Charge : 0 to 50℃
(recommended recharge release < 45℃)
Discharge: -20 to 75℃
(recommended re-discharge release < 60℃)
3.12 Storage temperature
(Recovery 90% after storage)
1.5 year -30~25℃(1*)
3 months -30~45℃(1*)
1 month -30~60℃(1*)
1.0. Scope
This product specification has been prepared to specify the rechargeable lithium-ion cell
('cell') to be supplied to the customer by Samsung SDI Co., Ltd.
2.0. Description and model
2.1 Description lithium-ion rechargeable cell
2.2 Model name INR18650-30Q
3.0. Nominal specifications
Note (1): If the cell is kept as ex-factory status (40±5% SOC, 25℃),
the capacity recovery rate is more than 90% of 10A discharge capacity
100% is 2,900mAh at 23℃ with SOC 100% after formation.
-SAMSUNG SDI Confidential Proprietary –
Spec. No.
INR18650-30Q
Version No.
1.0
Wanmook, Lim
- 3/20 -
4.0 Outline dimensions
See the attachment (Fig. 1)
5.0. Appearance
There shall be no such defects as scratch, rust, discoloration, leakage which
may adversely affect commercial value of the cell.
6.0. Standard test conditions
6.1 Environmental conditions
Unless otherwise specified, all tests stated in this specification are conducted at
temperature 23±3°and humidity under 65%.
6.2 Measuring equipment
(1) Amp-meter and volt-meter
The amp-meter and volt-meter should have an accuracy of the grade 0.5mA and
mV or higher.
(2) Slide caliper
The slide caliper should have 0.01 mm scale.
(3) Impedance meter
The impedance meter with AC 1kHz should be used.
7.0. Characteristics
7.1 Standard charge
This "Standard charge" means charging the cell CCCV with charge current 0.5CmA
(1,500mA), constant voltage 4.2V and 150mA cut-off in CV mode at 23℃ for capacity.
.
7.2 Rated charge
Rated charge means charging the cell CCCV with charge current 4A and 100mA cut-off
at 23℃
7.3 Standard discharge capacity
The standard discharge capacity is the initial discharge capacity of the cell, which is
measured with discharge current of 600mA(0.2C) with 2.5V cut-off at 23℃ within 1hour
after the standard charge.
Nominal discharge capacity ≥ 2,950mAh
Which complying to the minimum capacity of IEC61960 standard.
7.4 Rated discharge capacity
The rated discharge is the discharge capacity of the cell, which is measured
with discharge current of 10A with 2.5V cut-off at 23℃ within 1hour after the rated
charge.
Standard rated discharge capacity ≥ 2,900mAh
7.5 Initial internal impedance
Initial internal impedance measured at AC 1kHz after standard charge
Initial internal impedance ≤ 26mΩ
-SAMSUNG SDI Confidential Proprietary –
Spec. No.
INR18650-30Q
Version No.
1.0
Wanmook, Lim
- 4/20 -
Discharge temperature
-20℃
-10℃
0℃
23℃
60℃
60%
75%
80%
100%
95%
Charge temperature
Discharge temperature
0℃
5℃
23℃
45℃
50℃
23℃
Relative capacity
80%
90%
100%
95%
95%
Charge condition
Current
Standard 1.5A
Maximum rapid charge 4A
Cut-off
150mA
100mA
Relative
Capacity
100%
100%
7.6 Temperature dependence of discharge capacity
Capacity comparison at each temperature, measured with discharge
constant current 10A and 2.5V cut-off after the rated charge is
as follows.
Note: If charge temperature and discharge temperature is not the same,
the interval for temperature change is 3 hours.
Percentage index of the discharge at 23℃ at 10A (=2,900mAh) is 100%.
7.7 Temperature dependence of charge capacity
Capacity comparison at each temperature, measured with discharge constant current
10A and 2.5V cut-off after the rated charge is as follows.
Note: If charge temperature and discharge temperature is not the same,
the interval for temperature change is 3 hours.
Percentage index of the discharge at 23℃ at 10A (=2,900mAh) is 100%.
7.8 Charge rate capabilities
Discharge capacity is measured with constant current 10A and 2.5V cut-off
after the cell is charged with 4.2V as follows.
Note: Percentage index of the discharge at 23℃ at 10A (=2,900mAh) is 100%.
-SAMSUNG SDI Confidential Proprietary –
Spec. No.
INR18650-30Q
Version No.
1.0
Wanmook, Lim
- 5/20 -
Discharge condition
Current
0.6A
5A
10A
15A
20A
Relative
Capacity
100%
97%
100%
97%
95%
7.9 Discharge rate capabilities
Discharge capacity is measured with the various currents in under table and 2.5V
cut-off after the rated charge.
Percentage index of the discharge at 25℃ at 10A (=2,900mAh) is 100%.
7.10 Cycle life
With standard charge and maximum continuous discharge.
Capacity after 250cycles,
Capacity ≥ 1,800mAh (60% of the nominal capacity at 23℃)
7.11 Storage characteristics
Standard rated discharge capacity after storage for 1 month at 60℃ from the standard
charged state is ≥ 90% of the initial 10A discharge capacity at 23℃
7.12 Status of the cell as of ex-factory
The cell should be shipped in 3.620V to 3.690V charging voltage range.
8.0. Mechanical Characteristics
8.1 Drop test
Test method: Each fully charged cell or battery is dropped three times from a height of
1.0 m onto a concrete floor. The cells or batteries are dropped so as to
obtain impacts in random orientations. After the test, the sample shall be
put on rest for a minimum of one hour and then a visual inspection shall be
performed.
Criteria: No fire, no explosion.
Drop test shall be performed with the IEC62133 standard
8.2 Vibration test
Test method: As to the UN transportation regulation(UN38.3), for each axis (X and Y
axis with cylindrical cells) 7Hz→200Hz→7Hz for 15min, repetition 12 times totally
3hours, the acceleration 1g during 7 to 18Hz and 8g (amplitude 1.6mm) up to 200Hz.
Criteria: No leakage, with less than 10% of OCV drop
Vibration test shall be performed with the UN38.3 standard