This programmer can automatically switch your
central heating or hot water ON and OFF up to 3 times
a day, at whatever times you choose. Timekeeping is
maintained through power interruptions by a nonreplaceable battery designed to last for the lifetime
of the programmer. The clock is automatically put
forward 1 hour at 1:00am on the last Sunday of March
and back 1 hour at 2:00am on the last Sunday of
October. The clock is factory pre-set to UK time and
date, but you can alter the time setting if you wish.
During installation, the installer selects 24 hour, or
5 day/2day, or 7 day programming and 2 or 3 on/o
periods per day, via a 4 position DIP switch on the
back of the unit (see installation instructions).
IMPORTANT: These settings should only be
changed by a qualied person. Contact your
installer.
IMPORTANT: This programmer is not suitable
for the switching of devices greater than 2 Amp
rated per channel. (e.g. Not suitable for use as an
immersion timer)
Conguration
When setting time, date or changing programme
times the rst screen displayed indicates the
conguration as set up by the installer. (See ‘Setting
The Time section)
CongurationDisplay
2 ON/OFF Pumped System2PU
3 ON/OFF Pumped System3PU
Times for Central Heating and How Water can be
independently set.
The 24 hour, or 5 day/2day, or 7 day programming
option as set up by the installer can also be veried
at this stage by how the Monday to Sunday indicators
are displayed.
Programming
Option
7 DAYMon to Sun individually
5/2 DAYMon to Fri together then
24 HOURMon to Sun together shown
Now press any button to move to Setting the Time
and Day.
Built In Programme
For convenience, the programmer has a built in
programme which will be satisfactory for many
people, but which can be changed very easily (see
section CHANGING PROGRAMME TIMES). Once the
unit is powered up this built in programme will run.
If the user changes from the built in programme and
wishes to return to it, then pressing the reset button
with a non metallic pointed tool will return the unit
to the built in / default programme.
Mon to Sun Indicators
ash
shown
Sat & Sun together
[5]
NOTE: Every time the reset is pressed, the time
and date must be set again. See the sections
‘Setting The Time & Setting The Date’
Factory Programme Settings
2Pu3PuMon-FriSat-Sun
1st ON1st ON6:00am7:00am
1st OFF1st OFF8:30am9:00am
-2nd ON12:00 noon12:00 noon
-2nd OFF12:00 noon12:00 noon
2nd ON3rd ON4:30pm4:30pm
2nd OFF3rd OFF10:30pm11:30pm
If the unit is installed as a 24 hour programmer the
built in programme will be the same for each day (i.e.
Sat-Sun be same as Mon-Fri above).
Selecting Operating Mode
CH1 MODE
ONCentral Heating and Hot Water is ON
AUTOCentral Heating and Hot Water will be
ALL
DAY
OFFCentral Heating and Hot Water is OFF
continuously
switched ON or OFF as programmed
Central Heating and Hot Water will
be switched ON only once each day
between the rst ON time and last OFF
time
continuously
CH2 MODE
HW MODE
Setting The Time
• Press the SET button once. The conguration
setting will appear on the screen.
• Press the SET button again. The clock icon [1] on
the screen will ash.
• Press the +/- buttons to adjust the time. Time will
change quicker if pressed continually.
• Press SET once to move on to setting the DATE or
press multiple times to return to RUN mode.
Setting The Date
• Press the SET button until the Y:XX icon (year)
appears and the D (DATE) icon [2] ashes.
• Press the +/- button to set the year.
• Press NEXT button. M:XX appears (month).
• Press +/- button to set month.
• Press NEXT button. D:XX appears (Day).
• Press +/- button to set day.
[6]
[1] [2][3][4]
You can review or edit the date you have set just
by pressing NEXT button again and repeating the
sequence above. To conrm the date and move on to
PROGRAM mode press SET button once or press SET
button multiple times to return to RUN mode.
Changing Central Heating Times
The built in programmes can easily be changed to
better suit your lifestyle.
• Press SET button until radiator icon [3] ashes in
the display and 1 ON [4] appears. This indicates
the time shown on the display is the rst ON time.
• By pressing the +/- buttons you can alter the ON
time to the time you want.
• Press NEXT button, display will now show 1 OFF
[4].
• By pressing the +/- buttons you can alter the OFF
time to the time you want.
• Press NEXT button to access remaining ON/OFF
periods and alter in same manner as above.
• To return to RUN mode, press the SET button until
the display indicates RUN on the display
NOTE: Programming is in 10 minute segments.
Changing Hot Water Times
Press SET button until tap icon [3] ashes in the
display and 1 ON [4] appears. This indicates the time
shown on the display is the rst ON time and proceed
in same manner as ‘To change the Central Heating
Times’ above.
7 Day Programmer Option
If the unit is installed as a 7 day programmer, the
initial programme displayed will be for Monday.
You can go to any date of the week by pressing the
DAY button repeatedly.
The ON/OFF times can be changed for each day
as described above in the section “CHANGING
PROGRAMME TIMES”.
If you press the COPY button, the current programme
will be copied onto the next day.
NOTE: it is not possible to copy Sunday to Monday.
5/2 Day Programmer Option
If the unit is installed as a 5 day/2 day programmer,
the initial programme displayed will be for Monday
to Friday.
Pressing the DAY button will take you to the
programme for Saturday and Sunday.
The ON/OFF times can be changed for each day
group as described above in the section “CHANGING
PROGRAMME TIMES”.
If you press COPY button, the current programme
will be copied onto the next day group.
Page 2
ONOFFAUTOALL DAY
RESET
Choice PR3n
24 Hour Programmer Option
If the unit is installed as a 24 hour programmer, the
built in programme will be the same for each day.
The COPY & DAY buttons have no aect if installed
as a 24 hour programmer.
Programming Notes
The unit will automatically return to normal running
mode if a period of 30 seconds passes without any
buttons being pressed.
For convenience, to allow for programmes to go past
midnight, the programme day is from 03:00am to
02:50am the next day.
If a programme is required to run from 1.00 am to
8.00 am then 2 programmes must be used because it
is not possible to programme through 2.50 am. (The
programme should be split up into two sections; 3.00
am > 8.00 am and 1.00 am > 2.50 am).
[6]
Reset
Press the reset button with a non-metallic pointed
tool to restore the built in programme. As well as
restoring the built in programme, it also resets the
time to 12:00pm and the date to 01/01/2014. Initially
the display shows all segments lit for a few seconds,
but then will show the current conguration. See
‘Setting The Time’ section to continue.
As a safety feature aer reset the unit will be in OFF
operating mode. Reselect your required operating
mode.
Using Advance
The ADVANCE function allows the user to move to
the next ON or OFF programme for a “one o” event,
without having to change the programme or change
the operating mode.
Warning: The ADVANCE function is only available
when programme is in AUTO or ALL DAY operating
modes.
To advance Central Heating 1 or 2
Press the appropriate Central Heating channel ADV
button. This will turn the Central heating ON if it is in
an OFF period and OFF if it is in an ON period. It will
stay in this state until either ADV button is pressed
again, or until a programmed ON/OFF period
commences. The word ADV [5] will appear in the le
hand of the LCD.
To advance Hot Water
Press the Hot Water channel ADV button. This will
turn the Hot Water ON if it is in an OFF period and
OFF if it is in an ON period. It will stay in this state
until either ADV button is pressed again, or until a
programmed ON/OFF period commences. The word
ADV [5] will appear in the tle of the LCD.
SERVICE AND WARRANTY
Your product is not user serviceable. PLEASE DO NOT TRY TO DISMANTLE THE UNIT.
This product is guaranteed by your supplier for 5 years from the date of manufacture. If it should become defective
please contact your installer or supplier for a replacement unit or visit www.sangamo.co.uk/returns
This product must meet Waste Electronic and Electrical Equipment Regulations (WEEE) for suitable environmental
recycling, recovery and/or disposal. End of life products should be handled in line with local regulations. Alternatively
return end of life product to Sangamo for correct disposal.
CUSTOMER CARE POLICY
As part of Sangamo’s continuous improvement program, the company operates a Customer Care policy. This means we
welcome your comments and complaints, as it can help us to improve our services to you, our customer.
Using +HR Boost
For +Hr Central Heating 1 or 2
Press the appropriate Central Heating channel +HR
button to make the desired selection with one, two
or three hours extra heating [6] and cancel options
oered.
Warning: The +HOUR function is only available
when programme is in AUTO, ALL DAY or OFF
operating modes.
If the Central heating operating mode is OFF, then
it will switch on for the extra hours selected. If the
Central heating mode is AUTO or ALL DAY, then
during an OFF period, it will switch on for the extra
hours selected. If during an ON period, then it will
temporarily extend that programme by the number
of hours selected.
For +Hr Hot Water
Press the Hot Water channel +HR button. to make
the desired selection with one, two or three hours
extra heating [6] and cancel options oered. Warning: The +HOUR function is only available
when programme is in AUTO, ALL DAY or OFF
operating modes.
If the Hot Water operating mode is OFF, then it will
switch on for the extra hours selected. If the Hot
Water mode is AUTO or ALL DAY, then during an OFF
period, it will switch on for the extra hours selected.
If during an ON period, then it will temporarily
extend that programme by the number of hours
selected.
NOTE: If the programmer is in the OFF mode and
then +HR button is pressed (+1 HR, + 2 HR, or + 3 HR)
and the resulting time of the boost overlaps a START
/ ON time in the AUTO mode programme memory
then the boost will disengage. If this happens simply
press +HR button again and the boost will activate
for the time period chosen.
[1] [2][3][4]
[5]
Holiday Mode
The Holiday function allows the user to turn all
channels to the OFF operating mode, for a settable
amount of days from 01-99 days. During this
function a suitcase icon will be displayed.
The number of days will decrease at midnight each
day.
The +HR boost override can be used during a
holiday period.
1. Press & Hold DAY button for 4 seconds to enter
the holiday function , d:01 ashes.
2. Press +/- button to set the holiday days.
3. Press DAY button to activate.
4. Press & Hold DAY button for 4 seconds to
cancel a holiday period.
Warning: The Holiday function is only available in
AUTO, ALL DAY or ON operating modes.
Power Interruption
In the event of a mains supply failure the screen will
go blank but the back-up battery ensures that the
programmer continues to keep the time and retain
your stored programme. When power is restored,
if there has been no change to the rear DIP switch,
the programmer returns to its expected operating
condition.
If the conguration setting on the rear DIP switch
has been altered during the power interruption the
screen will initially show the new conguration. And
the appropriate factory default programme (see
BUILT IN PROGRAMME section) will be installed.
Press SET button to return to RUN mode.
If you have a problem or require any
further information please contact us on:
01475 745131
Sangamo Limited
Industrial Estate, Port Glasgow,
Renfrewshire, PA14 5XG
Tel 01475 745131
Fax: 01475 744567
Email: enquiries@sangamo.co.uk
Web: www.sangamo.co.uk
Due to our policy of continuous product improvement and development, the specications in this guide may be subject
to change without prior notice.
143797 Issue C
WEE/JH0069TY
Page 3
Fit & forget...
16
Tahama 5 bold font or as approved
PR1n & PR3n143786
24Hr
4
5/2 Day
Gravity
Pumped
12
PR2n143787
2 on/offs3 on/offs
7 Day
3
REV DRAWN BY
ENGINEERING
CHANGE
NUMBER
ALTERATION DETAIL
J Dewar
n/a
First issue
16
3
5
4
Choice PR3n - 3 Channel Programmer
Installation Instructions
Pre-Installation Set Up
Before installing, set the bank of 4 DIP
Switches on the back to congure the unit
according to the chart below:
Not Used
2
24Hr
2 on/offs
314
DIP Switches Shown in Factory Default
Positions. (black = raised actuator of
switch)
24 Hr Runs same programme every day.
5/2 Day Allows dierent on/o times at
weekend.
7 Day Allows dierent on/o times every
day.
Installation Safety Notes
This unit must be installed by a suitably
qualied person in accordance with the
latest IEE Wiring Regulations.
Isolate mains supply before commencing
installation. Please read all installation
instructions before proceeding.
Ensure that the xed wiring connections to
the mains supply is via a fuse rated at not
more than 3 amps and a class ‘A’ switch
having a contact separation of a minimum
of 3mm in all poles. The recommended
cable sizes are 1.0mm2 or 1.5mm
Not Used
7 Day
5/2 Day
3 on/offs
2
Technical Data
Power Supply: 230V AC, 50Hz
Operating Temperature: 0°C to 40°C
Switch Rating: 230V AC, 2(1)A per channel
Contact Type: 1B , Micro-Disconnection
Battery Type: Lithium Cell CR2032
Enclosure Protection IP30
Plastics Thermoplastic, ame retardant
Insulation Class Double
Wiring: For xed wiring only
Backplate Industry standard
Dimensions: 140mm x 87mm x 37mm
Clock Accuracy +/- 1.5 sec/day
Program Cycle 24hr, 5/2day or 7day selectable.
Program On/os per day 2on/o, 3on/o selectable
Program Resolution 10mins
Program Selection Auto, On all day, On constant, O
Program Override +1,2 or 3 Hr Boost & Advance to next program
Complies with EN60730-1, EN60730-2.7,
EMC Directive 2004/108/EC,
LVD Directive 2006/95/EC
Fitting Back Plate –
Direct Wall Mounting
1. Position the back-plate (terminals
along top edge) with 100mm (min)
clearance to its right, 25mm (min)
above, 10mm (min) below and le.
Ensure that the supporting surface
will fully cover the back of the
programmer.
2. The ideal location would be 1.4M
above oor level, easily accessible,
reasonably lit and free from
condensation or temperature
extremes.
3. Oer the back plate to the wall in the
position where the programmer is to
be mounted remembering that the
back plate ts to the le hand side
of the programmer. Mark the xing
positions through the slots in the
backplate, drill and plug wall, then
secure back plate in position using
screws.
4. All necessary electrical connections
should now be made. Ensure that the
wiring to the back-plate terminals
leads directly away from the terminals
and is completely enclosed within
the back-plate aperture. Wire ends
must be stripped and screwed to the
terminals so that minimal bare wire is
showing.
be used to secure the unit to the wall.
2. All necessary electrical connections
should now be made. Ensure that the
wiring to the back-plate terminals
leads directly away from the terminals
and is completely enclosed within
the back-plate aperture. Wire ends
must be stripped and screwed to the
terminals so that minimal bare wire is
showing.
New Installations
Example circuit diagrams for typical
installations are shown over. These
diagrams are schematic and should be
used as a guide only. Please ensure that
all installations comply with the current
IEE regulations.
For reasons of space and clarity not
every system has been included and
the diagrams have been simplied, for
instance some Earth connections have
been omitted.
Other control components shown in
the diagrams i.e. Valves, Room Stats
etc. are general representations only.
However the wiring detail can be applied
to the corresponding models of most
manufacturers.
Continued Over...
If the unit is tted to a metal surface, IT IS
ESSENTIAL that the metal be earthed.
DO NOT use a surface mounting box.
No earth connection is required as the
product is double insulated but ensure
continuity of earth throughout the system.
Fitting Back Plate –
Wiring Box Mounting
1. Fix the wall-plate to a ush mounting
single conduit box type UA1 (BS4662)
using M3.5 x 14 screws. Take care
to ensure the opening is adequate
and will allow mounting of the unit
onto the base plate. The use of glue,
mastic, or other sealants MUST NOT
Page 4
New Installations
Cylinder and Room Thermostat Key:
C=Common Call = Call for heat or break on rise SAT = Satiseld on rise N= Neutral
Fitting The Programmer
Loosen the two retaining screws on the
bottom of the back plate.
Now t the programmer to the back plate,
ensuring the lugs of the
back plate engage with the
slots on the programmer.
Swing the bottom of the
programmer into position
ensuring the connection
pins on the back of the unit
locate into the terminal
slots in the back plate.
Tighten the two screws to x the unit
securely.
Commisioning
Switch on mains supply. Referring to the
user guide:
Existing Installations
1. Remove old programmer from its
back plate mounting loosening any
securing screws as dictated by its
design.
2. Check compatibility of existing back
plate & wiring arrangement with that
of the new programmer. See online
Programmer Compatibility Guide for
direction.
3. Make all necessary changes to back
plate & wiring arrangement to suit
new programmer
Electrical Connections
1. Use the buttons to ensure correct
product functionality.
2. Set timing and programme details
in accordance with customer
requirements.
3. Normally unit will be le with channel
in ‘Auto’ mode.
4. Leave these installation instructions
with customer for reference.
In the interests of continuous product
improvement we reserve the right to alter
designs, specications and materials
without prior notice and cannot accept
liability for errors.
SERVICE AND WARRANTY
Your product is not user serviceable. PLEASE DO NOT TRY TO DISMANTLE THE UNIT.
This product is guaranteed by your supplier for 5 years from the date of manufacture. If it should become defective please contact your
installer or supplier for a replacement unit or visit www.sangamo.co.uk/returns
This product must meet Waste Electronic and Electrical Equipment Regulations (WEEE) for suitable environmental recycling, recovery and/
or disposal. End of life products should be handled in line with local regulations. Alternatively return end of life product to Sangamo for
correct disposal.
CUSTOMER CARE POLICY
As part of Sangamo’s continuous improvement program, the company operates a Customer Care policy. This means we welcome your
comments and complaints, as it can help us to improve our services to you, our customer.
Due to our policy of continuous product improvement and development, the specications in this guide may be subject to change without
prior notice.
143794 Issue C
If you have a problem or require any
further information please contact our
technical team on:
01475 745131
Sangamo Limited
Industrial Estate, Port Glasgow,
Renfrewshire, PA14 5XG
Tel 01475 745131
Fax: 01475 744567
Email: enquiries@sangamo.co.uk
Web: www.sangamo.co.uk
WEE/JH0069TY
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.