Samsung SSA-S2000V User Manual

Standalone RFID Access Controller
User Manual
SSA-S2000V
Standalone RFID Access Controller
User Manual
Copyright ©2010 Samsung Techwin Co., Ltd. All rights reserved.
Tra de mark
Restriction
Samsung Techwin Co., Ltd shall reserve the copyright of this document. Under no circumstances, this docu­ment shall be reproduced, distributed or changed, partially or wholly, without formal authorization of Samsung Tec hwin.
Disclaimer
Samsung Techwin makes the best to verify the integrity and correctness of the contents in this document, but no formal guarantee shall be provided. Use of this document and the subsequent results shall be entirely on the user’s own responsibility. Samsung Techwin reserves the right to change the contents of this document without prior notice.
Warrant y
If the product does not operate properly in normal conditions, please let us know. Samsung Techwin will resolve the problem for free of charge. The warranty period is 3 years. However, the followings are excluded:
If the system behaves abnormally because you run a program irrelevant to the system operation.
Deteriorated performance or natural worn-out in process of time
Sensory phenomenon that does not affect the performance or quality of the product (ex : working noise)
is the registered logo of Samsung Techwin Co., Ltd.
safety information
CAUTION
RISK OF ELECTRIC SHOCK.
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE
PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
This symbol indicates that dangerous voltage consisting a risk of electric shock is present within this unit.
This exclamation point symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
WARNING
To reduce the risk of fi re or electric shock, do not expose this appliance to rain or moisture.
WARNING
Be sure to use only the standard adapter that is specifi ed in the specifi cation sheet.
1. Using any other adapter could cause fi re, electrical shock, or damage to the product.
Incorrectly connecting the power supply or replacing battery may cause explosion, fi re, electric shock, or damage to
2. the product.
Do not connect multiple controllers to a single adapter. Exceeding the capacity may cause abnormal heat generation or fi re.
3.
Securely plug the power cord into the power receptacle. Insecure connection may cause fi re.
4.
When installing the controller, fasten it securely and fi rmly. The fall of controller may cause personal injury.
5.
Do not place conductive objects (e.g. screwdrivers, coins, metal parts, etc.) or containers fi lled with water on top of the
6. controller. Doing so may cause personal injury due to fi re, electric shock, or falling objects.
Do not install the unit in humid, dusty, or sooty locations. Doing so may cause fi re or electric shock.
7.
If any unusual smells or smoke come from the unit, stop using the product. In such case, immediately disconnect the
8. power source and contact the service center. Continued use in such a condition may cause fi re or electric shock.
If this product fails to operate normally, contact the nearest service center. Never disassemble or modify this product in
9. any way. (SAMSUNG is not liable for problems caused by unauthorized modifi cations or attempted repair.)
. When cleaning, do not spray water directly onto parts of the product. Doing so may cause fi re or electric shock.
10.
CAUTION
Do not drop objects on the product or apply strong blows to it. Keep away from a location subject to excessive
1. vibration or magnetic interference.
Do not install in a location subject to high temperature (over 50°C), low temperature (below -30°C), or high humidity.
2. Doing so may cause fi re or electric shock.
If you want to relocate the already installed product, be sure to turn off the power and then move or reinstall it.
3.
Remove the power plug from the outlet when there is a lighting storm. Neglecting to do so may cause fi re or damage
4. to the product.
Keep out of direct sunlight and heat radiation sources. It may cause fi re.
5.
Install it in a place with good ventilation.
6.
Avoid aiming the controller directly towards extremely bright objects such as sun.
7.
Apparatus shall not be exposed to dripping or splashing and no objects fi lled with liquids, such as vases, shall be
8. placed on the apparatus.
The Mains plug is used as a disconnect device and shall stay readily operable at any time.
9.
English _ 3
SAFETY INFORMATION
safety information
FCC Statement
Caution : Any changes or modifi cations in construction of this device which are not expressly approved by the
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
IMPORTANT SAFETY INSTRUCTIONS
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
4_ safety information
party responsible for compliance could void the user’s authority to operate the equipment.
1)
This device may not cause harmful interference, and
2)
This device must accept any interference received, including interference that may cause undesired operation.
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, any cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Read these instructions.
Keep these instructions.
Heed all warnings.
Follow all instructions.
Do not use this apparatus near water.
Clean only with dry cloth.
Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
Do not install near any heat sources such as radiators, heat registers, or other apparatus (including amplifi ers) that produce heat.
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fi t into your outlet, consult an electrician for replacement of the obsolete outlet.
Protect the power cord from being walked on or pinched particularly at plugs, convenience
receptacles, and the point where they exit from the apparatus.
Only use attachments/accessories specifi ed by the manufacturer.
Use only with cart, stand, tripod, bracket, or table specifi ed by the manufacturer, or sold with the apparatus.
Unplug this apparatus when a card is used. Use caution when moving the cart/ apparatus
combination to avoid injury from tip-over.
Refer all servicing to qualifi ed service personnel. Servicing is required when the apparatus has been damaged in any
way, such as powersupply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
contents
PRODUCT INTRODUCTION
7
INSTALLATION AND EXTERNAL
CONNECTION
11
INITIALIZATION
15
READER MODE SETUP
17
USER MANAGEMENT
20
7 Features 8 What’s included 9 At a Glance 10 Cable Color Scheme
11 Cable Selection 12 Bypass Diode Connection 12 I/O Connection 14 External Reader Connection
15 Basic Operations 16 Initialization 16 Forced Initialization with External Line
17 Reader Mode Setup (RF ONLY) 18 Reader Mode Setup (RF + P/W) 18 Reader Mode Setup (PIN ONLY) 19 Reader Mode Setup (RF/PIN Combination
Mode)
19 Enabling Keypad Input for the Card Number
20 To register cards in RF ONLY mode 20 RegIsterIng cards In a combInatIon of RF and
P/W modes
21 To regIster cards In PIN mode 21 RegIsterIng cards In RF card / PIN
combInatIon mode
22 To delete a regIstered card or PIN number
CONTENTS
BASIC SETUP
23
23 Duress Alarm 23 To specify the retry count for an unregistered
ID
24 To specify the keypad input suspension time
if the retry count with an unregistered ID exceeds the limit
24 To specify the delayed start time in Secure
mode
25 To specify the operation time of the Door
Contact Sensor
25 To specify the limited time for the keypad
input
26 To specify the alarm output port for the
dismantled device
26 To open or close the entry door 27 To set or release the QUICK mode 27 To set or release the Toggle mode for the
door relay
English _ 5
contents
I/O TIME SETUP
28
ADVANCED SETTING
33
ADDITIONAL FEATURES
37
28 To specify the output time if the card is
authenticated
29 To specify the output time if the card is not
authenticated
29 To specify the Duress TTL output 30 To specify the alarm output for an input error
of the Door contact Sensor
30 To specify the alarm operation time for AUX 1 31 To specify the alarm operation time for AUX 2 31 To specify the alarm operation time for AUX 3 32 To activate or deactivate the door relay by
the Door Contact Sensor
33 To specify the TTL output operation mode 33 To set the chime bell function 34 To specify the chime bell operation time 34 To specify the input mode for AUX 1 35 To specify the input mode for AUX 2 35 To specify the input mode for AUX 3 36 To specify the input mode for the Exit Button 36 To specify the input mode for the Door
Contact Sensor
37 Mute 37 To specify the use of the tamper alarm 38 To check the output specifi ed for a registered
card user
38 To check the output specifi ed for an
unregistered card user
39 To check the output specifi ed for the Door
Contact Sensor alarm
39 To check the output specifi ed for AUX 1 40 To check the output specifi ed for AUX 2 40 To check the output specifi ed for AUX 3
6_ contents
OTHER INFORMATION
41
TROUBLESHOOTING
44
PRODUCT SPECIFICATIONS
49
41 InItIal Values 42 FunctIon codes
44 Troubleshooting
49 product specifi cations
product introduction
FEATURES
This controller is best designed for a single entry door control (single door access control). This product can save up to 512 cards including the master card, with which you can make an effective management
(such as adding, deleting or changing the settings) of the cards. Its epoxy adhesion and aluminium case guarantees shock-resistance and stable operation in a challenging environment.
This product features 5 external ports that can be connected to the Exit button, Door Contact Sensor, Motion Sensor, and Fire Sensor. It also has 2 relay outputs that can control the door lock and alarm relay. The dual tamper switch triggers an alert if the product is forcibly disassembled.
You can use the keypad to confi gure all settings as necessary. This product is designed for a standalone system.
Single Door Access Control
You can use the RF card (SSA-C100,SSA-C110,SSA-C120) to control a single door.
User Registration
You can register a total of 512 cards including the Master Card.
Keypad Registration
SSA-S2000V is equipped with the built-in keypad that you can use to register, delete cards or confi gure various settings independently.
Buzzer On/Off
With the help of various buzzer tones, you can check the operation status and the current settings and results of the product.
PRODUCT INTRODUCTION
External I/O Pins
SSA-S2000V has 5 input ports and 4 output ports installed (2 relay and 2 TTL outputs). The input ports can receive signals from the Exit button and the Door Contact sensor, while the two relays can be connected to the door lock and the alarm device. One of the TTL output ports can function as a chime bell in connection with the door bell.
Duress Alarm
This is used in a situation where you should open the door inevitably by a robber insisting to do so. Entering the two-digit duress alarm password with pressing the the door normally, while you can set to produce the TTL signal notifying the door is forcibly opened.
button and recognizing the registered card (or card number) can open
Limited Access Tries for an Unregistered Card
You can specify the limit of times to try accessing the door, and the suspended operation time of the keypad for an improper access.
English _ 7
product introduction
WHAT’S INCLUDED
Check if the following items are included in the product package.
SSA-S2000V
Main Unit
Quick Guide
3mm Hex Wrench (x1)
3.5 x 40mm Screws (x4)
3.5 x 25mm Screws (x4)
6 x 30mm Plastic Anchors (x4)
Diodes (x2)
(UF4004, 1N4001~4007)
CD Manual
tGj
Master Card (x1)
8_ product introduction
AT A GLANCE
Front/Rear
PRODUCT INTRODUCTION
3
4
5
SSA-S2000V
6
System Status LED
Keypad
TAMPER SWITCH
3
17-PIN Connector
4
Buzzer
5
Fixing Hole
6
Indicates the operation status of the system.
Use this to confi gure or release settings as appropriate, or enter a card number.
A tamper switch to detect falling from the wall.
Used to connect to the power source or I/O cable.
Piezo buzzer.
Fixing hole for wall-mounting.
English _ 9
product introduction
CABLE COLOR SCHEME
Item Cable Color Signal Line Description
Power
Output
Input
Red DC +12V Power (+12V)
Black GND(-) Earth-grounding for power
Blue with white stripes NC(RL1) Door Relay NC Terminal
Gray with red stripes COM(RL1) Door Control Relay (COM) Port
White with red stripes NO(RL1) Door Relay NO port
Purple with white stripes NC(RL2) Alarm Relay (NC) Port
White COM(RL2) Alarm Relay (COM) Port
Purple NO(RL2) Alarm Relay (NO) Port
Orange with white stripes TTL TTL Output Port
Brown with white stripes CHI Chime Bell Output
Orange EXIT
Yellow with red stripes CONTACT
Green AUX IN 1 Aux Input #1
Green with white stripes AUX IN 2 Aux Input #2
Green with red stripes AUX IN 3 Aux Input #3
Pink DATA_0 Wiegand Data 0 Input Port
Exit button connection port
Door Contact Sensor Connection Port
Sky blue DATA_1 Wiegand Data 1 Input Port
10_ product introduction
Cable Type
Belden #9409, 18 AWG 2 Conductor, Unshielded
Belden #9409, 18 AWG 2 Conductor, Unshielded
installation and external connection
CABLE SELECTION
INSTALLATION AND EXTERNAL CONNECTION
DC12V
SSA-S2000V
Power Supply
RF Reader Lock/Alarm
Item
Power (DC12V)
1
DC Power This Product
Reader (power and data)
2
External Reader This Product
Door Contact Sensor Exit Button
3
Sensor Input Input This Product
Door Lock,
Alarm Device
4
Lock (Alarm) This Product
The cables should be thick enough to allow the maximum current consumed by the reader.
J
Sensor Input
Belden #9409, 18 AWG 2 Conductor, Unshielded
Belden #9512, 22 AWG 4 Conductor, Shielded
Belden #9514, 22 AWG 8 Conductor, Shielded
Belden #9512, 22 AWG 4 Conductor, Shielded
Belden #9514, 22 AWG 8 Conductor, Shielded
Belden #9409, 18 AWG 2 Conductor, Unshielded
Cable Type
English _ 11
installation and external connection
BYPASS DIODE CONNECTION
If you connected an inductor (door locks or alarm device) to the output relay, there should occur a voltage surge while the inductor is turning on and off. If you do not connect a reverse diode to the relay, the surge voltage will cause damage to the electric circuit of the controller. To reduce this surge, it is recommended to connect a reverse diode between the devices.
SSA-S2000V
I/O CONNECTION
Input Connection
Door Contact Sensor
Exit Button
PUSH
SSA-S2000V
DC+
DC-
Lock/Alarm
Door Contact Sensor: Green with red stripes, GND Exit Button: Orange line, GND
Black-
Red+
Cathode Anode
1N4004 ~ 1N4007 or equiv.
DC + 12V
Power Supply
Connect the DC 12V(+) of the power supply unit to the red line.
1.
Connect the GND(-) of the power supply unit to the black line.
2.
- Exit Button Connection
Connect one line of the Exit button to the orange line.
1.
Connect the other line of the Exit button to GND.
2.
- Door Contact Sensor Connection
Connect one line of the door contact sensor to the yellow with red stripes.
1.
Connect the other line of the door contact sensor to GND.
2.
- Auxiliary Input Device Connection (AUX 1 (green), AUX 2 (green with white stripes), AUX 3 (green with red stripes)
Connect one line of the external input device to AUX 1, AUX 2, or AUX 3.
1.
Connect the other line of the external input device to GND(-).
2.
12_ installation and external connection
Output Connection
DOOR RELAY
NO
DOOR LOCK
SSA-S2000V
DOOR
RELAY
COM
Cathode
1N4004~1N4007 or equiv.
Anode
EXIT
CONTACT
AUX IN#1
CHIME
+12V
ALARM RELAY
COM
ALARM RELAY
NO
SIREN
GND
GND
DC 12V
POWER
SUPPLY
PIR SENSOR
GND+12V
CHIME BELL
EXIT
EXIT
BUTTON
DOOR
CONTACT
- Door open (POWER FAIL SAFE) when the power is disconnected from the door lock (Door Relay)
1.
Connect the relay COM line (gray with red stripes for locking the door) to DC +12V.
2.
Connect the relay NC line (blue with white stripes for locking the door) to the plus(+) line of the door lock.
3.
Connect the minus (-) line of the door lock to GND (-).
- Door close (POWER FAIL SECURE) when the power is disconnected from the door lock (Door Relay)
1.
Connect the relay COM line (gray with red stripes for locking the door) to DC +12V.
2.
Connect the relay NO line (white with red stripes for locking the door) to the plus (+) line of the door lock.
3.
Connect the minus (-) line of the door lock to GND (-).
- Alarm Connection (Alarm Relay)
1.
Connect the relay COM (white for the alarm device) to DC +12V.
2.
Connect the relay NO line (purple for the alarm device) to the plus (+) line of the alarm device.
3.
Connect the minus (-) line of the alarm device to GND (-).
- Chime Bell Connection (the chime bell operated by TTL-level signal must be installed in advance.)
1.
Connect the chime bell line (brown with white stripes) of the controller to DC +5V.
2.
Connect the GND line of the power supply unit to GND (-) of the chime bell.
3.
Press
to a0ctivate EthNeT chime bell.
INSTALLATION AND EXTERNAL CONNECTION
English _ 13
installation and external connection
EXTERNAL READER CONNECTION
Wiegand DATA0(Pink)
Wiegand DATA0(Sky blue)
SSA-S2000V
GND
Black-
Red+
DC+12V
- Proximity Reader Connection
1.
Connect the DC 12V(+) of the power supply unit to the plus (+) line of the reader.
2.
Connect the GND(-) line of the power supply unit to the minus (-) line of the reader.
3.
Connect the Wiegand data input line 0 of the proximity reader to the purple line.
4.
Connect the Wiegand data input line 1 of the proximity reader to the sky blue line.
For a list of compliant readers (external readers), see the followings:
- Standard 26bit Wiegand format proximity reader
- Proximity/keypad readers of 4-/8-bit burst format are not supported.
(+)
(-)
14_ installation and external connection
initialization
BASIC OPERATIONS
Initial Status
While the product is working normally, the orange LED indicator blinks every one second.
Predefi ned Operation for a Registered Card
When reading a registered card, it opens the door with the melody.
Exit Button Operation
If you press the Exit button, the door will be opened.
Predefi ned Operation for an Unregistered Card
When reading an unregistered card, it produces an alarm with the melody for two seconds. You can specify the use of the alarm and change the operation time.
Secure Mode Operation
The person who exits the last can set the secure mode using the keypad.
Set Secure mode: Press the Release secure mode: Present and authenticate a registered card or the Master Card to the reader. You can use
the keypad to specify the delayed start time for the Secure mode. (Refer to the delayed start time in Secure mode on page 24.)
button twice and press .
INITIALIZATION
t
Gj

SSA-S2000V
T
EXI
For effective security purposes, you can set to activate the sensors (via auxiliary input ports) only in Secure mode.
M
Duress Alarm
If you are forced to open the door under a robber’s control, enter the Duress password and press with the number of your registered card (or PIN). (See page 23.)
How to use the chime bell
When you have connected and set the chime bell, press to ring the chime bell. (See page 33.)
English _ 15