
ASSEMBLY AND INSTALLATION
INSTRUCTIONS
TO AVOID RISK OF ELECTRICAL SHOCK, BE SURE TO SHUT OFF
WARNING:
NOTES: 1. Before installing, consult local electrical codes for wiring and grounding requirements.
2. READ AND SAVE THIS INSTRUCTION.
Hardware Package (included):
Mounting Strap (A)
Screw (E)
Support Rod(I)
Installation Steps
Turn off the power at fuse or circuit box.
Mounting Screw (B)
Wire Connector (F)
POWER WHILE INSTALLING OR SERVICING THIS FIXTURE.
Outlet Box
Wire Connector (F)
Screw(E)
Green Grounding Screw (C)
Green Grounding
Screw (C)
Strain Relief(G)
Lock Nut (D)
Ball Nut (H)
Mounting Strap (A)
Lock Nut (D)
Mounting Screw (B)
Strain Relief (G)
Canopy
Hex Nut
Ball Nut(H)
Cord(A)
D(3/8")
C(3")
1. Unscrew two ball nuts, and then remove the mounting strap from the
canopy.
2. Thread the cord through the canopy and the strain relief. Measure the
desired length of the cord (A) from the canopy to the shade and
Leave additional 9" cord (B) above the canopy(include the canopy).
And then cut off the unnecessary cord.(See Fig.1)
3. Adjust the strain relief at 9" position from the top of the cord.
4. Mark the 3" cord (C) from the top of the cord (B). Use a knife to peel
off the insulation of the cord (C) carefully to show the 3 inside wires
out. (See Fig. 1)
Note : Cutting too deep may cut off three inside wires and
destroy the insulation surface of the three inside wires.
5. Peel off the 3 wires from the top about 3/8" long(D) to expose the
copper for wiring.
6. Attach the mounting strap to the outlet box by using two mounting screws.
7. Pull out the source wires from the outlet box. Make wire connections
using wire connectors as follow:
---Connect the hot wire (usually black insulation) from the fixture to the
black wire from the power source.
---Connect the neutral wire (usually white insulation) from the fixture to
the white wire from the power source.
---Attach the fixture grounding wire (usually green insulation or bare wire)
to the mounting strap with the green grounding screw, and then connect
it to the house grounding wire with the wire connector.
Carefully put the wires back into the outlet box.
Support Rod(I)
Fixture
Glass
Shade
Bulb Type A Max.60W
(not included)
B(9")
A
Fig.1
8. Pull the cord (A) down slightly until the strain relief touches the hex nut .
Attach the canopy to the mounting strap by inserting two screws, and then secure it with two ball nuts.
Note: Adjust the strain relief can decrease or increase the length of cord exposing outside.

9. Attach the glass shade to the fixture,secure it with three support rods.
10. Instal 1X60W Max medium base bulb. See relamping label at socket area or packaging for maximum allowed
wattage.
Turn on the power at fuse or circuit box.
The following parts are available for re-order if damaged or missing.
Spare Parts List:
Mounting Strap (A)
Screw (E)
Support Rod(I)
Mounting Screw (B)
Wire Connector (F)
Green Grounding
Screw (C)
Strain Relief(G)
Lock Nut (D)
Ball Nut (H)
Mounting Hardware
Glass Shade
(1PC)
B
A: 5"
B: 11.5"
A