Samsung SG626, SG628, BG626, BG678, SG676 Troubleshooting

...
7. Troubleshooting
Precautions
1. Is the power cord well connected to wall outlet?
2. Refer to the reference
1) No power
Start
Measure C03 (1000M/35V)
Measure IC02 OUT voltage
Measure IC03 OUT voltage
DC-Trans primary
power input?
Y
DC-Trans secondary
power input?
Y
Main PCB fuse
brown out?
N
Power input to IC02?
Y
DC 12V output
from IC02?
Y
DC 5V output
from IC03?
N
Are wires connected to
panel securely?
Y
Panel PCB Ass’y
is OK?
Y
OK
N
Check wires
N
Replace DC-Trans
N
Replace fuse
N
Check BD05 – 08
N
Check IC02(MC7812)
N
Check IC03(KA7805)
N
Check wire connection
Y
Reference 1
(Page. 38)
28 Samsung Electronics
2) Compressor does not run
Precautions
1. Compressor does not operate in 5 minutes after power ON and compressor OFF.
2. Compressor does not run during defrosting.
3.
Compressor does not run because low temperature is detected if freezer sensor is not connected.
Start
Reference 6
(Page. 40)
N
Replace MICOM and PCB
N
Replace IC07
N
Replace relay
5 minutes after
compressor off?
Y
Is compressor
operated by forse?
N
Reference 7
MICOM pin24
output is “HIGH ”?
Y
IC07 pin10 output
is “LOW ”?
Y
Comp relay is OK?
Y
N
Y
(Page. 41)
Check it after 5 minutes
Freezer sensor is
OK?
Y
Main PCB temperature
detector is OK?
Y
Check wiring
Reference 2
(Page. 38)
N
Replace sensor
N
Check detector & replace PCB
Connector CON 8, 10
N
contects are OK?
Y
N
Check connector
Comp ass ’y is OK?
Y
Replace comp
Check wires connection
Samsung Electronics 29
3) No defrosting
Precautions
1. Even though both F·R-defrost sensors short-circuit, normal operation continues without defrosting.(Refer to self-diagnosis function)
2. Even though the temperature fuse is off, there is no heating but defrosting natural temperature increase comp off-time takes longer.
3. Even though both F·R-defrost sensor are open, heating does not end and comp-off maintains with temperature fuse short-circuited.(Refer to self-diagnosis function)
Start
Y
A
R Defrost H #14 F Defrost H #15
R Defrost H #18 F Defrost H #19
R Defrost H RY01 F Defrost H RY09
Does defrosting
start if the forced defrost
key is pressed?
Y
Is power supplied to
defrost heater?
N
Are MICOM pin 14, 15
“HIGH”?
Y
Are IC 06 pin 17, 18
“LOW”?
Y
Defrost heater
relay is OK?
Reference 2
(Page. 38)
Connector CON C8, 09, 10
Evaparator temp. fuse
short-circuited?
Defrost P-cord short-
Y
are OK?
Y
Y
circuited?
N
N
Reference7 (Page. 41) Measure resistance of defrost sensor
N
N
N
N
N
N
Does the defrost-sensor
register –5˚C?
Y
Forced starting
Replace MICOM & PCB
Replace IC06
Replace relay
Replace CON
Replace temperature fuse
Replace EVAP ass’y
Check wire connection
30 Samsung Electronics