Samsung AQT24A5RE/B, UQT24C5RE/B, AQT18A9RE/B, AQ18A9RE, SH18ZA9 Service Manual

...
ROOM AIR CONDITIONER
INDOOR
AQT24A(B)5(6)RE/B AQT18A(B)9(0)RE/B AQ18A(B)9(0)RE SH24AT(B)5 SH18ZA(B)9 AQT24A(B)5(6)RED AQ18A(B)9(0)RE(B)D SH24TA(B)6D SH18ZA(B)0D AQT24C5(6)RE/B AQT18C9(0)RE/B AQ24A(B)5(6)RBD AQT18C9(0)REF
SERVICE
OUTDOOR
UQT24A(B)5(6)RE/B UQT18A(B)9(0)RE/B UQ18A(B)9(0)RE SH24TA(B)5X SH18ZA(B)9X UQT24A(B)5(6)RED UQ18A(B)9(0)RE(B)D SH24TA(B)6DX SH18ZA(B)0DX UQT24C5(6)RE/B UQT18C9(0)RE/B UQ24A(B)5(6)RBD UQT18C9(0)REF
Manual
CONTENTSAIR CONDITIONER
1. Precautions
2. Product Specifications
3. Operating lnstructions and Installation
4. Disassembly and Reassembly
6. Exploded Views and Parts List
7. Block Diagrams
8. PCB Diagrams
9. Wiring Diagrams
10. Schematic Diagrams
1. Precautions
O.K
1. Warning: Prior to repair, disconnect the power cord from the circuit breaker.
2. Use proper parts: Use only exact replace­ment parts. (Also, we recommend replacing parts rather than repairing them.)
3. Use the proper tools: Use the proper tools and test equipment, and know how to use them. Using defective tools or test equip­ment may cause problems later-intermittent contact, for example.
4. Power Cord: Prior to repair, check the power cord and replace it if necessary.
5. Avoid using an extension cord, and avoid tapping into a power cord. This practice may result in malfunction or fire.
6. After completing repairs and reassembly, check the insulation resistance. Procedure: Prior to applying power, mea­sure the resistance between the power cord and the ground terminal. The resistance must be greater than 30 megaohms.
Fig. 1-1 Avoid Dangerous Contact
Fig. 1-2 No Tapping and No Extension Cords
7. Make sure that the grounds are adequate.
8. Make sure that the installation conditions are satisfactory. Relocate the unit if necessary.
9. Keep children away from the unit while it is being repaired.
10. Be sure to clean the unit and its surround­ing area.
Fig. 1-3 No Kids Nearby!
Fig. 1-4 Clean the Unit
1-1Samsung Electronics
MEMO
Samsung Electronics1-2
2. Product Specifications
2-1 Table
Item
Power Sourse
Perfor­mance
Electrical
Rating
Features
Dimensions
&
Weight
Model
Capacity (ISO/SASO) kcal/h
BTU/h
2
Air circulation (High) m Moisture removal (High) Liters/h Available voltage range V Running amperes A Power input kw Power factor % Energy efficiency ratio BTU/wh Compressor locked rotor amperes A Controls/Temperature control Control unit Timer Fan speed Indoor/Outdoor Airflow direction (indoor) Horizontal
Comperssor Refrigerant/Amount charged at rating g Refrigerant control Operation sound Indoor Hi/Mi/Lo dB-A
Outdoor-Hi dB-A Refrigerant tubing connections Max. allowable tubing length at shippint m Refrigerant tube diameter
Refrigerant tube kit/Accessories
Unit dimensions Height mm
Package dimensions Height mm
Weight Net kg
Narrow tube (in.)
Wide tube (in.)
Width mm
Depth mm
Width mm
Depth mm
Shipping kg
/min
Vertical
AQT24A(B)5RE/AQT24A(B)6RE/SH24TA(B)5/AQT24C5(6)RE
Cool Heat
220-240V~, 50Hz
BTU KW BTU KW
6.80KW
24,000BTU/h
14.0 14.0 14.5 14.5
12.5 12.5 13.0 13.0
2.6 2.6 2.7 2.65
86.7 86.7 86.5 84.9
9.2 - 8.9 -
Microprocessor / I.C Thermistor
Wireless remote control
3 Steps and Turbo / 2 Step
Reciprocating(Tecumseh)
Optional / Hanger-plate
Indoor unit Outdoor Indoor unit Outdoor
275
1080
204 372
1151
277
13 16
24,000BTU/h
3.0
198 ~ 264
82
24-Hour ON or OFF
Manual
Auto
R22 / 1,600g
Capillary tube
45 / 43 / 41
58
Flare type
15
6.35(1/4")
15.88(5/8")
6.90KW
638 880 310 704
1023
413
63 67
AQT24A(B)5RB/AQT24A(B)6RB/AQT24C5(6)RB
Cool Heat
220V~, 60Hz
BTU KW BTU KW
24,000BTU/h
14.0 - 14.5 -
13.0 - 13.5 -
2.6 - 2.8 -
90.9 - 94.3 -
9.2 - 8.6 -
-
24,000BTU/h
3.0
187 ~ 253
73
Microprocessor / I.C Thermistor
Wireless remote control
24-Hour ON or OFF
3 Steps and Turbo / 2 Step
Manual
Auto
Reciprocating(Tecumseh)
R22 / 1,600g
Capillary tube
45 / 43 / 41
58
Flare type
15
6.35(1/4")
15.88(5/8")
Optional / Hanger-plate
275
1080
204 372
1151
277
13 16
-
638 880 310 704
1023
413
63 67
Remarks : Rating Conditions are :
Indoor air temperature ISO(50Hz) : 27˚C DB/19.0˚C WB, ISO(60Hz) : 27.0˚C DB/19.5˚C WB Outdoor air temperature ISO : 35.0˚C DB/24.0˚C WB
2-1Samsung Electronics
Table (cont.)
Item
Power Sourse
Perfor­mance
Electrical
Rating
Features
Dimensions
&
Weight
Model
Capacity (ISO/SASO) kcal/h
BTU/h
2
Air circulation (High) m Moisture removal (High) Liters/h Available voltage range V Running amperes A Power input kw Power factor % Energy efficiency ratio BTU/wh Compressor locked rotor amperes A Controls/Temperature control Control unit Timer Fan speed Indoor/Outdoor Airflow direction (indoor) Horizontal
Comperssor Refrigerant/Amount charged at rating g Refrigerant control Operation sound Indoor Hi/Mi/Lo dB-A
Outdoor-Hi dB-A Refrigerant tubing connections Max. allowable tubing length at shippint m Refrigerant tube diameter Narrow tube (in.)
Wide tube (in.) Refrigerant tube kit/Accessories
Unit dimensions Height mm
Width mm
Depth mm Package dimensions Height mm
Width mm
Depth mm Weight Net kg
Shipping kg
/min
Vertical
AQ24A(B)5(6)RBD
Cool Heat
220V~, 60Hz
BTU KW BTU KW
24,000BTU/h-24,000BTU/h
14.0 - 14.5 -
3.0
187 ~ 253
10.0 - 11.3 -
2.4 - 2.6 -
96.6 - 94.5 -
10.0 - 9.23 ­51
Microprocessor / I.C Thermistor
Wireless remote control
24-Hour ON or OFF
3 Steps and Turbo / 2 Step
Manual
Auto
Rotary(SAMSUNG)
R22 / 1,650g
Capillary tube
48 / 46 / 44
61
Flare type
15
6.35(1/4")
15.88(5/8")
Optional / Hanger-plate
Indoor unit Outdoor Indoor unit Outdoor Indoor unit Outdoor
275
1080
204 372
1151
277
13 16
638 880 310 704
1023
413
64.5
68.5
AQT18A(B)9RE/AQT18A(B)0RE/AQT18C9(0)RE
Cool Heat
220-240V~, 50Hz
BTU KW BTU KW
-
18,000BTU/h
5.10KW
20,000BTU/h
13.0 13.0 13.5 13.5
2.5
198 ~ 264
9.5 9.5 10.0 10.0
2.00 2.00 2.10 2.10
87.7 87.7 87.5 87.5
9.0 - 9.5 ­54
Microprocessor / I.C Thermistor
Wireless remote control
24-Hour ON or OFF
3 Steps and Turbo / 2 Step
Manual
Auto
Reciprocating(Tecumseh)
R22 / 1,500g
Capillary tube
45 / 42 / 39
57
Flare type
15
6.35(1/4")
12.70(1/2")
Optional / Hanger-plate
275
1080
204 352
1511
277
13 16
620 787 320 692 909 444
58 62
BTU KW BTU KW
5.60KW
18,000BTU/h
13.0 13.0 13.5 13.5
8.3 8.3 9.0 9.0
1.88 1.88 2.02 2.02
98.5 98.5 97.6 97.6
9.57 - 9.90 -
Microprocessor / I.C Thermistor
3 Steps and Turbo / 2 Step
AQT18C0REF
Cool Heat
220-240V~, 50Hz
5.10KW
20,000BTU/h
2.5
198 ~ 264
53
Wireless remote control
24-Hour ON or OFF
Manual
Auto
Rotary(SAMSUNG )
R22 / 1,500g
Capillary tube
47 / 44 / 41
58
Flare type
15
6.35(1/4")
12.70(1/2")
Optional / Hanger-plate
275
1080
204 352
1511
277
13 16
5.60KW
620 787 320 692 909 444
54 58
Remarks : Rating Conditions are :
Indoor air temperature ISO(50Hz) : 27˚C DB/19.0˚C WB, ISO(60Hz) : 27.0˚C DB/19.5˚C WB Outdoor air temperature ISO : 35.0˚C DB/24.0˚C WB
Samsung Electronics2-2
AQT18A(B)9RB/AQT18A(B)0RB/AQT18C9(0)RB
Cool Heat
220V~, 60Hz
BTU KW BTU KW
18,000BTU/h
13.0 - 13.5 -
10.0 - 10.5 -
2.00 - 2.10 -
90.9 - 90.9 -
9.0 - 9.5 -
Indoor unit Outdoor Indoor unit Outdoor Indoor unit Outdoor
-
20,000BTU/h
2.5
187 ~ 253
52
Microprocessor / I.C Thermistor
Wireless remote control
24-Hour ON or OFF
3 Steps and Turbo / 2 Step
Manual
Auto
Reciprocating(Tecumseh)
R22 / 1,500g
Capillary tube
45 / 42 / 39
57
Flare type
15
6.35(1/4")
12.70(1/2")
Optional / Hanger-plate
275
1080
204 352
1511
277
13 16
620 787 320 692 909 444
58 62
-
AQ18A(B)9RE/AQ18A(B)0RE/SH18ZA(B)9
Cool Heat
220-240V~, 50Hz
BTU KW BTU KW
18,000BTU/h 5.10 20,000BTU/h 5.60
13.5 13.5 14.0 14.0
2.5
198 ~ 264
8.3 8.3 8.5 8.5
1.85 1.80 1.95 1.85
92.8 90.4 95.6 90.7
9.7 - 10.2 ­35
Microprocessor / I.C Thermostat
Wireless remote control
24-Hour ON or OFF
3 Steps and Turbo / 2 Step
Manual
Auto
Rotary(SAMSUNG)
R22 / 1,550g
Capillary tube
45 / 42 / 39
55
Flare type
15
6.35(1/4")
12.70(1/2")
Optional / Hanger-plate
275
1080
204 352
1151
277
13 16
620 787 320 692 909 444
46 50
AQT24A(B)5(6)RED/SH24TA(B)6D
Cool Heat
220-240V~, 50Hz
BTU KW BTU KW
24,000BTU/h 6.80KW 24,000BTU/h 6.90KW
14.0 14.0 14.5 14.5
3.0
198 ~ 264
12.0 12.0 12.5 12.5
2.55 2.55 2.60 2.60
92.4 92.4 90.4 90.4
9.4 2.66 9.2 ­82
Microprocessor / I.C Thermistor
Wireless remote control
24-Hour ON or OFF
3 Steps and Turbo / 2 Step
Manual
Auto
Reciprocating(Tecumseh)
R22 / 1,250g
Capillary tube
45 / 43 / 41
58
Flare type
15
6.35(1/4")
15.88(5/8")
Optional / Hanger-plate
275
1080
204 352
1151
277
13 16
638 880 310 704
1023
413
63 67
2-3Samsung Electronics
Table (cont.)
Item
Power Sourse
Perfor­mance
Electrical
Rating
Features
Dimensions
&
Weight
Model
Capacity (ISO/SASO) kcal/h
BTU/h
2
Air circulation (High) m Moisture removal (High) Liters/h Available voltage range V Running amperes A Power input kw Power factor % Energy efficiency ratio BTU/wh Compressor locked rotor amperes A Controls/Temperature control Control unit Timer Fan speed Indoor/Outdoor Airflow direction (indoor) Horizontal
Comperssor Refrigerant/Amount charged at rating g Refrigerant control Operation sound Indoor Hi/Mi/Lo dB-A
Outdoor-Hi dB-A Refrigerant tubing connections Max. allowable tubing length at shippint m Refrigerant tube diameter Narrow tube (in.)
Wide tube (in.) Refrigerant tube kit/Accessories
Unit dimensions Height mm
Width mm
Depth mm Package dimensions Height mm
Width mm
Depth mm Weight Net kg
Shipping kg
/min
Vertical
AQ18A(B)9(0)RED/SH18ZA(B)0D
Cool Heat
220-240V~, 50Hz
BTU KW BTU KW
18,000BTU/h
13.5 13.5 14.0 14.0
8.1 8.1 7.9 7.9
1.76 1.76 1.70 1.70
94.5 94.5 93.6 93.6
10.2 2.90 11.8 -
5.10
20,000BTU/h
2.5
198 ~ 264
35
Microprocessor / I.C Thermistor
Wireless remote control
24-Hour ON or OFF
3 Steps and Turbo / 2 Step
Manual
Auto
Rotary(SAMSUNG)
R22 / 1,150g
Capillary tube
46 / 44 / 42
55
Flare type
15
6.35(1/4")
12.70(1/2")
Optional / Hanger-plate
Indoor unit Outdoor Indoor unit Outdoor
275
1080
204 352
1151
277
13 16
5.60
620 787 320 692 909 444
46 50
BTU KW BTU KW
18,000BTU/h
13.5 13.5 14.0 14.0
1.77 - 1.80 -
96.9 - 98.6 -
10.17 - 10.57 -
AQ18A(B)9(0)RBD
Cool Heat
220V~, 60Hz
-
20,000BTU/h
2.5
187~253
8.3 - 8.3 -
35
Microprocessor / I.C Thermistor
Wireless remote control
24-Hour ON or OFF
3 Steps and Turbo / 2 Step
Manual
Auto
Rotary(SAMSUNG)
R22 / 1,210g
Capillary tube
46 / 44 / 42
58
Flare type
15
6.35(1/4")
12.70(1/2")
Optional / Hanger-plate
275
1080
204 352
1151
277
13 16
-
620 787 320 692 909 444
46 50
Remarks : Rating Conditions are :
Indoor air temperature ISO(50Hz) : 27˚C DB/19.0˚C WB, ISO(60Hz) : 27.0˚C DB/19.5˚C WB Outdoor air temperature ISO : 35.0˚C DB/24.0˚C WB
Samsung Electronics2-4
2-2 Major Component specifications
Indoor unit
PCB
Fan
&
Fan Motor
S-Motor
Heat
Exch.
Outdoor unit
Comp-
ressor
Fan
&
Fan
Heat
Exch.
Model
Part No. Controls Control circuit fuse Type Dia. and length mm Fan motor model Pols,rpm(at 240V) Normal out W Coil resistance(Ambient temp.20˚C)
Safety devices Type
Operating temp. Open ˚C Run capacitor µF x VAC Type Model Rating Coil resistance (Ambient temp. 25˚C) Coil Rows x Steps Fin pitch mm Face area m
Model
Type Compressor model Normal output W Comperssor oil kind Comperssor oil cc Oil Specific gravity Coil resistance(Ambient temp.25˚C)
Safety devices Type
Overloal relay Operating temp. Open ˚C
Close ˚C
Operating amp(Ambient temp.) Run capacitor µF x VAC Type Dia. and length mm Fan motor model Pols, rpm(at240V) Normal output W Coil resistance(Ambient temp.20˚C)
Safety devices Type
Operating temp. Open ˚C
Close ˚C Run capacitor µF x VAC Coil Rows x Steps Fin pitch mm Face area m
AQT24A(B)5RE/AQT24A(B)6RE/SH24TA(B)5/AQT24C5(6)RE
2
UQT24A(B)5RE/UQT24A(B)6RE/SH24TA(B)5X/UQT24C5(6)RE
2
PD-SH30ZC-00 Microprocessor
250V, 3.15A
Cross-Flow
ø95/L = 842
IC-9430SKC7A
4P, 1350 RPM
40W
MAIN : 137
SUB : 132
17AM034A5
135 ± 5°C
2µF x 450VAC
MSFCC20A03
DC 12V
530
AL-FIN/Copper tube
2 x 15
1.2
0.315
Reciprocating
AWG5532EXC
2660
WITCO LP200 OR EQUIVALENT
INITIAL : 1125 REFILL : 1066
0.92
Start winding : 2.49
Run winding : 0.81
15HM2415-148
Internal Line Break
120
69
73.0 AT 2-10 SECOND 45MF x 370VAC
Propeller
ø460
OSME-906SRC
6P, 850/400 RPM
70W MAIN : 55 SUB : 60 17AM037A5
150±5°C
4µF x 450VAC
AL-FIN / Copper tube
2 x 24
1.7
0.5376
AQT24A(B)5RB/AQT24A(B)6RB/AQT24C5(6)RB
PD-SH30ZC-00
Microprocessor
250V, 3.15A
Cross-Flow
ø95/L = 842
IC-9430SKC7A
4P, 1350 RPM
40W
MAIN : 137
SUB : 132 17AM034A5
135 ± 5°C
2µF x 450VAC
MSFCC20A03
DC 12V
530
AL-FIN/Copper tube
2 x 15
1.2
0.315
UQT24A(B)5RB/UQT24A(B)6RBUQT24C5(6)RB
Reciprocating
AWG5528EXN
2830
WITCO LP200 OR EQUIVALENT
INITIAL : 1125 REFILL : 1066
0.92
Start winding : 1.94
Run winding : 0.88
15HM2415-148
Internal Line Break
120
69
73.0 AT 2-10 SECOND 35MF x 370VAC
Propeller
ø460
OSM-906SRC
6P, 850/400 RPM
70W MAIN : 55 SUB : 65 17AM037A5
150±5°C
4µF x 450VAC
AL-FIN / Copper tube
2 x 24
1.7
0.5376
2-5Samsung Electronics
2-2 Major Component specifications
Indoor unit
Model
Part No.
PCB
Controls Control circuit fuse Type Dia. and length mm Fan motor model Pols,rpm(at 240V)
Fan
Normal out W
&
Fan Motor
S-Motor
Heat
Exch.
Comp-
ressor
Coil resistance(Ambient temp.20˚C)
Safety devices Type
Operating temp. Open ˚C Run capacitor µF x VAC Type Model Rating Coil resistance (Ambient temp. 25˚C) Coil Rows x Steps Fin pitch mm Face area m
Outdoor unit
Model
Type Compressor model Normal output W Comperssor oil kind Comperssor oil cc Oil Specific gravity Coil resistance(Ambient temp.25˚C)
Safety devices Type
Overloal relay Operating temp. Open ˚C
Operating amp(Ambient temp.) Run capacitor µF x VAC Type Dia. and length mm Fan motor model Pols, rpm(at240V)
Fan
Normal output W
&
Coil resistance(Ambient temp.20˚C)
Fan
Safety devices Type
Operating temp. Open ˚C
Run capacitor µF x VAC Coil Rows x Steps
Heat Exch.
Fin pitch mm Face area m
2
Close ˚C
Close ˚C
2
AQ24A(B)5(6)RBD
PD-SH30ZC-02
Microprocessor
250V, 3.15A
Cross-Flow
ø95/L = 842
IC-9430SKC7A
4P, 1350 RPM
40W
MAIN : 137
SUB : 132 17AM034A5
135 ± 5˚C
2µF x 450VAC
MSFCC20A03
DC 12V
530
AL-FIN/Copper tube
2 x 15
1.2
0.315
UQ24A(B)5(6)RBD
Rotary
55A240IUZEM
2220
SUNISO-4GSDT
800
0.92
Common to main : 1.84
-
3HM605-41
Internal Line Break
135
74
95˚F(35˚C)
40µF x 450VAC
Propeller
ø460
OSM-906SRC
6P, 850/400 RPM
70W
MAIN : 55
SUB : 65
17AM037A5
150±5˚C
-
4µF x 450VAC
AL-FIN / Copper tube
2 x 24
1.7
0.5376
AQT18A(B)9RE/AQT18A(B)02RE
PD-SH30ZC-02
Microprocessor
250V, 3.15A
Cross-Flow
ø95/L = 842
IC-9430SKC7A
4P, 1350 RPM
40W
MAIN : 137
SUB : 132
17AM034A5
135 ± 5˚C
2µF x 450VAC
MSFCC20A03
DC 12V
530
AL-FIN/Copper tube
2 x 15
1.5
0.315
UQT18A9RE/UQT18A0RE
Reciprocating
AWG5524EXC
2030
WITCO LP200 OR EQUIVALENT
INITIAL : 1125 REFILL : 1066
0.92
Common to main : 2.98
Common to sub: 1.42
15HM2416-148
Internal Line Break
120
69
73.0 AT 2-10 SECOND 35µF x 450VAC
Propeller
ø405
ASS030AVEB
4P, 950/500 RPM
35W
MAIN : 180
SUB : 200
17AM034A5
135±5˚C
-
2.5µF x 450VAC
AL-FIN / Copper tube
2 x 24
1.7
0.504
AQT18C0REF
PD-SH30ZC-02
Microprocessor
250V, 3.15A
Cross-Flow
ø95/L = 842
IC-9430SKC7A
4P, 1350 RPM
40W
MAIN : 137
SUB : 132
17AM034A5
135 ± 5˚C
2µF x 450VAC
MSFCC20A03
DC 12V
530
AL-FIN/Copper tube
2 x 15
1.5
0.315
UQT18C0REF
Rotary
55A200JT1EM
1920
SUNISO-4GSDT
650
0.92
Common to main : 1.14
Common to sub: 4.13
3HM532-41
Internal Line Break
135
74
95˚F(35˚C)
45µFx450VAC
Propeller
ø405
ASS030AVEB
4P, 950/500 RPM
35W
MAIN : 180
SUB : 200
17AM034A5
135±5˚C
-
3.0µF x 450VAC
AL-FIN / Copper tube
2 x 24
1.7
0.504
Samsung Electronics2-6
AQT18A(B)9RB/AQT18A(B)0RB/AQT18C9(0)RB
PD-SH30ZC-00
Microprocessor
250V, 3.15A
Cross-Flow
ø95/L = 842
IC-9430SKC7A
4P, 1350 RPM
40W
MAIN : 137
SUB : 132
17AM034A5
135 ± 5°C
2µF x 450VAC
AQ18A(B)9RE/AQ18A(B)0RE/SH18ZA(B)9
PD-SH30ZC-00
Microprocessor
250V, 3.15A
Cross-Flow
ø95/L = 842
IC-94309KC7A
4P, 1350 RPM
40W
MAIN : 137
SUB : 132
17AM034A5
135 ± 5°C
2.0µF x 450VAC
AQ18A(B)9(0)RBD
PD-SH30ZC-00
Microprocessor
250V, 3.15A
Cross-Flow
ø95/L = 842
IC-94309KC7A
4P, 1350 RPM
40W
MAIN : 137
SUB : 132
17AM034A5
135 ± 5°C
2.0µF x 450VAC
MSFCC20A03
DC 12V
530
AL-FIN/Copper tube
2 x 15
1.5
0.315
UQT18AB(9)RB/UQT18A(B)0RB/UQT18C9(0)RB
Reciprocating
AWG5520EXN
2070
WITCO LP200 OR EQUIVALENT
INITIAL : 1125 REFILL : 1066
0.92
Common to main : 2.72
Common to sub : 1.32
15HM2311-148
Internal Line Break
120
69
73.0 AT 2-10 SECOND 25MF x 370VAC
Propeller
ø405
ASS030ZTEC
4P, 950/500 RPM
35W
MAIN : 160
SUB : 170 17AM034A5
135±5˚C
MSFCC20A03
DC 12V
530
AL-FIN/Copper tube
2 x 15
1.5
0.315
UQ18A(B)9RE/UQ18A(B)0RE/SH18ZA(B)9X
Rotary
48B180JV1EH
1885
SUNISO-4GSD-T
600
0.92
Common to main : 1.84
Common to sub : -
RAC12016-9622
External Line Break
165˚C
74˚C
120°C : 10.7A 130°C : 9.4A
40µF x 450VAC
Propeller
ø405
ASS030AVEB
4P, 950/500 RPM
35W
MAIN : 180
SUB : 200
17AM037A5
135±5˚C
MSFCC20A03
DC 12V
530
AL-FIN/Copper tube
2 x 15
1.5
0.315
UQ18A(B)9(0)RBD
Rotary
48D190IU1EH
1769
SUNISO-4GSD
600
0.92
Common to main : 1.84
-
RAC12016-9622
External Line Break
165˚C
74˚C
95˚F(35˚C)
40µF x 450VAC
Propeller
ø405
ASS030ZTEC
4P, 950/500 RPM
35W
MAIN : 180
SUB : 200
17AM037A5
135±5˚C
2.5µF x 450VAC
AL-FIN / Copper tube
2 x 24
1.7
0.504
2.5µF x 450VAC
AL-FIN / Copper tube
2 x 24
1.7
0.504
2.5µF x 450VAC
AL-FIN / Copper tube
2 x 28
1.5
0.534
2-7Samsung Electronics
Major Component specifications (cont.)
Indoor unit
PCB
Fan
&
Fan Motor
S-Motor
Heat
Exch.
Outdoor unit
Comp-
ressor
Fan
&
Fan
Heat Exch.
Model
Part No. Controls Control circuit fuse Type Dia. and length mm Fan motor model Pols,rpm(at 240V) Normal out W Coil resistance(Ambient temp.20˚C)
Safety devices Type
Operating temp. Open ˚C Run capacitor µF x VAC Type Model Rating Coil resistance (Ambient temp. 25˚C) Coil Rows x Steps Fin pitch mm Face area m
Model
Type Compressor model Normal output W Comperssor oil kind Comperssor oil cc Oil Specific gravity Coil resistance(Ambient temp.25˚C)
Safety devices Type
Overloal relay Operating temp. Open ˚C
Close ˚C
Operating amp(Ambient temp.) Run capacitor µF x VAC Type Dia. and length mm Fan motor model Pols, rpm(at240V) Normal output W Coil resistance(Ambient temp.20˚C)
Safety devices Type
Operating temp. Open ˚C
Close ˚C Run capacitor µF x VAC Coil Rows x Steps Fin pitch mm Face area m
AQT24A(B)5(6)RED/SH24TA(B)6D
2
UQT24A(B)5(6)RED/SH24TA(B)6DX
WITCO LP200 OR EQUIVALENT
2
PD-SH30ZC-00
Microprocessor
250V, 3.15A Cross-Flow
ø95/L = 842
IC-9430SKC7A
4P, 1350 RPM
40W
MAIN : 137
SUB : 132
17AM034A5
135 ± 5°C
2µF x 450VAC
MSFCC20A03
DC 12V
530
AL-FIN/Copper tube
2 x 15
1.2
0.315
Reciprocating AWG5532EXC
2660
INITIAL : 1125 REFILL : 1066
0.92
Start winding : 2.49
Run winding : 0.81
15HM2415-148
Internal Line Break
120
69
73.0 AT 2-10 SECOND 45MF x 370VAC
Propeller
ø460
OSME-906SRC
6P, 850/400 RPM
70W
MAIN : 55
SUB : 60
17AM037A5
150±5°C
4µF x 450VAC
AL-FIN / Copper tube
2 x 28
1.5
0.543
AQ18A(B)9(0)RE(B)D/SH18ZA(B)0D
PD-SH30ZC-00
Microprocessor
250V, 3.15A
Cross-Flow
ø95/L = 842
IC-94309KC7A
4P, 1350 RPM
40W
MAIN : 137
SUB : 132
17AM034A5
135 ± 5°C
2.0µF x 450VAC
MSFCC20A03
DC 12V
530
AL-FIN/Copper tube
2 x 15
1.5
0.315
UQ18A(B)9(0)RED/SH18ZA(B)0DX
Rotary
48B180JV1EH
1885
SUNSO-4GSD-T
600
0.92
Common to main : 1.84
Common to sub : -
RAC12016-9622
External Line Break
165°C
74°C
120°C : 10.7A 130°C : 9.4A
40µF x 450VAC
Propeller
ø405
ASS030AVEB
4P, 950/500 RPM
35W
MAIN : 180
SUB : 200
17AM037A5
135±5°C
2.5µF x 450VAC
AL-FIN / Copper tube
2 x 28
1.5
0.504
Samsung Electronics2-8
2-3 Dimensions
2-3-1 Indoor Unit
(Front view)
(Remote control)
(Rear view)
2-3-2 Outdoor Unit 2-3-2(a) 24K BTU
275
1080 204
The feature is subject to be varied as a model.
115
2245
(Front view) (Rear view)
310
638
660 880
2-9Samsung Electronics
Product Specifications
2-3-3(b) 18K BTU
320
(Front view) (Rear view)
620
582 787
340
Samsung Electronics2-10
2-4 Pressure Graph
24K BTU
G)
2
Low pressure(kg/cm
Outdoor inlet air D.B.temp.(˚C)
18 BTU
G)
2
Low pressure(kg/cm
Outdoor inlet air D.B.temp.(˚C)
2-11Samsung Electronics
MEMO
Samsung Electronics2-12
3. Operating Instructions and Installation
3-1 Operating Instructions
3-1-1 The Feature of Key in remote controller
NO
NAMED OF KEY
1
(UP)
2
(DOWN)
3
4
5
Power On/Off button to start and stop airconditioner or timer set up.
Temp. up button. To increase the temperatute by the pressing the temperature button.
Temp. down button. To decrease the temperature by the pressing the temperature button.
Each time you press this button Mode is changed in the following order
Press until the appearance. the air condition cools or heats the room as quickly as possible. after 30minutes, the air, the airconditioner is reset automatically to the previous mode.
Press until the appearance. the sleep timer can be used when you are cooling or heating your room to switch the air conditioner off automatically after a perriod of six hours.
Each time you press this button, FAN SPEED is changed in the following order.
FUNCTION OF KEY
: Auto Mode : Fan Only : Cool Mode : Heat Mode : Dry Mode
6
7
8
9
Adjust air flow vertically.
The ON Timer enables you to switch onthe air conditioner automatically after a given period of time that is from 30 minutes to 24 hours. To cancel, press the (Set/Cancel) button.
The Off Timer enables you to switch off the air conditioner automatically after a given period of time that is from 30 minutes to 24 hours. To cancel, press the (Set/Cancel) button.
To select the 5 way function with the remote control, press the 5 way button one or more times until the desired mode is selected. Each time you press the 5 way button
Each 5 way indicator on the indoor unit comes on in order.
3-1Samsung Electronics
Operating Instructions and Installation
3-1-2 Name & Function of Key in remote controller
1. AUTO MODE : In this mode, operation mode(COOL, HEAT) is selected automati­cally by the room temperature of initial operation.
Room Temp Tr21˚C+∆T 21˚C +∆T>Tr
T= -1˚C, -2˚C, 0˚C+1˚C+2˚CT is controlled by setting temperature
up/down key of remote controller
2. COOL MODE : The unit operates according to the difference between the setting and room temperature. (18˚C~30˚C)
3. HEAT MODE : The unit operates according to the difference between the setting and room temperature.(16˚C~30˚C) *Prevention against cold wind : For about 3~5 minutes after initial operation, thermo control or “de-ice”, the indoor fan will either not operate or operate very slowly, then switch to the selected fan speed. This period is to allow the indoor unit's heat­exchanger to prewarm before emitting warm air. *High temperature release function : The outdoor unit for and compressor ON/OFF control for safety operation, when the over­heat is heat exchanger of indoor unit. *De-ice : Deicing operation is controlled by indoor unit's heat exchanger temperature and accumulating time of compressor's operation. De-ice end by sensing of the processing time by de-ice Condition.
Cool Operation (Set Temp : 24˚C+∆T)
Heat Operation (Set Temp : 22˚C+∆T)
Operation Type
4. DRY MODE : Has 3 states, each determined by room temperature. The unit operates in DRY mode. *Compressor ON/OFF Time is controlled compulsorily(can not set up the fan speed, always breeze). *Protective function : Low temperature release. (Prevention against freeze)
5. TURBO MODE : This mode is available in AUTO, COOL, HEAT, DRY, FAN MODE. When this button is pressed at first, the air conditioner is operated “powerful” state for 30 minutes regardless of the set tempera­ture, room temperature. When this button is pressed again, or when the operating time is 30 minutes, turbo operation mode is canceled and returned to the previous mode. *But, if you press the TURBO button in DRY or FAN mode that is changed with AUTO mode automatically.
6. SLEEP MODE : Sleep mode is available only in COOL or HEAT mode. The operation will stop after 6 hours. *In COOL mode : The setting temperature is automatically raised by 1˚C each 1hour When the temperature has been raised by total of 2˚C, that temperature is main­tained. *In HEAT mode : The setting temperature is automatically droped by 1˚C each 1hour. When the temperature has been droped by total of 2˚C, that temperature is main­tained.
7. FAN SPEED : Manual (3 step), Auto (4 step) Fan speed automatically varies depending on both the difference between setting and the room temperature.
Samsung Electronics3-2
Operating Instructions and Installation
8. COMPULSORY OPERATION : For operating the air conditioner without the remote controller. *AUTO : The operating is the same func­tion that AUTO MODE in the remote con­troller. And each time you press the button the 5WAY func-tion is changed as follow.
STD NATURE POWER SAVING SILENCE POWER OFF STD(standard)( ) : General operation
Mode
NATURE( ) : The unit is operated
according to health pattern control
POWER( ) : The unit is operated in
powerful state
SAVING( ) : The unit is operated in
power saving state
SILENCE( ) : The unit is operated
quitely Each mode has Auto, Cool and SLEEP oper­ation designed in advarce.
OFF TIMER : The air Conditioner is turned OFF at a specified time using . *ON TIMER : Only timer LED lights on. *OFF TIMER : Both timer and operation LED lights on.
11. SELF Diagnosis
LED DISPLAY
TIMER
STD
Check Point
Indoor unit room temperature sensor error(open or short)
Indoor unit heat exchanger temperature sensor error(open or short)
Indoor fan mal function
EEPROM error
Option error(option wasn’t set up or option data error)
NATURE POWER SAVING SILENCE
9. SWING : BLADE-H is rotated vertically by the stepping motor. *Swing Set : Press the button under the remote control is displayed on LCD the and the blades move up and down. If the one more time press the button, blades loca­tion is stop.
10. 24-Hour ON/OFF Real Setting Timer. : The air conditioner is turned ON at a specified time using .
LED
:
blinking
: LED off
12. BUZZER SOUND : Whenever the ON/OFF button is pressed or whenever change occurs to the condition which is set up or select, the compulsory operation mode, buzzer is sounded "beep".
3-3Samsung Electronics
Loading...
+ 42 hidden pages