Technical Data
Power Supply: 230V AC, 50Hz Operating Temperature: 0°C to 35°C Total Switch Rating: 230V AC, 6(2)A Contact Type: 1B , Micro-Disconnection (Voltage Free) Battery Type: Lithium Cell CR2032 Enclosure Protection: IP30
Plastics: Thermoplastic, ame retardant
Insulation Class: Double
Wiring: For xed wiring only Backplate: Industry standard Dimensions: 140mm x 87mm x 37mm
Clock: 12 hour am/pm, 1 minute resolution BST/GMT time change: Automatic
Clock Accuracy: +/- 1 sec/day Program Cycle: 24hr, 5/2day or 7day selectable. Program On/offs per day: 2on/off, 3on/off selectable
Program Resolution: 10mins
Program Selection: Auto, On all day, On constant, Off Program Override: +1,2 or 3Hr, Advance Heating System: Pumped, Gravity selectable Complies with : EN60730-1, EN60730-2.7, EMC Directive 2004/108/EC,
LVD Directive 2006/95/EC
Fit & forget...
Pre-Installation Set Up
Before installing, set the bank of 4 DIP Switches on the back to
congure the unit according to the
chart below:
DIP Switches Shown in Factory Default
Positions. (black = raised actuator of
switch)
PUMPED allows independent control of CH and HW.
GRAVITY does not allow CH without HW but can provide HW without CH.
24 Hr Runs same programme every day.
5/2 Day Allows different on/off times at
weekend.
7 Day Allows different on/off times every day.
Installation Safety Notes
This unit must be installed by a suitably qualied person in accordance with the latest IEE Wiring Regulations.
Isolate mains supply before
commencing installation. Please read all installation instructions before proceeding.
Ensure that the xed wiring
connections to the mains supply
is via a fuse rated at not more than 6 amps and a class ‘A’ switch
having a contact separation of
a minimum of 3mm in all poles. The recommended cable sizes are
1.0mm2 or 1.5mm
2
Fitting Back Plate – Direct Wall Mounting
1. Position the wall-plate (terminals along top edge)
with 60mm (min) clearance to its right, 25mm (min) above,
90mm (min) below. Ensure
that the supporting surface will fully cover the back of the
programmer.
2. The ideal location would be
1.4M above oor level, easily accessible, reasonably lit and free from condensation or temperature extremes.
3. Offer the back plate to the
wall in the position where the
programmer is to be mounted
remembering that the back
plate ts to the left hand side of the programmer. Mark the xing positions through the slots in the backplate, drill and
plug wall, then secure back
plate in position using screws.
4. All necessary electrical connections should now be made. Ensure that the wiring
to the wall-plate terminals
leads directly away from the terminals and is completely enclosed within the wall-plate
Fitting Back Plate – Wiring Box Mounting
1. Fix the wall-plate to a ush mounting single conduit box
type UA1 (BS4662) using
M3.5 x 14 screws. Take care to ensure the opening is adequate and will allow mounting of the unit onto the base plate. The
use of glue, mastic, or other
sealants MUST NOT be used to secure the unit to the wall.
2.
All necessary electrical
connections should now be made. Ensure that the wiring
to the wall-plate terminals
leads directly away from the terminals and is completely enclosed within the wall-plate aperture. Wire ends must be stripped and screwed to the
terminals so that minimal bare
wire is showing.
aperture. Wire ends must be stripped and screwed to the
terminals so that minimal bare
wire is showing.
If the unit is tted to a metal
surface, IT IS ESSENTIAL that
the metal be earthed.
DO NOT use a surface mounting
box.
No earth connection is required as the product is double insulated
but ensure continuity of earth
throughout the system.
New Installations
Example circuit diagrams for typical installations are shown below. These diagrams are schematic and should be used as a guide only.
Please ensure that all installations comply with the current IEE
regulations.
For reasons of space and clarity not every system has been included and the diagrams have been simplied, for instance some Earth connections have been omitted.
Other control components shown
in the diagrams i.e. Valves,
SERVICE AND WARRANTY
Your product is not user serviceable. PLEASE DO NOT TRY TO DISMANTLE THE UNIT. This product is guaranteed by your supplier for 5 years from the date of manufacture. If it should become defective please contact your installer or supplier for a replacement unit or visit www.sangamo.co.uk/returns
This product must meet Waste Electronic and Electrical Equipment Regulations (WEEE) for suitable environmental recycling, recovery and/or disposal. End of life products should be handled in line with local regulations. Alternatively return end of life product to Sangamo for correct disposal.
CUSTOMER CARE POLICY
As part of Sangamo’s continuous improvement program, the company operates a Customer Care policy. This means we welcome your comments and complaints, as it can help us to improve our services to you, our customer.
Due to our policy of continuous product improvement and development, the specications in this guide may be subject to change without prior notice.
Sangamo Limited
Industrial Estate, Port Glasgow,
Renfrewshire, PA14 5XG
Tel 01475 745131
Fax: 01475 744567
Email: enquiries@sangamo.co.uk
Web: www.sangamo.co.uk
WEE/JH0069TY
143704 Issue B
If you have a problem or require any further information please contact our technical team on:
01475 745131
RoomStats etc are general representations only. However the wiring detail can be applied to the corresponding models of most manufacturers.
Cylinder and Room Thermostat Key:
C=Common Call = Call for heat or break on rise SAT = Satiseld on rise N= Neutral
Existing Installations
1. Remove old programmer from its back plate mounting loosening any securing screws as dictated by its design.
2. Check compatibility of existing back plate & wiring arrangement with that of the new programmer. See online Programmer Compatibility Guide for direction.
3. Make all necessary changes to back plate & wiring arrangement to
suit new programmer
Electrical Connections
Fitting The Programmer
Loosen the two ‘captive’ retaining
screws on the bottom of the back
plate. Now t the programmer
to the back plate, ensuring the lugs of the back plate engage with the slots
on the programmer.
Swing the bottom of the programmer into position ensuring the connection pins on the back of the unit locate into the terminal slots
in the back plate. Tighten the two ‘captive’ screws to x the unit securely.
Commisioning
Switch on mains supply. Referring to the user guide:
1. Use the buttons to ensure correct product functionality.
2. Set timing and programme details in accordance with customer requirements.
3. Normally unit will be left with channel in ‘Auto’ mode.
4.
Leave these installation instructions with customer for
reference.