SAMSUNG SAM 18650 30Q Datasheet

-SAMSUNG SDI Confidential Proprietary –
Spec. No.
INR18650-30Q
Version No.
Wanmook, Lim
SPECIFICATION OF PRODUCT
Lithium-ion rechargeable cell for power tools
Model name : INR18650-30Q
Samsung SDI Co., Ltd.
Energy Business Division
Feb, 2015
Spec. No.
INR18650-30Q
Version No.
1.0
Wanmook, Lim
- 1/20 -
Revision
No.
Date(‘yr-m-d)
Page
Item
Description
Changes
/ Author
v1.0
‘15-02-02
First Edition
Wan-Mook Lim
Revision history
-SAMSUNG SDI Confidential Proprietary –
-SAMSUNG SDI Confidential Proprietary –
Spec. No.
INR18650-30Q
Version No.
1.0
Wanmook, Lim
- 2/20 -
Item
Specification
3.1 Minimum discharge capacity
2,950mAh Charge: 1.50A, 4.20V,CCCV 150mA cut-off, Discharge: 0.2C, 2.5V discharge cut-off
3.2 Nominal voltage
3.6V
3.3 Standard charge
CCCV, 1.50A, 4.20 ± 0.05 V, 150mA cut-off
3.4 Rated charge
CCCV, 4A, 4.20 ± 0.05 V, 100mA cut-off
3.6 Charging time
Standard charge : 180min / 150mA cut-off Rated charge: 70min (at 25) / 100mA cut-off
3.7 Max. continuous discharge (Continuous)
15A(at 25℃), 60% at 250 cycle
3.8 Discharge cut-off voltage
End of discharge
2.5V
3.9 Cell weight
48.0g max
3.10 Cell dimension
Height : Max 65.0mm Diameter : Max 18.4mm
3.11 Operating temperature
(surface temperature)
Charge : 0 to 50 (recommended recharge release < 45) Discharge: -20 to 75 (recommended re-discharge release < 60)
3.12 Storage temperature
(Recovery 90% after storage)
1.5 year -30~25(1*)
3 months -30~45(1*) 1 month -30~60(1*)
1.0. Scope
This product specification has been prepared to specify the rechargeable lithium-ion cell ('cell') to be supplied to the customer by Samsung SDI Co., Ltd.
2.0. Description and model
2.1 Description lithium-ion rechargeable cell
2.2 Model name INR18650-30Q
3.0. Nominal specifications
Note (1): If the cell is kept as ex-factory status (40±5% SOC, 25), the capacity recovery rate is more than 90% of 10A discharge capacity
100% is 2,900mAh at 23 with SOC 100% after formation.
-SAMSUNG SDI Confidential Proprietary –
Spec. No.
INR18650-30Q
Version No.
1.0
Wanmook, Lim
- 3/20 -
4.0 Outline dimensions See the attachment (Fig. 1)
5.0. Appearance
There shall be no such defects as scratch, rust, discoloration, leakage which may adversely affect commercial value of the cell.
6.0. Standard test conditions
6.1 Environmental conditions Unless otherwise specified, all tests stated in this specification are conducted at
temperature 23±3°and humidity under 65%.
6.2 Measuring equipment (1) Amp-meter and volt-meter The amp-meter and volt-meter should have an accuracy of the grade 0.5mA and
mV or higher. (2) Slide caliper The slide caliper should have 0.01 mm scale. (3) Impedance meter The impedance meter with AC 1kHz should be used.
7.0. Characteristics
7.1 Standard charge
This "Standard charge" means charging the cell CCCV with charge current 0.5CmA
(1,500mA), constant voltage 4.2V and 150mA cut-off in CV mode at 23 for capacity. .
7.2 Rated charge Rated charge means charging the cell CCCV with charge current 4A and 100mA cut-off at 23
7.3 Standard discharge capacity The standard discharge capacity is the initial discharge capacity of the cell, which is
measured with discharge current of 600mA(0.2C) with 2.5V cut-off at 23 within 1hour
after the standard charge. Nominal discharge capacity ≥ 2,950mAh Which complying to the minimum capacity of IEC61960 standard.
7.4 Rated discharge capacity The rated discharge is the discharge capacity of the cell, which is measured with discharge current of 10A with 2.5V cut-off at 23 within 1hour after the rated charge.
Standard rated discharge capacity ≥ 2,900mAh
7.5 Initial internal impedance Initial internal impedance measured at AC 1kHz after standard charge
Initial internal impedance ≤ 26mΩ
-SAMSUNG SDI Confidential Proprietary –
Spec. No.
INR18650-30Q
Version No.
1.0
Wanmook, Lim
- 4/20 -
Discharge temperature
-20
-10
0
23
60
60%
75%
80%
100%
95%
Charge temperature
Discharge temperature
0
5
23
45
50
23
Relative capacity
80%
90%
100%
95%
95%
Charge condition
Current
Standard 1.5A
Maximum rapid charge 4A
Cut-off
150mA
100mA
Relative
Capacity
100%
100%
7.6 Temperature dependence of discharge capacity
Capacity comparison at each temperature, measured with discharge
constant current 10A and 2.5V cut-off after the rated charge is as follows.
Note: If charge temperature and discharge temperature is not the same, the interval for temperature change is 3 hours. Percentage index of the discharge at 23 at 10A (=2,900mAh) is 100%.
7.7 Temperature dependence of charge capacity
Capacity comparison at each temperature, measured with discharge constant current
10A and 2.5V cut-off after the rated charge is as follows.
Note: If charge temperature and discharge temperature is not the same, the interval for temperature change is 3 hours.
Percentage index of the discharge at 23 at 10A (=2,900mAh) is 100%.
7.8 Charge rate capabilities Discharge capacity is measured with constant current 10A and 2.5V cut-off after the cell is charged with 4.2V as follows.
Note: Percentage index of the discharge at 23 at 10A (=2,900mAh) is 100%.
-SAMSUNG SDI Confidential Proprietary –
Spec. No.
INR18650-30Q
Version No.
1.0
Wanmook, Lim
- 5/20 -
Discharge condition
Current
0.6A
5A
10A
15A
20A
Relative
Capacity
100%
97%
100%
97%
95%
7.9 Discharge rate capabilities Discharge capacity is measured with the various currents in under table and 2.5V cut-off after the rated charge.
Percentage index of the discharge at 25 at 10A (=2,900mAh) is 100%.
7.10 Cycle life With standard charge and maximum continuous discharge. Capacity after 250cycles,
Capacity 1,800mAh (60% of the nominal capacity at 23)
7.11 Storage characteristics Standard rated discharge capacity after storage for 1 month at 60 from the standard
charged state is 90% of the initial 10A discharge capacity at 23
7.12 Status of the cell as of ex-factory
The cell should be shipped in 3.620V to 3.690V charging voltage range.
8.0. Mechanical Characteristics
8.1 Drop test Test method: Each fully charged cell or battery is dropped three times from a height of
1.0 m onto a concrete floor. The cells or batteries are dropped so as to obtain impacts in random orientations. After the test, the sample shall be put on rest for a minimum of one hour and then a visual inspection shall be performed.
Criteria: No fire, no explosion. Drop test shall be performed with the IEC62133 standard
8.2 Vibration test Test method: As to the UN transportation regulation(UN38.3), for each axis (X and Y axis with cylindrical cells) 7Hz200Hz7Hz for 15min, repetition 12 times totally 3hours, the acceleration 1g during 7 to 18Hz and 8g (amplitude 1.6mm) up to 200Hz.
Criteria: No leakage, with less than 10% of OCV drop
Vibration test shall be performed with the UN38.3 standard
Loading...