Samsung SMH1926B/XAA-00, SMH1926S/XAA-00, SMH1926W/XAA-00 Installation Guide

Installation instructions
Over The Range Microwave Oven
BEFORE YOU BEGIN (Read these instructions completely and carefully.}
Save these instructions for local inspector's use.
Observe all governing codes and ordinances.
Note to Installer - Be sure to leave these instructions with the Consumer.
Note to Consumer - Keep these instructions for future reference.
Skill level - Installation of this appliance requires basic mechanical and electrical
= Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered under the Warranty.
READ CAREFULLY. KEEP THESE INSTRUCTIONS.
General information Step=by=step installation guide
important safety instructions ....... 3
Electrical requirements .......... 3
Hood exhaust ................ 4
Damage - Shipment/InstaUation ...... 6
Parts included ............... 6
Tools you will need ............. 7
Mounting space ............... 7
1. Placement of the mounting plate .... 8
A. Removing the microwave oven from the
carton/Removing the mounting plate . . 8
B. Finding the wall studs ........... 8
C. Determining wall plate location under your
cabinet .................. 9
D. Aligning the wall plate .......... 10
2. Ventilation types (choose a, b or c)... 11 A. Outside top exhaust (vertical duct)... 12
A1. Installation procedure for exhaust
adaptor and proper damper operation
check ................ 12
A2. Adjust the exhaust adaptor .... 12
B. Recirculating (non-vented ductless) . . 12
BI. Adapting the microwave blower for
recirculation ............ 12
B2. Installing the charcoal filter .... 13
C. Outside back exhaust (horizontal duct) 14
C1. Adapting the microwave blower for
outside back exhaust ....... 14
3. Installation ................ 15
A. Preparing the rear wall for outside back
exhaust ................. 15
B. Attach the mounting plate to the wall . 15 C. Use the top cabinet template to prepare
the top cabinet ............. 16
D. Mount the microwave oven ....... 16
E. Connecting ductwork for outside top
exhaust ................. 17
4. Before you use your microwave .... 18
iMPORTANT SAFETY iNSTRUCTiONS
This product requires a three-prong grounded outlet. The installer must perform a ground continuity check on the power outlet box before
beginning the installation to insure that the outlet box is properly grounded. If not properly grounded, or if the outlet box does not meet
) )
I
electrical requirements noted (under ELECTRICAL
REQUIREMENTS), a qualified electrician should be employed to correct any deficiencies.
CAUTION: For personal safety, remove house fuse or open circuit
breaker before beginning installation
to avoid severe or fatal shock injury.
CAUTION: For personal safety, the mounting surface must be capable of supporting the cabinet load, in addition to the added weight of this 69 pound product, plus additional oven
loads of up to 50 pounds or a total weight of
109 pounds.
CAUTION: For personal safety, this product cannot he installed in cabinet arrangements such as an island or a peninsula. It must he
mounted to BOTH a top cabinet AND a wall.
NOTE: For easier installation and personal safety, it is recommended that two people
install this product.
IMPORTANT - PLEASE READ CAREFULLY.
FOR PERSONAL SAFETY, THiS APPLIANCE
MUST BE PROPERLY GROUNDED TO AVOID SEVERE OR FATAL SHOCK.
You should have the wall receptacle and circuit
checked by a qualified electrician to make sure
the receptacle is properly grounded.
If you have a standard two-prong wall receptacle, it is very important to have it replaced with a properly grounded three= prong wall receptacle, installed by a qualified
electrician.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT, DEFORM OR REMOVE ANY OF THE PRONGS FROM THE POWER CORD. DO NOT USE WITH
AN EXTENSION CORD.
ELECTRICAL
REQUIREMENTS
Product rating is 120 volts AC, 60 Hertz, 14.5 amps and 1.7 kilowatts.This product must be connected to a supply circuit of the proper voltage and frequency. Wire size must conform to the requirements of the National Electrical Code or the prevailing local code for this kilowatt rating. The power supply cord and plug should be brought to a separate 15 ampere branch circuit single grounded
outlet. The outlet box should be located in the cabinet above the microwave oven. The outlet box
and supply circuit should be installed by a qualified electrician and conform to the National Electrical
Code or the prevailing local code,
The power cord of this appliance is equipped with a three-prong (grounding) plug which
mates with a standard
three-prong (grounding} wail receptacle to
minimize the possibility
of electric shock hazard from this appliance.
SMH1816_XAA-DE68-03943A-02-EN_120725.indd 3 2012-07-25 Z_7:49:11
HOOD EXHAUST
NOTE: Read these next two pages only if you plan to vent your exhaust to the outside, if you plan to recirculate the air back into the room, proceed to page 1t.
OUTSIDE TOP EXHAUST (EXAMPLE ONLY)
The followin( chart contains an example of one possible ductwork installation.
DUCT PIECES EQUIVALENT x NUMBER = EQUIVALENT
Roof 24 ft. 24 ft.
Cap x (1) =
12 ft. Straight Duct(d" Round) 12 ft. x (1) = 12 ft.
_ Rectangular-to-
Equivalent lengths of duct pieces are based on actual tests and reflect requirements for good venting performance with Total Length = 41 ft. any vent hood.
iMPORTANT: If a rectangular-to-round transition adaptor is used, the bottom corners of the damper will have to be
cut to fit, using the tin snips, in order to allow free movement of the damper.
Round Transition 5 ft. x (1) = 5 ft.
Adaptor*
LENGTH USED LENGTH
OUTSIDE BACK EXHAUST {EXAMPLE ONLY}
The followin( chart contains an example of one possible ductwork installation.
DUCT PIECES EQUIVALENT x NUMBER = EQUIVALENT
Cap x (1)
Wall 40 ft. 40 ft.
LENGTH USED LENGTH
x 10" Rectangular) 3 ft. x (1) = 3 ft.
[3 3ft'StraightDuct(31A"
(_ 90 ° Elbow 10 ft. x (2) = 20 ft.
Equivalent lengths of duct pieces are based on actual tests and reflect requirements for good venting performance with Total Length = 63 ft. any vent hood.
NOTE: For back exhaust, care should be taken to align the exhaust with the space between studs, or the wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
SM H1816_XAA-DE68-03943A-02-EN_120725.indd 4 2012-07-25 7:49:11
NOTE: If you need to install ducts, note that the total duct length of 3 1A'x 1O-rectangular or 6"diameter
round duct should not exceed 140 equivalent feet.
Outside ventilation requires a HOOD EXHAUST DUCT.
Read the following carefully.
NOTE: It is important that venting be installed using the most direct route and with as few elbows as
possible. This ensures clear venting of exhaust and
helps prevent blockages. Also, make sure dampers swing freely and nothing is blocking the ducts.
Exhaust connection:
The hood exhaust has been designed to mate with a standard 3 1A'x 1O-rectangular duct.
If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less
than a 6"diameter duct.
Maximum duct length:
For satisfactory air movement, the total duct length of 3 Y4"x 10-rectangular or 6" diameter round duct should
not exceed 140 equivalent feet.
Elbows, transitions, wall and roof
caps, etc., present additional resistance to airflow
and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent lengths of all transitions and adaptors plus the length of all straight duct sections. The chart below shows you how to calculate total equivalent ductwork length using the equivalent length in feet of some typical ducts.
DUCT PIECES x =
Rectangular-to-Round
Transition Adaptor*
Wall Cap 40 ft. x ( ) = ft.
(_ 90 ° Elbow 10 ft. ft.
©
45 Elbow 5 ft. x ( ) = ft.
90 ° Elbow 25 ft. ft.
(_ 45 ° Elbow 5 ft. ft.
Roof 24 ft. ft.
Oap x ( ) =
Straight Duct 6" Round or 3 Y4" 1 ft. x ( ) = ft.
x 10" Rectangular
transition adaptor is used, the bottom are based on actual tests and reflect corners of the damper will have to be cut the requirements for good venting
* iMPORTANT: If a rectangular-to-round Equivalent lengths of duct pieces
to fit, using tin snips, in order to allow free performance with any vent hood. movement of the damper.
EQUIVALENT NUMBER EQUIVALENT
LENGTH USED LENGTH
5 ft. ft.
x ( ) =
x ( )
x
x
( )
( )
Total Buctwork = ft.
SM H 1816_XAA-DE68-03943A-02-EN_120725.indd 5 2012-07-25 7:49:11
DAMAGE - SHIPM ENT/INSTALLATION
If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or
replacement.
If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.
If the unit is damaged by the installer (if other than the customer), repair or replacement must be made by
arrangement between the customer and installer.
PARTS iNCLUDED
HARDWARE PACKET
PART QUANTITY
Wood Screws
(¼"x 2")
Toggle Bolts
(and wing nuts) 2 (s/iG"x 3")
Self-aligning
j Machine Screws 2
(¼"- 28 x 3 ¼")
Nylon Grommet (for metal cabinets)
You will find the installation hardware contained in a
packet with the unit. Check to make sure you have all
these parts.
NOTE: Some extra parts are included.
1
1
ADDITIONAL PARTS
PART QUANTITY
Top Cabinet Template
Rear Wall Template 1
_ Installation 1
Instructions