ConstruCtion .................................................................................................................................................................................................... 4
limitationof use .............................................................................................................................................................................................. 5
REPLACEMENT PARTS ............................................................................................................................................................... 11
USER ASSISTANCE .......................................................................................................................................................................12
These instructions generally describe the installation, operation and maintenance of the SANITAIRE
Room Air Sanitizer Model
RSCS280A. Questions that are not specifically answered by these instructions should be directed to the Factory.
Atlantic Ultraviolet Corporation® takes all possible precautions when packaging equipment to prevent damage. Carefully inspect and
report all damages immediately. Do not install damaged equipment.
Follow all instructions on any labels or tags. Carefully inspect all packing materials before discarding to prevent the loss of
accessories, mounting hardware, spare parts or instructions.
The information and recommendations contained in this publication are based upon data collected by the
Atlantic Ultraviolet Corporation® and are believed to be correct. However, no guarantee or warranty of
any kind, expressed or implied, is made with respect to the information contained herein. Specifications
and information are subject to change without notice.
2
AIR & WATER
Part No. 00-0195A2 (2.75 x 1.5)Part No. 00-0197A2 (2.75 x 1.5)
AIR
Part No. 00-0198A1 (1.25 x 3)
This fixture is designed for use with germicidalultraviolet lamps and must be installed in compliance with competent technical directions so that the users eyes and bare skin will not be subjected to injurious radiation.
WARNING
No. 00-0198A1
AS OF MAY 2002 THESE LABELS ARE BEING USED ON ALL OUR PRODUCTS
SAFETY WARNINGS
!
• All personnel should be alerted to the potential hazards indicated by the product safety labeling on this unit.
• The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to
observe precautions could result in injury to people or damage to property.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards.
Obey all safety messages that follow this symbol to avoid possible injury or death.
Danger indicates an IMMINENTLY
hazardous situation, which, if not avoided,
WILL result in death or serious injury.
Caution indicates a POTENTIALLY
hazardous situation, which, if not avoided,
MAY result in minor or moderate injury.
This symbol/pictorial is used to identify an ELECTRICAL SHOCK or ELECTROCUTION hazard.
This symbol/pictorial is used to identify the need to
wear approved ultraviolet blocking eye wear.
This symbol/pictorial is used to identify the need to
wear protective gloves.
SAFETY INSTRUCTIONS
To guard against injury, basic safety precautions should be observed, including the following:
1. Read and follow ALL safety instructions.
Avoid exposure to direct or reflected germicidal ultraviolet rays. Germicidal ultraviolet
rays are harmful to the eyes and skin.
2. Intended for indoor use only.
3. Do not alter design or construction.
4. Do not use this fixture for other than its intended purpose, as described in this manual.
5. Do not override safety interlock.
6. Do not mount under any source of moisture or condensation, such as humidifiers, cooling coils, etc.
7. Do not remove any labels or devices.
8.
9. Do not operate the fixture if there is visible or suspected damage to the fixture or, if applicable, there is damage
10. Keep inlet and outlet, of the blowers, clean and clear of debris.
11.
12. Stay clear of blowers, or other moving parts that can cause injuries.
13. Utility power supplied, to the fixture, MUST match power requirements listed on the unit label.
14. Always disconnect power to the unit before performing any service or maintenance.
15. Read and follow all notices and warnings on the fixture.
16. SAVE THESE INSTRUCTIONS.
SAFETY LABELSCAUTION
Danger Label: Ultraviolet Radiation
(00-0195A2)
Do not operate without proper electrical ground.
to power cord and/or plug.
Do not operate without the access door securely closed on the unit.
WARNING
ULTRAVIOLET
UV
No. 00-0195A2
RADIATION
Protect eyes and skin
from direct and reflected
radiation.
No. 00-0197A2
Danger Label: Hazardous Voltage
(00-0197A2)
DANGER
HAZARDOUS
VO LTAGE
Turn off and disconnect
power before servicing.
Warning indicates a POTENTIALLY
hazardous situation, which, if not avoided,
COULD result in death or serious injury.
Caution used without the safety alert symbol
indicates a potentially hazardous situation, which,
if not avoided, may result in property damage.
This symbol/pictorial is used to identify an
ULTRAVIOLET LIGHT hazard.
This symbol/pictorial is used to identify the need to wear
approved ultraviolet blocking face shield.
This symbol/pictorial is used to identify components
which must not be disposed of in trash.
It is the user’s responsibility to determine and validate
the suitability of this equipment for use in the user’s
system or process.
No warranty or representation is made by the manufacturer
with respect to suitability or performance of this equipment
or to the results that may be expected from its use.
The user should periodically inspect, clean as necessary
and confirm the presence and good legibility of the product
safety labels. Contact the factory for replacement labels in
the event that any of the labels are missing or illegible.
3
PRODUCT APPLICATION
ConstruCtion
The SANITAIRE® Room Air Sanitizer Model RSCS280A consists of:
®
• STER-L-RAY
This wavelength is highly effective against microbes including: virus, bacteria, and mold spores.
germicidal ultraviolet rays without approved ultraviolet blocking face shield and protective covering (such as gloves,
long sleeves with no gaps between cuffs and gloves).
• A SureliteTM Electronic Ballast capable of operating at 120v 50/60 Hz. Other power supplies may be available. Contact
factory for specifics.
• A polished reflector, whose design and specular aluminum construction maximizes ultraviolet intensity within
the exposure chamber.
• Power Cord - For 120v AC 50/60Hz single-phase standard household current, a NEMA 5-15, three-prong plug is provided for
a properly grounded outlet. (Consult factory for other plug types)
• Promate
allergens that pass through the filter. Filters are made with a heavy duty aluminum frame and a special weaved filter for years
of filtration.
• A louvered exhaust, which restricts ultraviolet radiation from passing into the room, protecting the room’s occupants from
ultraviolet exposure.
• Indicator LED’s work in pairs to provide a visual indication if a lamp has failed.
• All electronics and wiring are housed in an enclosure constructed of stainless steel. Stainless steel construction provides
strength, durability, and will withstand most harsh environments.
• An interlock safety switch. The interlock switch interrupts power to the sanitizer, when the access door is opened from
the lamp / exposure chamber.
Germicidal Ultraviolet Lamps deliver ultraviolet energy at the specific wavelength of 254 nanometers (nm).
Germicidal ultraviolet rays are harmful to eyes and skin; avoid exposure of direct or reflected
TM
Promate permanent, washable, electrostatic intake filter is electrostatically charged to trap up to 94% of dust and
PrinCiPleof oPeration
The SANITAIRE® Room Air Sanitizer is categorized as a germicidal ultraviolet fixture that utilizes germicidal ultraviolet lamps
that are completely enclosed within an exposure chamber and is safe for use in a clean, dry environment. The SANITAIRE®
effectively destroys airborne microbes including: bacteria, mold and virus in enclosed spaces.
The SANITAIRE® design has been carefully conceived to provide germicidal ultraviolet exposure for air disinfection. The
dosage, as it applies to ultraviolet disinfection, is a function of time, and the intensity, of ultraviolet radiation, to which the air
is exposed. The exposure time, in seconds, is the total time it takes the air to move through the ultraviolet field, produced by the
germicidal lamps.
All components are mounted in a stainless steel frame. Access to the lamp/exposure chamber is gained through the interlocked,
access door. Fixture operation can be monitored from the base panel.
The operation of the SANITAIRE® Room Air Sanitizer Model RSCS280A is as follows:
1. Air is drawn into the fixture through the the louvered filter panel.
2. The air is forced into the exposure chamber, where it is irradiated by the germicidal ultraviolet lamps.
3. LED indicator lights provide positive indication of operation of germicidal ultraviolet lamps.
4. The purified air exits the fixture, through the louvered exhaust panel, located at the opposite end of the fixture.
®
Figure 1 –SANITAIRE
Room Air Sanitizer Model RSCS280A Operation
4
Loading...
+ 8 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.