Choice PR2n - 2 Channel Programmer
Installation Instructions
Pre-Installation Set Up
Before installing, set the bank of 4 DIP
Switches on the back to congure the unit
according to the chart below:
Pumped
24Hr
2 on/offs 3 on/offs
DIP Switches Shown in Factory
1 2
3
4
Default Positions. (black = raised actuator
of switch)
PUMPED allows independent control of
CH and HW.
GRAVITY does not allow CH without HW
but can provide HW without CH.
24 Hr Runs same programme every day.
5/2 Day Allows dierent on/o times at
weekend.
7 Day Allows dierent on/o times every
day.
Installation Safety Notes
This unit must be installed by a suitably
qualied person in accordance with the
latest IEE Wiring Regulations.
Isolate mains supply before commencing
installation. Please read all installation
instructions before proceeding.
Ensure that the xed wiring connections to
the mains supply is via a fuse rated at not
more than 3 amps and a class ‘A’ switch
having a contact separation of a minimum
of 3mm in all poles. The recommended
cable sizes are 1.0mm2 or 1.5mm
If the unit is tted to a metal surface, IT IS
ESSENTIAL that the metal be earthed.
DO NOT use a surface mounting box.
Gravity
7 Day
5/2 Day
2
Technical Data
Power Supply: 230V AC, 50Hz
Operating Temperature: 0°C to 40°C
Switch Rating: 230V AC, 2(1)A per channel
Contact Type: 1B , Micro-Disconnection
Battery Type: Lithium Cell CR2032
Enclosure Protection: IP30
Plastics: Thermoplastic, ame retardant
Insulation Class: Double
Wiring: For xed wiring only
Backplate: Industry standard
Dimensions: 140mm x 87mm x 37mm
Clock: 12 hour am/pm, 1 minute resolution
Summer/Winter time change: Automatic
Clock Accuracy: +/- 1.5 sec/day
Program Cycle: 24hr, 5/2day or 7day selectable.
Program On/os per day: 2on/o, 3on/o selectable
Program Resolution: 10mins
Program Selection: Auto, On all day, On constant, O
Program Override: +1,2 or 3 Hr, Boost & Advance to next operation
Heating System: Pumped, Gravity selectable
Complies with : EN60730-1, EN60730-2.7,
EMC Directive 2004/108/EC,
LVD Directive 2006/95/EC
No earth connection is required as the
product is double insulated but ensure
continuity of earth throughout the system.
Fitting Back Plate –
Direct Wall Mounting
1. Position the back-plate (terminals
along top edge) with 100mm (min)
clearance to its right, 25mm (min)
above, 10mm (min) below and le.
Ensure that the supporting surface
will fully cover the back of the
programmer.
2. The ideal location would be 1.4M
above oor level, easily accessible,
reasonably lit and free from
condensation or temperature
extremes.
3. Oer the back plate to the wall in the
position where the programmer is to
be mounted remembering that the
back plate ts to the le hand side
of the programmer. Mark the xing
positions through the slots in the
backplate, drill and plug wall, then
secure back plate in position using
screws.
4. All necessary electrical connections
should now be made. Ensure that the
wiring to the back-plate terminals
leads directly away from the terminals
and is completely enclosed within
the back-plate aperture. Wire ends
must be stripped and screwed to the
terminals so that minimal bare wire is
showing.
Fitting Back Plate –
Wiring Box Mounting
1. Fix the back-plate to a ush mounting
single conduit box type UA1 (BS4662)
using M3.5 x 14 screws. Take care
to ensure the opening is adequate
and will allow mounting of the unit
onto the back-plate. The use of glue,
mastic, or other sealants MUST NOT
be used to secure the unit to the wall.
2. All necessary electrical connections
should now be made. Ensure that the
wiring to the back-plate terminals
leads directly away from the terminals
and is completely enclosed within
the back-plate aperture. Wire ends
must be stripped and screwed to the
terminals so that minimal bare wire is
showing.
New Installations
Example circuit diagrams for typical
installations are shown over. These
diagrams are schematic and should be
used as a guide only.
Please ensure that all installations comply
with the current IEE regulations.
For reasons of space and clarity not
every system has been included and
the diagrams have been simplied, for
instance some Earth connections have
been omitted.
Other control components shown in
the diagrams i.e. Valves, Room Stats
etc. are general representations only.
However the wiring detail can be applied
to the corresponding models of most
manufacturers.
Continued Over...

New Installations
Cylinder and Room Thermostat Key:
C=Common Call = Call for heat or break on rise SAT = Satiseld on rise N= Neutral
Electrical Connections
3A
Fitting The Programmer
Loosen the two retaining screws on the
bottom of the back plate.
Now t the programmer to the back
plate, ensuring the lugs of the back plate
engage with the slots on
the programmer.
Swing the bottom of the
programmer into position
ensuring the connection
pins on the back of the unit
locate into the terminal
slots in the back plate.
Existing Installations
1. Remove old programmer from its back plate mounting loosening any securing
screws as dictated by its design.
2. Check compatibility of existing back plate & wiring arrangement with that of the
new programmer. See online Programmer Compatibility Guide for direction.
3. Make all necessary changes to back plate & wiring arrangement to suit new
programmer
SERVICE AND WARRANTY
Your product is not user serviceable. PLEASE DO NOT TRY TO DISMANTLE THE UNIT.
This product is guaranteed by your supplier for 5 years from the date of manufacture. If it should become defective please contact your
installer or supplier for a replacement unit or visit www.sangamo.co.uk/returns
This product must meet Waste Electronic and Electrical Equipment Regulations (WEEE) for suitable environmental recycling, recovery and/
or disposal. End of life products should be handled in line with local regulations. Alternatively return end of life product to Sangamo for
correct disposal.
CUSTOMER CARE POLICY
As part of Sangamo’s continuous improvement program, the company operates a Customer Care policy. This means we welcome your
comments and complaints, as it can help us to improve our services to you, our customer.
Due to our policy of continuous product improvement and development, the specications in this guide may be subject to change without
prior notice.
Tighten the two screws to x the unit
securely.
Commisioning
Switch on mains supply. Referring to the
user guide:
1. Use the buttons to ensure correct
product functionality.
2. Set timing and programme details
in accordance with customer
requirements.
3. Normally unit will be le with channel
in ‘Auto’ mode.
4. Leave these installation instructions
with customer for reference.
In the interests of continuous product
improvement we reserve the right to alter
designs, specications and materials
without prior notice and cannot accept
liability for errors.
If you have a problem or require any
further information please contact our
technical team on:
01475 745131
Sangamo Limited
Industrial Estate, Port Glasgow,
Renfrewshire, PA14 5XG
Tel 01475 745131
Fax: 01475 744567
Email: enquiries@sangamo.co.uk
Web: www.sangamo.co.uk
143793 Issue C
WEE/JH0069TY