Sangamo PSW Installation Instructions

Fit & forget...
Powersaver
Boost (PSB)
Boost Maxi (PSB MAXI)
Installation Instructions
WARNING - ISOLATE THE MAINS BEFORE INSTALLATION & SERVICING
THIS INSTALLATION SHOULD BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON, IN ACCORDANCE WITH THE CURRENT EDITION OF THE IEE WIRING REGULATIONS.
WARNING: All Powersaver products must be earthed, using the earth terminals at the rear of the switch. The following cabling is recommended:
L & N - 1.5mm² - 4.0mm² xed ê ê - 1.5mm² - 2.5mm² exible (retro t applications (only in conjunction with 143609 surface box) L Out & N Out - 1.5mm² - 2.5mm² xed or exible
Provision must be made in the xed
wiring for a means of disconnection from
the supply having a contact separation
of at least 3mm on all poles. This can be
provided by the consumer unit.
The Powersaver product range are
independently mounted time switches,
of electronic construction, which can be
surface or ush mounted. For ush tting a metal box of at least 32mm internal depth should be tted with the earth
terminal at the bottom.
For surface mounting use a patress box
with a minimum internal depth of 32mm.
Do not remove the Powersaver from its
packaging until the patress/wall box is tted and cleared of dust & debris. The
Powersaver range is suitable for use in a normal pollution situation.
The cable clamp at the rear of the unit is
for outgoing cables to the appliance only.
Installation Diagrams
Powersaver
Daily (PSD)
Weekly (PSW)
24/7 (PS24/7)
CONNECTION WARNING: Isolate mains
before installing. Supply terminals are for xed wiring only. Load terminals are for xed or exible wiring. Remove 8mm of insulation from each wire & twist any
multiple connection together.
All earth conductors must be sleeved
(green/yellow) and connected to earth
terminals provided on rear of switch. Fit
the Powersaver to the patress box using
screws provided.
When cutting the aperture for the output
exible cord ensure no sharp edges
remain.
PLEASE NOTE: This product is not suitable for mounting on unearthed metal or metallic surfaces.
Wiring Diagram
LNOutNLOut
EARTH
LIVE
NEUTRAL
LOAD MAINS IN
Flush Mounting
Programming
BOOST (PSB)
The Powersaver Boost offers 3 options for the on period duration using the BOOST button.
Press once = ½ hour Press twice = 1 hour Press three times = 2 hour Press four times = Cancel function
While the Boost is active the indicator
light will change to show the maximum
remaining time; e.g. 2 Hours selected
BOOST MAXI (PSB MAXI)
The Powersaver Boost Maxi performs exactly as the ‘Boost’ product but offers
alternative on period durations using the BOOST button.
Press once = 1 hour Press twice = 3 hours Press three times = 5 hours Press four times = Cancel function
DAILY, WEEKLY, 24/7 (PSD, PSW,
PS24/7) - See ap label for identication if in doubt
Program Methods:
1. Press SET to exit initial reset display if shown.
2. Press SET to scroll through & review settings in sequence.
3. Press - & + to adjust these settings.
4. 24/7 ONLY - Press BOOST to copy
programs into the next day.
5. 24/7 ONLY - Press OFF/ON to skip to
a day
6. If a button is not pressed within 30 seconds, the unit will revert back to the normal running state.
Typical Displays:
Date/Time Setting Mode
Mon Tue Wed Thu Fri Sat Sun
18:88
ERROR BOOST
Reset/Initial Set Time
12:00
Set Year Set Month
01
Set Date
PROG
AM PM
OFF ON
8
y
12:00
1
PM
n
d
Program Setting Mode
WEEKLY
Mon Tue Wed Thu Fri
AM
12:00
24/7
Mon
AM
12:00
PROG
1
PROG
1
ON
ON
DAILY
Mon Tue Wed Thu Fri
12:00
Sat Sun
PROG
AM
1
ON
Surface
Mounting
Programming (cont...)
Wed
6:15
Normal Display Programming Display
(outwith program) (during program)
Boost Mode Holiday Mode Keypad Locked
Programming Sequence
Daily (PSD)
Time, Year, Month, Day,
Prog 1on, Prog 1off, Prog 2on, Prog 2off, Prog 3on, Prog 3off,
Return to normal display
Weekly (PSW) Time, Year, Month, Day,
Mon-Fri: Prog 1on, Prog 1off, Prog 2on, Prog 2off, Prog 3on, Prog 3off, Sat-Sun: Prog 1on, Prog 1off, Prog 2on, Prog 2off, Prog 3on, Prog 3off,
Return to normal display
24/7 (PS24/7) Time, Year, Month, Day,
Mon: Prog 1on, Prog 1off, Prog 2on, Prog 2off, Prog 3on, Prog 3off, Tue: Prog 1on, Prog 1off, Prog 2on, Prog 2off, Prog 3on, Prog 3off, Wed: Prog 1on, Prog 1off, Prog 2on, Prog 2off, Prog 3on, Prog 3off, Thu: Prog 1on, Prog 1off, Prog 2on, Prog 2off, Prog 3on, Prog 3off, Fri: Prog 1on, Prog 1off, Prog 2on, Prog 2off, Prog 3on, Prog 3off, Sat: Prog 1on, Prog 1off, Prog 2on, Prog 2off, Prog 3on, Prog 3off, Sun: Prog 1on, Prog 1off, Prog 2on, Prog 2off, Prog 3on, Prog 3off,
Return to normal display
Notes on Programming:
a) All programs must be in consecutive order, i.e. program 1 must be before
program 2 & program 2 before program 3. If the wrong order is programmed
error messages will be displayed b) If only 2 or less programs are required, for the remaining programs enter the same on & off times, e.g. Prog 3 on 8:00pm, off 8:00pm. This ensures
the unwanted program is cancelled.
c) Programming past midnight is NOT allowed. An error message will be displayed. To overcome this the program needs to be split as per example-
Desired program period - on 10:00pm off 7:00am make Prog 1 - on 12:00am off 7:00am make Prog 2 - on 7:00am off 7:00am make Prog 3 - on 10:00pm off 12:00am Progs make up desired program period leaving prog 2 available for a program
during the day. d) if you try to input the off time before the on time an error message will be displayed. Press SET to continue.
PM
Wed
6:15
Wed
6:15
PROG
PM
3
ON
OFF
12:00
L
PM
Boost Function
Offers 3 options for on period duration outwith a program using the BOOST button. Press once = 30mins Press twice = 1 hour Press three times = 2 hours Press four times = Cancel function
Duration can be extended or cancelled by successive presses.
Off (Holiday) Function
Allows you to suspend programmes whist still allowing the Boost function to
be used using the OFF/ON button Press once = Suspend programs Press twice = Cancel
NOTE: This is NOT an override function for programs. NOTE: BOOST button is still active.
Program Override Function
If during a program On time you wish to cancel the program simply press the
BOOST button once.
NOTE: The program settings will not be affected & the next time this program is due, it will function as normal. Adjoining programs will also be cancelled.
Product Reset (return to default settings)
Switch off power to unit. Hold in BOOST button whilst switching power back on.
1 displayed = press BOOST 2 displayed = press SET 3 displayed = press ­4 displayed = press + 5 displayed = press OFF/ON All LCD segments ashing displayed (reset) = press SET to reprogram.
Keypad Lock
Press - & + together for 5 seconds to lock settings = display briey shows L
NOTE: BOOST button is still active
NOTE: display shows L when other buttons pressed
Press - & + together for 5 seconds to unlock settings.
Specication
Contact Rating: 16A Resistive, 240V a.c.
Supply: 240V, 50-60Hz a.c. Fixing: Single patress - surface & flush mounting
Resolution of Programs: 10 minutes Auto Summer/Winter Time Change: Yes
Power Consumption: 10.3VA Maximum Live Parts Protection: This unit is totally protected by the enclosure
Dirt & Moisture Protection: IP40 Shock Protection: Class 1 (this must be
connected to earth) Case Material: Polycarbonate, PT1 175
Temperature Rating: T35 Operating Temperature: 0°C to 35°C
Memory Reserve (except Boost): 4 hours - when
on power for previous 12 hours
SERVICE AND WARRANTY Your product is not user serviceable. PLEASE DO NOT TRY TO DISMANTLE THE UNIT.
This product is guaranteed by your supplier for 5 years from the date of manufacture. If it should become defective please contact your installer or supplier for a replacement unit or visit www.sangamo.co.uk/returns
This product must meet Waste Electronic and Electrical Equipment Regulations (WEEE) for suitable environmental recycling, recovery and/or disposal. End of life products should be handled in line with local regulations. Alternatively
return end of life product to Sangamo for correct disposal.
CUSTOMER CARE POLICY
As part of Sangamo’s continuous improvement program, the company operates a Customer Care policy. This means we welcome your comments and complaints, as it can help us to improve our services to you, our customer.
Due to our policy of continuous product improvement and development, the specications in this guide may be subject to change without prior notice.
Program Settings:
PSD - Max 3 On & 3 Off operations (Daily) ­each day the same
PSW - Max 3 On & 3 Off operations (Mon-Fri) & Max 3 On & 3 Off alternative operations (Sat/ Sun).
PS24/7 - Max 3 On & 3 Off operations (7 days) each day independently programmable.
Boost Facility: User selectable
PSB - ½, 1 or 2 hours
PSB MAXI - 1, 3 or 5 hours
Type of Action: Type 1B Control Pollution Category: Normal
If you have a problem or require any further information please
contact our technical team on:
01475 745131
Sangamo Limited
Industrial Estate, Port Glasgow,
Renfrewshire, PA14 5XG
Tel 01475 745131
Fax: 01475 744567
Email: enquiries@sangamo.co.uk
Web: www.sangamo.co.uk
WEE/JH0069TY143082 Issue L