Santec 2512YC User Manual

LEAR CRYSTAL COLLECTION 2-HANDLE SHOWER WITH “LA” HANDLES
33
22
11
ITEM NUMBER
2512YC _ _-_ _
##
1
Shower Arm *
2
Shower Flange *
44
3
Complete Crystal Handle for Shower *
4
Complete 2-Handle Shower Valve
5
Hot Cartridge for Shower
6
Cold Cartridge for Shower
7
Regular Adaption Kit for Shower
8
Allen Key
9
* Please specify the finish when ordering the part.
PART
DESCRIPTION
PART #
P0285
P0286
P0287
00YY-YC
P0482
P0418
P0419
PM-3
88
SANTECSANTEC
66
SANTECSANTEC
77
55
99
KEEP THIS INSTRUCTION BOOKLET FOR FUTURE REFERENCE
PAGE 01
INSTALLATION INSTRUCTIONS
FLUSH BOTH SUPPLY LINES BEFORE INSTALLATION
.
AFTER FLUSHING , SHUT OFF BOTH SUPPLY LINES.
MINIMUM HOLE SIZE FOR THE HANDLE TRIMS IS 1 5/8” AND MAXIMUM OF 1 3/4”
INSTALLATION INSTRUCTION
2512 YC _ _
INSTALLING THE VALVE WITHOUT THE TRIM
1- If the valve is installed first without the trim, please leave 2” to 2-1/8” space between the center of the inlet and the finished wall. This will leave enough thread length to be adjusted when the trim is installed.
WARNING: Where tile construction is planned for the finished walls, allow for the extra thickness dimensions when roughing in the valves.
INSTALLING THE VALVE WITH THE TRIM
1- Install the valve onto the wall with 2” space between the center of the valve inlet and the finished wall. Screw the handle flange with the flange washer onto the handle bell and tighten it firmly.
2” ~ 2 1/8
center of IN port
FLANGE WASHER
HANDLE FLANGE
ALL THREAD
finished wall
HANDLE BELL
STEM
HANDLE
2- Screw the handle bell, flange and washer onto the all thread, press them firmly against the wall and mark the position. Remove the handle bell, flange and washer and cut off the excess thread. Reinsert the handle bell, flange and washer onto the all thread.
ALL THREAD
STEM
PAGE 02