Operating Manual for AC and Battery Powered Sensor
Faucets Models ES2RL & ESB2RL
SENSOR FAUCETS
AC OR BATTERY POWERED
1
Note: Model ES2RL and Hydrotek model H-6700C-LR are the same.
Model ESB2RL and Hydrotek model HB-6700C-LR are the same.
HYDROTEK INTERNATIONAL, INC.
5055 Forsyth Commerce Rd., Ste. 124, Orlando, FL 32807
OPERATION & MAINTENANCE MANUAL
Email: mike@hydrotekintl.com or armin@hydrotekintl.com
ADA Compliant. Meets all barrier
Conserves water and energy
Easily installed in new or retrofit
Competitively priced for today's
Promotes cleanliness & hygiene
Proven Hydrotek craftsmanship
Chrome plated, solid brass construction.
Wall mountable, waterproof control box
with armored, vandal resistant control and
Preset/adjustable sensor range 6"
various installation requirements.
at 0 but adjustable to 15, 30 or 60 seconds.
Prevents accidental sink overflow.
off delay is adjustable from 1 second
reduce maintenance costs.
Standard 6" gooseneck spout and 2.0 GPM
hole, wall/splash mounting.
All parts are field replaceable to ensure quick
Same faucet, field switchable to/from AC
Powered or Battery Powered.
provides reliable and smooth operation without
are unaffected by chlorine,
Control module automatically performs a
check of all electrical components.
No-touch system enhances hygiene in the
medical, institutional, food service industries,
Hydrotek Automatic Gooseneck Faucet
MeetsANSI/ASME A112.18.1M
A continuous, invisible beam is emitted from the sensor.
The faucet is activated by placing hands under the spout within
the effective range of the beam. Water starts to flow immediately
for as long as the user’s hands remain in the sensor range.
When hands are removed, the water flow stops. The sensor will
automatically reset and be ready for the next user.
In battery powered mode, flashing red light will indicate low battery
Solid Brass, Chrome Plated
Solid state, AC or Battery,
out:-Preset and Adjustable for 0, 15, 30,
Preset and Adjustable from 1
Armored, Vandal Resistant
Wattage: 0.4W (idle), 5W (in use)
Operating Pressure: 5psi to 125psi
in:-Input AC 120V 60 Hz or 220 V
Output DC 12V, 0.8A/Class 2
Armored, Vandal Resistant
Input AC 120V, Output DC 12V, 3A
(4) AA Alkaline Batteries Battery
400,000 on/off cycles, up to 4 years
(Bat)X(1) Faucet with Electronic Sensor
XX(1) Control Box w/6V DC Solenoid
(1) In-Line Filter with Clean
(1) 18" Flex, S.S. Supply Tube, 3/8"
XX(1) 2.0 GPM V.R. Laminar Flow Control
(4) AA Alkaline Batteries
Base Width (Outside Measurement)
Faucet Height (Aerator to Base)
Depth (Center of Aerator to Center of Faucet Base)
Optional Variations and Accessories:
Flow Aerator 1.5 & 2.5 GPM Laminar Flow Control and
Unit Voltage Adapter (AC Powered Only)
HC-001 Mixing/Check Valve (Mechanical)
HBL-04 Thermostatic Mixing Valve with Checks
8" deep Gooseneck and 6" or 8" Swing Spout
HYDROTEKINTERNATIONAL, INC.
5055ForsythCommerceRd.,Ste.124