Samsung SLP-T400, SRP-275, SRP-350plus, SRP-370, SRP-350 User Manual

...
User's Manual
Ethernet Interface
Rev. 4.00
SRP-270
SRP-275 SRP-350 SRP-350plus SRP-370 / 372 SRP-770 / 770II SLP-T400
http://www.samsungminiprinters.com
Ethernet
- 2 -
■ Table of contents
1. Manual Information................................................................................................. 3
2. Interface card and available printer ....................................................................... 3
3. Specifications......................................................................................................... 4
3-1. Hardware version ............................................................................................4
3-2. Configuration Tool........................................................................................... 4
3-3. Virtual Driver................................................................................................... 5
3-4. Hardware version and Configuration Tool...................................................... 5
3-5. Details of interface card.................................................................................. 5
4. How to install ......................................................................................................... 6
5. Static IP interface set up........................................................................................ 7
5-1. Configuration Tool........................................................................................... 7
5-2. Web Server ....................................................................................................12
6. DHCP interface set up.......................................................................................... 17
6-1. Configuration Tool.........................................................................................17
6-2. Web Server ....................................................................................................21
7. Firmware update .................................................................................................. 22
7-1. Configuration Tool.........................................................................................22
7-2. Web Server ....................................................................................................25
8. Ethernet test by using Windows test page ........................................................... 27
[Appendix 1] Printer DIP switch set up ................................................................. 33
[Appendix 2] Function Key set up ........................................................................... 34
[Appendix 3] Factory Reset..................................................................................... 35
V 4.00
- 3 -
1. Manual Information
The purpose of this manual is to provide information on the operation and usage instructions of the Ethernet Interface for the BIXOLON Printers.
2. Interface card and available printer
Ethernet
Printer
SRP-270 SRP-350
SRP-350Plus
SRP-370 / 372
SRP-275 IFC-E TYPE
SRP-770 RIF-EN10B V3.x.x
Interface Card
IFA-E TYPE
IFA-E TYPE
Hardware version
V4.x.x V3.x.x V2.x.x V1.x.x
V4.x.x V3.x.x
V4.x.x V3.x.x
그림
SRP-770II SLP-T400
RIF-EN10B V3.x.x
ON Board V4.x.x Integrated printer
V 4.00
Ethernet
- 4 -
3. Specifications
3-1. Hardware version
Hardware version is marked on the label on the interface card bracket. Interface Ver: V4.X.X has Function key while Ver:V3.X.X doesnt have it.
IFA-E TYPE IFC-E TYPE
[Note]
- The DIP switch on the interface board should always be OFF.
3-2. Configuration Tool
BIXOLON provides 2 types of network and serial communication set up utilities as a below;
- Configure_V4.x.x.exe
- Web Server
V 4.00
Ethernet
- 5 -
3-3. Virtual Driver
- It converts output of Serial (COM) port into output of Ethernet (TCP/IP) port.
- It is available for Windows 2000, XP and 2003 server.
3-4. Hardware version and Configuration Tool
Hardware
version
V4.x.x
V3.x.x
V2.x.x RIF-350E SRP-270,350 Ethernet_V2.0 10 Base-T V1.x.x RIF-350E SRP-270,350 Ethetnet_V1.3 10 Base-T
[Note]
In case the hardware version is V4.X.X or higher, use Configure_V4.x or Web server. You can simply use Web Server on Internet Explorer.
3-5. Details of interface card
Network interface 10/100 Base-T All in one (Auto detection) Protocol TCP, UDP, IP, ICMP, ARP IP mode static IP, DHCP (Dynamic Host Configuration Protocol) RX buffer 2 KByte Flow control Hardware (RTS/CTS) Baud rate (Serial speed) 1200 ~ 230400 bps
Interface card
IFA-E
IFC-E SRP-275
ON Board
IFA-E
IFC-E SRP-275
RIF-EN10B
Details
Printer
SRP-270,350 SRP-370,372 SRP-350Plus
SRP-770II
SLP-T400 SRP-270,350 SRP-370,372 SRP-350Plus
SRP-770
SRP-770II
SLP-T400
Configuration Tool
file
Configure_V4.x
Web Server
Configure _V3.x
Network
interface
10/100 Base-T
All in one
V 4.00
- 6 -
4. How to install
Cross cable
1) Check the interface version
[Note]
- Each version uses its own Configuration Tool.
2) Turn of the printer and insert the interface card.
3) Set the baud rate (Serial speed)
- SRP-270,275: Max. 19200 bps
- SRP-350: Max. 57600 bps
- SRP-350Plus: Max. 115200 bps
- SRP-370,372: Max. 115200 bps
- SRP-770: Max. 115200bps
- SRP-770: Max. 230400 bps
- SLP-T400: Max. 230400 bps
[Note]
- The baud rate (Serial speed) of the interface card is from 1200 ~ 230400 bps.
- The baud rate (Serial speed) of the printer can be set with DIP switch (Refer to [Appendix 1])
4) Connect LAN cable to the interface card and turn on the printer.
(1) Use direct cable to connect to HUB (Switch).
Ethernet
V 4.00
(2) Use cross cable to connect to LAN card of computer.
- 7 -
5. Static IP interface set up
5-1. Configuration Tool
1) Turn on the printer.
2) Execute Configure Tool.
Ethernet
[Note]
- Use proper Configuration Tool dependent on hardware version
3) Click Search.
V 4.00
- 8 -
4) Select MAC Address in Board list and set up Network Setting.
MAC Address
Ethernet
[Note]
- If many MAC addresses appear, refer to the MAC address on the label of the interface
card.
- Ask the Network administrator IP and its related information.
- If you are not aware of Subnet Mask, refer to the below.
When the IP address is
(1) 1~126.xxx.xxx.xxx: Subnet Mask: 255.0.0.0
(2) 128~191.xxx.xxx.xxx: Subnet Mask: 255.255.0.0
(3) 192~223.xxx.xxx.xxx: Subnet Mask: 255.255.255.0
For example, when the IP address is 192.168.192.321,
Subnet mask is 255.255.255.0.
- If you are not aware of Gateway,
(1) When the Network is connected to Internet (Router or Server computer), refer to
the Network setting of other computers on the Network.
(2) When the Network is connected to Internet (Router or Server computer), enter
0.0.0.0 for Gateway.
V 4.00
- 9 -
5) Enter value at Local Port.
Ethernet
[Note]
- Default value is 9100. Choose from 6000 to 10000.
6) Set Inactivity Time as ‘0’.
[Note]
- Default value is 0. Choose from 0 to 65535.
- When you set Inactivity time, Ethernet interface will disconnect by force after
designated time. When you set 0, Forced disconnection function is not available.
V 4.00
- 10 -
7) Set baud rate (Speed) at Serial Setting
Ethernet
[Note]
- The baud rate (Speed) should be same as the baud rate of the printer.
(Refer to [Appendix 1])
- Highest baud rate (Speed) can be used.
8) When setting finishes, click Setting.
[Note]
Successfully finished set up Unsuccessfully finished set up
- When setting doesn’t finish correctly, try again.
V 4.00
- 11 -
9) Click Exit to finish set up.