CONTENTSAIR CONDITIONER
1. Installation
2. Disassembly and Reassembly
3. Troubleshooting
4. Exploded Views and Parts List
5. Refrigerating Cycle Block Diagrams
E DB81-00187A(1)
7. Schematic Diagrams
1. Installation
1-1 Refrigerant Refill Procedure
Refill an air-conditioner with refrigerant when refrigerant has been leaked at installing or using
1. Purge air(for new installation only).
2. Turn the 3-way valve clockwise to close, connect the pressure gauge(low pressure side) to the service valve, and open the 3-way valve again.
Suspension hook
3. Connect the tank to refill with Refrigerant
4. Set the unit to cool operation mode.
5. Check the pressure indicated by the pressure gauge(low pressure side).
* Standard pressure is should be 64~78kg/cm
reqular, high operation mode.
6. Open the refrigerant tank and fill with refrigerant until the rated pressure is reached.
* It is recommended not to pour the refrigerant in too
quickly, but gradually while operating a pressure valve.
7. Stop operation of the air conditioner.
2
in a
Compound gauge
For mounting other and of hose when not in use
High pressure gauge
Hand wheel
Finger tight fittings
Connected to high pressure side
Charging line
R-22
8. Close the 3-way valve, disconnect the pressure gauge, and open the 3-way valve again.
9. Close the cap of each valve.
1
1-2 “Pump down” Procedure
Pump down' shall be carried out when an evaporator is replaced or when the unit is relocated in another area.
1. Remove the caps from the 2-way valve and the 3-way valve.
2 Turn the 3-way valve clockwise to close and connect a pres-
sure gauge(low pressure side) to the service valve, and open the 3-way valve again.
2-Way Valve
3. Set the unit to cool operation mode (Check if the compressor is operating.)
4. Turn the 2-way valve clockwise to close.
5 When the pressure gauge indicates "0" turn the 3-way
valve clockwise to close.
6. Stop operation of the air conditioner.
7. Close the cap of each valve.
Relocation of the air conditioner
Refer to this procedure when the unit is
relocated.
1. Carry out the pump down procedure
(refer to the details of 'pump down').
2. Remove the power cable.
3. Disconnect the assembly cable from the
indoor and outdoor units.
4. Remove the flare nut connecting the
indoor unit and the pipe. At this time, cover the pipe of the indoor unit and the other pipe using a cap or vinyl plug to avoid foreign material enter­ing.
3-Way Valve
Relocation of the air conditioner
5. Disconnect the pipe connected to the out­door unit. At this time, cover the valve of the out­door unit and the other pipe using a cap or vinyl plug to avoid foreign material entering.
6. Make sure you do not bend the connection pipes in the middle and store together with the cables.
7. Move the indoor and outdoor units to a new locatioon.
8. Remove the mounting plate for the indoor unit and move it to a new location.
2
2. Disassembly and Reassembly
Stop operation of the air conditioner and remove the power cable before repairing the unit.
2-1 Indoor Unit
No Parts Procedure Remark
Front Grille1 1) Stop the air conditioner operation and block the
main power.
2) Separate tape of front panel upper.
3) Contract the second finger to the left, and right handle and pull to open the inlet grille.
4) Take the left and right filter out.
*Taking off the deodorizing filter.
5) Loosen one of the right fixing screw and sepa­rate the terminal cover.
6) Loosen three fixing screws of front grille.
7) Pull the upper left and right of discharge softly for the outside cover to be pulled out.
8) Pull softly the lower part of discharge and push it up.
Caution;
Assemble the front panel and fix the hooks of left and right.
3
No Parts Procedure Remark
2
3
4
Electrical Parts
(Main PCB)
Ass’y Tray Drain.
Heat Exchanger
1) Do “1”above
2) Take all the connector of PCB upper side out. (Inclusion Power cord)
3) Separate the outdoor unit connection wire from the terminal block.
4) If pulling the Main PCB up. it will be taken out.
1) Do “1”, “2”, above Separate the drain hose from the extension drain hose.
2) Pull tray drain out from the back body.
1) Do “1” and “2”, “3”, above
2) Loosen two fixing earth screws of right side.
3) Separate the connection pipe.
5
Fan Motor and
Cross Fan
4) Separate the holder pipe at the rearside.
5) Loosen the three fixing screws of right and left side.
6) Lifting the heat exchanger up a little to push the up side for separation from the indoor unit.
1) Do “1” “2” ”3” “4”, above.
2) Loosen the fixing two screws and separate the motor holder.
3) Loosen the fixing screw of fan motor. (By use of M3 wrench)
4) Separate the fan motor from the fan.
5) Separate the fan from the left holder bearing.
4
2-2 Outdoor Unit
US07A5(6)MA/US09A5(6)MA
No Parts Procedure Remark
Common Work
1
1) Loosen the fixing two screws and separate the cover E-parts.
2) Separate the connection wire from the terminal block.
3) Loosen five fixing screws and separate the cabi Upper.
2
Fan and Motor
4) Loosen two fixing screws of Ass'y E-part.
5) Loosen nine fixing screws and separate the cabi side.
1) Do “1”, above.
2) Losen four serews and seperaate Guard Fan from front cabinet
5
No Parts Procedure Remark
2) Remove the nut flange (Turn to the right to remove, as it is a left hand screw)
3) Separate the fan.
4) Loosen four fixing screws to separate the motor.
Heat Exchanger
3
1) Do “1”, 2 above.
2) Loosen two fixing screws of left and right side.
3) Disassemble the inlet and outlet pipe by weld­ing.
4) Separate the heat exchanger.
4
Compressor
1) Do “1”, above.
2) Loosen the nut on the terminal cover and open the terminal cover.
3) Disassemble the inlet and outlet pipe of compressor by welding.
4) Disassemble the inlet and outlet pipe of condenser by welding
5) Loosen the three bolts of the lower part.
6) Separate the compressor.
6
US12A5(6)MC
No Parts Procedure Remark
Common Work1 1) Loosen the fixing screw and separate the
Handle-Cabi RH.
2) Separate the connection wire from the terminal block.
3) Loosen 6 fixing screws and separate the upper cabinet.
4) Loosen the fixing screw of Ass'y E-part.
5) Loosen 5 fixing screws and separate the side cabinet.