ITEM NUMBER
1855NX _ _-_ _
REVERE COLLECTION
ROMAN TUB FILLER WITH HAND HELD SHOWER - “NX” HANDLES
33
8
8
1
1
11
191
9
2020
1515
1616
22
1010
1414
1313
1717
##
Complete Spout Assembly *
1
Complete NX Cross Handle
2
Tub Spout knob *
3
Quick Connect Spout Shank & Hardware
4
Valve Body Mounting Hardware
5
Hot Cartridge
6
Cold Cartridge
7
Complete Hot Valve
8
9
Complete Cold Valve
10
Diverter Cartridge
11
Diverter Mounting Hardware
Complete Diverter
12
Hand Shower Mounting Hardware
13
Hand Shower Flange and
14
Guide Tube *
15
Hand Shower Unit *
16
Hand Shower Hose
17
Aerator Washer
18
Roman Tub Aerator without Restrictor
19
Aerator Housing *
20
Large Allen Key for Roman Tub Spout
21
* Please specify the finish when ordering the part.
PART
DESCRIPTION
Washer *
Assembly *
PS-5R00S
00-NX-C cold/right00-NX-C cold/right
00-NX-H hot/left
P0416-LH
1212
1111
PART #
P0230
KQ-5000S
P0416-LC
P0493
P0494
P0500R
P0500
PM-Z11
Z-200-1
Z-200-2
Z-200-5
HS600
PM-356
PM-355
P0255L
22
66
88
44
77
55
22
99
55
2121
KEEP THIS INSTRUCTION BOOKLET FOR FUTURE REFERENCE
PAGE 01
INSTALLATION INSTRUCTIONS
FLUSH BOTH SUPPLY LINES BEFORE INSTALLATION
AFTER FLUSHING, SHUT OFF BOTH SUPPLY LINES
MINIMUM HOLE SIZE FOR THE SPOUT AND HANDLE TRIM IS 1 1/4” AND MAXIMUM IS 1 1/2”
SPOUT INSTALLATION
1855NX _ _
1
- Remove the Quick Connect Spout Shank and Mounting Hardware from the box.
Remove the mounting hardware (metal washer and brass lock nut) from the Quick Connect
Shank.
- From the top of the deck, slip the quick Connect shank with the brass plate through the
assigned spout hole.
- Secure the quick connect shank by putting the washer and locknut back on the shank.
Tighten the lock nut firmly.
2.
- Remove the faucet from the box.
- From the top of the deck, slip the spout (1) onto the quick connect shank top.
Align the spout and tighten the set screw with the Large Allen Key (21) provided.
3
- Connect the spout shank to one of the outlet port (OUT) of the diverter valve after the diverter
valve is installed. **
Note: for better installation it is advisable to place silicone caulking around all holes on the top
of the deck
If the trim is ordered separately, please keep the shank protector on the quick connect shank
at all time to avoid damages to the unit.
HANDLE INSTALLATION
1.
- Remove the pre-assembled trim(2) from the valve bodies. First the cap, then button, screw,
handle bell and last the top lock nut and fiber washer.
- Slip the valve body (8) or (9) up from the bottom of the tub through the appropriate hole next
to the spout.
- From tub top, insert the top mounting hardware back onto the valve. Do not tighten.
screw the handle bell of the handle trim (2) back onto the valve body. Adjust the height of the
handle bell against the top lock nut. Make sure the handle bell is flushed against the surface.
Insert the handle onto the stem and secure it with the screw. Tighten the screw firmly.
Insert the porcelain button (”COLD” on the right handle bell and “HOT” on the left handle bell.
Align the lettering and secure it using with the handle cap. Tighten it firmly.
Make sure that the handle turns freely in both directions.
Large Allen Key
Brass plate
Metal washer
Brass lock nut
Metal washer
Brass lock nut
Handle Cap
Button
Screw
Handle
Handle Bell
Brass lock nut
Fiber washer
Fiber washer
Brass lock nut
2
- Position the valve body side outlet towards the diverter valve (12) for easier pipe connection.
Align the handle lever and tighten lock nut (5) firmly. Repeat the same procedure for the
opposite side.
- Connect the water supply lines to the bottom inlets of the valve bodies. **
- Connect the valve body side outlet to the inlet (IN) of the diverter valve (12) after the diverter
is installed. **
PAGE 02