KRISS COLLECTION ROMAN TUB FILLER WITH “CN” HANDLES
ITEM NUMBER
2250CN _ _-_ _
88
55
66
22
1212
11
33
44
22
1313
1414
1515
1212
SANTECSANTEC
77
99
55
1111
1616
1010
##
1
Complete CN Lever Handle
2
Spout Flange *
3
Quick Connect Spout Shank & Hardware
4
Valve Body Mounting Hardware
5
Hot Cartridge
6
Cold Cartridge
7
Complete Hot Valve
8 9
Complete Cold Valve
10
Tee Connector
11
All Thread
Flange Washer
12
Aerator Washer
13
Roman Tub Aerator without Restrictor
14 15
Aerator Housing *
Allen Key for Roman Tub Spout
16
* Please specify the finish when ordering the part.
PART
DESCRIPTION
Assembly *
KEEP THIS INSTRUCTION BOOKLET FOR FUTURE REFERENCE
PART #
PS-5K00S
00CN-R - right 00CN-L - left
P0206
KQ-5100S
P0420-SH
P0420-SC
P0495
P0496
P0340
P0341
PM-400
PM-356
PM-355
P0255L
PAGE 01
INSTALLATION INSTRUCTIONS
FLUSH BOTH SUPPLY LINES BEFORE INSTALLATION
AFTER FLUSHING, SHUT OFF BOTH SUPPLY LINES
MINIMUM HOLE SIZE FOR THE SPOUT AND HANDLE TRIM IS 1 1/4” AND MAXIMUM IS 1 1/2
SPOUT INSTALLATION
1
- Remove the Quick Connect Spout Shank and Mounting Hardware from the box. Remove the mounting hardware (metal washer and brass lock nut) from the Quick Connect Shank.
- From the top of the deck, slip the quick Connect shank through the assigned spout hole.
- Secure the quick connect shank by putting the washer and locknut back on the shank. Tighten the lock nut firmly.
2.
- Remove the faucet from the box.
- From the top of the deck, slip the spout (1) with the flange (3) and flange washer (12) onto the quick connect shank top. Align the spout and tighten the set screw with the Allen Key (16) provided..
Metal washer Brass lock nut
2250CN _ _
3
- Connect the spout shank to one of the outlet port of the handle valve bodies after the handle trims and valve bodies are installed. **
Note: for better installation it is advisable to place silicone caulking around all holes on the top of the deck
If the trim is ordered separately, please keep the shank protector on the quick connect shank at all time to avoid damages to the unit.
HANDLE INSTALLATION
1.
- Unscrew the pre-assembled handle trim (2) or (3) from the valve body.
- Slip the valve body (8) or (9) up from the bottom of the tub through the appropriate hole next to the spout. From tub top, screw the handle trim (2) or (3) with flange washer (12) back onto the valve body. The washer (12) must be gently pressed against the surface. Make sure that the handle turns freely in both directions.
2
- Position the valve body side outlet towards the tee connector (10) for easier pipe connection. Align the handle lever and tighten lock nut (5) firmly. Repeat the same procedure for the opposite side.
- Connect the water supply lines to the bottom inlets of the valve bodies. **
- Connect the valve body side outlet to the tee connector (10). **
Flanger washer
Metal washer Brass lock nut
Flange washer
Rubber washer
Metal washer
Brass lock nut
** The spout, handle valve bodies and tee connector can be connected with flex hoses (not provide by Santec) or copper pipe soldering. Please note that when soldering connections, do not use excessive heat. Excessive heat can damage the joints increasing possibility of leakage.
PAGE 02