![](/html/04/046e/046e4e6686d0ccd04aa98a813219f21c237c576a0d323e5a1f24f5946e14995e/bg1.png)
ITEM NUMBER
3534TX _ _-_ _
MODENA COLLECTION
PRESSURE BALANCED TUB AND SHOWER WITH “TX” CROSS HANDLE
17½”
9¼”
1414
33
22
11
6½”
6”
55
H
C
1414
37/8”
44
88
66
6”
##
Shower head *
1
Shower Arm *
2
99
S
77
1010
1111
T
1212
1313
Shower Flange *
3
Complete TX Cross Handle for Shower *
4
Tub/shower Trim Plate *
5
Complete Wall Mount Tub Spout *
6
Pressure Balanced Tub/Shower Valve
7
Allen Key for Set Screw
8
Aerator Washer
9
Aerator Basket
10
Aerator Housing *
11
Trim Plate Grommet
12
Diverter Knob *
13
PART
DESCRIPTION
PART #
P0274
P0300WD-1
P0300M
00YY-TX
PH-28055
PS-4D00U
PB-3950
PM-033
PM-100
PM-355
P0261
PM-465
P0258
* Please specify the finish when ordering the part.
KEEP THIS INSTRUCTION BOOKLET FOR FUTURE REFERENCE
PAGE 01
![](/html/04/046e/046e4e6686d0ccd04aa98a813219f21c237c576a0d323e5a1f24f5946e14995e/bg2.png)
INSTALLATION INSTRUCTIONS
3534TX _ _
DESCRIPTION
This product is precision engineered to provide satisfactory performance provided it is installed and operated in
accordance with our recommendations contained in this manual. In order to fully enjoy the comfort, safety and the
reliability of your pressure balancing valve, be certain to familiarize yourself with the contents of this manual.
WALL LINE
SPECIFICATIONS AND DIMENSIONS
½”
78"
(1981 mm)
Minimum operating pressure 20 psi
Maximum operating pressure 145 psi
Maximum test pressure 500 psi
Hot and cold water inlets ½" IPS
½”
33"
Shower outlet ½" IPS
Flow capacity 5 USGPM@ 50 psi
Finished wall adjustment : see Illustration B
FLOOR
LINE
INSTALLATION
NOTE: Failure to follow these instructions may cause damage or improper operations and nullify the warranty.
ROUGH IN
- Make sure the water supplies are off.
- Remove all the trim items (plate, handle and flange) before installation.
- Secure the valve firmly against the stud. Make sure the ½" shower outlet is in the up position.
- Make sure to flush or raise grouting on the tiled wall surface.
- Adjust the All Thread depth against the Teflon Washer and Limit Stop.
Screw the All Thread against the Teflon washer until it is pressured gently against each other.
- Tighten firmly the Lock Nut against the Lock Plate.
- Position the valve using the dimension shown in the illustration B.
3.00”
Trim Plate
FLANGE WASHER HANDLE FLANGE
HANDLE BELL
HANDLE
S
All Thread
Stem
Lock Nut
Lock Plate
Diverter Knob
T
Diverter Rod
Diverter Rod O-Ring
ILLUSTRATION B
PAGE 02