Sangamo RPTS S250, RPTS Q550 Installation & User's Instructions

Page 1
Before attempting to install the
Sangamo Time Switch, please read
these instructions carefully.
Introduction
These installation and user instructions cover ALL SOLAR VARIANTS in the S250 & Q550 series – a range of reliable and highly accurate 24-hour solar dial time switches which offer,
according to the specic model, a range of
features suited to individual applications.
See Quick Reference Chart later.
1. The installation of this time switch should be
carried out by a qualied electrician in
accordance with current IEE wiring regulations.
2. Sangamo cannot be held responsible or liable for circuit connection other than those directly associated with our products.
3. To comply with safety requirements it is recommended that the time switch be installed with the base provided.
4. Terminals are for xed wiring only. Provision must be made in the xed wiring for a means
of disconnection from the supply having a contact separation of at least 3mm on all poles.
5. The time switch must be earthed.
6. This product is suitable for ‘Ordinary’ conditions only. It is not protected against dripping or moisture and so should be housed
in a suitable IP rated enclosure.
7. DO NOT REMOVE THE 2 SCREWS AT REAR OF SWITCH BASE.
8. Rotate cover anticlockwise and lift clear.
9. Remove extended terminal cover (E) by unscrewing captive screw (F).
10. Withdraw plug-in mechanism from switch
base, by grasping & pulling rmly on the dial.
11. Clear plastic from three xing holes
provided, removing debris. a.Use no8 wood screws or 2BA countersunk
screws for xing. b.Fix with suitable wall plugs for the surface
intended. c.When mounting the time switch on a metal surface, ensure the metal is adequately earthed to cover the 20A rating in accordance with IEE Regulations.
12. Strip back insulation by 6mm to ensure satisfactory connection with terminals. Connect switch to supply and load as in wiring diagrams above.
13. For S253 and Q553:
– WHERE SEPARATE MOTOR & SWITCH CIRCUIT SUPPLIES ARE NOT AVAILABLE – FIT A LINK BETWEEN TERMINALS 1 & 3.
14. Connect earth lead to earth connection (T).
15. Plug mechanism into base.
16. Cut & trim breakouts in the extended terminal cover (E) as necessary if wiring routed on the surface. Ret extended terminal cover (E) to base using captive screw (F).
This will lock the mechanism inside the base.
17. Follow setting instructions for the time switch then ret cover.
It is important for accuracy the correct switch is installed for the latitude zone in the country.
(see zone map later)
This type of dial automatically adjusts, once set, for seasonal changes in sunset and sunrise time during the year to suit lighting
applications. Depending on the model , xed
operations can also be set.
1. Remove dial screw (B) and pull dial free
from the mechanism. This makes adjustment easier.
2. DO NOT LOOSEN SERRATED CENTRE
NUT.
3. Turn date wheel (D) in either direction,
until correct calandar position is indicated in
date aperture (C). Each month is subdivided into six equal divisions, representing 5 days.
4. Sunset On & Sunrise Off operating arms
(K) & (A) each have an operating pin at the
centre point. This centre point equates to the
Greenwich Meridan (or 0 deg Longitude)
location in the country.
5. Adjustment for longitudinal variation can be
made by moving the operating pins (N) along the slot on BOTH operating arms (K) & (A), up to a maximum of +/- 45mins from centre.
To assist setting, each slot is marked with 15 minute divisions. Locations EAST of Greenwich Meridian
– move pins CLOCKWISE.
Locations WEST of Greenwich Meridian
– move pins ANTI – CLOCKWISE.
(see zone map later)
6. Further adjustment to advance the Sunset ON and delay the Sunrise OFF settings and
increase the overall ON time to suit darker environment applications, ie Stairwells, may
be possible.(Depending on the longitudinal variation used). Move operating pin (N) along
each operating arm as follows.
ADVANCE – move pin ANTI -CLOCKWISE on the Sunset ON operating arm (K). DELAY – move pin CLOCKWISE on the Sunrise OFF operating arm (A).
7. Ret dial onto mechanism ensuring dial hub engages cross-pin on centre shaft. Ret dial screw (B) . Turn dial in direction of the arrow until pointer P indicates WINTERTIME(GMT).
8. DIAL SHOULD RUN SET TO WINTERTIME THROUGHOUT THE YEAR.
1. Remove dial screw (B) and pull dial free
from the mechanism. This makes adjustment easier.
2. DO NOT LOOSEN SERRATED CENTRE
NUT.
3. Models : S251.14, S253.14, Q551.14 &
Q553.14 – (DEFAULT 24:00) – Move Pin already tted on Midnight Bridge (S) to required setting.
4. Models : S251.13, S253.13, Q550.13,
Q551.13 & Q553.13 – Transfer Pin (N) to Midnight Bridge (S)
Electromechanical Round Pattern Switch
SOLAR Dial Installation & User Instructions
Q550,
Q551 and Q553
S251 and S253
Introduction
Installation
Setting a Solar Dial
Solar Dial : Fixed off operation
between 20:30 & 01:00
Page 2
Unscrew & Transfer the Operating pin (N) from operating arm (A) onto the midnight bridge (S), to enable a xed off to be set as an alternative
to sunrise. Note orientation of Operating pin prior to transfer & ensure when re-positioned it is
securely xed using screw and will operate
the outer lever mechanism.
5. Midnight bridge (S) is calibrated in 15 minute intervals. Set Operating Pin at any time
between 20.30 & 01.00, however see point 6.
6. For correct unadjusted all year operation of the Sunset operating arm (K) and the xed off on the midnight bridge (S), the xed off should be set after 22.30. Fixed off’s set prior to this will interfere with sunset operating arm (K)
during April – September and cause the switch to operate for a short period when not re­quired.
7. Ret dial onto mechanism ensuring dial hub engages cross-pin on centre shaft. Ret dial screw (B) . Turn dial in direction of the arrow until pointer (P) indicates WINTERTIME(GMT).
8. All xed times need to be adjusted for the winter/summer clock changes to be uniform
during the year. March – Move time setting back, ie 24:00 to 23:00 October – Move time setting forward, ie 23:00 to 24:00
Models : S251.14, S253.14, Q551.14 &
Q553.14 (DEFAULT 05:00)
1. The adjustment is made to the rear of the
solar dial. Remove dial screw (B) and pull dial
free from the mechanism to gain access.
2. DO NOT LOOSEN SERRATED CENTRE
NUT
3. Slacken 8BA nut on underside of sector bridge and move spring tensioned lever 2, along sector bridge 1, until slot 4 coincides with time required. The Sector bridge is calibrated in 15 minutes intervals. Tighten 8BA nut.
4. Ret dial onto mechanism ensuring dial hub engages cross-pin on centre shaft. Ret dial screw (B) . Turn dial in the direction of the arrow until pointer (P) indicates
WINTERTIME(GMT).
5. Fixed operation will be obtained at the time set except in summer where the sunrise operating arm (A) operates earlier.
6. All xed times need to be adjusted for the winter/summer clock changes to be uniform
during the year. March – Move time setting back, ie 05:00 to 04:00 October – Move time setting forward, ie 04:00 to 05:00
Model: Q550.13
1. Day omitting device (D) prevents ‘On’
operation occurring on a chosen day or days of the week.
2. To OMIT operations on a given day, turn insert 1 clockwise on a given day , with a
screwdriver, until ARROWHEAD POINTS
OUTWARDS.
4. Ensure dial is showing the correct time.
Note the position of the operating arm (K) which operates the day omitting device (D)
once every 24 hours. If this operating arm has
PASSED the Day omitting device (D)
– turn black disc so the CURRENT day is set.
If this operating arm (K) has NOT REACHED the Day omitting device (D) – turn black disc to the PRECEDING current day.
SERVICE AND WARRANTY
Guarantee : As shown on product identication label. Any tampering or misuse will invalidate this
guarantee.
This product must meet Waste Electronic and Electrical Equipment Regulations (WEEE) for suitable
environmental recycling, recovery and/or disposal. End of life products should be handled in line with local regulations. Alternatively return End of life product to Sangamo for correct disposal.
CUSTOMER CARE POLICY
As part of Sangamo’s continuous improvement program, the Company operates a Customer Care Policy. This means that we welcome your comments and complaints, as it can help us to improve our services to you, our customer.
Due to our policy of continuous product improvement and development, the specications in this guide may be subject to change without prior notice.
Sangamo Limited
Industrial Estate, Port Glasgow,
Renfrewshire, PA14 5XG
Tel: 01475 745131 Fax: 01475 744567
Email: enquiries@sangamo.co.uk
Web: www.sangamo.co.uk
143700_A
WEE/JH0069TY
MODEL DIAL TEXT BATTERY OMIT BASE PINS SWITCH TYPE SPECIFICS MAX OPS
S251 SOLAR BLACK NO 3 SPST
FIXED ON & OFF
2 4
S253 SOLAR BLACK NO 4 SPST
FIXED ON & OFF
2 4
Q550 SOLAR RED YES ON 3 SPST 2
Q551 SOLAR RED YES 3 SPST
FIXED ON & OFF
2 4
Q553 SOLAR RED YES 4 SPST
FIXED ON & OFF
2 4
Quick Reference Chart
Current, Voltage, Frequency As shown on product identication label
Ambient Temperature 0-50 deg C
Live Parts Enclosed
Shock Protection Class 1
Dirt & Moisture Protection IP20
Contacts Micro-Disconnection
Battery Reserve
(Q550 series only)
100 hours (fully charged). NiMH rechargeable cell. The battery is soldered into a PCB. After the battery’s expectancy life of 10 years the timeswitch will cease to operate
or run slow, depending on the environment. A battery replacement kit is available to order.
Cycle/Channel
24 hour/1 channel
Summer/Winter Time Change
Not required set dial always to wintertime. (Note: any xed times
must however be adjusted to be uniform throughout the year)
Clock Accuracy
+/- 5mins per year @ 23 degC (Quartz)
Max Cable Size
6.0mm sqr
Power Consumpton
0.6W
Noise
A perpetual ticking noise is produced as internally a stepper motor drives the gear train.
Specication
Setting Day Omit Device
when fitted
Solar Dial: Fixed Early
Morning ON operation between 03:15 & 08:30
Loading...