Sanken Electric Co SI-3050R Datasheet

SI-3000R Series
SI-3000R Seires
5-Terminal, Multi-Function, Full-Mold, Low Dropout Voltage Dropper Type with Reset Function
Features
• Reset signal output (As the output rises it sends a reset signal to the micro­computer to secure normal operation of the system. As the output drops a reset signal is also sent out to protect the system.)
• Reset signal detection output voltage level Voth is 92% of output voltage in the standard specification. Models with different setting values for different needs are scheduled to be added to the series.
• Delay time for reset signal can be adjusted freely by external capacitor.
• Compact full-mold package (equivalent to TO220)
• Output current: 1.5A
• Low dropout voltage :VDIF1V (at IO=1.5A)
Applicable to battery driven equipment with built-in microcomputer.
• Built-in droping type overcurrent, overvoltage, thermal protection circuits
• Low circuit current ID=typ.1.5mA(IO=0A)
Applications
• Microcomputer-controlled equipment
• Battery-driven micro-computer-controlled equipment
Absolute Maximum Ratings
Parameter
DC Input Voltage Voltage of Rest Signal Output Terminal DC Output Current
Power Dissipation
Junction Temperature Ambient Operating Temperature Storage T emperature Thermal Resistance (junction to case) Thermal Resistance (junction to ambient air)
Symbol
VIN
VRST
IO PD1 PD2
Tj TOP Tstg
Rth(j-c) Rth(j-a)
Ratings
SI-3050R
35
VIN
*1
1.5
18(With infinite heatsink)
1.5(Without heatsink, stand-alone operation) –30 to +125 –30 to +105 –30 to +125
5.5
66.7(Without heatsink, stand-alone operation)
(Ta=25°C)
Unit
V V
A W W
°C °C
°C °C/W °C/W
52
SI-3000R Series
Electrical Characteristics
Ratings
Parameter
Input Voltage Output Voltage
Dropout Voltage
Line Regulation
Load Regulation
Ripple Rejection
Quiescent Circuit Current Overcurrent Protection Starting Current (Drooping Type) Limited Current at Overcurrent Protection Operation DLY Threshold Terminal Reset Threshold V oltage Level (Voth: Threshold Output Voltage) Reset Threshold Voltage Hysteresis
VRST Terminal*4
*1: VIN(max) and IO(max) are restricted by the relation PD(max)=(VIN-VO)•IO=18(W). *2: Refer to the dropout voltage.(Refer to Setting DC Input Voltage on page 7.) *3: IS1 is specified at –5(%) drop point of output voltage VO on the condition that VIN=8V, IO=1.0A. *4: Reset signal output terminal VRST is an open-collector output. Use a pull-up resistor when connecting it to a logic circuit.
Source
H-level Output Voltage L-level Output Voltage Sink Current at H level Source Current at L level
Symbol
VIN
Conditions
VDIF
Conditions
Conditions
VOLINE
Conditions
VOLOAD
Conditions RREJ Conditions
Conditions
Conditions
Conditions
VDLyth
IDLY
Voth/VO
Voth VRSTH VRSTL
IRSTH
IRSTL
VO
IS1
IS2
SI-3050R
min. typ. max.
*2
6
4.80 5.00 5.20 VIN=8V, IO=1.0A
IO1.0A
IO1.5A
VIN=6 to 15V, IO=1.0A
VIN=8V, IO=0 to 1.5A
54
VIN=8V, f=100 to 120HZ
Iq
1.6
1.6
2.7 2.9 3.1 25 35 45
90 92 94
50 100 150
VCC–1
–16
1.5 5.0
VIN=8V, IO=0A
VIN=8V
VIN=8V
(Ta=25°C unless otherwise specified)
30
0.5
1.0
30
100
0.8
–20
Unit
*1
V V
V
mV
mV
dB
mA
A
A
V
µA
%
mV
V V
µA
mA
53
Loading...
+ 3 hidden pages