Installation Manual
COPYRIGHT
This manual is proprietary to SAMSUNG Electronics Co., Ltd. and is protected by copyright.
No information contained herein may be copied, translated, transcribed or duplicated for any commercial
purposes or disclosed to the third party in any form without the prior written consent of SAMSUNG Electronics
Co., Ltd.
TRADEMARKS
Product names mentioned in this manual may be trademarks and/or registered trademarks of their respective
companies.
This manual should be read and used as a guideline for properly installing and operating the product.
This manual may be changed for the system improvement, standardization and other technical reasons without prior
notice.
If you need updated manuals or have any questions concerning the contents of the manuals, contact our Document
Center at the following address or Web site:
Address: Document Center 3rd Floor Jeong-bo-tong-sin-dong. Dong-Suwon P.O. Box 105, 416, Maetan-3dong
Yeongtong-gu, Suwon-si, Gyeonggi-do, Korea 442-600
Homepage: http://www.samsungdocs.com
©2011 SAMSUNG Electronics Co., Ltd. All rights reserved.
INTRODUCTION
Purpose
This manual describes procedure and method for installing Smart MBS RRH-C2A.
Document Content and Organization
This manual consists of 2 Chapters, 6 Annex and Abbreviation as follows:
Smart MBS RRH-P4 Installation Manual
CHAPTER 1. Before Installation
This chapter introduces safety rules that must be understood for installing RRH-C2A and
describes the configuration of RRH-C2A.
CHAPTER 2. Installation of RRH-C2A
This chapter describes the procedure to install RRH-C2A.
ANNEX A. Sector Antenna Installation
This annex describes sector antenna configurations and its installation requirements.
ANNEX B. Feeder Line Work
This annex describes cautions and allowed radius of curvature when installing feeder line.
ANNEX C. Assembling connector
This annex describes the procedure of assembling connector.
ANNEX D. Cleaning Optic Connector
This annex describes the procedure of cleaning the optic connector and cleaning tool.
ANNEX E. Pressure Terminal Assembly
This annex describes the procedure of assembling the pressure terminal.
ANNEX F. Standard Torque
This annex describes the standard torque when assembling the fixing materials.
© SAMSUNG Electronics Co., Ltd. I
INTRODUCTION
ABBREVIATION
Describes the acronyms used in this manual.
Conventions
The following types of paragraphs contain special information that must be carefully read
and thoroughly understood. Such information may or may not be enclosed in a rectangular
box, separating it from the main text, but is always preceded by an icon and/or a bold title.
WARNING
Provides information or instructions that the reader should follow in order to avoid
CAUTION
Provides information or instructions that the reader should follow in order to avoid
personal injury or fatality.
a service failure or damage to the system.
CHECKPOINT
Provides the operator with checkpoints for stable system operation.
NOTE
Indicates additional information as a reference.
Revision History
EDITION DATE OF ISSUE REMARKS
1.0 10. 2011. First Edition
II
© SAMSUNG Electronics Co., Ltd.
SAFETY CONCERNS
The purpose of the Safety Concerns section is to ensure the safety of users and prevent
property damage. Please read this document carefully for proper use.
Symbols
Caution
Indication of a general caution
Smart MBS RRH-P4 Installation Manual
Restriction
Indication for prohibiting an action for a product
Instruction
Indication for commanding a specifically required action
© SAMSUNG Electronics Co., Ltd. III
TABLE OF CONTENTS
Warning
Power and Grounding
Watches, Rings, and Other Metallic Accessories
Do not wear accessories such as watches and rings in order to prevent electrical
Connecting Ground Cable
In cabling, the connection of cables without the connection to the ground cable
WARNING
shock.
may cause the damage of the equipment or the bodily injury of the worker.
Connect the ground cable first.
Installation General
Caution for Laser Beam of Optical Module and Cable
The optical module and cable used in the system emit bright laser beams.
Always handle them with care as there is risk of serious injury if the eyes are
exposed to the laser beam of the optical cable.
Wearing protection gloves and goggles
Make sure to wear protection gloves and goggles to prevent damages from debris
while drilling holes in a wall or ceiling.
IV
© SAMSUNG Electronics Co., Ltd.
Smart MBS RRH-P4 Installation Manual/Ver.2.0
CAUTION
Power and Feeder line
Caution for cleaning the Power Supply
While cleaning the power supply device, take caution that the device does not
come in contact with alien bodies that may cause power failure.
Caution for installing the power cable
To maintain cable gland's rain protection performance, 300 mm or more interval
should be kept straight. According to the radius of curvature of the cable
specification should be considered.
Stainless steel Band
or Cable Tie
≒300mm or more
≒300mm
≒300mm
Caution for cutting the power cable
Cut power cable after installing power cable to RRH-C2A power terminal taking
into account the radius of curvature according to the cable specifications.
When cutting the cable first, the length difference of cable end can be occurred by
cable curvature and the power terminal may cause contact fault.
© SAMSUNG Electronics Co., Ltd. V
TABLE OF CONTENTS
Caution for connecting power cable to power tap (‘2.7.3 Connecting RRH-
- Before connecting power cable to the power tap, connect the appropriate ring lugs
- Insert wire of power cable to ring lug head more than 10mm.
- After inserting power cable, fasten the screw by torque 11 kgf.cm.
Caution When Connecting Optical Cables
Before connecting an optical cable, make sure that there is no dust or foreign
Radius of Curvature of Feeder Line
When installing a feeder line, the radius of curvature of the sections where cables
C2A Power Cable’)
to the power cable ends.
substance on the cross-section of the connector core. If there is any dust or foreign
substance, do not remove it by blowing with your mouth. Remove the dust or
foreign substance by referring to the method of cleaning optic connector.
bent should be larger than the allowed radius of curvature. If the radius of curvature
for the feeder line installation is less than the allowed radius of curvature, it may
affect the performance of the system.
Connection of Feeder Cable Connector
Connecting the feeder cable connector is critical process, so the qualified workers
who finished the related education should perform.
Installation General
Caution when losing External Power Cable Support Bracket(‘2.6 Connecting
ground cable’)
External Power Cable Support Bracket and two cable tie (stainless steel) for
fixing cable are enclosed in RRH-C2A package. Be careful not to lose when
unpacking package.
Managing unused port
Finish unused port of UADU by dust-cap, not making the alien substance flowed.
VI
© SAMSUNG Electronics Co., Ltd.
Smart MBS RRH-P4 Installation Manual/Ver.2.0
Finishing Cable Insertion Hole
Finishing work is required on cable insertion holes (Cable gland, Conduit and
etc.) to prevent entering of any foreign substance, external air and moisture.
- Unused cable insertion hole: Finish cable insertion hole using fishing materials
such as dust cap, rubber packing and etc.
- Cable-installed insertion hole: After installing cable, finish insertion hole using tape,
compressed sponge, rubber packing, silicon, etc. to prevent empty space.
Do not work by yourself
Do not work by yourself in any key process.
Caution for cleaning the Rack
Make sure that worker does not damage installed cables while cleaning the rack.
Cautions When Connecting the CRPI Cable
Failure to observe the CPRI cable connection specified in Table 2.5 may impair
the communication between the CDMA terminal.
RRH-C2A optic cable connection standard
Cable connection standard between UADU CPRI port and RRH-C2A optic port is
different according to the count(One or two) of CDMA UADU(Installed in DU
cabinet).
Connect the optic cable(Refer to the connection standard of 'table 2.6' and 'table
2.7'). Because false connection can cause the fault of call connection, be
cautious.
© SAMSUNG Electronics Co., Ltd. VII
TABLE OF CONTENTS
Caution when Installing the RF antenna
To protect from lightning, the RF antenna must be installed within the shielding
- The protection angle of the lightning rod should be 45 degrees.
angle as shown below, considering the downward distance and the angle from
the tower lightning rod or the antenna pole lightning rod.
Lightning rod
45°
45°
RF Antenna
Finishing Heat Shrink Tube of a Sector Antenna
1) Insert an antenna protection plate.
2) Place the heat shrink tube on the connection point and shrink the heat shrink
tube using a heat gun.
3) Avoid aiming the heating gun toward the antenna’s body as shown in the figure
below.
ntenna Protection Plate
ntenna Jumper Cable
(1/2 in. Feeder Line)
Heat Shrink Tube
(Jelly Type)
ntenna Protection Plate
Heat Shrink Tube
(Jelly Type)
VIII
© SAMSUNG Electronics Co., Ltd.
Smart MBS RRH-P4 Installation Manual/Ver.2.0
California USA Only
This Perchlorate warning applies only to primary CR (Manganese Dioxide)
Lithium coin cells in the product sold or distributed ONLY in California USA
‘Perchlorate Material-special handling may apply, See
www.dtsc.ca.gov/hazardouswaste/perchlorate.’
© SAMSUNG Electronics Co., Ltd. IX
TABLE OF CONTENTS
TABLE OF CONTENTS
INTRODUCTION I
Purpose .................................................................................................................................................. I
Document Content and Organization ..................................................................................................... I
Conventions ........................................................................................................................................... II
Revision History ..................................................................................................................................... II
SAFETY CONCERNS III
Symbols ................................................................................................................................................ III
Warning ....................................................................... ......................................................................... IV
California USA Only ..................................................... ....................................................................... VIII
CHAPTER 1. Before Installation 1-1
1.1 System Configuration ............................................................................................................ 1-1
1.2 Specifications ......................................................................................................................... 1-3
1.3 Cabling .................................................................................................................................... 1-5
1.4 Installation Precaution ........................................................................................................... 1-7
1.5 Pre-Construction Inspection ............................................................................................... 1-12
1.6 Installation Tool .................................................................................................................... 1-13
This page is intentionally left blank.
CHAPTER 2. Installation of RRH-C2A 2-1
2.1 Installation Procedure ............................................................................................................ 2-1
2.2 Foundation Work .................................................................................................................... 2-2
2.2.1 Equipment Arrangement ....................................................................................................... 2-2
2.3 Unpacking and Transporting ................................................................................................. 2- 3
2.3.1 Importing Items ..................................................................................................................... 2-3
2.3.2 Unpacking Items ................................................................................................................... 2-3
2.4 Fixing the System ................................................................................................................... 2-4
2.4.1 Fixing Wall Mount ................................................................................................................ 2-4
2.4.2 Fixing 1 Sector Pole ........................................................................................................... 2-7
X
© SAMSUNG Electronics Co., Ltd.
Smart MBS RRH-P4 Installation Manual/Ver.2.0
2.5 Connecting cable between RRH and Antenna .............................................................. 2-10
2.5.1 Connecting Feeder Line .................................................................................................... 2-10
2.5.2 Connecting RET cable ........................................................................................................ 2-15
2.6 Connecting ground cable .................................................................................................. 2-17
2.6.1 Grounding RRH-C2A .......................................................................................................... 2-17
2.7 Connecting Hybrid cable ..................................................................................................... 2-19
2.7.1 Installing Hybrid cable ......................................................................................................... 2-19
2.7.2 Connecting DU Cabinet side cable .................................................................................... 2-23
2.7.3 Connecting RRH-C2A Power Cable .................................................................................. 2-29
2.7.4 Connecting RRH-C2A CPRI cable ..................................................................................... 2-34
2.7.5 Remaining length of Hybrid cable ...................................................................................... 2-38
2.8 Installation Test .................................................................................................................... 2-41
ANNEX A. Sector Antenna Installation A-1
A.1 Cautions when Installing a Sector Antenna ........................................................................ A-1
A.2 Sector Antenna Layout .......................................................................................................... A-1
A.3 Sector Antenna Installation ................................................................................................... A-2
ANNEX B. Feeder Line Work 오류! 책갈피 가 정의 되 어 있지 않습 니 다.
B.1 When installing the feeder, the cautions ................ 오류! 책갈피가 정의되어 있지 않습니다.
B.2 Antenna Feeder Cable Ground ................................ 오류! 책갈피가 정의되어 있지 않습니다.
B.3 Tower Ground Construction .................................... 오류! 책갈피가 정의되어 있지 않습니다.
ANNEX C. Assembling connector 오류 ! 책갈피 가 정의 되 어 있지 않습 니 다 .
C.1 RJ-45 (Shield type) ................................................... 오류! 책갈피가 정의되어 있지 않습니다.
C.2 RJ-45 (Normal type) .................................................. 오류! 책갈피가 정의되어 있지 않습니다.
C.3 N type-male (LMR-400) ............................................. 오류! 책갈피가 정의되어 있지 않습니다.
C.4 TNC-male (LMR-400) ................................................. 오류! 책갈피가 정의되어 있지 않습니다.
C.5 N type-male (1/2 in. feeder line) ............................... 오류! 책갈피가 정의되어 있지 않습니다.
C.6 Din type-male (1/2 in. Feeder Line) .......................... 오류! 책갈피가 정의되어 있지 않습니다.
C.7 Finishing connector connection with the tape ....... 오류! 책갈피가 정의되어 있지 않습니다.
C.8 How to Shrink the Heat Shrink Tube ....................... 오류! 책갈피가 정의되어 있지 않습니다.
C.8.1 When assembling a connector to the feeder line .... 오류! 책갈피가 정의되어 있지 않습니다.
C.8.2 When connecting a connector to another connector오류 ! 책갈피가 정의되어 있지 않습니다 .
© SAMSUNG Electronics Co., Ltd. XI
TABLE OF CONTENTS
ANNEX D. Cleaning Optic Connector 오류 ! 책갈피 가 정의 되 어 있지 않습 니 다 .
D.1 Cleaning Optic Connector ........................................ 오류! 책갈피가 정의되어 있지 않습니다.
D.2 IBCTM Brand Cleaner ................................................. 오류! 책갈피가 정의되어 있지 않습니다.
D.2.1 IBC
TM
brand type cleaner (P/N 9393) ......................오류 ! 책갈피가 정의되어 있지 않습니다 .
ANNEX E. Pressure Terminal Assembly 오류! 책갈피 가 정의 되 어 있지 않습 니 다.
ANNEX F. Standard Torque 오류! 책갈피 가 정의 되 어 있지 않습 니 다.
ABBREVIATION 오류! 책갈피 가 정의 되어 있지 않습 니 다 .
C ~ U ..................................................................................... 오류! 책갈피가 정의되어 있지 않습니다 .
LIST OF FIGURES
Figure 1.1 RRH-C2A Configuration ......................................................................................... 1-1
Figure 1.2 External Interfaces of RRH-C2A ............................................................................ 1-2
Figure 1.3 Cabling Diagram .................................................................................................... 1-5
Figure 2.1 System Installation & Cable Connection Procedure ............................................... 2-1
Figure 2.2 RRH-C2A Installation Space (1 sector pole type) ................................................... 2-2
Figure 2.3 Fixing Wall Mount (1) ............................................................................................. 2-4
Figure 2.4 Fixing Wall Mount (2) ............................................................................................. 2-5
Figure 2.5 Fixing 1 sector pole (1) .............................. 오류! 책갈피가 정의되어 있지 않습니다.
Figure 2.6 Fixing 1 sector pole (2) .............................. 오류! 책갈피가 정의되어 있지 않습니다.
Figure 2.7 RRH-C2A Feeder Line Connection Diagram ....................................................... 2-10
Figure 2.8 Connecting RRH-C2A Feeder Line (1) ................................................................. 2-11
Figure 2.9 Connecting RRH-C2A Feeder Line (2) ................................................................. 2-12
Figure 2.10 Connecting RET cable ....................................................................................... 2-15
Figure 2.11 RET Cable connector ......................................................................................... 2-16
Figure 2.12 Connecting RRH-C2A Ground cable .................................................................. 2-17
Figure 2.13 Installing Hybrid cable (1)................................................................................... 2-19
Figure 2.14 Installing Hybrid cable (2)................................................................................... 2-20
XII
Figure 2.15 Installing Hybrid cable (3)................................................................................... 2-21
Figure 2.16 Installing Hybrid cable (4) ..................................................................................... 2-22
Figure 2.17 Peeling off the Hy
Figure 2.18 Connecting Hybrid cable (1) .............................................................................. 2-25
Figure 2.19 Connecting Hybrid cable (2) .............................................................................. 2-26
brid Cable Sheath .................................................................. 2-24
© SAMSUNG Electronics Co., Ltd.
Smart MBS RRH-P4 Installation Manual/Ver.2.0
Figure 2.20 Connecting Hybrid cable (3) .............................................................................. 2-27
Figure 2.21 Connecting Hybrid cable (4) .............................................................................. 2-27
Figure 2.22 Connecting RRH-C2A power cable (AWG8) (1) ................................................ 2-29
Figure 2.23 Connecting RRH-C2A power cable (AWG8) (2) ....... 오류! 책갈피가 정의되어 있지
않습니다.
Figure 2.24 Connecting RRH-C2A power cable (AWG8) (3) ................................................ 2-30
Figure 2.25 Connecting RRH-C2A power cable (AWG8) (4) ................................................ 2-32
Figure 2.26 Connecting RRH-C2A power cable (AWG8) (5) ....... 오류! 책갈피가 정의되어 있지
않습니다.
Figure 2.27 Connecting RRH-C2A power cable (AWG8) (6) ....... 오류! 책갈피가 정의되어 있지
않습니다.
Figure 2.28 Connecting RRH-C2A power cable (AWG10) (1) ..... 오류! 책갈피가 정의되어 있지
않습니다.
Figure 2.29 Connecting RRH-C2A power cable (AWG10) (2) ..... 오류! 책갈피가 정의되어 있지
않습니다.
Figure 2.30 Connecting RRH-C2A power cable (AWG10) (3) ..... 오류! 책갈피가 정의되어 있지
않습니다.
Figure 2.31 Connecting RRH-C2A power cable (AWG10) (4) ..... 오류! 책갈피가 정의되어 있지
습니다.
않
Figure 2.32 Connecting RRH-C2A power cable (AWG10) (5) ..... 오류! 책갈피가 정의되어 있지
않습니다.
Figure 2.33 Connecting RRH-C2A power cable (AWG10) (6) ..... 오류! 책갈피가 정의되어 있지
않습니다.
Figure 2.34 Connecting RRH-C2A CPRI cable (1) ............................................................... 2-34
Figure 2.35 Connecting RRH-C2A CPRI cable (2) ............................................................... 2-36
Figure 2.36 Remaining length of Hybrid cable (1) ................................................................ 2-38
Figure 2.37 Remaining length of Hybrid cable (2) ................................................................ 2-39
Figure 2.38 Remaining length of Hybrid cable (3) ................................................................ 2-40
Figure 2.39 RRH-C2A Power Section Test ................. 오류! 책갈피가 정의되어 있지 않습니다.
Figure A.1 Sector Antenna ..................................................................................................... A-2
Figure B.1 Feeder Cable Grounding (1) ..................... 오류! 책갈피가 정의되어 있지 않습니다.
Figure B.2 Feeder Cable Grounding (2) ..................... 오류! 책갈피가 정의되어 있지 않습니다.
Figure B.3 Feeder Cable Grounding (3) ..................... 오류! 책갈피가 정의되
어 있지 않습니다.
Figure B.4 Feeder Cable Grounding (4) ..................... 오류! 책갈피가 정의되어 있지 않습니다.
Figure B.5 Connecting the Tower Ground Cable ........ 오류! 책갈피가 정의되어 있지 않습니다.
Figure C.1 Assembling the RJ-45 connector (Shield type) .......... 오류! 책갈피가 정의되어 있지
않습니다.
© SAMSUNG Electronics Co., Ltd. XIII
TABLE OF CONTENTS
Figure C.2 Assembling the RJ-45 connector (Normal type) ........ 오류! 책갈피가 정의되어 있지
않습니다.
Figure C.3 Assembling the N type-male connector (LMR-400) (1) 오류! 책갈피가 정의되어 있지
않습니다.
Figure C.4 Assembling the N type-male connector (LMR-400) (2) 오류! 책갈피가 정의되어 있지
않습니다.
Figure C.5 Assembling the TNC-male connector (1) .. 오류! 책갈피가 정의되어 있지 않습니다.
Figure C.6 Assembling the TNC-male connector (2) .. 오류! 책갈피가 정의되어 있지 않습니다.
Figure C.7 Assembling the N type-male Connector (1/2 in. Feeder Line) (1)....... 오류! 책갈피가
정의되어 있지 않습니다.
Figure C.8 Assembling the N type-male Connector (1/2 in. Feeder Line) (2)....... 오류! 책갈피가
정의되어 있지 않습니다.
Figure C.9 Assembling the N type-male Connector (1/2 in. Feeder Line) (3)....... 오류! 책갈피가
정의되어 있지 않습니다.
Figure C.10 Assembling the N type-male Connector (1/2 in. Feeder Line) (4)..... 오류! 책
갈피가
정의되어 있지 않습니다.
Figure C.11 Assembling the Din type-male Connector (1/2 in. Feeder Line) (1) .. 오류! 책갈피가
정의되어 있지 않습니다.
Figure C.12 Assembling the Din type-male Connector (1/2 in. Feeder Line) (2) .. 오류! 책갈피가
정의되어 있지 않습니다.
Figure C.13 Finishing connector connection with the tape .......... 오류! 책갈피가 정의되어 있지
않습니다.
Figure C.14 Shrinking the Heat Shrink Tube-Feeder line (1) ...... 오류! 책갈피가 정의되어 있지
않습니다.
Figure C.15 Shrinking the Heat Shrink Tube-Feeder line (2) ...... 오류! 책갈피가 정의되어 있지
않습니다.
Figure C.16 Shrinking the Heat Shrink Tube-Connector (1) ........ 오류! 책갈피가 정의되어 있지
않습니다.
Figure C.17 Shrinking the Heat Shrink Tube-Connector (2) ........ 오류! 책갈피가 정의되어 있지
않습니다.
Figure C.18
Shrinking the Heat Shrink Tube-Connector (3) ........ 오류! 책갈피가 정의되어 있지
않습니다 .
XIV
Figure D.1 Optic Connector Cleaner (IBCTM Brand Type Cleaner: P/N 9393) .... 오류! 책갈피가
정의되어 있지 않습니다.
Figure D.2 Optic Module Cleaning (LC type Jack) ...... 오류! 책갈피가 정의되어 있지 않습니다.
Figure D.3 Optic Cable Connector Cleaning (LC type plug) ....... 오류! 책갈피가 정의되어 있지
않습니다.
Figure D.4 Measuring the Optical Output and Connecting the Optic Connector .. 오류! 책갈피가
정의되어 있지 않습니다.
© SAMSUNG Electronics Co., Ltd.
Smart MBS RRH-P4 Installation Manual/Ver.2.0
Figure E.1 Pressure Terminal Assembly (1) ............... 오류! 책갈피가 정의되어 있지 않습니다.
Figure E.2 Pressure Terminal Assembly (2) ............... 오류! 책갈피가 정의되어 있지 않습니다.
LIST OF TABLES
Table 1.1 System Cabling ....................................................................................................... 1-6
Table 1.2 Allowed Cable Bend Radius ................................................................................... 1-9
Table 1.3 Basic Installation Tools .......................................................................................... 1-13
Table 2.1 Recommended Distances for System Arrangement ............................................... 2-2
Table 2.2 GPS Identification Tag of Feeder line .................................................................... 2-14
Table 2.3 RET Cable-Side Connector Pin Map .................................................................... 2-16
Table 2.4 Hybrid Cable Color Map ........................................................................................ 2-26
Table 2.5 CPRI Cable connection configuration ................................................................... 2-36
Table 2.6 CPRI cable connection standard-When CDMA DU Shelf is one .......... 오류! 책갈피가
정의되어 있지 않습니다.
Table 2.7 CPRI cable connection standard-When CDMA DU Shelf is two .......... 오류! 책갈피가
정의되어 있지 않습니다.
Table 2.8 Construction Status Checklist ............................................................................... 2-42
Table B.1 Curvature Radius of Feeder Cable for Outdoor ........... 오류! 책갈피가 정의되어 있지
않습니다.
Table B.2 Curvature Radius of Feeder Cable for Indoor오류! 책갈피가 정의되어 있지 않습니다.
Table B.3 Curvature Radius of LMR-400 (Based on Times Microwave system) .. 오류 ! 책
정의되어 있지 않습니다.
Table B.4 Connector Connection Torque Value .......... 오류! 책갈피가 정의되어 있지 않습니다.
Table B.5 TGB Installation Example ........................... 오류 ! 책갈피가 정의되어 있지 않습니다 .
Table E.1 Press Size by Cable Thickness .................. 오류! 책갈피가 정의되어 있지 않습니다.
Table F.1 Standard Torque Value for Fastening Bolts . 오류! 책갈피가 정의되어 있지 않습니다.
갈피가
© SAMSUNG Electronics Co., Ltd. XV
TABLE OF CONTENTS
This page is intentionally left blank.
XVI
© SAMSUNG Electronics Co., Ltd.
Smart MBS RRH-P4 Installation Manual
CHAPTER 1. Before Installation
1.1 System Configuration
RRH-C2A Configuration
The following shows the configuration of RRH-C2A.
[Unit: mm]
400
[Top View]
[Front View]
171
598
[Right View] [Left View] [Rear View]
[Bottom View]
Figure 1.1 RRH-C2A Configuration
© SAMSUNG Electronics Co., Ltd. 1-1
CHAPTER 1. Before Installation
External Interfaces of RRH-C2A
The following shows the external interfaces of RRH-C2A.
POWER
[-48 V]
OPTIC_1 RET
OPTIC_0
Ground
ANT 1
[Bottom View]
ANT 0
Figure 1.2 External Interfaces of RRH-C2A
1-2
© SAMSUNG Electronics Co., Ltd.
Smart MBS RRH-P4 Installation Manual/Ver.2.0
1.2 Specifications
Capacity
The following table shows the specifications for RRH-C2A.
Item Specifications
Air Standard FDD CDMA
Configuration 2T2R, with internal duplexer and external Tx filter (optional)
Operating Frequency - Tx : 862~869MHz
- Rx : 817~824MHz
Channel Bandwidth - CDMA : 1.25 MHz
Capacity - CDMA : 5 carriers
Output Power 100W total (50W+50W)
Multiple Antenna - CDMA: 1T2R/2T2R
Baseband Interface 2.4576Gbps, Single-mode, Bi-directional, ~10Km
CRPI version : 4.0 or above
Input Power
The following table shows the power specifications for RRH-C2A.
Item Specifications
Input voltage -48 VDC
Current consumption 9.5 A
Unit Size and Weight
The following table shows the size and weight of RRH-C2A.
Item Specifications
Size (mm, W × D × H) - 400 ×171 × 598 (with External Filter)
- 400 ×171 × 490 (without External Filter)
Weight (kg) - 23.5 (with External Filter)
- 21 (without External Filter)
© SAMSUNG Electronics Co., Ltd. 1-3
CHAPTER 1. Before Installation
Ambient Conditions
This section describes the operating temperature, humidity level and other ambient
conditions and related standard of RRH-C2A.
The following table shows the ambient conditions and related standard of RRH-C2A.
Item Range
Temperaturea) -40~55°C (-40~131°F) without solar load
Humiditya) 10~95%
Altitude 0~1,800 m (0~6,000 ft)
Vibration GR-63-CORE Sec.4.4
Noise (sound pressure level) Max. 65 dBA at distance of 1.5 m (5 ft) and height of 1.0 m (3 ft)
The moisture content must not exceed 0.024 kg per 1 kg of air.
Earthquake
Office Vibration
Transportation Vibration
Electromagnetic compatibility
(EMC)
US Federal Regulation FCC Title47 Part90
a) Temperature and humidity are measured at 1.5 m (59 in) above the floor and at 400 mm (15.8 in) away
from the front panel of the RRH-C2A.
FCC Title47 Part 15 Class B
1-4
© SAMSUNG Electronics Co., Ltd.
Smart MBS RRH-P4 Installation Manual/Ver.2.0
1.3 Cabling
The following shows the cables connected to RRH-C2A.
[Rectifier]
4) Power Cable
[UADU]
5) CPRI Cable
[RF Antenna]
6) RET Cable
[MGB]
3) RRH-C2A Ground Cable
7) RF Cable
1) MGB Ground Cable
2) TGB Ground Cable
※ TGB and Ground Kit are used in case of the 7/8 in. feeder line or more.
Figure 1.3 Cabling Diagram
[TGB]
Feeder Line Ground Cable
(Ground Kit/7/8 in. Feeder Line or more)
© SAMSUNG Electronics Co., Ltd. 1-5
CHAPTER 1. Before Installation
From To Cable
Table 1.1 System Cabling
Underground
Ground
MGB
(Main Ground Bar)
1) MGB Ground Cable
: AWG4/0, GV 95 mm2 × 1C
(However, This can be different, defending on the
standard of service provider)
TGB
(Tower Ground Bar)
2) TGB Ground Cable
: AWG2, GV 25 mm
2
(However, This can be different, defending on the
standard of service provider)
RRH-C2A MGB 3) RRH-C2A Ground Cable
: AWG8, GV 6 mm
2
× 1C
Rectifier 4) Power Cable
: AWG10, 4 mm
2
× 2C(or AWG8,6 mm2 × 2C)
UADU 5) CPRI Cable
: Optic Cable (Single Mode)
RET 6) RET Cable Ass’y (Shield Cable)
Antenna 7) RF Cable (1/2 in. or 7/8 in. Feeder Line)
× 1C
1-6