2.4 DO NOT operate the appliance if:
1. Water ceases to ow during use.
2. Water has entered inside the unit because of an incorrectly tted
cover.
3. If the appliance is damaged.
2.5 ISOLATE the electrical and water supplies before removing the cover.
2.6 ISOLATE the electrical and water supplies BEFORE proceeding with
installation or servicing.
2.7 The appliance must be mounted on to a at nished wall surface that
covers the full width and length of the backplate (or on top of the tiles).
2.8 DO NOT tile up to the appliance after xing to the wall.
2.9 The sprayplate must be cleaned when any of its holes become blocked,
otherwise restriction to the ow from the outlet spout will result in
higher temperatures and could also cause the pressure relief device in
the appliance to operate - see 1.1 and 9.2.
2.10 The product is NOT SUITABLE for mounting into steam rooms or
steam cubicles.
2.11 The installation must be carried out in accordance with the relevant
requirements of:
• The appropriate Building Regulations either The Building Regulations,
The Building Regulations (Scotland) or Building Regulations (North
ern Ireland).
• The Water Fittings Regulations or Water Byelaws in Scotland.
CAUTION
2.12 It is recommended that persons who may have difculty understanding
or operating the controls should not be left unattended whilst washing
hands. Special consideration should be given to young children and
persons with reduced physical, sensory or mental capabilities.
2.13 Only use designated entry points for cable and pipe.
PLUMBING
2.14 The plumbing installation must comply with Water Regulations.
2.15 The supply pipe must be ushed to clear debris before connecting to
the hand wash appliance.
2.16 DO NOT solder pipes or ttings within 300mm once the pipework is
located in the appliance, as heat transfer can damage components.
2.17 DO NOT t any form of outlet ow control, as the outlet acts as a vent
for the heater can.
2.18 DO NOT use excessive force when tting the spout xing nut, nger
tightness is sufcient.
2.19 All plumbing connections must be completed and checked for leaks
before making the electrical connections.