following UV Lamps are used with the following QUATTRO models:
QUATTRO G: 4 x LMPHGS180 UV Germicidal only
QUATTRO GX: 3 x LMPHGS180 UV Germicidal only + 1 x LMPHGXS180 UV Germicidal / Oxidizing
Other Lamps may plug into the QUATTRO but should not be used.
CHECKING THE UV LAMP
Sanuvox Ultraviolet Lamps are built to the highest standards. If the Red LED (Ballast) is lit and the Amber LED (Lamp) is not lit, it is
important to check the Lamp to insure that it is not a defect in the Lamp Sensing Circuit in the Ballast. This is done by using an
ohmmeter to check the two filaments on the Lamp.
Disconnect the socket from the Lamp.
Placing the probe of the ohmmeter to one of the four pins on the end of the Lamp, touch the other probe of the ohmmeter to each
of the other pins until you find the matching pin. The ohmmeter will read approximately 3 ohms (almost a short). This indicates
that the filament is good. Check the other two pins. If both sets of filaments test OK, the Lamp is functioning. If one or both sets of
filaments read an open circuit (infinity) on resistance, the Lamp is defective.