10/100 MBPS ETHERNET REPEATER WITH 60 W PASSTHROUGH POE

This manual serves the following Model Names:

TER-F01

TER-F01PD

The TER-F01 series is an Ethernet repeater supporting up to 60 watts of Pass-through PoE, providing a simple and cost-effective way to extend Ethernet signals beyond the standard Ethernet 328 foot (100 meter) limit. The TER-F01 can be used to double the distance to 656 feet (200 meters) or multiple units can be combined in series with each unit providing an additional 328 feet (100 meters). The TER-F01 is powered by pass-through PoE from a PoE switch or midspan injector, requiring no local power. Low power consumption ensures that maximum power is made available to the remote PD device.

The standard configuration passes through the PoE to the next device, or as a PD model, which acts as the final PoE unit in the chain and does not pass through the PoE.

INS_TER-F01[PD] 08/12/19 PAGE 1

Samsung TER-F01, TER-F01PD User Manual

INSTALLATION AND OPERATION MANUAL

TER-F01 Series

 

 

FIGURE 1 – TER-F01[PD] EXTENDER

ETHERNET

ETHERNET

Note: Ports are universal, and either can be used as in or out.

Power: Supplied by PSE

Power Consumption: <1 W

FIGURE 3 – INDICATING LEDS

 

 

 

 

 

 

COPPER

 

 

 

 

 

 

GREEN

Solid – No Activity

 

 

Blinking – Activity

 

 

 

 

 

 

 

 

 

YELLOW

Highest Data Rate

 

 

(100Mb)

 

 

 

 

 

 

 

 

 

FIGURE 4 - DIMENSIONS

Dimensions are for a tube module

8.4 cm

 

 

 

 

3.2 cm

[3.3 in]

 

 

 

 

[1.25 in]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.2 cm [1.25 in]

INSTALLATION CONSIDERATIONS

The TER-F01[PD] is supplied as a 3.3 × 1.25 × 1.25 in (8.4 × 3.2 × 3.2 cm) tube module.

Units should be installed in dry locations protected from extremes of temperature and humidity.

WARNING: Unit is to be used with a Listed Class 2 power supply.

IMPORTANT SAFEGUARDS:

A)Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.

B)Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.