Samyung SRG-3150DN User guide

RF Exposure Warning :
The radiated output power of this device is below the FCC
radio frequency exposure limits. Nevertheless, the device should be used in such a manner that the potential for human contact during normal operation is minimized. In order to avoid the possibility of exceeding the FCC radio frequency exposure limit, human proximity to the antenna should not be less than 20cm during normal operation.
Warning
Information to user
The user’s manual or instruction manual for an intentional
or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. In cases where the manual is provided only in a form other than paper, such as on a computer disk or over the Internet, the information required by this section may be included in the manual in that alternative form, provided the user can reasonably be expected to have the capability to access information in that form.
1
Contents
SRG-3150DN How to operate basic function and Distress transmitting
1. Set MMSI ID ................................................................................................................. 5
1.1. Self-ID ........................................................................................................ 5
2. SSB mode ....................................................................................................................... 5
2.1. Channel Selection ................................................................................ 5
2.2. Frequency Selection ............................................................................ 5
2.3. TX, RX ........................................................................................................ 5
3. DSC mode...................................................................................................................... 5
3.1. Channel Selection ................................................................................ 5
3.2. Frequency Selection ............................................................................ 5
3.3. Call .............................................................................................................. 6
3.4. DSC Message RX Auto Reply ......................................................... 6
4. Distress transmit ......................................................................................................... 6
How to use SN-100 NBDP Terminal
1. Selection of Channel ................................................................................................. 6
2. Selection of Frequency ............................................................................................ 6
3. ARQ mode ..................................................................................................................... 6
4. FEC mode ....................................................................................................................... 6
Chapter 1. Overview ............................................................................................................. 7
1.1. Features ....................................................................................................................... 7
1.2. Basic Components .................................................................................................. 8
Chapter 2. Specifications ..................................................................................................... 9
2.1. General specification ............................................................................................. 9
2.2. MF/HF Transmitter .................................................................................................. 9
2.3. MF/HF Receiver........................................................................................................ 9
2.4. DSC (Digital Selective Calling) W/K Receiver ..........................................10
2.5. MF/HF Control .......................................................................................................10
2.6. Digital Selective Calling (DSC) ........................................................................10
2.7. Narrow band direct Printing (NBDP) ...........................................................11
2.8. Printer (DPU-414)..................................................................................................11
2.9. Printer (OKI) .............................................................................................................11
Chapter 3. Power Supply ................................................................................................... 12
3.1. Power On ..................................................................................................................12
3.2. Operation by AC power.....................................................................................12
3.3. Operation by DC (BATTERY) power ..............................................................12
3.4. BATTERY Charging ................................................................................................12
Chapter 4. Front Panel ....................................................................................................... 13
4.1. About Button, Knob, Lamp ..............................................................................13
4.2. LCD display ..............................................................................................................14
4.3. LCD display flow ....................................................................................................15
Chapter 5. SSB (TEL) mode ............................................................................................... 16
5.1. SSB Mode .................................................................................................................16
5.2. SSB Menu .................................................................................................................16
(1) Scan Type Set ........................................................................................16
(2) Scan Channel Set .................................................................................16
(3) Scan Frequency Set .............................................................................16
SRG-3150DN Rev.1.1(080409)
2
(4) SQL Set .....................................................................................................16
(5) LCD Contrast Set ..................................................................................17
(6) Tx Power Set ...........................................................................................17
(7) Manual Tuning.......................................................................................17
(8) ATU – Version (ATU Program Version) .......................................17
(9) Remote Set .............................................................................................17
(10) System Set ............................................................................................17
5.3. Additional Functions (ITU Channel, AM mode, Etc.,) ...........................18
Chapter 6. Digital selective calling (DSC) mode .............................................................. 19
6.1. The selection of DSC mode .............................................................................19
6.2. DSC menu display ................................................................................................19
(1) Distress msg edit .................................................................................19
(2) Individual msg edit. ............................................................................20
(3) Group msg edit.....................................................................................21
(4) Geography msg edit .......................................................................22
(5) Auto/Semi-AT msg edit ....................................................................25
(6) Dist ack/rly msg edit ..........................................................................26
(7) Ordinary ack msg edit .......................................................................28
(8) Display and print msg .......................................................................28
(9) System Set ...............................................................................................28
Chapter 7. Transmitter of distress signal......................................................................... 32
7.1. Test of Distress alert signal ..............................................................................32
Chapter 8. RX of Distress & general call .......................................................................... 33
8.1. RX of Distress Alarm ...........................................................................................33
8.2. General call RX .......................................................................................................34
Chapter 9. How to use print ............................................................................................... 35
9.1. DPU-414 Printer ....................................................................................................35
9.2. OKI Printer................................................................................................................35
Chapter 10. How to use SD-250(Alarm box) .................................................................... 36
10.1. Distress transmitting .........................................................................................36
10.2. In case of receiving distress signal ............................................................36
10.3. Operation by DC (Battery) .............................................................................36
Chapter 11. How to use SP-1250ADC ............................................................................... 36
11.1. Specification .........................................................................................................36
11.2. Input power shift ................................................................................................36
11.3. How to Charge ....................................................................................................36
11.4. In case of over current ....................................................................................36
Chapter 12. Circuit explain ................................................................................................ 37
12.1. Overview of SRG-3150DN ..............................................................................37
12.2. CONTROL CIRCUIT (T-1110) .........................................................................38
(1) MF/HF RX Circuit..................................................................................38
(2) MF/HF TX Circuit ..................................................................................38
(3) Local Synthesizer Circuit ...................................................................39
(4) Power Supply Circuit ..........................................................................39
(5) Control Circuit .......................................................................................40
12.3. MH/HF Transmitting Filter Circuit (T-1101) ............................................40
12.4. W/K Receiving Circuit (T-1112) ....................................................................41
12.5. Power Amplifier Circuit (T-1113) .................................................................41
3
12.6. Front Panel (T-1114) .........................................................................................41
12.7. Function Diagram of Rear Side ...................................................................42
Chapter 13. NBDP Terminal ............................................................................................... 43
13.1. NBDP Terminal Main Unit ..............................................................................43
13.2. Initial Display of Telex (NBDP) mode ........................................................43
(1) Initial screen function explanation ...............................................43
(2) Initial screen function button explanation ...............................43
(3) Control function in Keyboard .........................................................44
13.3. SettingUpTX/RX Frequency ...........................................................................44
(1) Setting TX frequency ..........................................................................44
(2) Setting Rx frequency ..........................................................................44
(3) Coast Radio Station TX/RX frequency set up .........................44
(4) Setting TX/RX Freq. by calling channel .....................................44
13.4. [ARQ] mode ..........................................................................................................44
(1) Connecting with the other station by ARQ mode. ..............44
(2) Connecting specific station .............................................................45
(3) Communication in ARQ mode ......................................................45
(4) Transmitting file ....................................................................................46
(5) Transmitting of Macro Command ................................................46
13.5. [FEC] mode ............................................................................................................46
(1) Connecting the other station by Selective FEC mode. ......46
(2)
Connecting with the other station by collective FEC mode
. .......47
(3) Communication in FEC mode ........................................................47
(4) Receiving of FEC mode .....................................................................47
(5) Transmitting file ....................................................................................48
(6) Transmitting of Macro Command ................................................48
13.6. Other sea station or ship station edit & resister frequency ..........48
13.7. Station print (Counter party & Frequency print) ................................49
13.8. Registration of macro command ................................................................49
13.9. Editor mode ..........................................................................................................49
13.10. Initial setting of system set .........................................................................50
(1) Setting of [0. ARQ/FEC 4~ or 5~digit ID] ................................50
(2) Setting of [1. ARQ/FEC 9-digit ID] ...............................................50
(3) Setting of [2. Answer Back Code] ................................................50
(4) Setting of [3. Collective FEC Receiving] .....................................50
(5) Setting of [4. Maximum FEC Error Ratio] .................................50
(6) Selecting of [5. NAVTEX Station Selection] .............................51
(7) Selecting of [6. NAVTEX Message Selection] ..........................51
(8) Selecting of [7. NAVTEX ID Data Clear] ....................................51
(9) [8. ID Printing] set up ........................................................................51
(10) [9. Etc. Setting] set up .....................................................................51
13.11. NBDP test ............................................................................................................52
13.12. LCD Off .................................................................................................................52
Chapter 14. NBDP Terminal Circuit................................................................................... 53
14.1. Overview.................................................................................................................53
14.2. Connection board T-020 ................................................................................53
14.3. NBDP receiving unit (T-132) .........................................................................53
14.4. Local Synthesizer board (T-133) ..................................................................53
14.5. Power Circuit (T-025) ........................................................................................53
14.6. Function Diagram of Rear Side ...................................................................53
Chapter 15. Troubleshooting ............................................................................................. 54
4
15.1. Overview.................................................................................................................54
15.2. Measuring Instrument ......................................................................................54
15.3. Maintenance & repair of SRG-3150DN ...................................................54
(1) Antenna ....................................................................................................54
(2) Power Supply .........................................................................................54
(3) Transmitter ..............................................................................................54
(4) Receiver ....................................................................................................54
(5) DSC Receiver ..........................................................................................54
(6) Switch and Display ..............................................................................55
15.4. NBDP SN-100.......................................................................................................55
(1) Power Supply .........................................................................................55
(2) Screen Display .......................................................................................55
(3) NBDP Data Receiving .........................................................................55
(4) NBDP Data Transmitting ...................................................................55
15.5. Modulation of simple modulator ...............................................................55
15.6. Caution ....................................................................................................................55
Chapter 16. Circuit Diagram & External Diagram ............................................................ 56
5
SRG-3150DN How to operate basic function and Distress transmitting
1. Set MMSI ID
(Maritime Mobile Service Identity)
Press button and ON, It stop at the below
initial display,
Then input SELF ID or handle dial/key of the
front panel to be operated regularly.
< Initial Screen >
1.1. Self-ID
[DSC] mode / '9. SYSTEM SET' /
'1.Self ID set'
Ex) Input ID 111100000 :
Press any key on the initial screen
Press
to go to [DSC] mode
twice Press( )and then go
out to 'Main Menu'. (Indicated MMSI Number in the right side on the bottom)
2. SSB mode
2.1. Channel Selection
Press
select to the channel by dial [CH]
[ Ref. ] Press twice ( ) and
select to [CH]input channel with [No. button]
and then press .
to go to [SSB] mode
2.2. Frequency Selection
1)Press twice( )and select to [TX]
Input frequency by [No. button]
press .
2) Press twice ( )and select to [RX] Input frequency by [No. button]
press .
[ Ref. ] ☞☞☞ Missing frequency range, Cannot be
input with alarm sound.
2.3. TX, RX
1) TX
Can use it after inputting to the frequency TX/RX
that want to communicate.
Press to go to
[SSB] mode
input the frequency that want to communicate Press [Mike switch(PTT)] and communicate.
[ Ref. ] Don’t have a ATU Tunning date
valor of the first channel, ATU Tuning run automatically to the emergency TX(2,182 /
2,1875 / 4,2075 / 6,312 / 8,4145 / 12,477 / 16,8045 kHz).
2) Received gain adjustment
Be easy to hear on condition of low noise as down
GAIN and up VOLUME.
3. DSC mode
3.1. Channel Selection
Press
select to the channel by dial [CH]
[ Ref. ] Press twice ( ) and
select to the channel [CH] and input the wanted
channel by[Number]and then press .
3.2. Frequency Selection
Press twice ( ) and select [TX]
Input the wanted frequency by [No. button]
press .
[ Ref. ] Missing frequency range, Cannot be
input with alarm sound.
to go to [DSC] mode
6
3.3. Call
Press
select to the channel by dial [CH]
3.4. DSC Message RX Auto Reply
When receive DSC message and Auto ACK on, can
work automatic answer.
When receive DSC but Auto ACK off and then
don’t work automatic answer.
(1) How to set
[DSC] mode press / ‘9.SYSTEM SET’
/ ‘0.Etc Set’ / ‘4.Auto Ack’ and finished setting.
to go to [DSC] mode
How to use SN-100 NBDP Terminal
1. Selection of Channel
1.1. Change [CH] on screen
Select wanted channel by [No. button] and press [Enter]
1.2. Press [F6]
Input the wanted channel by [No. button] Press [Enter]
2.
Selection of Frequency
2.1. TX
Press[F7]
input the wanted communicate frequency by
[Number] press[Enter]
4. Distress transmit
4.1. Transmit signal(DISTRESS) by Emergency Transmitter KEY
(1) Hold on 3 seconds [DISTRESS] and then
transmit signal.
(2) If you don’t have any reply, flicker the red[DISTS]display as follow on screen and transmit channel from 1 to 6 after 4 minutes(3min.and 30sec ~ 4min.40sec.).
(3) Press and then stop to transmit.
2.2. RX
Press[F8]
input the wanted communicate frequency
[Number] press[Enter]
3. ARQ mode
Hold [F2], Select [ARQ] You can access to one
by ARQ MODE.
4. FEC mode
Hold [F2], Select [FEC] You can access to one by
FEC MODE.
7
Chapter 1. Overview
GMDSS(Global Maritime Distress and Safety
System) is an internationally recognized distress and radio communication safety system for ships replacing the previous ship to ship safety system, which relied on a manual Morse code system on 500 kHz and voice radiotelephony on Channel 16 and 2182 kHz. The GMDSS is an automated ship to shore system using satellites and digital selective calling technology. The GMDSS is mandated for ships internationally by the International Maritime Organization (IMO) Safety of Life at Sea Convention (SOLAS), 1974, as amended in 1988, and carries the force of an international treaty.
SRG-3150 and SN-100 are composed of MF/HF
transceiver, DSC, DSC W/K Receiver, NBDP, Automatic alarm telephone for suitable automatic digital communication at the distress and safety/normal situation. SN-100 uses being connected to Transceiver(SRG­3150DN), output sub-carrier signal to transmit NBDP data, displays the information on the display which is demodulated RX signal receiving from antennas.
SRG-3150DN frequency range :
TX : 1.6MHz~27.5MHz RX : 500kHz~29.99999MHz
Type of Frequency/Power :
J3E : 150W(HIGH)/100W(MID)/50W(LOW), F1B : 100W(HIGH&MID)/75W(LOW).
1.1. Features
(1) Possible Range
Because MF/HF Transceiver(SRG-3150DN), DSC
W/K Receiver, DSC, Distress alarm telephone is built in SRG-3150DN, You are able to use itself without NBDP terminal(SN-100). NBDP function is worked by connecting SN-100 terminal, However it is not available to use NBDP terminal only.
(2) Total Control System
SRG-3150DN is set up with the major modules
combined as one unit or circuits within a single cabinet. Thus, it is possible to rationalize the total control system by interlinking the respective module controls.
And narrow band direct printing is available by
connecting NBDP unit(SN-100) to SRG-3150DN simply.
(3) User Friendly
All general operation such as communication,
controls and monitoring, are performed by SRG­3150DN, NBDP Terminal and printer which is installed in a convenient place.
(4) Configuration
SRG-3150DN consists of one unit; therefore a
large space is not required for installation and operation.
SN-100 Terminal is able to use by connecting with
SRG-3150DN cable.
(5) Trustworthy Adopted new DDS (Direct Digital Synthesize) and improved the quality of sound, trustworthy, stability.
(6) Construction
In order to endure in bad condition of marine
environment, hard aluminum body is manufactured.
(7) External Shape
Channel, Frequency, Transmitting and receiving
conditions can be seen on large LCD at one sight. And each key is made by soft rubber material. It has stylish shape and makes you feel comfortable when you press the button, Further there is frequency sheet for users. SN-100 NBDP Terminal has large, thin, colorful LCD and convenient keyboard.
8
(I
nstallation
1.2. Basic Components
This equipment is composed of SRG-3150DN and SN-100(NBDP), each item is made by functional PCB and
sorted by standard and option.
<< Standard Components List >>
No.
1. MF/HF-DSC 송 수신기 SRG-3150DN 1set
(1) MAIN BOARD T - 1110 1
(2) TX FILTER T - 1101 1
(3) W/K RX T - 1112 1
(4) TX PA T - 1113 1
(5) KEY BOARD T - 1114 1
2. Automatic Antenna Tuner SAT-100 1
3. HAND MIC SM-1150 1
4. Accessory
5. User, Installation Manual SRG-3150DN(Eng) 1
<< Options Components List >>
No.
1. EMG Light EMG-Light 1
2. External Speaker SS-6000 1
Description Model Q’ty
SSB-A-C,SRG-2050D-PC
Description Model Q’ty
1set
Remark
SRG-3150DN
Assembly
(Installation material included)
Remark
3. Power Supply SP-1250ADC 1
4. NBDP Teminail SN-100 1set
(1) Connection Board T - 130 1
(2) NBDP 수신부 T - 132 1
(3) NBDP PLL T - 133 1
(4) 전원부 T - 025 1
(5) CPU Board G-1151 1
5. KEY Board SPR8695 1
6. MF/HF Distress Box SD-250 1 (SCN-16-5P included)
7. Printer DPU-414 1
8 WHIP ANT (TX) SAN-308 1 (8m)
9. WHIP ANT (RX) SAN-30R 1 (6m)
SN-100 Assembly
(Installation
material included)
material included)
(or OKI Printer)
9
Chapter 2. Specifications
2.1. General specification
This radio equipment SRG-3150DN has been
tested by the recommendation standard of IMO. (1) Power Supply (SP-1250ADC)
AC 100-120/200-240V, 50/60Hz, 6% single-phase, DC24V Power Supply : 1200VA (Max)
(2) Consumption Current: DC24V ±15%
Receiving: 2.5A, at transmitting: 15A (Max)
(3) Frequency Selection
a) ITU CHANNEL (Maritime Mobile) 271 b) 299 USER CHANNEL (Editable at the screen)
or set frequency directly by keyboard.
c) DSC CHANNEL 2187.5, 4207.5, 6312, 8414.5,
12577, 16804.5 kHz (FIB) is scan receiving all the time.
d) DSC Channel 13EA (Editable).
(4) Frequency Switching Time:
Between CHANNEL - within 5sec, Between BAND - within 15sec
(Including ANTENNA MATCHING TIME)
(5) Ambient Condition
Temperature : -15 ~ +55
Humidity: 95%, +55
Oscillation : Full amplitude 3.2mm at 5 ~ 12.5Hz Full amplitude 0.8mm at 12.5 ~ 25Hz Full amplitude 0.2mm at 25 ~ 50Hz (6) Dimensions (mm)
SRG-3150DN : 324(W) X 170(H) X 347(D)
SN-100 : 300(W) X 255(H) X 125(D) (7) Weight
SRG-3150DN about 8.1Kg
SN-100 about 5 Kg
SAT-100 about 3.4Kg
2.2. MF/HF Transmitter
(1) Type of Emission : J3E (USB), F1B (FSK) (2) Type of Communication
: SIMPLEX & SEMI DUPLEX (3) Frequency Range : (4) Continuous Operating:
Operating for over 8hrs with transmitting for 1minute, stand by for 4minutes.
(5) Output Power:
50 ohm loaded (MF/HF transmitter output) a) AC : 1.6MHz-27.5MHz 150WPEP b) DC : 1.6MHz-27.5MHz 75WPEP c) Power Reduction: 3steps
J3E : 50 / 100 / 150W F1B : 75 / 100 / 100W
(6) Frequency Deflection:
Below 10Hz (within 0.3ppm)
TX 1.6MHz - 27.5MHz, 10Hz STEP
(7) Number of Channels:
SSB x 299, ITU x 271, DSC x 19
(8) Modulation type:
Low power stage balanced modulation
(9) Occupied Bandwidth:
J3E …… within 3kHz , J2B within 0.5kHz
(10) Carrier Attenuation : 40dB or more (J3E) (11) Spurious Attenuation
J3E: 1.5 - 4.5 kHz 31dB or more
4.5 - 7.5 kHz 38dB or more
7.5 kHz or more 43dB or more
F1B: 138Hz 15dB or more
76Hz 31dB or more
500Hz 43dB or more
(12) Overall Frequency:
Deflection 6db max. At 350 - 2,700Hz (13) Overall Distortion and Noise : 20dB or more (14) Out Impedance : 50ohm (15) Input Low Frequency:
+10dB/-35dB, IMPEDANCE 600 ohm
2.3. MF/HF Receiver
(1) Type of Emission:
J3E (USB), H3E (only RX), F1B (FSK) (2) Reception method:
Up conversion double super heterodyne type
using phase-locked digital frequency synthesizer.
First intermediate frequency: 49.455MHz
Second intermediate frequency: 455 kHz (3) Frequency Range:
500 kHz - 29.99999MHz 10Hz STEP (4) Voice Output : Max 5.6W or more (5) Receiving Sensitivity:
SSB is less 3 at the 500KHz~29.9999MHz
i.e., SSB (S+N+D)/ (N+D) = 20dB, BAND width 3 kHz, Output 100mW
In case of DSC, NBDP Symbol error rate at a
receiver input voltage of 1 is less than 1 x 10-2
i.e., Receiving Mode: FSK, BAND width: 0.3 kHz
(6) 1 signal selectivity
a) 3 kHz FILTER (for SSB) in detailed features
The pass band below 6dB: 2.4 kHz ~ 2.8 kHz The pass band at an attenuation of 26dB is less
than ±1.7kHz
The pass band at an attenuation of 46dB is less
than ±1.9kHz
The pass band at an attenuation of 66dB is less
than ±2.1kHz
b) 0.3 kHz FILTER (for DSC, NBDP)
Below 6dB of the pass band is 270Hz ~ 300Hz Attenuation at ±380Hz is 30dB or more Attenuation at ±550Hz is 60dB or more
10
(7) Clearness: ±120Hz (8) Overall Distortion & Noise :
With an input voltage of 30uv, the ratio between an audio frequency output of 1000Hz and its unwanted component is more than 20db.
(9) AGC characteristics :
Change in audio frequency output for antenna between 3 and 100mV is 10db or less.
(10) Frequency Stability: within ±10Hz (11) Image frequency interference ratio :
Above 70dB
(12) Intermediate frequency interference ratio:
Above 80dB
(13) SPURIOUS RESPONSE : Above 70dB
In case of DSC, NBDP When a wanted signal of 10 and a 31.6 unwanted signal(excluding the range within
750Hz of the wanted signal) whose range of IF it's three times that of the wanted signal, the symbol error rate is less than 1 x 10-2.
(14) Selectivity Suppression : With a wanted signal
of 10 and an unwanted signal that is effect than 3kHz from the wanted signal, an unwanted
signal input voltage of 10m suppresses the wanted scanning output to 3db. In case of DSC, NBDP With a wanted signal of 10
and 1 unwanted signal 500hz from the wanted signal, the character error rate is less
than 1 x 10-2.
(15) Spurious Emission :
The power of emission from air antenna terminal is less than 4000.
(16) Nominal input load : 50 ohm unbalanced
2.4.
DSC (Digital Selective Calling)
W/K Receiver
(1) Type of Emission : F1B (2) Frequency : 2 187.5, 4 207.5, 6 312,
(3) Frequency Stability : within ±10Hz (4) SCANNING Reception :
Scanning reception of above frequencies is continued up to 2sec for each frequency and stop only when detects a 100 baud dot pattern.
(5) Receiving Sensitivity :
Character error rate is 1 x 10-2 or less at receiving input voltage 1.
(6) 1 signal selectivity
6dB bandwidth : 270 ~ 300Hz 30dB bandwidth : within ± 380Hz
60dB bandwidth : within ± 550Hz (7) Nominal input load : 50 ohm unbalanced (8) Display DSC received word
Maximum 256EA (Figure and word)
8 414.5, 12 577, 16 804.5 kHz
:
(9) SPURIOUS RESPONSE:
With a wanted signal of 10 and 31.6 zero modulated interference signal which excludes the
range within 750hz of the wanted signal, the character error rate is less than 1 x 10-2.
(10) Spurious emission:
The power of emission from air antenna terminal is less than 4000.
2.5. MF/HF Control
(1) Control Items :
MF/HF Transceiver, DSC, WATCH-KEEPING Receiver, Frequency Program.
(2) DISTRESS :
Transmitting 2187.5, 4207.5, 6312, 8414.5, 12577,
16804.5 kHz
(3) Miscellany :
DISPLAY, Remote Interface, NBDP terminal, ATU BOX, ALARM BOX, HAND MIC,
Printer, DIMMER (4) MAIN PROCESSOR : HD64F2506 (5) EEPROM : 24LC512 (6) Display : LCD BACK-LIGHT DISPLAY (7) INTERFACE
RS-232 INTERFACE : 1 CHANNEL (NBDP)
RS-422/232 INTERFACE : 1 CHANNEL (GPS)
PRINTER INTERFACE : 1 CHANNEL
(CENTRONICS INTERFACE)
2.6.
(1) PROTOCOL : (2) EMISSION : F1B/J2B 100BAUD (3) Modulator : Output frequency 1700Hz ±85Hz Output max LEVEL +10dBm
(4) Demodulator : Input frequency 1700Hz ±85Hz Input LEVEL -20dBm ~ +5dBm
(5) Processor:
(6) DSC Memory Function
Digital Selective Calling (DSC)
CCIR recommendation 493-3 & 541-2
(600 ohm Unbalance/Balance)
(600 ohm Unbalance/Balance)
CCIR recommendation 493-3ERROR mark (10 steps)
Correct CLOCK transmitting CLOCK frequency 14,000 KHz CLOCK stability within 5 x 10-6.
Distress Receipt : 50EA
Ordinary : 50EA
Transmit message : 100EA
11
2.7.
(1) Protocol :
(2) Calling mode :
(3) Operating mode :
(4) Status Display :
(5) Code :
(6) Memory : 16M (7) SYSTEM PARAMETER:
(8) Center frequency : 1700Hz (9) Frequency SHIFT width: ±85Hz (10) Modulation Speed :
(11) Modulation: phase continuity AFSK (12) Frequency Deflection: within 0.5Hz (13) Modulation Input :
(14) Modulation Output:
Narrow band direct Printing (NBDP)
CCIR recommendation 625.476-4.490491.492-3 & CCIR F130
Individual and group calling with 5 digits and 9 digits select call number.
ARQ (Auto Repetition Request) CFEC (Collective Forward ERROR correction) SFEC (Selective Forward ERROR Correction)
POWER ON, STAND-BY, CALLED, CALLING, FREE. SIGNAL, ARQ, CFEC, SFEC, SEND, RECEIVER, PHASING, REPHASING, REPEAT, ERR
7-bit CORD 4B/3Y constant ratio mark signal (B:1785Hz, Y:1615Hz)
OPERATOR DATA is saved at FLASH DISK PROGRAMING and back-up.
100BAUD (ARQ, FEC MODE)
0dBm, 600ohm Unbalance/Balance
0dBm, 600ohm Unbalance/Balance
2.8. Printer (DPU-414)
(1) Specifications
Typing : Thermal serial dot matrix
Total Dots : 9 x 320 dot / line
Composition of Dots: 9 x 7 dots wide
Internal Dots : 1 dot
Typing Quantity :
40letters (Standard) 80letters (Shortened)
Typing Direction : Single / Both Logical seek
(2) Bit-image graphics mode
Total Dots : 8 x 320 dot / line
Typing Direction : Single Logical seek
Typing width : 89.6mm
Typing speed : Max 52.5cps (Standard
Max 80cps (Shortened) (3) Ambient
Temperature: 0 ~ 40
Diameter : 48mm
Length : about 28m
(5) Etc
Power Supply : DC 6.5 ~ 13.6V
Dimensions :160mmx 170mmx 66.5mm
Weight : about 580g
Durability : about 500,000 lines
("8" 40letters continuously) (Color thickness 100)
2.9. Printer (OKI)
(1) Features
Printer Head : 9 pins
Speed (CPS) : 300CPS (Max speed)
240CPS (High speed) 50CPS (High quality)
Carriage width : 80letters (10CPI)
Graphic Resolution : 240X216DPI (Max)
Paper Space : From top 15mm (CUT SHEET)
From top 17mm (ROLL)
Interval between letters : 10, 12, 17CPI
Type of Font: Dark, Stress, Thick, Lean
Remember : 1 Line
(2) Paper
Dimensions : 241 ~ 254mm
Weight : 35 ~ 52 g/m
(3) Interface and Standardization
Standardization : micro line espon fx ibm
pro printer
Interface : centronics parallel
serial rs232c, rs422
(4) Reliability
Head Life : 2 billion letters
Ribbon Life : 3 million letters
MTBF : 6000hrs
(5) Miscellany
Power : DC +24V
Dimensions (HXWXD): 80mmX360mmX275mm
Weight : 4.5Kg
NOTE : DC available (10~30V DC)
2
Humidity: 30 ~ 80 RH(no condensation)
(4) Print Paper
Model No : TP411 - 28CL(TP-411L)
Width : 112mm
12
Chapter 3. Power Supply
3.1. Power On
(1) AC power plug put in plug receptacle, connect
the battery with rear socket.
(2) Check the indication of light on: AC IN, DC IN,
and DC OUT of front panel. (3) Connect cables of SRG-3150DN. (4) Switch AC and DC power on.
(5) Push the button.
3.2. Operation by AC power
When it comes to supply AC power to the main
unit, it works with AC power automatically. W/K LED displays the condition that 6 scanning frequency is working on DSC WKR of the transceiver. (Refer to "Operation of Distress Acknowledge Signal" for operation instructions, If DSC distress or alarm call rings.)
3.3.
When AC power is disconnected, the SRG-3150DN
switches to DC operation and [DC] LED on MF/HF control panel will light up automatically. When it is transmitted to DSC, AC signal will be changed to DC on upside of transceiver LCD display. Moreover, changing to DC mode will be displayed on downside of that. And receiving output is converted to LOW.
Operation by DC (BATTERY) power
3.4. BATTERY Charging
When connected to AC power, except of switch
on of transmitter power supply AMP power, the battery is automatically charged, a low current is supplied to maintain the rated battery voltage. The charge mode indicator between automatic and normal is by the charge switch on the system cabinet.
(1) AUTO MODE: When the battery is out, charged automatically, Full time charged is set general mode.
(2) NORMAL MODE: It is charged battery, regardless battery is status. To use battery longer, it is required to maintain properly for battery. Maintaining battery according to the instruction manual.
(3) OFF MODE: Set the middle of switch between AUTO & NORMAL.
13
Chapter 4. Front Panel
4.1. About Button, Knob, Lamp
< SRG-3150DN Main Unit >
. KEY Panel
. Front Panel(LCD) - Mode / Frequency / Channel
/ Other function.
. Internal Speaker
. MIC connection jack - Connect MIC provided.
. Articulation - Adjusting received signal clearly.
. Gain - Adjusting Gain of Receiver.
. Volume - Adjusting volume of speaker.
. Channel - Adjusting channel and frequency
up/down.
(1)
(2)
Distress signal.
(3)
message edited by DSC mode or Stop alarm
sound, Stop distress and call display also.
(4)
messages ON/OFF in DSC mode.
(5) : Selecting main menu.
(6)
with random keys.
: Power ON / OFF in main unit.
: Hold pressing 3sec, Transmitting
: Transmitting frequency/channel &
: Auto acknowledge for the received
: Hold this key and extend functions
: Select ATT in order.
(The part of received diminution can select 3 levels)
: ON/OFF Scan function.
(Scan function of channel or frequency can be started and finished)
: ON/OFF Speaker.
: Select printer function.
(Can be printed to channel and message that received frequency)
: ON/OFF N.B.
[Ref.] when it is receiving H3E, Noise
Blanker removes noise out of it. (Noise Blanker: It works to block high level of impulse of short duration as a device to cut off one stage from middle frequency of receiver.)
: Selecting "CH" "TX" "RX" in
Order.
Channel and TX/RX Frequency)
(Display LCD left-bottom)
: ON/OFF internal test tone
Signal at 1.4 KHz.
(Display LCD on top)
(Display LCD on top)
(Display LCD left-bottom)
(Be available to select
14
: ON/OFF AGC.
(Display LCD left-bottom) Adjust automatically gain that bundle of amplification of receiver. (Auto Gain Control: It means that system maintain to regardless of changing of strength that input signal by the book of receiver’s power. As is higher signaling that incoming to system, diminution degree of gain is increasing, in conclusion low signal much more amplifier than high signal).
: ON/OFF SQL.
(Display LCD left-bottom) Delete to noise that occurred on standby receiving according to signal level. (*Squelch: mute the equipment and delete to harassing background noise and unwanted signal automatic control to the function of receiver or amplifier exception of incoming signal exceed to a set point)
: By check mode, RX set displays RX signal(RxG), Voltage(24V)(VOLT), TX set displays PA currency(Ic), Antenna currency(ANT), standing wave ratio(SWR).
: Adjust dimmer 5steps in
front panel.
: Switch AM receiving mode.
: Operating matching channel
before input frequency.
[[[[▲▲▲]or[
take turns HIGH / LOW / MID.
(7) : this button is for selecting to item of
selection on menu mode and for cursor moving on the display.
(8) ~
(9) : Adjust LCD back light (internal) by
4steps. (Holding [FUNC] and press [DIM], Adjust by 5steps.)
(10)
(10)
(10) (10)
(Holing [FUNC] and press [MODE], Switch AM mode.)
[Ref.] ☞ SSB (J3E):
(11)
push this button. (Press [FUNC] and hold with [ATU] for 2sec, Matching all channel.)
(12) : Cancel set or return precious menu.
(13) : Execute selecting, input, and
extend...etc at the menu.
]or[▼▼▼]]]] :
]or[]or[
: be useful to input the number.
: Switch SSB & DSC mode.
DSC (F1B): use to digital selective
: Matching with user's antenna then
: Change of TX Frequency
: :
use to voice communication
calling communication
(14) LED Display
[DISTS]: When receive a Distress signal by W/K
receiver or transmit a Distress alarm signal, be flickered LED indicator.
[OTHER]: when receive DSC without DISTRESS
signal, be flickered Green LED Indicator.
[TX] : LED on, transmitting [W/K]: LED display …… LED on W/K receiver is
operating. (Always Working)
4.2. LCD display
The following information is displayed in general.
(1) Communication Mode (SSB, DSC, AM (only RX)),
Speaker, Acknowledge, Scan, TX power, Time (UTC GPS being connected)
(2) W/K receiving channel, TX/RX frequency &
channel.
(3) Attenuator (ATT), Noise Blanker (N.B), AGC,
Squelch.
(4) RX signal level, Voltage/Currency (I-c) / (ANT-
c)/ Standing-wave ratio (Select [F] + [0]), Date, time (Display UTC, if GPS receiver connected)
(5) Location mark
“MAN”: Manual Input “GPS”: GPS location (GPS connected) MMSI (Maritime Mobile Service Identity) ID
(6) Display according to the key input.
(7) Display Description
A)
b)
c) ACK : Display if it selected an automatic
d) SCN : Press to start
acknowledge in DSC mode.
"SCAN" and press SCAN is finished.
: Display communication mode
in use.
: , ON/OFF Speaker
ON - Display
OFF- Display
, and then
15
e) HIGH : Display transmitting power.
HIGH : SRG-3150DN (J3E:150W, FIB:
100W)
MID : SRG-3150DN (J3E:100W,
F1B:100W)
LOW : SRG-3150DN (J3E:50W, F1B:75W)
f) F: Display is in use or not. g) AC : Indicate currency situation to POWER
SUPPLIER (SP-1250ADC).
AC : AC Power Supply. DC : battery power supply.
4.3. LCD display flow
S S B
MAIN DISPLAY
D S C
AM (H3E)
H) : Display scanning W/K frequencies
(6 channels).
i) TX : Transmitting Frequency j) RX : Receiving Frequency
k) ATT3 : Level of attenuation.
ATT1: 10dB, ATT2: 20dB, ATT3: 30dB
l) NB : Display Noise Blanker set. m) AGC : Display Auto Gain Control. n) SQL : Display Squelch set. o) CH : Display channel.
p) : indicate a
received gain and use to button and can select to
indictable to SWR(standing wave ratio) / VOLT(PS current) / IC(TX current) / ANT(Antenna currency), indicate to date and time and automatic indicate to UTC when connected GPS, GPS receiver
q) : Indicate GPS
received date (latitude, longitude) when input hand – operated coordinate, receive directly date from GPS receiver and indicate screen to “GPS”, indicate tuning situation in changing channel with MMSI ID.
SSB
MAIN MENU 1. Scan Type Set
2. Scan Channel Set
3. Scan Frequency Set
4. SQL Set
5. LCD Contrast Set
6. TX POWER Set
7. Manual Tuning
8. ATU - VERSION
9. Remote Set
0. SYSTEM Set
DSC
MAIN MENU 1. Distress msg edit
2. Individual msg edit
3. Group msg edit
4. Geography msg edit
5. Auto/Semi-AT msg edit
6. Dist. ack/rly msg edit
7. Ordinary ack msg edit
8. Display & Print msg
9. System Set
AM
*** Only Receive Function
16
:
:
Chapter 5. SSB (TEL) mode
5.1. SSB Mode
Press button on front panel, and then go to SSB mode.
5.2. SSB Menu
On SSB Mode when press display to Menu screen
as follow. .
[][] Move, and select to wanted function,
Selected.
[Number button] Input the value.
Set up.
Press to back to main screen.
[Ref.] [Start] : Set Start channel.
(3) Scan Frequency Set
a) Set value in case of scanning Frequency.
3. Scan Freq. Set is selected.
The below box shows.
Start End Speed Step
[End] : Set Last channel. [Speed] : Set speed of scan channel
(0~9, 0: Fastest, 9: Slowest)
:
500.00 kHz
:
29,999,99kHz
:
0
:
0.1 kHz
(1) Scan Type Set
a) Decision scanning channel or frequency.
1. Scan Type is selected.
Select, switching [CH]/ [Freq] in rotation
Return to Main Display.
B)
[Ref.] Scan type is [CH], scan channel.
(2) Scan Channel Set
a) Fix setting value in case of scanning channel.
, scan to select SACN Type.
Scan type is [Freq], scan frequency.
2. Scan Ch. Set is selected.
The below box shows.
Start End Speed
: : :
1 299 0
[][] Move, and select to wanted function,
Selected.
[Number Button] Input the value.
Set up.
Press to back to main screen.
[Ref.] [Start] : Set Start Frequency.
(4) SQL Set
a) On standby, if set setting value of SSB particular sound clearance highly, cannot receive slight signal.
4. SQL Set is selected.
The below box shows.
SQL Sense SQL Delay
[][] Move, and select to wanted function,
Selected.
[Number button] Input the value.
Set up.
Press to back to main screen.
[Ref.] [SQL Sense]: Set sensibility of SQL.
[SQL Delay]: Set delay time of SQL circuit.
[End] : Set Last Frequency. [Speed]: Set speed of scan Frequency. [Step] : Set step of scan Frequency.
(100HZ/step)
“10.0at 10kHz step.
10 5
Set range : 1 ~ 20 Set range : 1 ~ 20
17
(5) LCD Contrast Set
5. LCD Contrast is selected.
Press to change the LCD brightness
From [1] ~ [5] step.
(Higher value and more thicker)
(6) Tx Power Set
a) Adjust TX power.
6.Tx Power is selected.
Select HIGH / MID / LOW
b) If Tx Power
HIGH, Display "HIGH",
SRG-3150DN(J3E:150W, FIB:100W)
MID, display "MID",
SRG-3150DN(J3E:100W, F1B:100W)
LOW, display "LOW".
SRG-3150DN(J3E:50W, F1B:75W)
(7) Manual Tuning
a) ATU tuning by manual.
7.Manual Tuning is selected.
The below box shows.
TX Power : Tune
(9) Remote Set
a) Set remote operating.
9. Remote OFF is selected.
Press, can be changed 9.Remote ON, Display "REM" on the main screen.
b) Press and then change to remote off.
(10) System Set
a) Select system’s value.
0. System Set is selected.
The below box shows.
[1.Tuning Clear]: Clear all the memory tuned.
1. Tuning Clear is selected.
The below box shows.
[] Move to Yes
0.0 uH
0 pF
0 pF
OFF
OFF
OFF
[][] Select the point which it is to be
adjusted by[][]
[][] Adjust it’s value by [][]
Selected.
[Ref.] press , the value adjusted is input
and return main menu.
On manual tuning, TX power has not changed
while switching frequency.
(8) ATU – Version (ATU Program Version)
8. ATU---Version is selected.
Selected.
[Ref.] if ATU DATA cable has any trouble,
Display "Error.”
Reboot system.
[2.SSB-CH Clear]: Delete channel data and set channel.
2. SSB-CH Clear is selected.
The below box shows.
[] Move to Yes
Reboot system.
[3.Data-Set]: Set data in system. In external GPS Data input, UTC (Universal Time
Coordinated) is displayed.
[4.Time-Set]: Set time in system. In external GPS Data input, UTC (Universal Time
Coordinated) is displayed.
[5.Key Tone]
5. Key Tone is selected.
Press, can be changed On/Off.
18
Tuning
:
[6.ADC Value]: RXG in first display – Show selecting ON/OFF.
6. ADC Value is selected.
Press, and then can select IC, ANT, SWR, VOLT.
[Ref.] RxG : Rx Signal Level
(On setting IC, ANT, SWR, displayed on receiving)
IC : End Current, ANT : Antenna Current SWR : Standing Wave Ratio VOLT : it means electricity, voltage and
In case of setting IC, ANT and SWR, display reference to transmitting.
[7.Auto Tune] : Matching all channels
automatically.
7. Auto Tune is selected.
The below box shows.
Freq Tune
[8.Self Test]: Self test function.
:
2,032.0kHz
:
- - -
5.3. Additional Functions
(ITU
Channel, AM mode, Etc.,)
(1) ITU Channel [CH401 - CH2510], it can be
selected by [CH] and [Number] on SSB Mode, if it is within reference to range channel, it can be switching channel by dial or button[up/down] of Hand-MIC.
(2) Press , it switches [AM]
(H3E) mode, use , it switches another mode [SSB or DSC].
[Ref.] there’s no TX display at the [AM] (only
RX), AGC is set automatically.
8. Self Test is selected.
The below box shows.
Version Receiver Watch-R Exciter Tuner
[9.Key Test]: Test button the front screen.
9. Key Test is selected.
When press selected button and then
display title that selected button on the screen.
: :
: :
2.0 good good good good
(3) DSC Channel (CH300 ~ CH399), DSC message appears, goes to mode and edit and change DSC channel by front knob, hand MIC up/down
[Ref.] DSC mode / MENU > 2.Individual Msg
Edit / can be edited in DSC Message by [] [].
(4) It can be moved by cursor on menu mode by [CH] dial.
(5) If you want to stop on receiving [DISTS] &
[OTHER] press .
19
Chapter 6.
6.1.
Set DSC Mode by on the front Panel as follow.
a) use in a normal condition. b) CH7CH19: Normal can be used by users and pressing [SCAN] key, it can scan only in specified
data location within CH7~CH19 channel.
The selection of DSC mode
CH1~CH6: In case of emergency only. Not possible to
Digital selective calling (DSC) mode
6.2. DSC menu display
Press on the initial screen of the DSC mode, the sub menu screen is set as follow.
Press, display can edit msg. on the
screen. (Or can be edited what you want.)
[FORMAT]: A kind of calling.
Distress :
[NATURE]: The type of distress.
[][] Move to NATURE
[][] Go to the menu you want.
Distress calling(fixed)
The below box shows.
Fire, Explosion Flooding Collision Grounding Listing Sinking Adrift Undesignated Abandon ship Piracy/Attack Man Overboard
(1) Distress msg edit a) In case of calling distress.
1.Distress msg edit is selected.
The below box shows.
CH = 300 CH = 301 CH = 302
…… CH = 399
[Ref.] [] [] : Moving up and down with
[][] : Moving up and down with
[][][][] Select Channel that format is
Distress
: : :
:
1 step channel.
10 step channels.
(NO DATA) (NO DATA) (NO DATA)
…… (NO DATA)
Selected.
[POSITION]: Position of distress.
(Auto-set in a connection with GPS)
[][] Move to POSITION
The below box shows.
N _ _ , _ _ , _ _ _ _ / E _ _ _ , _ _ , _ _ _ _
North latitude(00.00.0000~90.00.0000) east longitude(000.00.0000~180.00.0000)
S _ _ , _ _ , _ _ _ _ / W _ _ _ , _ _ , _ _ _ _
South latitude(00.00.0000~90.00.0000) west longitude(000.00.0000~180.00.0000)
[Number button] Input the value.
Set up.
[Ref.] Press [] [] to change [N_-- E --_]
/ [S -- W_--] / [S – E --] / [N -- W_--] in turns
If the value is beyond the value range, the set up can not be done.
20
[DIST-UTC]: Set time of distress.
[TX-Freq]: Set TX frequency.
[][] Move to DIST-UTC
The below box shows.
- - : - - - : Time of Distress(00:00 - 23:59)
[Number. button] Input the time.
Selected.
[Ref.] Set automatically in connection with
GPS.
[TEL CMD]: Set Telecomm and.
[][] Move to TEL-CMD
Press [J3E TP] / [FIB/J2B T].
[EOS]: Completion of DSC message.
(EOS=End of Sequence)
EOS –
Set automatically. (fixed)
shown [……File Saved……] and
be saved...
b) After setting items press and then transmit DISTRESS signal as Frequency that before edition on DSC main screen.
(2) Individual msg edit.
a) Used in an individual call or coast station call.
2. Individual mag edit is selected.
The below box shows.
CH = 300 CH = 301 CH = 302
…… CH = 399
[Ref.] [] [] : Moving up and down with
[][] : Moving up and down with
[][][][] The channel is selected.
The below box shows.
to change
(NO DATA)
:
(NO DATA)
:
(NO DATA)
:
……
:
(NO DATA)
1 step channel.
10 step channels.
[][] Move to TX-Freq
The below box shows.
01 02 03 04 05 06 19
[Ref.] MENU>9.SYSTEM SET>0.Etc.
Set>3.Default Channel possible to select
default TX frequency.
[][] The frequency is selected.
Selected.
[Ref.] Indicate the frequencies which is
memorized by user in DSC mode CH7~19.
[FORMAT]: A kind of calling.
Individual :
[CATEGORY]: Purpose of calling.
[][] Move to CATEGORY
[][] Go to the menu you want.
Selected.
[PARTY ID]: Input the ID of counter party.
[][] Move to PARTY_ID
[Number. button] Input ID.
Set up.
[TEL CMD1]: Set Telecommand1.
[][] Move to TEL CMD1
an individual calling(fixed)
The below box shows.
Routine Safety Urgency :
Selected.
The below box shows.
: : : : : :
2,187.50 4,207.50 6,312.00 8,414.50 12,577.00 16,804.50 8,414.50
[][] Go to the menu you want.
Selected.
[TEL CMD2]: Fix
No information
21
[WORK FRQ]:
[][] Move to WORK FRQ
Selected.
[Number. button] Input TX frequency.
Set up.
[Number. button] Input RX frequency.
Set up.
[EOS]: Completion of DSC message.
(EOS=End of Sequence)
ACK RQ :
[Ref.] ACK RQ: Function to request other’s
response. (ACK=Acknowledge=Auto response)
b) Function Keys
After inputting data press and it is saved.
select [PARTY-ID]press and registered
Auto-set.(Fixed)
Operational frequency.
c) After setting items, press “individual call” signal transmits.
d) When ACK response signal is received, communication can be possible with the voice communication frequency.
(3) Group msg edit
a) Call specified ships as such a same group or company simultaneously.
3. Group msg edit is selected.
The below box shows.
CH = 300 CH = 301 CH = 302
……
[][][][] The channel is selected.
The below box shows.
CH = 399
: : :
:
(NO DATA) (NO DATA) (NO DATA)
…… (NO DATA)
and
ID list shows select by [][]
[Ref.] How to register ID: MENU>9.SYSTEM SET>5.ID/FR/TEL Set>1.ID Edit and register.
Select[WORK FRQ]press and registered
frequency list shows select by [][]
[Ref.] How to register frequency that communicate with voice: MENU>9.SYSTEM
SET>5.ID/FR/TEL Set>3.Work Frequency Edit and register.
select [WORK FRQ] press [WORK FRQ] / [POSITION].
Select [POSITION] by
Input by [No. button]
to change
[TX-Freq]: Set TX frequency.
[][] Move to TX-Freq
The below box shows.
01
:
2,187.50
02
:
4,207.50
03
:
6,312.00
04
:
8,414.50
05
:
12,577.00
06
:
16,804.50
19
:
8,414.50
[][] The frequency is selected.
Selected.
[Ref.] Indicate the frequencies which is
memorized by user in DSC mode CH7~19.
[FORMAT]: A kind of calling.
Group :
[CATEGORY]: Purpose of calling.
Routine :
Group calling(fixed)
use general (fixed)
22
[PARTY ID] : Input the ID of counter party.
[][] Move to PARTY_ID
Selected.
[Number. button] Input ID.
Set up.
[TEL CMD1]: Set Telecommand1.
[][] Move to TEL CMD1
Press
to change
[J3E TP] / [FIB/J2B TTY-FFC].
[TEL CMD2]: Fix
[WORK FRQ]:
No information
Operational frequency.
[][] Move to WORK FRQ
Selected.
[Number. button] Input TX frequency.
Set up.
[Number. button] Input RX frequency.
Set up.
[EOS]: Completion of DSC message.
(EOS=End of Sequence)
EOS:
Auto - set. (fixed)
b) Function Keys
After inputting data press and it is saved.
select [PARTY-ID]press and registered
ID list shows select by [][]
[Ref.] How to register frequency that communicate with voice: MENU>9.SYSTEM
SET>5.ID/FR/TEL Set>3.Work Frequency Edit and register.
c) After setting items, press call” signal transmits.
d) When ACK response signal is received, communication can be possible with the voice communication frequency.
(4) Geography msg edit
a) calling all ships by coast station call. Use for communicating with all ships about safety and others by coast station call. When coast station call, will be waited automatically all ships as set voice communication frequency.
b) calling all ships by base of ships.
It’s no use generally. Use for emergency or sending important
information.
4.Geography msg edit is selected.
The below box shows.
CH = 300 CH = 301 CH = 302
…… CH = 399
: : :
:
(NO DATA) (NO DATA) (NO DATA)
…… (NO DATA)
[][][][] The channel is selected.
The below box shows.
and “group
[Ref.] How to register ID: MENU>9.SYSTEM SET>5.ID/FR/TEL Set>1.ID Edit and register.
Select[WORK FRQ]press and registered
frequency list shows select by [][]
[TX-Freq]: Set TX frequency.
[][] Move to TX-Freq
The below box shows.
01 02 03 04 05 06 19
2,187.50
:
4,207.50
:
6,312.00
:
8,414.50
:
12,577.00
:
16,804.50
:
8,414.50
[][] The frequency is selected.
Selected.
23
[Ref.] Indicate the frequencies which is
memorized by user in DSC mode CH7~19.
[FORMAT]: A kind of calling.
Geography :
[CATEGORY]: Purpose of calling.
[][] Move to CATEGORY
local calling(fixed)
c) Function Keys
After inputting data press and it is saved.
select [PARTY-ID]press and registered
ID list shows select by [][]
Press [Safety] / [Urgency].
[PARTY AD]: reference to 24page
[TEL CMD1]: Set Telecommand1.
[][] Move to TEL CMD1
Press [J3E TP] / [FIB/J2B TTY-FFC].
[TEL CMD2]: Set Telecommand2. In case of setting [Safety],
fixNo informationin [CATEGORY].
In case of setting [Urgency] in [CATEGORY].
( MENU>9.SYSTEM SET>0.Etc. Set>
9.Medi-Trans. Set and select on) [][] Move to TEL CMD2
The below box shows.
[][] Go to the menu you want.
Selected.
[WORK FRQ]:
[][] Move to WORK FRQ
Selected.
[Number. button] input TX frequency.
Set up.
[Number. button] input RX frequency.
Set up.
[EOS]: Completion of DSC message.
EOS :
Auto - set.(fixed)
to change
to change
Operational frequency.
.
[Ref.] How to register ID: MENU>9.SYSTEM
SET>5.ID/FR/TEL Set>1.ID Edit and register.
Select[WORK FRQ]press and registered
frequency list shows select by [][]
[Ref.] How to register frequency that communicate with voice: MENU>9.SYSTEM
SET>5.ID/FR/TEL Set>3.Work Frequency Edit and register.
c) After setting items, press “Geography call” signal transmits.
d) When ACK response signal is received, communication can be possible with the voice communication frequency.
and
24
N _ _
: North latitude
(00 -
90) (φ
[PARTY AD]: Input location data
[][] Move to PARTY_AD
Selected.
S _ _ : South latitude (00 - 90) (φ ) E _ _ : East longitude (000 - 180) (λ ) W _ _ _ : West longitude (000 - 180) (λ )
DA _ _ : Latitude range (Offset Value) (
)
φ)
[Ref.] ☞ φ = Latitude
λ = Longitude
Δ
φ = Latitude Range
Δ
λ = Longitude Range
Do _ _ : Longitude range(Offset Value) (
[Number. button] Input the value.
Set up.
[Ref.] every press [] []
N_ _ E_ _ / S_ _ W_ _ / S_ _ E_ _ / N_ _ W_ _be switched in turns.
λ)
25
(5) Auto/Semi-AT msg edit
a) Use for communicating connected with telephone.
5.Auto/Semi-AT mag edit is selected.
The below box shows.
CH = 300 CH = 301 CH = 302
: : :
…… CH = 399
:
(NO DATA) (NO DATA) (NO DATA)
…… (NO DATA)
[][][][] The channel is selected.
The below box shows.
[TX-Freq]: Set TX frequency.
[][] Move to TX-Freq
The below box shows.
01
:
2,187.50
02
:
4,207.50
03
:
6,312.00
04
:
8,414.50
05
:
12,577.00
06
:
16,804.50
19
:
8,414.50
[][] The frequency is selected.
Selected.
[Ref.] Indicate the frequencies which is
memorized by user in DSC mode CH7~19.
[FORMAT]: A kind of calling.
AT/semi-AT :
AT/semi-AT Calling(fixed)
[CATEGORY]: Purpose of calling.
Routine :
use generally (fixed)
[PARTY ID]: Input ID.
[TEL CMD1]: Set Telecommand1.
[][] Move to TEL CMD1
The below box shows.
[][] Go to the menu you want.
Selected.
[TEL CMD2]: fix
No information”.
[WORK FRQ]:
Operational frequency.
[][] Move to WORK FRQ
Selected.
[Number. button] input TX frequency.
Set up.
[Number. button] input RX frequency.
Set up.
[TEL NO.]: Input telephone number.
[][] Move to TEL NO.
Selected.
[Number. button] Input telephone number.
Set up.
[EOS]: Completion of DSC message.
ACK RQ :
Auto-set.(fixed)
b) Function keys
After inputting data press and it is saved.
select [PARTY-ID]press and registered
ID list shows select by [][]
[][] Move to PARTY_ID
Press.
[Number. button] Input ID.
Set up.
[Ref.] How to register ID: MENU>9.SYSTEM
SET>5.ID/FR/TEL Set>1.ID Edit and register.
26
Select[WORK FRQ]press and registered
frequency list shows select by [][]
[Ref.] How to register frequency that communicate with voice: MENU>9.SYSTEM
SET>5.ID/FR/TEL Set>3.Work Frequency Edit and register.
select [WORK FRQ] press
to change
[WORK FRQ] / [POSITION].
Select [POSITION] by
Input by [No. button]
Select [TEL NO.]press and shown registered Telephone No. List
select by [][]
[Ref.] How to register Telephone No: MENU>
9.SYSTEM SET>5.ID/FR/TEL Set>
3.Telephone No. Edit and register)
c) After setting items, press
and signal
transmits.
d) Coast station call by telephone with calling data, connect the signal and send ACK signal to ship and then will be communicated as switching fixed voice communication frequency.
(6) Dist ack/rly msg edit
a) After inputting the info. , use this menu to respond to distress signal and manual relay of the distress message.
6.Dist ack/rly msg edit is selected.
The below box shows.
b) It is memory channel using from 400 to 499 as right on the top.
[Ref.] [] [] : Moving up and down with
1 step channel.
[][] : Moving up and down with
10 step channels.
c) When received recently distress signal from other ship, can check the message.
Press , input ID press and then transmit to Distress signal.
d) Press , shown new relay message on screen and will be editable.
When can not send distress signal, edit and press
and then can be transmitted.
[TX-Freq]: Set TX frequency.
[][] Move to TX-Freq
The below box shows.
01
:
2,187.50
02
:
4,207.50
03
:
6,312.00
04
:
8,414.50
05
:
12,577.00
06
:
16,804.50
19
:
8,414.50
[][] The frequency is selected.
Selected.
[Ref.] Indicate the frequencies which is
memorized by user in DSC mode CH7~19.
[FORMAT]: A kind of calling.
[][] Move to FORMAT
Press
to change
[Geography] / [Individual].
[CATEGORY]: Purpose of calling.
Distress :
Distress calling(fixed)
27
[PARTY ID] : Input the ID of counter party.
In case of selecting [Individual] in [FORMAT], input ID
[][] Move to PARTY_ID
Selected.
[Number. button] Input ID.
Set up.
Select [FORMAT] In case of [Geography], shown [PARTY-AD], input specific area.
[][] Move to PARTY_AD
Selected.
[Number. button] Input ID.
Set up.
[Ref.] MENU>4.Geography msg edit/
PARTY AD and register.
[TEL CMD]: fix
Distress Relay
[Ref.] Distress Relay: in case of relaying
broadcast cause the distance is far from coast station.
[DIST ID]: Input the ID of the vessel in distress. [][] Move to DIST ID
Selected.
[Number. button] Input ID.
Set up.
[NATURE]: The type of distress.
[][] Move to NATURE
The below box shows.
Fire, Explosion Flooding Collision Grounding Listing Sinking Adrift Undesignated Abandon ship Piracy/Attack Man Overboard
[][] Go to the menu you want.
[POSITION]: Input the Position of the vessel in distress. [][] Move to POSITION
The below box shows.
N _ _ , _ _ , _ _ _ _ / E _ _ _ , _ _ , _ _ _ _
North latitude(00.00.0000~90.00.0000) east longitude(000.00.0000~180.00.0000)
S _ _ , _ _ , _ _ _ _ / W _ _ _ , _ _ , _ _ _ _
South latitude(00.00.0000~90.00.0000) west longitude(000.00.0000~180.00.0000)
[Number button] Input the value.
Set up.
[Ref.] Press [] [] to change [N_-- E --_]
/ [S -- W_--] / [S – E --] / [N -- W_--] in turns
If the value is beyond the value range, the set up can not be done.
[DIST-UTC]: Input the time of distress.
[][] Move to DIST-UTC
The below box shows.
- - : - - - : Time of Distress(00:00 - 23:59)
[Number. button] Input the time.
Selected.
[Ref.] Set automatically in connection with
GPS.
[TEL CMD]: Set Telecommand.
[][] Move to TEL CMD
Press
to change
[J3E TP] / [FIB/J2B TTY-FFC].
[EOS]: Completion of DSC message.
(EOS= End of Sequence)
ACK RQ:
Auto - set. (fixed)
e) After setting items, press
and signal
transmits.
f) When other ship or coast station send ACK answer, ship that transmitted distress be going to receive.
Selected.
28
(7) Ordinary ack msg edit a) In case of common answer call.
7. Ordinary ack msg edit is selected.
The below box shows.
(9) System Set
a) in case of setting the value of SYSTEM.
9. System Set is selected.
The below box shows.
b) Memory channel is from 500 to 599 and it shows on the right top of the box. You can see the general info. Except distress signal.
[Ref.] [] []: Moving up and down with
1 step channel.
[][]: Moving up and down with
10 step channels.
c) In this menu press and can be answered.
(8) Display and print msg
a) In checking the written messages or auto printing.
8. Display and print msg is selected.
The below box shows.
b) Channels are 300 to 399, can be confirmed on screen.
[Ref.] [] []: Moving up and down with
1 step channel.
c) If this mode is selected with the printer connected, printing of the message starts automatically.
[1.Self ID Set]: Input own ship ID.
1. Self ID Set is selected.
Selected.
[Number. button] Input ID.
Set up.
[2.Group-ID Set]: Input Group ID.
2. Group ID Set is selected.
Selected.
[Number. button] Input ID.
Set up.
[Ref.] ☞ it’s possible to input just 1 time because ID is proper number of the ship, so if
you want to make modification, you can reach in menu by password. Distributor has a password.
[Ref.]
 How to change ID.
Press
to go to [SSB] mode
[ ] [ ] [ ] [ ] (Password-Contact
dealers)
(Set as ‘ENABLE’)
(Return to main
screen)
 [Self-ID Set]
Press to go to [DSC] mode
Input by [No. button]
 [Group-ID Set]
Press to go to [DSC] mode
Input by [No. button]
29
[3.Dist TEL-CMD]: Set Telecommand.
3. Dist TEL-CMD is selected.
Press
to change
[J3E TP] / [FIB/J2B T].
[4.LAT / LON Set]: Set Lat/Lon of GPS by hand-operation.
4. LAT/LON Set is selected.
The below box shows.
Ex) How to input ID and ship’s name: SAMYUNG, 101010000
[]
[]
[]
[]
[]
[]
It is input as below
[Number button] Input the value.
Set up.
[5.ID/FR/TEL Set]: Edit ID/Auto answering ID/Operating frequency/Telephone number.
[1.ID] edit
5. ID/FR/TEL Set is selected.
Selected.
1. ID is selected.
The below box shows.
The below box shows.
[Number button],][] Select Character, move, Select Character, move
The below box shows.
0 0 0 0 0 0 0 0 0
[Number. button] Input ID.
Set up.
If want to return menu.
[Ref.] ☞ Blank is filling with 0.
[2. Auto-ack ID] edit
5. ID/FR/TEL Set is selected.
Selected.
2. Auto-ack ID is selected.
Selected.
,
[Number. button] Input ID.
Set up.
 [3. Work Frequency] edit
5. ID/FR/TEL Set is selected.
Selected.
3. Work Frequency is selected.
Selected.
,
[Number. button] Input TX frequency.
Set up.
[Number. button] Input RX frequency.
Set up.
 [4. Telephone No.] Edit
5. ID/FR/TEL Set is selected.
Selected.
4. Telephone No. is selected.
Selected.
,
[Number. button] Input telephone number.
Set up.
30
[6.WKR Scan Set]
[0.Etc. Set]: Set etcetera system.
6. WKR Scan Set is selected.
The below box shows.
2187.5 on
4207.5 on
6312.0 off
8414.5 on
12577.5 off
16804.5 off
[][] The frequency is selected.
Press
to change [on] / [off].
[Ref.] ☞ [2187.5] and [8414.5] must be on.
[7.Data Clear]: Able to delete the user data and received data.
7. Data Clear is selected.
The below box shows.
1.DSC Made-File clear
2.DSC Distress clear
3.DSC Ordinary clear
4.DSC Channel clear
5.DSC All Data clear
User DSC data
Distress data among received
DSC data
Data except Distress data among
Received data
Delete all data of DSC Channel
Clear all data of DSC to
make an initial
[][] Go to the menu you want.
The below box shows.
[] Move to Yes
The data will be deleted
[8.ID printing]: Print ID.
[9.Data Transmit]: Able to select type of
transmitting data and can be used in data transmitting.
9. Data Transmit is selected.
The below box shows.
1.Dot Transmit
2.Mark transmit
3.Space Transmit
Send Dot signal only
Send Mark signal only
Send space signal only
0. Etc. Set is selected.
The below box shows.
[1. GPS Alarm]
1. GPS Alarm is selected.
Press
to change [on] / [off].
[Ref.] ☞ Regardless of on don’t received GPS
signal, display error on screen and sound alarm continually.
[2. Scan Speed]: Adjust SCAN speed of usable DSC channel by user. The higher number it is, the slower speed (7~19Ch).
2. Scan Speed is selected.
Selected.
[Number. button] Input the value.
Set up.
[3. Default Channel]: [SIN] = If set Single MENU>2.Individual msg edit / 3.Group msg edit / 4.Use Geography msg edit.
3. Default Channel is selected.
Selected.
2,187.5
4,207.5 6,312.0 8,414.5
12,577.0 16,804.5
[][] The frequency is selected.
Selected.
[4. Auto ACK]: Auto answer on distress calling.
4. Auto ACK is selected.
Press
to change [on] / [off].
[Ref.] ☞ showed ACK” on screen, in case of
setting on.
[Ref.] ☞ select on of them by [] []
press and then it is transmitted immediately so must be careful.
31
[5. DSC Msg Receive]: Receive DSC message.
5. DSC Msg Receive is selected.
Press
to change [on] / [off].
[Ref.] ☞ message receiving is not available.
[6. DSC Trans. Mode]: Set DISTRESS TX channels SIN (single) or MUL (multi).
6. DSC Trans Mode is selected.
Press
to change [MUL] / [SIN].
[Ref.] ☞ Select [MUL], transmit 6channels in turns and select [SIN] the first channel (2,187.50
KHz) just transmit 5 times repetitively.
[7. DSC Geo. Range]: Set area range Geography message transmitting.
7. DSC Geo Range is selected.
Press
to change [120] / [240]. /
[360] / [500] / [600]. (단위는 NM)
[Ref.] MENU>4.Geography msg edit on
screen. In case of setting [PARTY-AD] area range, just input latitude and longitude and press
[8. Dist-Key Test]: [DISTRESS] button Test.
8. Dist-Key Test is selected.
The below box shows.
Press Distress Key
Press
[DISTRESS] for 3 seconds and the
below box shows.
Press Stop Key
Back to Main screen.
[9. Medi-Trans. Set]: Set Medical Transport [on] / [off].
9. Medi Trans Set is selected.
Press
to change [on] / [off].
[Ref.] in case of setting on MENU>4.Geography msg edit>TEL CMD2
and then can be set.
and then setting value shown that are inputted of changing value of latitude range and longitude.
32
Chapter 7. Transmitter of distress signal
7.1. Test of Distress alert signal
(1) Hold on 3 seconds [DISTRESS] in the panel, flicker DISTS] LED with alarm and after 3 seconds shown following screen, [DISTS] LED is lighted and transmit distress location, distress time, ID.
(2) If don’t have a answer, flicker[DISTS] LED and shown following screen and then after 4 minutes(3min 30sec ~4min 40sec), transmit channel 1 ~ 6.
[Ref.]
(3) If you want to stop to transmit, press .
Even you press ; channel that is transmitting will be stop after finishing the transmitting.
[Ref.] MENU>9.System Set>1.Self ID Set If it didn’t set and then flicker [MMSI not
entered] on main screen and can’t transmit.
begin in countdown “
Left 04:00.
•Transmit channel 1 ~ 6 as follow. 01 02 03 04 05 06
: : : : : :
2,187.5 4,207.5 6,312.0 8,414.5 12,577.0 16,804.5
33
Yes
No
No
Yes
Rx ACK
Check the saved messages
Is the
Check the
Chapter 8. RX of Distress & general call
8.1. RX of Distress Alarm
(1) Once Distress alarm is received from Distressed vessel, Red color [DISTS] LED is blinking and
Alarm sounds. To stop the Alarm, press . If the CRS reply to the Distress message, the reply
messages appear. (Normally within 3 min.) If the Distressed vessel receives ACK message from CRS, follow the CRS instruction.
(2) Flow Chart
Distress Alarm RX
Press button to stop the
Check the ID, Distress position on the saved message screen.
within 3
min. from
CRS.
(Alarm sounds)
Press button and stop the alarm.
Keep listening to the distress frequency (Stand-by for the CRS instruction and listen to the distress communication until it finishes.
Red color [DISTS] LED blinks and alarm sounds
Beyond 150 nm from own ship
In case own ship go and
distressed
vessel near
own ship?
On the DSC menu, select Distress relay. After editing, press call button to relay the distress.
rescue the distress vessel, use radio telephone on the distress frequency.
distress
vessel is
near own
ship?
No
After relay the distress signal, wait for the reply from CRS.
34
8.2. General call RX
(1) In case [Auto ACK] is [on], if you receive individual call & group call, automatically, ACK reply transmits and the frequency is set to TX/RX counter party.
(2) Flow Chart
RX Individual Call
In case [Auto ACK] set is [off], press button and transmit , then the frequency is shifted
to voice communication frequency and the voice communication is possible.
In case [Auto ACK] setting is [on], ACK reply is transmitted, Automatically, the frequency is shifted to voice communication frequency and then voice communication is possible.
Communicate with counter party
Communication ends
Green [OTHER] LED blinks and alarm sounds.
35
Chapter 9. How to use print
9.1. DPU-414 Printer
(1) Caution for use a) The printing paper used for the DPU-414 is a special kind of paper which turns black by the thermo chemistry reaction. Take as following precaution when using the paper.
Store away from Hit, Humidity, light. Dry hands before handling with the paper Don't rub the paper with any kind of hard or
coarse materials. Don't use organic adhesive on the paper. (Instead of that, water-based starch adhesives or compound adhesive.) Don't use adhesive tape on the paper. (However, using both sides tape is possible.) Don't allow the paper to remain in contact with polyvinyl chloride film for a long time. Don't leave the paper in contact with freshly coped giazo type or wet process paper. Don't allow the paper to come into contact with organic solvents.
b) Caution for operation
Check there is a paper in it before use. Don't turn off while operation and turn off after
PRINT HEAD is at HOME POSITION. Printer test function is built-in.
(2) Operation Panels a) POWER Switch Switch on the turn this unit on. Printer head do going and returning once, the paper is fed by one column. On condition that main unit of SRG-3150DN is power on. b) FEED Switch Press FEED switch when feed the paper out by force. On pressing this switch once, it will be feed once and on pressing this switch continuously, it will be kept feeding. c) CUTTER Use for cutting the printer paper. d) Exit of paper - It is the part where the paper is ejected through it. e) PAPER COVER Store up the paper inside it.
(3) Usual operation. Check the main unit of SRG-3150DN is turned on. If power on, it is able to print TX/RX DSC MESSAGE and DATA from SRG-3150DN automatically.
(4) How to store the printer paper roll a) Cut the printer paper horizontally. If there is the wrinkle on the paper, it may cause the paper jam.
< PRINTER PAPER HANDLING >
b) Switch off the printer c) Open the PAPER COVER and pull out the CENTER SHAFT. d) Insert the CENTER SHAFT in the center of the PAPER ROLL and put the end of the paper into the way-in of the paper. e) Switch of the PRINTER and press the FEED KEY until the paper is hauled. f) Store up the center shaft and the paper gets out of the way-out. g) Press FEED KEY until the end of paper gets out of the way-out. h) Close the PAPER COVER and put it down to shut.
9.2. OKI Printer
(1) Common Operation a) Check out the power of SRG-3150DN connected with a Printer ON. b) Pull the switch of the POWER up to turn on the power. c) The DATA and DSC MESSAGE transferred from SRG-3150's transmitting and receiving process is automatically activated.
(2) PAPER LOADING a) Place the printer on a slotted printer stand, carefully aligning the slot in the stand with the opening in the base of the printer. b) Place the box of paper under the printer stand. c) Remove the access cover and lift the column indicator bar. d) Open the paper release lever. e) Insert the first sheet of paper through the opening in the bottom of the printer. f) Slide the paper up until it appears in front of the platen. g) Lower the column indicator bar. h) Close the paper release lever. i) Use the platen knob to advance the paper to the first printing line. j) Replace the access cover.
36
Chapter 10. How to use SD-250(Alarm box)
10.1. Distress transmitting
(1) If you press 'Distress key' (Red Button) for 3 sec., it alarms for 3 seconds. After that, the red light is turned on with bip-sound. While Distress Key is blinking, transmitting is started to work and location of disaster, time, ship's ID are sent to DSC 6 CH in order. If there is no answer, it does sending till getting an answer through CH1 to CH 6.
(2) In order to stop the transmitting, press the 'Reset key'. If distress signal is sent by mistakes, contact to marine police or station, SAR.
10.2.
(1) Distress LED blinks and sounds 'bip'. Check contents displayed on the screen and press Reset key to stop.
In case of receiving distress signal
10.3. Operation by DC (Battery)
(1) If AC power is turned off, POWER LED is blinking with "Bip-" sound and presses the Reset key to stop the sound.
(2) POWER LED keeps blinking while the equipment is operated by DC power.
Chapter 11. How to use SP-1250ADC
11.1. Specification
(1) Input : AC110V / AC220V Conversion Type
(Basis AC220V) (2) Output : DC24V 50A AVR (3) Charging current: 20A (Max)
11.2. Input power shift
In case of AC Power stopping, the buzzer is ringing and LED green light of AC OFF is on. In order to stop the buzzer's ringing, you can turn to OFF in the switch of ALARM.
11.3. How to Charge
(1) In case of transmitting SSB, it doesn't be charged.
(2) There is AUTO / OFF / NORMAL in a switch of the Charger.
(3) AUTO = in a long-time charging and it turns to auto-off when it is completed.
In charging, the LED of CH turns on a light.
In less 23 voltages, auto-charged and finished for
charging in less 0.5 A.
(4) OFF = Not charging. (Middle of Switch)
(5) NORMAL = Sometimes charge it in the mode.
(6) In case of checking the charged current, the switch of CURRENT is turned to CHARGER. In case of transmitting SSB, the switch is turned to TX in order to check the current. REFERENCE: SP-1250ADC is designed to connect with SSB SRG-3150D only and it is charged as own­battery power according to the regulation of IMO (GMDSS). If it is connected with other SSB equipment, you should intercept the charging-circuit in SP-1250ADC and use the high-capacity charging.
11.4. In case of over current
In case of being over than 45A current, the LED red light of OVER CURRENT is on and the buzzer is ringing. On this occasion, intercept the Power Switch AC / DC for over than 1 minute and turn the Power on after deleting the occasion.
37
Chapter 12. Circuit explain
12.1. Overview of SRG-3150DN
SRG-3150DN MF/HF DSC RADIO equipment consists of circuit, PRINTER, ATU (SAT-100).
SRG-3150DN SYSTEM
Control circuit MF/HF Transmitting
filter Circuit
W/K Receiving Circuit Power Amplifier Circuit Front Panel
< SRG-3150DN MF/HF BLOCK DIAGRAM >
SRG-3150DN consists of Power Amplifier circuit, Control circuit, MF/HF Transmitting f ilter circuit, Front Interface, W/K Receiving Circuit. At the rear side of this equipment, there are connectors connected with ATU BOX (SAT-100), SP­1250, ALARM BOAX (SD-250) and connectors of PL­259 type connected with aerial coaxial cable for MF/HF transceiver / receiver and for W/K receiver, a
W/K
NBDP
SN-100
ATU
SAT-100
PRINTER
RX ANT TX/RX ANT
terminal for GPS DATA receiving, external BK Connecting, Printer power supply and besides, connectors for power supply, fuse, earth terminal for system earthing, external SPK jack and D-SUB connectors connected with a Printer, Remote Interface, NBDP (SN-100).
38
12.2. CONTROL CIRCUIT (T-1110)
The Control Circuit consists of MF/HF TX/RX circuit, Local Synthesizer circuit, Power circuit and CPU circuit.
(1) MF/HF RX Circuit
< RX BLOCK DIAGRAM >
RX method is a Double Super-heterodyne receiver using two intermediate frequencies, 1'st IF=49.455MHz and 2'nd IF=455 KHz. Receiving signal in whip antenna pass BPF of 9 bands, then after amplify in RF (Q-53) and in 1'st MIXER (MX2), it is mixed with 1'st LOCAL frequency and demodulated to a first intermediate frequency and the intermediate frequency goes through 49.455MHz X-tal filter (XL5,6) and IF amplifier (Q22) and
(2) MF/HF TX Circuit
in 2'nd MIXER (MX1), it is mixed with 2'nd LOCAL frequency and demodulated to a second intermediate frequency and the demodulated frequency goes through 455KHz X-tal filter (FL3) and IF amplifier (Q21,Q23,Q950) and In 3'rd MIXER (IC15), it is demodulated to a signal of baseband with BFO (Beat Frequency OSC.). The demodulated signal is divided to 3 species as follows.
Amplifiable signal for inner speaker audio.
Amplifiable signal for outer speaker audio.
FSK MODEM (DSC Signal Demodulation) Signal.
< TX BLOCK DIAGRAM >
The baseband signal comes from MIC or NBDP terminal is mixed with BPF, 2'nd LOCAL frequency each in MIXER_3, 2 (IC9, MX1) and goes through each intermediate frequency filters 455KHz (FL3),
49.455MHz(XL1,XL2), each amplifier (Q36,Q35), then is modulated to each intermediate frequencies and the modulated 1'st LOCAL frequency in a final MIXER_1 (MX2) goes through LPF (Low Pass Filter),
BPF of 9bands and then, is input to Power Amplifier (T-1113) and the sufficient amplified signal in PA (Power Amp) goes through a final TX filter (T-1111) and at this time, the harmonic wave (Harmonics) is removed and the signal comes out thru an antenna.
39
(3) Local Synthesizer Circuit
The output of 14MHz OCXO(Over Compensated X-tal Oscillator) is a standard frequency and PLL IC(IC54), VCO(VCO1), DDS(IC56) is output as 1'st LOCAL input signal 49.455~79.4549MHz and 7MHz from output of DDS (IC60) makes 49MHz in 7
(4) Power Supply Circuit
frequency multiplier circuit and use as 2'nd LOCAL. 3'rd LOCAL (BFO, Beat Frequency Oscillator) makes
456.4kHz_125Hz signal directly from DDS (IC62).
Power circuit consists of control circuit of power unit to turn on/off DC-24V in power amplifiable unit, constant voltage circuit to supply DC voltage to be constant voltage in each unit. AUDIO AMP for external speaker and operate through DC INPUT (24V BATTERY).
Main Power Circuit and Power Control Circuit
When switch on
, it controls Relay & goes through Line Filter to supply the power. The output power is +15V / +12V / +8V (voltage for printer) / +7V (Voltage for LCD DIMMER) / +5V. In addition,
it supplies the voltage to NBDP terminal (SN-100), ALARM BOX (SD-25), Printer (OKI or DPU-414).
Protection / Sensor Circuit Operated to turn off the power automatically in a
condition of more than +31V or less than +19V owing to built in a Power sensor circuit and it is built in the circuit preventing conversing voltage to avoid damage. In addition, it is built in Current Sensor to protect
the power circuit and power amp with 0.0025Ω resistance.
40
(5) Control Circuit
The control part consists of CPU(IC30), EEPROM(IC33,37), REAL TIME CLOCK(IC28), CLOCK Generator(X3), RS-232/422 Data Com­device, MODEM, Audio amplifier(IC32), I/O Amplifier, IC(IC22,IC42,IC46,IC48), LCD Contrast / DIMMER Control Circuit and it controls the whole operation of the unit with the data signals of RS­422/232 from front PANEL operation, external connecting devices, interface. CPU device is set by operating PANEL and set synchronizing circuit responded by receiving frequency (selecting channel). Then, according to receiving frequency, set information setting
frequency for SYNTHESIZER or REF/BFO. In addition, the CPU pass signal (LOCAL CONTROL) to indicate various information (receiving frequency, receiving mode, band, width) set by operating panel of controller unit and transmit in control unit. Except this function, in case of interception of power or supply-cease, the CPU control memory degaussing to be back-up by battery built. Memory status before normal of power and in case of normal, possible to rebuild.
12.3. MH/HF Transmitting Filter Circuit (T-1101)
This PCB circuit converts the TX/RX signal as Relay (RY17) by a TX+ (+12V). The signal comes from whip antenna is transferred to a main board (T-1110) through Diminishable Relay, BK Relay, Over-input protect
circuit and it receives a TX signal from PA board (T-
1113) and select the proper filter in a frequency band and then, remove the harmonic wave and transferred to antenna through power sensor circuit.
41
12.4. W/K Receiving Circuit (T-1112)
RX method is a Double Super-heterodyne receiver as such MF/HF receiving method and
1'st intermediate frequency is 49.455MHz and 2'nd is 455 KHz.
14MHz standard frequency supplied from MAIN (T-
1110) is supplied to MIXER making each SYNTHESIZER frequency into a PCB board.
(1) Receiving signal in ANTENNA terminal pass through input over-voltage protecting circuit and BAND-PASS FILTER per frequency (2.187, 5 /
4.207,5 / 6.312 / 8.414,5 / 12.577 / 16.804, 5MHz) and is closing in DSC distress safety frequency. FILTER is response in receiving CHANNEL.
(2) Receiving signal to pass filter is amplified by high-frequency amplifier of width band and is supplied to 1'st MIXER (MX2) through 20MHz LOW
PASS FILTER. The signal is mixed with 1'st local frequency (W/K 1'st LO) supplied from inner SYNTHESIZER and converted to 1'st intermediate frequency (1'st IF)
49.455MHz and it goes through X-tal filter, IF amplifier, then is supplied to 2'nd MIXER and in 2'nd MIXER, is mixed with 2'nd local frequency (W/K 2'nd LO) 49MHz and converted to 2'nd intermediate frequency (2'nd IF) 455KHz.
(3) It consists of AGC circuit controlling amplify of IF AMP by 2'nd IF and the intermediate frequency supplied to 3'rd MIXER is mixed with BFO signal and demodulated to baseband signal and the output-digitalized signal through MODEM is input to CPU.
12.5. Power Amplifier Circuit (T-1113)
The PCB circuit consists of PA+24V Switching circuit effected by TX+KEY signal, 2 pieces of Drive's part, Power Amp part and after the TX
signal input from a main board (T-1110) is sufficient amplified, sent to the TX Filter board of MF/HF (T-1101).
12.6. Front Panel (T-1114)
The PCB circuit consists of LCD, LED, a kind of tap-switch with a power switch, variable resistance controlling brightness, gain receiving, volume,
channel dial and it is put into a front panel along with the connector for inter speaker, hand Mic (SM-
1150).
42
12.7. Function Diagram of Rear Side
ANT : IMPEDANCE 50 MF/HF TX/RX.
ANT. JACK
W/K : IMPEDANCE 50 W/K RX. ANT. JACK
TERMINAL(7) : PRINTER POWER (+8V),
GPS DATA, BK+/- Connector
ATU : ATU BOX(SAT-100) connector
(Control Cable)
AC/DC : Power Supply (SP-1250) connector
(AC/DC Detect)
ALARM BOX : ALARM BOX(SD-250) connector
PRT or D/L(9) :
PRINTER (OKI / DPU-414) connector or PROGRAM Down Load connector
REMOTE(9) : REMOTE INTERFACE connector
MOD or NBDP(15) : Outer MODEM /
NBDP terminal (SN-100) connector
SPK JACK : Outer Speaker connector JACK
EARTH : SYSTEM GROUND
+24V : POWER(+24V) SUPPLY connector
FUSE : 30A FUSE
43
Chapter 13. NBDP Terminal
13.1. NBDP Terminal Main Unit
< NBDP PICTURE >
13.2. Initial Display of Telex (NBDP) mode
Power on, indicate first display as followings
(1) Initial screen function explanation
CH
TX
RX
BAR GRAPH
RF GAIN
CLARIFY
(Adjustment range: ±10Hz)
ATT
OFF : 0dBm, 2 : 20 dBm 1 : 10dBm, 3 : 30 dBm
Indicate calling channel and present channel Set transmitting frequency
Set receiving frequency
Indicate adjusting portion as Bar Graph Adjust the portion of RF GAIN properly using up/down with direction keys.
(0~ 100steps)
The button to adjust the clarity of RX. Using direction button, increase or
decrease to gain the best RX.
Function to reduce the RX gain. This function can be adjusted in 4 steps
using up/down button.
. FRONT PANEL (LCD):
. SPEAKER : Alarm rings when it receives data
. TX LED : Red light on TX LED
. RX LED : Green light blinks while receiving
. POWER SWITCH : SN-100 Power ON/OFF
TX Power
AGC
Vol GRAPH
(2) Initial screen function button explanation [1 DIM] : Adjust the lightness of back light on
LCD display. (5 LEVEL)
[2 LINK] : Automatic Repeat request mode &
FEC mode can be set up by [F2] button
[3 COMM] : Call the registered frequency. [4 VOL-] : Volume down the speaker. [5 VOL+] : Volume up the speaker. [6 CH] : Set the frequency channel [7 TX]: TX : Set TX frequency. [8 Rx]: RX : Set RX frequency. [9 Tune] : is used when user want to do
matching to antenna.
[0 Menu] : Indicate Main Menu
0. [ARQ] : Communicate with Automatic
Repeat Request Mode.
1. [FEC] : Communicate with 1 way Forward Error Correction.
2. [Station Edit] : Register the frequency of the other station.
3. [Station Print] : Print out the frequency of registered the other station.
4. [Macro Command] : Write Macro command. (Write short sentence in 20 words)
5. [Editor] : Edit file and save content.
6. [System set] : Use while adjusting TELEX
mode condition.
CHANNEL, TX/RX FREQUENCY, RF.GAIN, CLARIFY; ATT, AGC, and FUNCTION KEYS are displayed.
or warning signal.
data
Adjust TX power HIGH/MID/LOW
Profit of input signal ON/OFF automatically. Volume sound is displayed on Graphic bar (0~100 levels)
44
7. [NBDP Test] : Transmitting signals of Dot, Mark, Space. Use for testing printer and NBDP TX/RX condition.
8. [LCD-off (F12) : The function of LCD off and in the case that LCD is off, if any button is pressed, LCD is on.
(3) Control function in Keyboard [PgUp] : Adjust channel to next channel. But if
next channel is not registered, it moves to next channel of it.
[PgDn] : Adjust channel to forward channel. But,
if forward channel is not registered, it moves to forward channel of it.
13.3.
UNIT: kHz
(1) Setting TX frequency
a) Press [F7] button on the keyboard. b) Input the frequency with [Number button].
[Ref.] While inputting frequency if press [], [], curser will move.
c) Press [Enter] button.
[Ref.] Available TX Frequency range: 1.6MHz
~ 27.5MHz.
(2) Setting Rx frequency
a) Press [F8] button. b) Input the frequency with [Number button].
[Ref.] While inputting frequency if press [], [], curser will move.
c) Press [Enter] button.
[Ref.] Available RX Frequency range: 95 KHz
~ 29.99999MHz.
(3) Coast Radio Station TX/RX frequency set up a) Press [F3] button, display as followings.
SettingUpTX/RX Frequency
c) Revert the channel you want to communicate using [],[],[],[] button. press [Enter] button. Set TX/RX frequency to registered freq. on channel displaying the first display of NBDP.
(4) Setting TX/RX Freq. by calling channel
a) Press [F6]. b) Input the channel with [Number button]. c) Press [Enter] button.
13.4. [ARQ] mode
(1)
Connecting with the other station by ARQ mode.
Connecting by present adjusting channel. a) Press [F2] button on the keyboard and Link Menu screen shows.
b) Move the cursor with []/[] button to ‘1. [ARQ]’ press [Enter], then it will be connected with other party through [ARQ] mode in present setting Channel.
b) Revert the other station you want to communicate using [],[],[],[] button. press [Enter] button, the following screen will show.
45
(2) Connecting specific station
a) Call the menu pressing [F10] to call SUB MENU key.
b) Move the cursor with []/[] button to ‘0. [ARQ]’ press [Enter] and the following screen will appear.
c) Revert the other station you want to communicate using [],[],[],[] button. press [Enter] button, the following screen will show.
[Ref.] ☞ can be back to forward display
pressing [ESC] button. d) Revert the channel you want to communicate using [],[],[],[] button. press [Enter] button. e) Call the other station with selected frequency displaying next [ARQ] mode first display.
[Ref.] ☞ to stop calling, press [F8] and it will
be back to Telex initial screen. f) If connected, cursor blinks on the left top of the screen.
(3) Communication in ARQ mode
Perform (1) or (2) and operate as below order. a) As long as you can connect with the other station in [ARQ] mode, above screen is displayed. You can keep communicating in this condition. b) After typing the message with keyboard, press
[Enter] button.
[Ref.] Back space - delete one character on
the left. Before you press [Enter] button,
transmitting is not complete.
c) Usable keys in ARQ mode The usable characters:
ABDCDEFGHIJKLMNOPQRSTUVWXYZ1234567890
-? ().'=/+abcdefghijklmnopqrstuvwxyz
[Back space] : Delete one character on the left [Enter] : Send one line. [Left Shift] + [Space] : Convert language.
(English, Russian) [Korean] is selected : [Korean] / [English] shift [English] is selected : [English] [Russian] is selected : [Russian]/[English] shift
[F1] : [1 WHU] - Demand Answer back code of
the other station.
[F2] : [2 Hereis] - Transmit Answer back code
of yourself.
[F3] : [3 TMS] - Transmit the present time [F4] : [4 F.send] - Transmit the file written in
edit mode. (Refer to (4) TX of file)
[F5] : [5 Macro] –You can use the sentence no.
Written in Macro Command (Refer to ‘(5) Macro Command RX)
[F7] : [7 Over] - Convert the direction of
transmitting the message.
[F8] : [8 Stop] - Stop communication. [F9] : [9 VOL-] – Volume can be reduced. [F10] : [0 VOL+] – Volume can be increased.
46
(4) Transmitting file
After performing ‘(1)’ or ‘(2)’, operate the unit as
below order. a) Press Function button [F4] Move the cursor to the file you want using []/[] button Press [Enter] button and the file will be transmitted showing the file contents on the screen.
[Ref.] ☞ pressing [F8] button is able to stop transmitting.
(5) Transmitting of Macro Command
After performing ‘(1)’ or ‘(2)’, operate the unit as
below order. a) Press Function button [F5] Move the cursor to the sentence no. to be transmitted using []/[] button Press [Enter] button and the sentence will be transmitted showing the command contents on the screen.
[Ref.] ☞ pressing [F8] button is able to stop transmitting.
13.5. [FEC] mode
(1) Connecting the other station by Selective FEC mode.
Communication with present selecting Channel
a) Press [F2] button on the keyboard and Link Menu screen shows.
b) Move the cursor to 2. [FEC] with []/[] button Press [Enter] and the following screen shows.
c) Revert the other station you want to communicate using [],[],[],[] button. press [Enter] button, the following screen will show.
[Ref.] to be back to forward display. Press [ESC] button.
d) Revert the channel you want to communicate using [],[],[],[] button. press [Enter] button. e) Call the other station with selected frequency displaying next [SFEC] mode first display.
[Ref.] ☞ to stop calling, press [F8] and it will
be back to Telex initial screen. f) If connected, cursor blinks on the left top of the screen.
47
(2) Connecting with the other station by collective FEC mode. a) Press [F10] button on the keyboard and Main Menu screen shows.
b) Move the cursor to 1. [FEC] with []/[] button Press [Enter] and the following screen shows.
c) Press [Esc] button and [CFEC] mode initial screen shows. Display counter party with the frequency of the channel which was set up on the Telex initial screen.
[Ref.] ☞ to stop calling, press [F8], Then it is
changed to first display of Telex. d) When the call is connected with counter party, cursor blinks on the top left of message screen.
(3) Communication in FEC mode
After performing ‘(1)’ or ‘(2)’ above, operate the
unit as following order. a) When the telex is connected with counter party in FEC mode, initial screen of [CFEC] Mode shows and the communication starts on this condition... b) After typing message with keyboard, press
[ENT] to send.
[Ref.] Transmitting is not available unless
you press [Enter] button.
c) Usable keys in FEC mode The usable characters:
ABCDEFGHIJKLMNOPQRSTUVWXYZ1234567890
-? ().'=/+abcdefghijklmnopqrstuvwxyz
[Back space] : Delete one character on the left [Enter] : Send one line. [Left Shift] + [Space] : Convert language.
(English, Russian) [Korean] is selected : [Korean] / [English] shift [English] is selected : [English] [Russian] is selected : [Russian]/[English] shift
d) The use of [Function] button on the initial screen of [FEC] mode.
[Ref.] Message can be transmitted by [Function] button on the [FEC] mode initial
screen.
Press the function button Press [Enter] button
to transmit.
Select the function with material Press [Enter]
button to transmit.
[F2] : [2 Hereis] - Transmit Answer back code
of yourself.
[F3] : [3 TMS] - Transmit the present time [F4] : [4 F.send] - Transmit the file written in
edit mode. (Refer to (5) TX of file)
[F5] : [5 Macro] - Sentence no. made in Macro
Command can be selected and used. (Refer to‘(6) Macro Command TX article)
[F8] : [8 Stop] - Stop communication. [F9] : [9 VOL-] – Reduce speaker volume [F10] : [0 VOL+] – Increase speaker volume
(4) Receiving of FEC mode
a) If the data of FEC mode is received, automatically, it is printed. And, when it is completely received, automatically, it is saved. b) To open the file, on the initial screen, select [F10][5. Editor] mode [Enter] [F1] (1 Lord) select the file amongRECV 01~RECV 20 Press [Enter] button and you can see the file.
48
(5) Transmitting file
After done above (1) of (2), follow the operation as below. a) Press [F4] and below screen is displayed.
b) Move the cursor to 2. Station Edit with []/[] button Press [Enter] and the following screen shows.
Select the file to transmit with []/[] button press [Enter] button and file will be transmitted
showing the contents of the file on the screen.
(6) Transmitting of Macro Command
After performing ‘(1)’ or ‘(2)’ above, operate the
unit as following order. a) Press [F5] moves the cursor & select sentence no. with
[]/[] button Press [Enter] and the command will be
transmitted showing the contents of command.
[Ref.] pressing [F8] is able to stop transmitting.
13.6. Other sea station or ship station edit & resister frequency
a) Press [F10] button on the keyboard and Main Menu screen shows.
c) Revert the other station you want to communicate using [],[],[],[] button. press [Enter] button, the following screen will show.
d) Move the cursor to [Station input part]
press [Enter].
e) Input [Station name]
Press [Enter] and it will be saved.
f) Move the cursor to [ID input part]
press [Enter] g) Input [ID] Press [Enter] and it will be saved. h) Move the cursor to the [TX] of the channel
press [Enter] button. I) Input [TX Frequency]
press [Enter] and it will be saved... j) Move the cursor to [Rx] of the Channel
press [Enter] k) Input [RX Frequency]
Press [Enter] and it will be saved. L) Press [ESC] and Main Menu
screen shows.
49
13.7. Station print (Counter party & Frequency print)
a) Press [F10] button on the keyboard and Main Menu screen shows.
b)Move the cursor to 4. Macro Command with []/[] button Press [Enter] and the following
screen shows.
b) Move the cursor to 3. Station Print with []/[] button Press [Enter] and the following screen shows.
c) Move the cursor to the counter party you want with []/[] button Press [Enter] and counter party’s registered contents will be printed out and will be back to Main Menu.
13.8.
Can resister TXL number (that is often used) or abbreviated words in 20 words. a) Press [F10] button on the keyboard and Main
Menu screen shows.
Registration of macro command
c) Move the cursor & select the command no. with
[],[],[],[] button[Enter] Type command with keyboard Press [Enter] and it will be saved.
d) Press [ESC] and Main Menu screen shows.
13.9. Editor mode
a) Press [F10] button on the keyboard and Main Menu screen shows.
b)Move the cursor to 5. Editor with []/[] button Press [Enter] and the following screen shows.
50
c) Message can be written and revised. Also FEC, NAVTEX, Received DATA is saved here.
[Ref.] The Function can be used to make message using [function key] on the botton of
Edit message screen.
d) Press [F2] input File-Name[Enter]
Select Slot no. on the Slot Number screenpress [Enter] and it will be saved and it will be
back to Edit screen message screen. e) Press [F1] and you can call the saved message, FEC, NAVTEX, RX data.
[Ref.] From Slot 01 ~ to Slot 20 User can
save the file, from RECV 01 to RECV 20, FEC Received Data, NAVTEX Received Data are automatically saved.
[Ref.] Press [ESC] and back to edit msg
screen.
f) Press [F10] and Edit Exit? Screen shows
select YesPress [Enter] and it will back to Main Menu.
13.10.
a) Press [F10] button on the keyboard and Main Menu screen shows.
Initial setting of system set
(1) Setting of [0. ARQ/FEC 4~ or 5~digit ID] After ‘(b)’
select [0. ARQ/FEC 4- or 5-digit ID] [Enter] Input the ID with [Number] button [Enter] press [ESC] and it will be saved and
back to Main Menu
[Ref.] this will be done during installation
and the user can not change.
(2) Setting of [1. ARQ/FEC 9-digit ID] After ‘(b)’
select [1. ARQ/FEC 9-digit ID][Enter] input the ID with [Number] button[Enter] press [ESC] button and it will be saved and back
to Main Menu
[Ref.] this will be set up during installation
and users can not change.
(3) Setting of [2. Answer Back Code] After ‘(b)’
select [2. Answer Back Code][Enter] input the code with [Enter]press [ESC] button and it will be saved
and back to Main Menu
MMSINo.9 digit ANS/Back code X
ex)
123456789_ABCD_X
[Number & Alphabet]
button
b)Move the cursor to 6. System Set with []/[] button Press [Enter] and the following screen shows.
[Ref.] this will be done during installation and users can not change.
(4) Setting of [3. Collective FEC Receiving]
After ‘(b)’select select [On] or [Off] with [Enter] button press [ESC] and it will be saved and back to
Main Menu
(5) Setting of [4. Maximum FEC Error Ratio]
If RX character error rate in the FEC MODE is higher than the set up value, the RX will stop.
(Example, if error rate set up value is 30%, the error rate is above 30%, the RX will stop.
How to set up After ‘(b)’select
[Enter]input the ratio by [Number] button [Enter]press [ESC] button and it will be saved
and back to Main Menu screen.
[Ref.] Value ranges from 1 to 100.
[3. Collective FEC Receiving]
[4. Maximum FEC Error Ratio]
51
(6) Selecting of
[5. NAVTEX Station Selection]
Function to select NAVTEX station RX. Select the character from A to Z with []/[] button and you
can choose whether you receive with the first character of station or not.
How to set up After ‘(b)’select
[5. NAVTEX Station Selection]
[Enter]NAVTEX Station Selection Set Up screen will showset up ‘O / X’ for the first character of the station with []/[] button & [Enter] buttonpress [ESC] button and it will be saved and back to System Setting Menu.
O : Recognized as the station is possible to receive
NAVTEX broadcasting.
X : Recognized as the station is not possible to receive
NAVTEX broadcasting
(7)
Selecting of [6. NAVTEX Message Selection]
Function to select whether you receive NAVTEX message or not. From C, E to Z, select each
character with []/[] button and you can select whether you receive or not with the first character.
How to set up After ‘(b)’select
[6. NAVTEX Message Selection]
[Enter]NAVTEX Message Selection set up screen showsSet up O/X for the message starting
character with []/[] button & [Enter] button
Press [ESC] and it will be saved and back to System Setting Menu screen.
O : Recognized as NAVTEX starting message.
X : Not Recognized as NAVTEX starting message.
[Ref.] A, B, D is set up as RX always.
(8) Selecting of [7. NAVTEX ID Data Clear]
Use this menu to delete the received Navtex ID
How to set up After ‘(b)’select [7. NAVTEX ID Data Clear]
[Enter]
NAVTEX ID Data Clear?
Screen shows. Select YesPress [Enter] and NAVTEX ID Data will be deleted and back to System Setting Menu screen.
(9) [8. ID Printing] set up
After ‘(b)’select [8. ID Printing] press [Enter] and own country ID is printed out.
(10) [9. Etc. Setting] set up
After ‘(2)’select [9. Etc Setting] press [Enter] and the following screen will show.
Items can be reset with []/[] button & [Enter] button.
0. Language Set : Set up Language Korean Russian English
1. Printer Type : Set up Printer type OKI DPU
2. Printer Port : Local (Main unit printer) Remote (SN-100 printer) can be set up.
[Ref.] regarding the above ‘0, 1, 2 article’, select the item and press [Enter] to shift the
function and select the function you want.
3. Date Set : Set up date
4. Time Set : Set up time
[Ref.] ☞ to set up the above ‘3, 4’, select the item and press [Enter]input
[Number button]
Press [Enter] and it will be saved and input window will disappear.
5. Data Clear : There are sub menu like below.
0. Memory-data Clear
Delete the Station Name.
1. Edit-File Clear
Delete the Macro Command File
& Editor File.
2. FEC-Recv-File Clear
Delete the received FEC-Recv-File.
52
13.11. NBDP test
a) Press [F10] button on the keyboard and
Main Menu screen shows.
b)
Move the cursor to
buttonPress
[Enter]
7. NBDP
and the following screen shows.
with
[
]/[
6. Freq-Shift View : After Freq-Shift Correct,
this shows how well the frequency
[Ref.] press [Enter] button or [ESC] button and it will be back to NBDP Test Menu
screen.
7. Freq-Shift Clear : Function to clear the
[Ref.] Freq-Shift Correct precaution
Operate main unit and terminal after full
]
warm-up
Perform NBDP RX/TX Test and check it is ok.
Check the Freq-Shift View
Perform NBDP RX/TX Test and check the test
result is ok.
compensation is done.
frequency compensation.
13.12. LCD Off
(1) Operation on MENU a) Press [F10] button on the keyboard and Main Menu screen shows.
c) How to operate NBDP Test function Select cursor with []/[] button Press [Enter] and each function operates. If you want to change the function, press [Enter].
0. Mark Transmission : 1.7 kHz -85 Hz signal
is transmitted for 40 seconds.
1. Space Transmission : 1.7 kHz + 85 Hz
signal is transmitted for 40 seconds.
2. Dot Transmission : 1.7 kHz - 85 Hz
signal is transmitted for 40 seconds.
3. Printer Test : Check the printer
status by printing the test print.
4. NBDP Rx/TX Test : Test NBDP terminal
by TX/RX signal.
5. Freq-Shift Correct: Function to compensate
1st Local frequency. Transmitter send 14MHz +1400Hz signal and exclusive receiver receives the signal and compensate the 1st local frequency.
b) Move the cursor to 8. LCD-Off (F12) with
[]/[] button press [Enter] button and LCD screen will be off.
c) Other function is working except LCD off. If any button is pressed or reception is made, LCD will be on.
(2)
How to use this function with function key a) Press [F12] and LCD will be off. b) Other functions are on except LCD. If any button is pressed or RX is done, LCD screen will be on.
53
Chapter 14. NBDP Terminal Circuit
14.1. Overview
SN-100 consists of NBDP Receiver, CONNECTION BOARD, CPU BOARD, PLL BOARD, and POWER SUPPLY. There is power input, SRG-3150DN connector, W/K receiving connector, TX AND RX cable connector, EARTH Plate, keyboard connector, EMC LIGHT connector in the down part of rear side.
14.2. Connection board T-130
As T-130 is PCB which is connecting CPU BOARD and other PCBs, when receiving, the signals that come from NBDP receiver pass active filter consisted of IC5, IC6, IC7, IC8 and then, as it is made square wave as clipping through U5, DOT/PATTERN signal is generated. When receiving,
1.7kHz±85Hz signals are generated through DM1 and then it is delivered to SRG-3150DN.
14.3.
T-132 PCB is NBDP receiving unit which consists of frequency filter and amplifier, MIXER, ATT, AGC, B.K control circuit. After the signals received through MF/HF Antenna amplify with wide amplifier, it is divided into two parts through SPLITTER (SP1)
The inside of NBDP Receiving unit The signal that comes into filter selects the filter
NBDP receiving unit (T-132)
14.6. Function Diagram of Rear Side
assigned each frequency as U4 and U6. And, 1'st LOCAL through IC2, 2'nd LOCAL through IC1, and BFO signal through U1 should be mixed. And then, MARK (1.7kHz-85Hz) and SPACE (1.7 kHz + 80 Hz) signals are generated.
One side is delivered to SRG-3150DN through attenuator and matching tool.
14.4.
As T-133 is SYNTHERSIZER PLL PCB, PLL IC and VCO (POS-100) make up PLL. And, it is outputted to 1st LOCAL input-signal and, as 7 MHZ that is generated from output of PLL IC (IC15) generates 49MHZ in 7 multiply circuit, it is used as 2nd LOCAL. BFO signal is that DM1 received 7MHZ generated
456.7 kHz. Besides, as it transmits and receives with CPU BOARD it generates the signal that controls NBDP receiver.
Local Synthesizer board (T-133)
14.5. Power Circuit (T-025)
Power circuit consists of constant voltage circuit. And while power on, it makes ON main power DC 24V, convert constant voltage +12V, +8V, +5V. If it is overpowered +32V, then power off. Prevention to reversing voltage circuit is built-in.
EMC : Supply power +24 to emg light.
RX ANT IN : Impedance 50MF / HF RX ant
Input jack.
ANT OUT : Connect which send W/K signal
Received from 'RX /ant in' to main unit
Key-Board : Connect between keyboard and
SN-100. Supply +5V. Data. clk etc.
GND : Receiver System Ground
FUSE : 5A Fuse(Printer +24V Fuse)
Printer : Connect to Printer
Printer Power : Connector which supplies
+24V, +8V, GND to printer
FUSE : 3A Fuse(Power Supply Fuse)
Connector To Main Unit :
When connected to SRG-3150DN, transceiver PTT IN, PTT OUT, READY, Data AF+, AF-.
54
Chapter 15. Troubleshooting
15.1. Overview
Cause of TROUBLE in equipment, similar to mechanic cause and electronic cause appeared in external and inner of Equipment. Theses can be block by periodic check. This function has various protecting circuit for trouble of external or inner and blocking damage of circuit and part. However, in case of having trouble and damage, users have to find out problem. i.e., user should recognize first whether badness of equipment-self or external problem. To hold the performance of the initial equipment and the life, it needs regular checking and wrong checking and wrong repair can reduce the performance and life. Therefore, users should know following contents for right checking and repair.
15.2. Measuring Instrument
These equipment products for international radio telephone rule. Maintenance & adjustment of this equipment have to control from correcting test center by rated testers must have testers for maintenance & adjustment daily as follow. (1) Multi-tester for check for check that don't need to be delicated ohm, Voltage, current. (2) TEST PROBE that can be change from high­frequency signal to direct current. (3) High-frequency transit power supply that can be
check of traveling wave of until 1.6MHz27.5MHz
band max 150W500W
(4) 100MHz band max 150W, dummy load of 50Ω (5) Frequency counter that can be check 100MHz
band (6) OSCILLOSCOPE that can be check 100MHz band (7) Other testers
15.3. Maintenance & repair of SRG-3150DN
(1) Antenna
When happened interface (receiving sensitivity degrees, duplex communication interface) during installation or using, have to check to fault of antenna for the first time.
a) Check that antenna control to vertical bearings
(WHIP ANTENNA) correctly.
b) Check that posits metal things around antenna.
c) Is it O.K connect condition & insulation of antenna and connecting parts between transmitter receiver.
d) After connecting the high-frequency wattmeter between this equipment and ATU, measure the progress wave and the reflected wave. If the
VSWR(Voltage Standing Wave Ratio) is less than 2:1, the connection of the antenna, connectors and coaxial cable is stable and the parts have no defect. If the VSWR is more than 2:1, the connection of the antenna, connectors and coaxial cable is bad or the parts have defect.
(2) Power Supply
Check power supply circuit even though volume & squelch control, not appear any sound and display at the front panel after connect power transmitter ­receiver
the rear of transmitter receiver. (Fuse: 30A)
connecting at rear of the transmitter receiver. (Fuse be cut in case of power polarity supply opposite)
supply connector. If 24V ± 10% is (21.626.4V), it's correct. Have to maintenance if over or less, the badness of power
supply equipment (POWER SUPPLY or BATTERY)
1110 PCB (SRG-3150DN), it is badness.
(3) Transmitter
Check follow as when hand set is correct. When transmitter switch hand set can't receiver at the operating, check the connecting condition.
channel selecting is incorrect or selected ban channel.
1113(SRG-3150DN) PCB, if this part is not good, have to change.
and error sign is displayed.
(4) Receiver
After check each switch selecting is correct for the first time, check as follow
antenna or power.
have to change same goods.
EXTERNAL speaker select correctly.
(5) DSC Receiver
After check each switch selecting is correct for the first time, check as follow.
equipment, if this part is not good, have to change same goods.
a) Check is cut the fuse after open fuse holder at
b) Is it correct connects condition power
c) Check power supply voltage at the power
d) Change same goods if check power circuit T-
a) Check antenna & power. Can't receiver when
b) Check T-1110(SRG-3150DN) PCB and T-
c) Not able to receive from unmatched channel
a) Check connects of speaker after check air
b) Check T-1110 PCB, if this part is not goods,
c) Check to become OFF MODE, check MAIN or
a) Check air antenna connection for DSC. b) Check T-1112 or T-1110 PCB of inside of
55
(6) Switch and Display
According to manual, confirm error using or setting value and in case of no error, check as follows.
a) Check T-1114 PCB. In case of error, replacing same product.
b) Check connector and LCD or cable connected to T-1110 PCB of or T-1114 PCB of equipment. In case of error, replacing same product.
15.4. NBDP SN-100
As SN-100 is NBDP terminal, error can happen on transceiver, power supply, CPU BOARD, LCD. When error happens, Check as follow.
(1) Power Supply
Power supply is not working.
Power voltage is +24V in only the case that power supply is connected toSRG-3150DN. And, if there is error, check the power supply switch, the connector cable to SRG-3150DN, fuse (5A), power polarity.
No power on the screen. Firstly, check the +12V on U8 of T-025, +5V on
DC-DC CONVERTER and then, check power supply cable that is connected power supply board and screen. If +12V is not supplied, LCD, CPU BOARD is not operated. If +5V is not supplied, CPU BOARD is not operated.
(2) Screen Display
. Screen display is not able to turn on.
Check that power is correctly supplied to LCD
. Screen is waved or there is white line on the screen.
If the condition of the connect point of LCD connector or of LCD board are bad, connector and board should be cleaned with detergent material that is volatile.
(3) NBDP Data Receiving
. Data is not received.
Firstly, check that ANT is correctly connected. Check that +12V is generated on U1 of T-025
Check that SRG-3150DN receive W/K signal. If SRG-3150DN does not receive W/K signal, Check the third pin (IC4 of T-132) is approximately
3.2V (+ 3.2V is normal). And, check 1ST, 2ND, BFO is supplied.
Check that 1.7 kHz ±85Hz on CN8 of T-132 is generated.
Check that DOT/PATTERN signal on 13th of U9 of T-130 is generated. Check that DOT/PATTERN signal on 18th of IC3 of T-130 is generated.
(4) NBDP Data Transmitting
. Data is not transmitted
Check the connector that is correctly connected between SRG-3150DNand terminals.
Check that 1.7 kHz ±85Hz on the 11th of DM1 of T-130 PCB
Check that the signal is supplied to SRG-3150DN
15.5. Modulation of simple modulator
This equipment is designed to minimize adjust parts and all modulator (except the modulator for power supply) is to be required to manufacturer because it needs an accurate measuring instrument and a skilled technology.
15.6. Caution
(1) In case of checking transmitter unit, please contact dummy load.
(2) In case of separating PCB, pay attention to static electronic.
(3) In case of modulating, use tools for modulation.
(4) In case of checking or modulating, when measuring instrument contact in each circuit, user should match signal of the circuit and PROBE of measuring.
(5) In case of checking or modulating, pay attention to the difference when measuring instrument is Connected into each circuit or not.
(6) All maintenance had better be carried out in our agent or SAMYUNG ENC CO., LTD.
56
Chapter 16. Circuit Diagram & External Diagram
Loading...