Spout
MODEL: 6620BO10
Flush both supply lines before installation. After ushing shut off both supply lines.
6620BO75
Hole size for the spout and handle trim is a minimum of 1¼” and a maximum of 1½”.
Spout Installation
Remove tee connector, tee connector washer, and
A
spout mounting hardware from bottom of spout assembly. Apply a ring of silicone caulking around the center hole on the top of the sink (do not use plumber’s putty which can damage the spout nish).
From the top of the deck, insert the spout’s threaded shank and lift rod through the center hole of the sink or counter surface.
Slip the spout mounting hardware back onto the spout.
B
First the notched rubber washer, then the notched metal
Lift Rod
washer, wing nut, and brass lock nut.
3
4
5
"
3
8
4
"
Make sure the lift rod operates smoothly. Adjust if necessary.
Hand tighten the lock nut.
Rubber washer
Notched rubber washer
Notched metal washer
Wing nut
Brass lock nut
3
"
16
5
3
"
8
2
3
Ø2"
1
4
7
"
16
4
11
"
16
1
"
KEEP THIS INSTRUCTION BOOKLET FOR FUTURE REFERENCE
Important : Please register your product online at www.santecfaucet.com within 30 days of purchase. Santec reserves the right to request additional documents before servicing warranty requests.
01
Align spout and secure to the sink or counter surface by
C
tightening the 2 screws on the wing nut.
Place the tee connector washer into the tee connector and thread the tee connector onto the end of the spout shank. Hand tighten to seal.
Wing nut
Tee connector & Washer
02
Handle
Water supply
line
INLET HOSE
Handle
Handle Installation
HANDLE TRIMS ARE READY FOR SIMPLE DROP-IN INSTALLATION. DO NOT DISASSEMBLE.
Remove the valve body mounting hardware from the
A
valve body.
SANTEC
Fiber washer
Brass lock nut
Rubber washer
Make sure the handle with the “cold” blue label is installed at the right side of the spout (looking from front) and the handle with the “hot” red label at the left side of the spout.
Apply a ring of silicone caulking around the handle hole on the sink or counter top (do not use plumber’s putty which can damage the nish of your faucet).
Slip the valve body’s exible hoses from the top of the sink or counter through the appropriate hole next to the spout. Aim the tee connecting hoses toward the tee connector.
Align the handle lever properly with respect to the spout.
B
From under the basin or counter, hand tighten the brass lock nut and ber washer to the valve body against the counter.
ANTEC
S
Handle Installation
Secure the valve body by tightening the screws
C
attached to the lock nuts.
Loop and connect the exible hoses to the tee.
D
Tighten the nuts provided at the of the hose to avoid leakage.
Connect and tighten the Inlet hoses to the supply lines. Use 1/2” IPS faucet connections, or 3/8” copper piper using compression tting system.
SANTEC
SANTEC
INLET HOSE
Water supply
line
03