Sangamo E855, E854 Installation Instructions

Round Pattern Time Switch
Electronic
Installation & User Instructions
E854 and E855
Before attempting to install the
Sangamo Time Switch, please read
these instructions carefully.
Introduction
These installation and user instructions cover all E850 MODEL VARIANTS – A range of reliable and highly accurate 7 day time switches.
Installation
1. The installation of this time switch should
be carried out by a qualied electrician in
accordance with current IEE wiring regulations.
3. To comply with safety requirements it is recommended that the time switch be installed with the base provided.
4. Terminals are for xed wiring only. Provision must be made in the xed wiring
for a means of disconnection from the supply having a contact separation of at least 3mm on all poles.
5. This product is suitable for ‘Ordinary’ conditions only. It is not protected against dripping or moisture and so should be housed in a suitable IP rated enclosure if required.
6.
DO NOT REMOVE THE 2 SCREWS AT
REAR OF SWITCH BASE.
7. Rotate cover anticlockwise and lift clear.
8. Remove extended terminal
cover (A) by unscrewing captive screw (B).
9. Lift handle (C) and withdraw plug-in mechanism from switch base, by pulling.
10. Clear plastic from three xing holes
provided, removing debris. a. Use no8 wood screws or 2BA countersunk
screws for xing so screw heads sit ush
inside base.
b. Fix with suitable wall plugs for the surface
intended. c. When mounting the time switch on a metal surface, ensure the metal is adequately earthed to cover the 20A rating in accordance with IEE Regulations.
11. Strip back insulation by 6mm to ensure satisfactory connection with terminals. Connect switch to supply and load as in wiring diagrams above.
12.
For E855 WHERE SEPARATE MOTOR & SWITCH CIRCUIT SUPPLIES ARE NOT AVAILABLE – FIT A LINK BETWEEN TERMINALS 1 & 3.
13. Plug mechanism into base.
14. Cut & trim breakouts in the extended
terminal cover (A) as necessary if wiring
routed on the surface. Ret extended terminal
cover (A) to base using captive screw (B). This will lock the mechanism inside the base.
15. Follow setting instructions for the time
switch then ret cover with lug (Y) in position
as shown.
C
Y
Z
A
B
Important: The unit may be congured ‘off power’ if sufcient charge remains in its
rechargeable battery.
Press ‘Set On’ for 5 secs to activate display.
If there is sufcient charge in the battery the
normal operating display will be shown and you can ‘Set the Clock’ & ‘Programme’ the unit off power. The display will disappear & conserve the battery after 90 secs without a button press.
If LED segments are ashing - the battery is
fully discharged. Power to unit is required to continue. Press ‘Set Clock’ and follow ‘Setting the Clock’ instructions overleaf.
Normal Operating Mode
The 24hour analogue display shows programmed switching ‘On’periods, represented by means of electronic markers and an analogue ‘hand’ showing the time on the 24-hour analogue clock.
A preset switching ‘On’ period from 7 am to 5 pm is automatically programmed into the time switch memory. See programming section to adjust.
The digital display comprises a 12-hour digital clock and electronic markers to show PM, day of week, date and month.
Setting the Clock
12 Hour Digital Clock
Month Marker (During set clock only)
Day Marker
Date Marker (During set colc only
PM Marker
Programme Review
Override
Holiday Mode / Permanent OFF
Pre-set ON Period
Analogue Clock Hand
24 Hour Analogue Display
Follow the sequence of steps below,
Note: setting the clock will cancel an override.
Programming the Time Switch
There is standard ‘On’ period from 7.00 am to 5.00 pm, Mon-Sun memorised into the product. Programming the time switch to a time other than that is achieved by ‘painting in’ or ‘wiping out’ ‘On’ markers as the analogue hand is moved around the 24-hour clock display in either direction using the + or - buttons.
Notes: Press Set Prog as required to skip to required day. Pressing Set prog memorises a days program. Analogue hand starting point is 0:00 LED ashing indicates programming neutral mode. Press + or – to reach the time you require before programming. Press set ON or set OFF twice will bring unit back to programming neutral mode. Programming is in 15 minute increments as viewed on the Digital display; 15, 30, 45, 00. The Analogue display segment resolution is 30 minutes.
So program periods at 15 or 30 = one segment, 45 or 00 = next
segment.
Reset
The unit can be reset back to the default settings simply by pressing the + and - keys simultaneously until the full display occurs. Continue pressing + and - keys and press set clock, revu & copy to reset the unit.
Specification
No. of Output Channels : 1 programmed channel.
Programming Capability: 7-day programmable.
Max. No of Status Changes : Up to 48 On/Off operations per day.
Override Facility : Temporary off or 2 hour, ‘Boost-On’.
Digital Display : 12 hour display to 1 minute resolution.
Analogue Display : 24-hour display with 30 minute programme indication
and 15 minute switchng.
Battery Back-Up : Rechargeable battery will retain memory typically -
20 days after 6 days power 11 days after 24 hours power
Holiday Mode : Suspends program for up to 14 days.
Ambient Temperature Range : 0 to 35 deg C.
Current Voltage, Frequency : As shown on identication label.
Max. Cable Size : 6.0 mm.
BST/GMT Changeover : Automatic.
Accuracy : Better than 5 minutes per annum.
Protection : Live Parts - Enclosed i.e. this timer is totally protected
by the enclosure. Direct Protection - Normal domestic dust deposits only. Moisture Protection - Ordinary i.e. has no special protection against moisture. Shock Protection - Class 11, both functional and supplementary insulation.
Mounting : Surface
Software Class : Class A
Contacts : Type 1B disconnection
SERVICE AND WARRANTY
Guarantee : As shown on product identication label. Any tampering or misuse will invalidate this
guarantee.
This product must meet Waste Electronic and Electrical Equipment Regulations (WEEE) for suitable environmental recycling, recovery and/or disposal. End of life products should be handled in line with local regulations. Alternatively return End of life product to Sangamo for correct disposal.
CUSTOMER CARE POLICY
As part of Sangamo’s continuous improvement program, the Company operates a Customer Care Policy. This means that we welcome your comments and complaints, as it can help us to improve our services to you, our customer.
Due to our policy of continuous product improvement and development, the specications in this guide may be subject to change without prior notice.
WEE/JH0069TY
Industrial Estate, Port Glasgow,
Sangamo Limited
Renfrewshire, PA14 5XG
Tel: 01475 745131 Fax: 01475 744567
Email: enquiries@sangamo.co.uk
Web: www.sangamo.co.uk
850703_R