Sanken Electric Co SE115N Datasheet

Error Amplifier ICs (SE series)
Part No.
SE005N
012N 015N 024N 034N 040N 070N 080N 090N 105N 110N 115N 120N 125N 130N 135N 140N
Collector-Ground V oltage
V
CGO
(V)
12
50
150
Absolute Maximum Ratings (Ta=25°C)
Operating
Temperature
Ic (mA)
20
T
OP
–20 to +125 (TC)
(°C)
Electrical Characteristics
(Ta=25°C)
Output Detection
Voltage
VS (V)
5.0±0.1
12.0±0.2
15.0±0.2
24.0±0.2
34.0±0.3
40.0±0.4
70.2±0.8
80.2±0.8
90.0±0.8
105.2±0.8
110.2±0.8
115.2±0.8
120.2±0.8
125.2±0.8
130.2±0.8
135.2±0.8
141.2±0.8
Remarks
Low Vs
High Vs
Variable Voltage Detection Type Error Amplifier ICs
Absolute Maximum Ratings (Ta=25°C)
Part No.
SE-B3
Collector-Ground V oltage
V
CGO
(V)
150
Ic (mA)
20
External Dimensions
±0.1
φ
3.75
1.35
2.5
±0.15
±0.1
10.2
SE a
±0.2
±0.2
3.0
±0.7
16.0
±0.2
8.8
Nb
0.65
±0.1
2.5
1.7
+0.2 –0.1
±0.2
2.5
4.8
2.0
±0.5
±0.2 ±0.1
18.36.9
±0.3
3.0
±0.3
2.5
±0.3
5.8
Operating
Temperature
T
OP
–20 to +125 (TC)
a. Part Number b. Lot Number
(°C)
Electrical Characteristics
(Ta=25°C)
Output Detection
Voltage
VS (V)
141.2±0.6 Condition
IIN=4mA, RC=9.1k
RS=88.7k
Remarks
Variable voltage detection
Gain adjustment possible
(unit: mm)
123
Forming No.12
Loading...