Sanitaire RSCS280 Owner's Manual

Document No. 98-1133C • Revised January 2011 • ©2003-2011 Atlantic Ultraviolet Corporation®
ultraviolet.com
375 Marcus Boulevard Hauppauge, NY 11788 USA
631.273.0500
Fax: 631.273.0771
e-mail: info@ultraviolet.com
Extensive Product Information Available at:
TABLE OF CONTENTS
SAFETY WARNINGS.....................................................................................................................................................3
SAFETY INSTRUCTIONS............................................................................................................................................3
PRODUCT APPLICATION...........................................................................................................................................4
C
ONSTRUCTION
............................................................................................................................................................4
RINCIPLE OF
OPERATION .............................................................................................................................................5
L
IMITATIONS
.................................................................................................................................................................5
UNPACKING...................................................................................................................................................................6
INSTALLATION.............................................................................................................................................................7
IXTURE PLACEMENT ...................................................................................................................................................7
SET-UP INSTRUCTIONS..................................................................................................................................................7
OPERA TION AND MONITORING CONTROLS......................................................................................................7
MAINTENANCE.............................................................................................................................................................8
L
AMP INSTALLATION
, REPLACEMENT OR CLEANING......................................................................................................8
I
NTAKE F
ILTER .............................................................................................................................................................9
C
LEANING OF E
LECTROSTATIC
FILTER...........................................................................................................................9
B
REAKAGE ...................................................................................................................................................................9
DISPOSAL OF M
ERCURY A
DDED LAMPS ........................................................................................................................9
OPTIONALACCESSORIES.......................................................................................................................................10
TROUBLESHOOTING................................................................................................................................................10
TECHNICAL SPECIFICATIONS...............................................................................................................................11
REPLACEMENT PARTS.............................................................................................................................................11
USER ASSIST ANCE.....................................................................................................................................................12
WARRANTY..................................................................................................................................................................12
ATENT NOTICE...........................................................................................................................................................12
These instructions generally describe the installation, operation and maintenance of the Sanitaire®Room Air Sanitizer Model RSCS280. Questions that are not specifically answered by these instructions should be directed to the Factory. Atlantic Ultraviolet Corporation takes all possible precautions when packaging equipment to prevent damage. Carefully inspect and report all damages immediately. Do not install damaged equipment. Follow all instructions on any labels or tags. Carefully inspect all packing materials before discarding to prevent the loss of accessories, mounting hardware, spare parts or instructions.
The information and recommendations contained in this publication are based upon data collected by the Atlantic Ultraviolet Corporation® and are believed to be correct. However, no guarantee or warranty of any kind, expressed or implied, is made with respect to the information contained herein. Specifications and information are subject to change without notice.
SAFETY WARNINGS
All personnel should be alerted to the potential hazards indicated by the product safety labeling on this fixture.
The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to observe precautions could result in injury to people or damage to property.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
Danger indicates an IMMINENTLY hazardous situation, which, if not avoided, WILL result in death or serious injury.
Warning indicates a POTENTIALLY hazardous situation, which, if not avoided, COULD result in death or serious injury.
Caution indicates a POTENTIALLY hazardous situation, which, if not avoided, MAY result in minor or moderate injury.
Caution used without the safety alert symbol indicates a potentially hazardous situation, which, if not avoided, may result in property damage.
This symbol/pictorial is used to identify an ELECTRICAL SHOCK or ELECTROCUTION hazard.
Product safety labels should be periodically inspected and cleaned, as necessary, to maintain good legibility. Always replace illegible safety labels. Contact factory to obtain replacement safety labels.
This symbol/pictorial is used to identify an ULTRAVIOLET LIGHT hazard.
This symbol/pictorial is used to identify the need to wear approved ultraviolet resistant face shield.
This symbol/pictorial is used to identify the need to wear protective gloves.
!
SAFETY INSTRUCTIONS
WARNING
: To guard against injury, basic safety precautions should be observed, including the following:
1. Read and follow ALL
safety instructions.
WARNING: Avoid exposure to direct or strongly reflected germicidal ultraviolet rays.
Germicidal ultraviolet rays are harmful to the eyes and skin.
2. Intended for indoor use only.
3. Do not alter the construction or design.
4. Do not use this fixture for other than its intended purpose, as described in this manual.
5. Do not override safety interlock.
6. Do not remove any labels or devices.
7. Do not mount under any source of moisture or condensation.
8. CAUTION: Do not operate without proper electrical ground.
9. Do not operate the fixture if there is visible or suspected damage to the fixture or, if applicable, there is damage to power cord and/or plug.
10. Keep inlet and outlet, of the blowers, clean and clear of debris.
11. Do not operate without access cover secured.
12. Stay clear of blowers, or other moving parts that can cause injuries.
13. Utility power supplied, to the fixture, MUST match power requirements listed on the fixture label.
14. WARNING:Always disconnect power to the fixture before performing any service or maintenance.
15. Read and follow all notices and warnings on the fixture.
16. SAVE THESE INSTRUCTIONS.
!!!
!
PRODUCT APPLICATION
CONSTRUCTION
The Sanitaire®Room Air Sanitizer Model RSCS280 consists of:
Germicidal ultraviolet lamps, which deliver germicidal ultraviolet energy in the specific wavelength of 254
nanometers (nm), which is highly effective against airborne microbes including: virus, bacteria, and mold spores.
Electronic ballasts.
A polished reflector, whose design and specular aluminum construction, maximizes ultraviolet intensity within the exposure chamber.
NEMA 5-15, three-prong plug that operates on 120VAC 60Hz single-phase standard household current is standard in most units. The
Sanitaire
®
is also available for operation on 230VAC 50Hz.
Permanent, washable, electrostatic intake filter, capable of removing airborne particles as small as 5 microns.
A louvered exhaust, which restricts ultraviolet radiation from passing into the room, protecting the room's occupants from ultraviolet exposure.
An enclosure and access cover constructed of stainless steel, type 304. Stainless steel construction provides strength, durability and lasting value.
An interlock safety switch. The interlock switch interrupts power to the sanitizer, when the access cover is removed from the lamp/exposure chamber.