When you disassemble and reassemble components, you must use extreme caution.
The close proximity of cables to moving parts makes proper routing a must. If components are removed, any
cables disturbed by the procedure must be restored as close as possible to their original positions. Before
removing any component from the machine, note the cable routing that will be affected.
Whenever servicing the machine, you must perform as follows:
1. Check to verify that documents are not stored in memory.
2. Unplug the power cord.
3. Use a flat and clean surface.
4. Replace only with authorized components.
5. Do not force to remove or planten plastic-material components.
6. Make sure all components are in their proper position.
4-2 Rear Cover
1. Remo ve the six screws securing the Rear Cover . 2. Separate the rear cover from the base frame
and Scanner Ass'y.
4-1
Disassembly and Reassembly
4-3 Scanner Ass'y
1. Before you remove the Scanner Ass'y, you
should remove:
- Rear Cover (see page 4-1)
2. Remove the six screws and take out the Shield
Main Upper.Unplug the one connector and CCD
cable.
Shield Main Upper
4. Open the Side Cover assembly first to open the
Front cover. In the other words, close the front
cover first to assembly it.
.
Side Cover Ass’y
2
1
Front Cover
Notice :
You should connector remove the CCD cab le v ertically to
avoid the CCD cable pin damage.
3. Remove the three screws, as shown below.
5. Remove two screws.
4-2
Disassembly and Reassembly
6. Pull up the Scanner Ass'y in the direction of
arrow.
7. Remove the connector from the Platen Ass'y.
9. Remove the three screws securing the Platen
Ass'y.
10. Pull the OPE Ass'y and unplug the one connector.
8. Open the ADF Ass’y in the direction of arrow.
Pull the ADF Ass'y upward and remove it.
11. Remove the five screws securing the Platen Ass'y.
4-3
Disassembly and Reassembly
12. Unlatch the Scan Upper Ass'y securing the
glass and remove it.
Notice :
When foreign material enters into the Scan Assy, it may
cause problems in product performance and deteriorate
scan image. Therefore, you should always dismantle or
assemble it at a clean place.
14. Remove the four screws and Channel Base
Frame.
Channel Base Frame
13. Remove the two scews and pull the Dummy
Upper Ass’y.
Dummy Upper Ass’y
15. Remove the five screws and Dummy ScanLower.
Cover Dummy Lower
Cover Scan Lower
4-4
Disassembly and Reassembly
16. Remove the CCD cable.
18. Remove three screws and take out the Motor
Bracket.
17. Pull up the Shaft CCD and tak e out the Scanner
Module.
Shaft CCD
Pully
Scanner Module
Belt
19. Remove the OPE Harness from the Platen
PBA. Remove two screws and take out the
Platen PBA.
Platen PBA
OPE Harness
4-5
Disassembly and Reassembly
4-4 ADF Ass'y
1. Before you remove the ADF Ass'y, you should
remove:
- Rear Cover (see page 4-1)
- Scanner Ass'y (see page 4-2)
2. Remove the five screws from the Platen Cover.
Platen Cover Ass’y
4. Pull the ADF Ass'y upward and remove it.
Platen Cover Ass’y
3. Open the Cover open and pull the Cover Side L
and Cover Side R and unlatch the Side Cover L
by pushing the part hooked the Platen Cover
using a sharp tool.
Side Cover R
Side Cover L
Cover Open
Platen Cover
Ass’y
5. Tack out he Open Cover.
4-6
Disassembly and Reassembly
6. Take out the Pick-up Ass’y.
Remove the four screws and the ADF Upper.
Pick-up Ass’y
ADF Upper
7. Remove three screws and take out the ADF
Motor ass'y.
4-7