Sandia Aerospace SAFE 128 User Manual

SAFE 128
Avionics Cooling Fan With Fault Detection
1.1 INTRODUCTION
1.1 PRODUCT DESCRIPTION
The SAFE 128 is an avionics cooling fan that provides an operating indication. When the fan is normally operating, this output is at low impedance. The output goes to high impedance whenever the RPM of the motor drops below a preset threshold, signaling the connected avionics of the reduction in cooling from the SAFE 128.
1.2 TECHNICAL CHARACTERISTICS
1.2.1 PHYSICAL CHARACTERISTICS
Width 2.36” Height 2.87” Depth 1.44” (inc. pins) Weight 0.25 lb
INSTALLATION INSTRUCTIONS
1.2.2 O
PERA TIONAL CHARACTERISTICS
Operating V oltage 22-31Vdc Current Operating .100 Amps Nominal
Air Flow (No Load) 20 CFM (10CFM @ .08” H2O) Operating Temp -20 to +55 oC Max Operating Altitude 55,000 Feet
1.2.3 CERTIFICATION
FAA-PMA PQ0894SW Diamond DA40 DO 160D [F1]BAA[S2R2(B2,M)]XXXXXXZBAZA[XX]M[XXXX][XX]XX
SANDIA aerospace
Albuquerque, New Mexico www .sandia.aero
Figure 1
Dimensional Drawing
Start-up <.250 Amps
305468-00-IS Rev B 09/26/06 DRN 287
2.0 INSTALLATION PROCEDURES
2.1 G
ENERAL
The SAFE 128 is supplied with a mounting connector and four contacts. Only three contacts are required and the spare one is provided in case one is destroyed during installation. The SAFE 128 is also shipped with a mating connector attached to the unit itself. This is to protect the pins during transit. This connector can be discarded once the unit is received or may be retained to cover the pin in case return shipment to the factory is necessary. The SAFE 128 is mounted with four (4) number 6 or 8 screws.
2.2 E
QUIPMENT REQUIRED
2.2.1 Supplied SAFE 128 System Includes: SAFE 128 Fan 305468-00
2.2.1 R
EQUIRED BUT NOT SUPPLIED
Four (4) Number 6-32, 8-32 or equivalent mounting screws
2.3 MOUNTING
The SAFE 128 mounts with four number (4) 6-32 or 8-32 or equivalent machine screws. Be sure to observe the direction of airflow .
Installation Kit 305477-00 Mating Connector 305479-03 Mating Pins 305478
2.4 ELECTRICAL
The SAFE 128 operates on 28Vdc. It will provide a low on Fan Fail (center pin) of the connector when operating normally. When airflow drops to 60% of nominal, as determined by fan RPM, Fan Fail will output a high. An external pull-up is required. Power to the SAFE 128 can be supplied from the aircraft buss or from the unit to be cooled if an ouput is available. If connected to the aircraft buss, the SAFE 128 should be pro­tected by a .5 amp fuse or breaker.
*or equivalent
2.5 C
ALIBRATION
No calibration of the SAFE 128 is required. The unit can be tested by slowing the fan manually and observing a high present on the Fan Fail pin. Allow the fan to return to normal speed and observe a low on the Fan Fail pin.
Gnd
Fan
Pwr
Fail
noitpircseDrerutcafunaMrebmuNseireSrebmuNtraP.fnaMrebmuNtraPaidnaS
gnisuoHrotcennoCxeloM59627303-1-2230-974503
tcatnoCpmirCxeloM95724110-05-80874503
looTrepmirCdnaHxeloMANC2622RCro5810-10-11*AN
looTnoitcartxExeloMAN2200-30-11
looTnoiitresnIxeloMAN0000-21836*AN
Mating Connector and Contact Information
*AN
2.6 CONTINUED AIRWORTHINESS
Maintenence of the SAFE 128 is on condition only. No scheduled maintenance is required.
305468-00-IS Rev B 09/26/06 DRN 287