Adjustment
5-2-3. Adjustment
1. PD
1) TPL5-PD & OSC mode
2) - Connect the probe of oscilloscope to TPL5-PD.
- Press the UP/DOWN button or the number buttons so that the A is
2.0µs ± 0.2µs (when NTSC).
3) Using the UPDATE button, store the adjusted value in the EEPROM.
* Using OSC or CSHD, adjust the trigger.
2. BRIGHTNESS
1) TPL06-VG & RGB-AMP mode
2) - Connect the probe of oscilloscope to TPL06-VG.
- Press the UP/DOWN button or the number buttons so that the B
level (between blacks) is 3.5 ± 0.1Vp-p.
3) Using the UPDATE button, store the adjusted value in the EEPROM.
* Using FRP(or use No. 2 - 7 alignment wave form in common), adjust
the trigger.
3. CONTRAST
1) TPL06-VG & CONTRAST mode
2) - Connect probe of oscilloscope to TPL06-VG.
- Press the UP/DOWN button or the number buttons so that the C
level (between black and white) is 3.0 ± 0.1Vp-p.
3) Using the UPDATE button, store the adjusted value in the EEPROM.
4. R-BRIGHT
1) TPL04-VR & R-BRT mode (Bright wave form)
2) - Connect the probe of oscilloscope to TPL04-VR.
- Press the UP/DOWN button or the number buttons so that the B
level (between pedestals) is 3.5 ± 0.1Vp-p.
3) Using the UPDATE button, store the adjusted value in the EEPROM.
5. R-CONTRAST
1) TPL04VR & R-CONT mode (Contrast wave form)
2) - Connect the probe of oscilloscope to TPL04-VR.
- Press the UP/DOWN button or the number buttons so that the C
level is 3.0 ± 0.1Vp-p.
3) Using the UPDATE button, store the adjusted value in the EEPROM.
6. B-BRIGHT
1) TPL05-VB & B-BRT mode (Bright wave form)
2) - Connect the probe of oscilloscope to TPL05-VB.
- Press the UP/DOWN button or the number buttons so that the B
level is 3.5 ± 0.1Vp-p.
3) Using the UPDATE button, store the adjusted value in the EEPROM.