Sanken Electric Co RK46 Datasheet

60V
Parameter
Type No.
AK 06 EK 06 EK 16 RK 16 RK 36 RK 46
AK 06
Ta—I
1.0
(A)
0.8
F(AV)
0.6
0.4
0.2
Average Forward Current I
0
F(AV)
0 25 40 50 75 100 150125
Ambient Temperature Ta (°C)
Absolute Maximum Ratings
I
V
RM
F (AV)
(V)
(A)
0.7
60 1.5
2.0
3.5
Derating
I
FSM
(A)
50Hz
Half-cycle Sinewave
Single Shot
Tj
(°C)
10
25
40 70
VF—IF Characteristics
10
1
(A)
F
0.1
0.01
Forward Current I
0.001 0 0.2 0.4 0.6 0.8 1.0 1.41.2
Forward Voltage VF (V)
Tstg
(°C)
=
T a 125ºC
100ºC
65ºC 26ºC
max
0.62
V
F
(V)
V
I
F
(A)
0.7
1.5 15
2.0
3.5
(Typical)
VR—IR Characteristics
10
1
(mA)
R
0.1
0.01
Reverse Current I
0.001 030402010 30 60 70 80
Electrical Characteristics (Ta
(mA)
R =
max
I
R
V
RM
I
R
(H)
(mA)
V
RM
V
R =
Ta = 100°C max
7.5
1.0
2.0 20
3.0 35
(Typical)
=
T a 125ºC
100ºC
60ºC
26ºC
Reverse Voltage VR (V)
25°C)
=
100 100/100–40 to +150
t
rr
(ns)
/
I
I
F
RP
(mA)
I
Rating
FMS
10
(A)
FSM
8
6
4
2
0
Peak Forward Surge Current I
1 5 50 10
Rth (j- )
Mass
(°C/W) (g)
22.0 0.13
20.0
17.0
0.3
15.0 0.45
12.0 0.6
8.0 1.2
(A)
FSM
I
Overcurrent Cycles
Others
Fig.
A B C D E F
20ms
EK 06
Ta—I
1.0
(A)
0.8
F(AV)
0.6
0.4
0.2
Average Forward Current I
0
0255040 75 100 150125
Ambient Temperature Ta (°C)
F(AV)
Derating
EK 16
Ta—I
1.5
(A)
1.2
F(AV)
0.9
0.6
0.3
Average Forward Current I
0
025 5040 75 100 150125
Ambient Temperature Ta (°C)
External Dimensions
(Unit: mm)
Flammability: UL94V-0 or Equivalent
F(AV)
Derating
Fig.
1.0
±
50.0
0.1
±
2.9
A
VF—IF Characteristics
10
1
(A)
F
0.1
0.01
Forward Current I
0.001 0 0.2 0.4 0.6 0.8 1.0 1.41.2
Forward Voltage VF (V)
VF—IF Characteristics
50
10
(A)
F
1
0.1
Forward Current I
0.01
0.001
0 0.2 0.4 0.6 0.8 1.0 1.41.2
Forward Voltage VF (V)
Fig.
±0.02
0.57
Cathode Mark
±0.7
±0.2
±0.1
2.4
62.3
5.0
B
=
T a 125ºC
100ºC
65ºC 26ºC
=
T a 125ºC
100ºC
60ºC 27ºC
±
0.6
Cathode Mark
2.7
(Typical)
(Typical)
Fig.
C
0.05
0.7
±
0.2
±
5.0
±
0.2
62.3
VR—IR Characteristics
10
=
1
(mA)
R
0.1
0.01
Reverse Current I
0.001 030402010 30 60 70 80
VR—IR Characteristics
30 10
(mA)
R
1
0.1
0.01
Reverse Current I
0.001 0 40 10020 60 80
±0.05
0.78
Cathode Mark
±0.2
2.7
T a 125ºC
100ºC
60ºC
26ºC
Reverse Voltage VR (V)
=
T a 125ºC
100ºC
60ºC
27ºC
Reverse Voltage VR (V)
Fig.
D
0.78
Cathode Mark
0.7
±
0.2
±
7.2
62.5
4.0
(Typical)
(Typical)
Fig.
±0.05
0.7
±
0.2
±
7.2
62.5
±0.2
I
FMS
10
(A)
FSM
8
6
4
2
0
Peak Forward Surge Current I
1 5 50 10
I
FMS
25
(A)
FSM
20
15
10
5
0
Peak Forward Surge Current I
1 5 50 10
E
±0.05
0.98
Cathode Mark
±0.2
4.0
Rating
Overcurrent Cycles
Rating
Overcurrent Cycles
Fig.
F
0.1
0.2
±
±
8.0
50.0
(A)
FSM
I
(A)
FSM
I
1.4
20ms
20ms
±0.1
Cathode Mark
±0.2
6.5
100
RK 16
Ta—I
1.5
(A)
1.2
F(AV)
0.9
0.6
0.3
Average Forward Current I
0
F(AV)
025 5040 75 100 150125
Ambient Temperature Ta (°C)
Derating
VF—IF Characteristics
50
10
(A)
F
1
0.1 =
T a 125ºC
Forward Current I
0.01
0.001
0 0.2 0.4 0.6 0.8 1.0 1.41.2
100ºC
60ºC 27ºC
Forward Voltage VF (V)
(Typical)
VR—IR Characteristics
30 10
(mA)
R
1
0.1
0.01
Reverse Current I
0.001 0 40 10020 60 80
=
T a 125ºC
100ºC
60ºC
27ºC
Reverse Voltage VR (V)
(Typical)
I
Rating
FMS
25
(A)
FSM
20
15
10
5
0
Peak Forward Surge Current I
1 5 50 10
Overcurrent Cycles
(A)
FSM
I
20ms
RK 36
Ta—I
2.0
(A)
1.6
F(AV)
1.2
0.8
0.4
Average Forward Current I
0
0 25 30 50 75 100 150125
Ambient Temperature Ta (°C)
F(AV)
Derating
L=15 mm L=15mm
P. C. B.
180•180 •1.6t
RK 46
T —I
5
(A)
4
F(AV)
3
2
t/ T 1/6
1
Average Forward Current I
0
80 90 100 110 120 130
Characteristics
F(AV)
=
=
t/ T 1/3
Lead Temperature T (°C)
Solder
D.C.
Sinewave
10•10mm 35µmt Cu
V
=60V
R
=
t/ T 1/2
VF—IF Characteristics
50
10
(A)
F
1
0.1 =
T a 125ºC
Forward Current I
0.01
0.001
0 0.5 1.0 1.5
VF—IF Characteristics
50
10
(A)
F
1
0.1
Forward Current I
0.01
0.001
0 0.2 0.4 0.6 0.8 1.21.0
100ºC
60ºC
R.T
Forward Voltage VF (V)
=
T a 125ºC
100ºC
60ºC 26ºC
Forward Voltage VF (V)
(Typical)
(Typical)
VR—IR Characteristics
50
=
10
(mA)
R
1
0.1
Reverse Current I
0.01
0.001 04020 60 80
VR—IR Characteristics
50
10
(mA)
R
1
0.1
0.01
Reverse Current I
0.001 04020 60 80
T a 125ºC
100ºC
60ºC
R. T
Reverse Voltage VR (V)
=
T a 125ºC
100ºC
60ºC
26ºC
Reverse Voltage VR (V)
(Typical)
(Typical)
I
Rating
FMS
40
(A)
FSM
30
20
10
0
Peak Forward Surge Current I
1 5 50 10
Overcurrent Cycles
I
Rating
FMS
70
(A)
60
FSM
50
40
30
20
10
0
Peak Forward Surge Current I
1 5 50 10
Overcurrent Cycles
(A)
FSM
I
20ms
(A)
FSM
I
20ms
101
Loading...