READ AND FOLLOW ALL INSTRUCTIONS CONTAINED IN THIS MANUAL BEFORE USE.
FAILURE TO COMPLY WITH THESE INSTRUCTIONS MAY RESULT IN PERSONAL
All wiring must be done by a professional and in accordance with national and local electrical codes.
Always wear safety glasses and work gloves for protection.
SANUVOX TECHNOLOGIES INC. | 146, rue Barr, St-Laurent, Quebec, Canada H4T 1Y4
Bio-Wall Max installation manual v5.1 - 2018-06-07
WARNING
INJURIES OR DAMAGED UNIT.
1-888-SANUVOX www.sanuvox.com
2
To e Owner
ank You
Congratulations on the purchase of the Sanuvox UV
Bio-Wall Max air purier. Sanuvox UV air puriers
are the most advanced air purication systems available,
having been proven to destroy up to 99.9999%
of biological and chemical contaminants that circulate
throughout the building or facility. Sanuvox systems have
been tested by the EPA (Environmental Protection Agency),
e National Homeland Security Research Center, Medical
Universities and Independent 3rd Party Laboratories.
Table of Contents
Engineered and assembled in Montreal (Quebec),
Canada, Sanuvox products are carefully craed to deliver
to you the best that UV air purication can oer and
improve your air quality. is new UV Bio-Wall Max air
purier oers many advantages over the previous
version such as: single multi-voltage ballast used for all
models, BMS control/data and distant monitoring,
ballast box air cooling system and availability of a
touchscreen to interface with the control circuit.
About the UV Bio-Wall Max Air Purier ....................... 3
Important Safety Instructions & Warranty ..................... 4
Included in the Box ............................................................ 5
Available Options ............................................................... 6
Models & Replacement Parts .......................................... 14
3
About the UV Bio-Wall Max Air Purier
GENERAL
e Sanuvox UV Bio-Wall Max is specically designed to destroy biological and chemical* contaminants such as mold,
bacteria, viruses, chemicals*, VOCS* and odors* that may be circulated through the HVAC system of the building
or facility.
e Sanuvox UV Bio-Wall Max is installed in the RETURN (preferred) or SUPPLY plenum of the HVAC system
treating the air passing through the air duct. e actual percentage of destruction obtained is based on the duct size,
percentage of fresh air, velocity, the number of passes and specic contaminants to be treated. Depending on these
variables, more than one UV Bio-Wall Max air purier may be required.
For information or recommendations relative to sizing for your specic application, please call Sanuvox at 1-888-SANUVOX.
*For GX models only
SAFETY CONSIDERATIONS
Installation and servicing of air-conditioning and related equipment can be hazardous due to system pressure and
electrical components. Only trained and accredited service personnel should install, repair or service such
equipment.
Untrained personnel can perform basic maintenance functions such as replacing lamps. All other operations should
be performed by trained service personnel. When working on the UV Bio-Wall Max air purier, observe precautions
in the literature, tags, labels attached to the unit and any other safety precautions considered as best practices in the
HVAC industry.
HANDLING CONSIDERATIONS
e UV Bio-Wall Max and its ballast box can be heavy. Make sure proper liing techniques are used when
manipulating those to avoid injuries.
CLEANING CONSIDERATIONS
For optimal air purication performance, the lamps and lamp reector assembly should be kept free of dust / residue
deposit and cleaned regularly using mild soap or alcohol. Always spot test the cleaner to make sure it does not
damage the surface.
For the ballast box, occasionally air blow the interior to keep it clean of dust / residue deposit.
Under no circumstances should water be sprayed or splashed onto the UV Bio-Wall Max air purier.
MAINTENANCE
Replace all UV lamps every 17000 hours (2 years). Refer to part number etched on the lamp or to replacement parts
table at the end of this manual.
4
IMPORTANT SAFETY INSTRUCTIONS
WARNING
Before installing or performing maintenance on the unit, TURN OFF and disconnect unit from power source.
Electrical shock may cause personal injuries or possibly death.
Never expose eyes or skin to ultraviolet light from any source. e UV purier MUST be DISCONNECTED
from power source before performing maintenance of service. Personal injury may result.
Do not touch lamp glass without gloves. Reduced performance of lamp may result. Clean lamp aer handling.
e UV lamp contains a small quantity of mercury. If a lamp breaks, clean and dispose of with care.
Use only specied replacement lamps with your unit. Use of an incorrect lamp can result in damage to the unit
and/or lamp and will also void the warranty.
When applicable local regulations comprises more restrictive installation and/or certication requirements,
the aforementioned requirements prevail on those of this document and the installer agrees to conform to these
at his own expenses.
When performing installation, servicing or cleaning the UV purier, it is recommended to wear safety glasses
and gloves.
NOTICE
UV lamp can be disposed / recycled aer use as any other uorescent lamp. Contact and follow your local and
federal authorities’ specic instructions.
WARRANTY
e warranties applicable to the dierent components included in your purchase are as per the table below:
Component Warranty
UV lamps provided in the UV Bio-Wall Max 2 years or 17,000 hours *whichever comes rst
Ballasts in the UV Bio-Wall Max ballast box 15 years
All other parts of the UV Bio-Wall Max air purier 1 year
Bio Smart Screen (optional) 1 year
5
INCLUDED IN THE BOX
e UV Bio-Wall Max air purier you purchased comprises the following:
Component Qty
UV Bio-Wall Max lamp reector assembly and 10 cable 1
UV Bio-Wall Max ballast box 1
Mounting clips 2
Support anges 4
Support rods 2
Installation Kit 1
- UV Caution Decal
- Maintenance Decal
- Pair of cotton gloves
- Snap bushing