Samsung SR-A20M, SR-26NME, SR-25NMB, SR-24WMF, SR-24WME User Manual

...
5 (1)

Model: SR-21NME/21WME

SR-24NME/24WME

REFRIGERATOR

 

CONTENTS

1.Safety precautions and 2.Product specifications 3.Electrical part specifications & 4.Product dimension

5. Identifying and disassembling 6.Schematic diagram of coolant 7. Circuit diagram

8. Packing dimensin

9. Schematic siagram of cold air

10. Troubleshooting method

11. Exploded view & part list

1.Safety precautions and warnings

Read all instructions before using this appliance in risk of accident order to avoid or property damage.

Warning/Caution

This symbol is intended to

Warning alert the user to the posslble death or injury.

This symbol is intended to Caution alert the user to the posslble

injury or damage

Description of symbols

In dicates prohibition

Do not disassemble

Do not contant

Adhere the instruction strictly

Unplug from the electrical outlet

Earth the appliance to avoid the risk of an electric shock

Warning

Do not plug multiple electyical

Do not attempt to make repairs

Make sure the power cord is not

appliances into the same outlet.

yourself

crushed or damaged.

●This may cause abnormal heating or

●This could lead to fire hazard or

●Repair immediately all power cords or

fire hazard.

abnormal operation causing severe

outlets that have become frayed or

 

personal injury.

otherwise damaged.

Prohibition

Do not

 

disassemble

 

 

 

Check the operating environment.

Do not attempt to make repairs

Make sure the power cord is not

●Do not install the refrigerator in a

yourself.

crushed or damaged.

humid(with condensation)location or

●This could lead to fire hazard or

●Repair immediately all power cords

on an unstable surface.

abnormal operation causing severe

or outlets that have become frayed

 

personal injury.

or otherwise damaged.

Earth

Unplug

2

SR-21/24 NME(WME)

Caution

Do not store bottled food or

Do not store food in an unstable

Do not store anything other

drinks in the freezing

manner.

than food in the refrigerator.

compartment.

●Opening the door may trigger loose

●Medical supplies which need to be

●Bottles may explode causing

items to slip and cause injury.

under strict not be stored in the

personal injury.

 

refrigerator.

Prohibition

Prohibition

Prohibition

Do not put anything on top of

When replacing electric

When servicing the refrigera-tor,

the refrigerator.

comporents, be sure to use rates

completely remove dust or

● Opening or closing the door may

comporents.

foreign substances from the

trigger loose items to slip and

●Check the model, rated voltage, rated

housing,electric conne-ctions

cause injury.

current, operating temperature etc. of

and etc.

 

the component.

●This can proect against the risk of fire

 

 

hazard caused by tracking and short

 

 

circuit.

 

Reted

 

 

components

 

Prohibition

When servicing the refrigerator, completely remove dust or foreign substances from the housing, electric connections and etc.

●This can protect against the risk of fire hazard caused by tracking and short circuit.

After serving the refrigerator, be sure to check the components are reassembled in a correct manner.

●The serviced unit should be reassembled and returned to its original assembly state.

Check the electrical parts for the trace of moisture penetration.

●When the trace of moisture pentration is detected, replace the part or dry insulation tapping.

SR-21/24 NME(WME)

3

2.Product Specifcations

 

 

 

ITEM

 

STANDARD

 

 

 

 

 

 

 

 

 

Model name

SR-21NME/24WME

SR-24NME,24WME

 

 

 

Type

2-Door Freezer/Refrigerator

 

 

 

 

 

 

 

 

 

 

Power source

AC 115V/60HZ, 127V/60Hz

 

 

220V/50~60Hz, 230~240V/50Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Freezer

52(1.8)

 

52(1.8)

 

Net capacity

 

 

 

 

 

 

 

 

 

Refrigerator

133(4.7)

 

133(4.7)

 

(it/cu.ft)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total

182(6.5)

 

182(6.5)

 

 

 

 

 

 

 

 

 

 

Net dimension

 

 

Width

 

545

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(mm)

 

 

 

Depth

 

589

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

1453

 

1553

 

 

 

 

 

 

 

 

 

 

 

 

Net weight (kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant

 

D-134a(130gr)

 

 

 

Temperature control

Dial(Thermostat)

 

 

 

 

 

 

 

 

 

 

 

 

Defrosting

Automatic(Start-Finish by Timer)

 

 

 

 

 

 

 

 

 

 

Foam insulation

Cabinet

 

R-141b

 

 

 

 

 

 

Door

 

R-141b

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Liner / Door panel

 

ABS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Door

2 Guard-freezer

 

2 Guard-freezer

 

 

 

 

 

1 Guard-egg

 

1 Guard-egg

 

 

 

 

 

 

 

 

 

 

 

 

storage

1 Guard-variety

 

1 Guard-variety

 

 

 

 

 

 

2 Guard-bottle

 

2 Guard-bottle

 

 

 

 

 

 

 

 

 

 

Accessory parts

 

1 Base-tray ice(H)

 

2 Shelf-refrigerator(H)

 

 

1 Case-tray ice, assy(H)

1 Tray-chilled room(H)

 

 

 

 

 

inside

 

 

 

 

 

1 Tray-ice cube

 

1 Cover-chilled room(H)

 

 

 

 

 

 

 

 

 

 

 

 

storage

1 Shelf0freezer, sub(H)

1 Shelf-freezer wire(L)

 

 

 

 

 

 

1 Cover-vegetable

 

1 Tray-ice,b(L)

 

 

 

 

 

 

1 Tray-vegetable

 

1 Shelf-ref wire(L)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

interior Lamp(H/M)

 

1(Refrigerator)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Angle adjustment

 

2Legs(Front)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

SR-21/24 NME(WME)

3. Electrical part specification & standard

 

 

ITEM

 

 

STANDARD

 

 

 

 

 

 

 

 

 

 

 

Model

SR-21NME, 21WME / SR-24NME, 24WME

 

 

 

 

 

 

 

 

Power source

115V/60HZ

 

220V/50~60HZ

 

230~240V/50HZ

 

 

 

 

 

 

 

 

 

 

 

Model

SD152C-L1W2

SD162H-L1U2

SD162Q-L1U2

 

 

 

 

 

 

 

 

 

Compressor

 

Starting type

C.S.R

 

R.S.C.R

 

 

 

 

 

 

 

 

 

 

Oil charge

 

FREOL α-15c / 200cc

 

Evaporator

 

 

Split fin type

 

 

Condenser

Forced & natual convection

 

 

Dryer

 

 

Molecular sieve

 

 

 

 

 

 

 

 

Capillary tube

 

 

I.D 0.75 x 3400 (mm)

Thermostat

 

Freezer

 

8032

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerator

 

 

D705-E9C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bimetal

Type

 

AC250V / 5A

 

 

 

 

 

 

 

 

 

Defrost-thermo

(ON/OFF)

Oper. temp

 

ON:-5±3 /OFF:12±3

 

 

 

 

 

 

 

 

 

 

Thermal fuse

Regularity

 

AC 250V / 10A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Oper. temp.

 

72±4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

TMDE714F1

 

TMD706SC1

Defrost-timer

 

Cycle

 

 

6Hr 35min

 

 

 

 

 

 

 

 

 

 

 

 

Time

 

 

13min 40s

 

 

 

 

 

 

 

 

 

Starting-relay

 

Model

912X32E100MQ16APE3(60Hz)

912X32E100MQ16APE2

 

 

 

 

 

 

 

 

 

 

Resistance

40Ω±20%

 

 

 

33Ω±20%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

4TM427

 

4TM265

 

 

4TM222

 

 

 

 

 

 

 

 

 

Over load

 

PHBYY-53

 

PHBYY-53

 

 

 

PHBYY-53

 

 

 

 

 

protector

 

 

 

 

 

 

 

 

 

 

Close temp

 

 

61±9

 

 

 

 

 

 

 

 

Open temp

 

 

125±5

 

Capacitor

 

Running

125 / 100VAC

 

3.5 /350VAC

 

 

 

 

 

 

 

 

 

 

Starting

8 / 250VAC

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor-fan

IS3210SMF6D

 

IS3210SNF7A

 

 

 

 

 

 

 

Heater-defrost

130W/93Ω

 

130W406.9Ω

 

130W443Ω

 

 

Lamp

110V / 15W

 

220V/15W

 

240V/15W

 

Door-switch

 

SSD-5 250V/0.5A

 

 

 

 

 

 

 

 

 

 

Earth screw

BSBN(Brass screw)

 

 

 

 

 

 

 

 

 

 

 

SR-21/24 NME(WME)

5

4.Product Dimension

545.0

1071.0

366.5

77.5

 

 

545.0

 

 

 

 

 

 

500.0

A 9.5

B

59.5

51.0

MODEL

A

B

Remark

 

 

 

 

SR-21NME, 21WME

1453

874.5

 

 

 

 

 

SR-24NME, 24WME

1553

974.5

 

 

 

 

 

6

SR-21/24 NME(WME)

Samsung SR-A20M, SR-26NME, SR-25NMB, SR-24WMF, SR-24WME User Manual

5.Identifying and dissembling the parts

To remove shelves in the freezing compartment

●First remove the icemaking molds. Tilt the shell up at front, then lift it up pull it out of the tracks.

To remove shelves in the refrigerating compartment

●Hold the shelf by the front and pull it forward of the rack.

To remove shelves in the chilled compartment

●Lift up the cover, push the cover to the right until the mounting hook disengages, then disengage the other mounting hook and pull out the cover.

●Pull the shelf forward until it stops. Then lift it up and pull it out.

To remove storage drawers and covers

●Lift up to remove the cover. Pull the drawer out then lifting it up.

To remove door bins

●While pushing the bin to the left, left it up to disengage.

 

 

 

 

 

 

 

SR-21/24 NME(WME)

7

6. Schematic diagram of coolant circulation

COMPRESSOR → CLUSTER PIPE → HOT PIPE → DRYER → CAPILLARY TUBE

→ EVAPORATOR → ACCUMULATOR → SUCTION PIPE → COMPRESSOR

PIPE-CLUSTER,B

ACCUMULATORB

EVAPORATOR

HOT-PIPE

PIPE-CLUSTER,A

SUCTION

PIPEA

CAPILLARY TUBE

DRYERA

COMPRESSOR

8

SR-21/24 NME(WME)

7.Circuit diagram

7-1. SR-21/24NME

 

YEL

 

 

 

 

 

GRY

L

 

 

 

F-THERMOSTAT

 

 

 

 

 

 

 

E

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

3

 

1 WHT

 

 

 

L R/LAMP

 

M

 

 

 

W/BLK

 

 

 

BRN

BRN

RED

PNK

 

 

4

2

RED

 

 

BIMETAL

THERMO FUSE

DEFROST

 

 

 

 

 

DEFROST THERMO

 

 

 

TIMER

HEATER

 

S/BLU

 

 

F.M

 

ORG

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAN MOTOR

 

 

DOOR-S/W

 

S/BLU

 

 

 

M

 

2

1

RED

 

2

5

 

 

 

 

 

C

3

OVERLOAD

 

 

 

 

 

 

 

S/BLU

BLU

3

6

S

COMPRESSOR

 

PROTECTOR

 

 

 

RUNNING

 

P.T.C RELAY

 

 

 

 

 

CONDENSER

 

 

 

 

 

GRY - GRAY

RED - RED BRN - BROWN YEL - YELLOW

S/BLU - SKY BLUE PNK - PINK

BLK - BLACK

WHT - WHITE

BLU - BLUE

7-2. SR-21/24WME

 

YEL

 

 

 

 

 

 

GRY

L

 

 

 

F-THERMOSTAT

 

 

 

 

 

 

 

POWER-PCB

E

N

 

 

 

WATER-DISPENSER

 

 

 

 

 

 

BLK

GRY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

MICRD-S/W

 

RED

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MOTOR-PLMP

 

 

 

 

3

 

1 WHT

 

 

 

 

L R/LAMP

 

M

 

 

 

 

W/BLK

 

 

 

BRN

BRN

RED

PNK

 

 

 

4

2

 

RED

 

 

BIMETAL

THERMO FUSE

DEFROST

 

 

 

 

 

 

 

DEFROST THERMO

 

 

 

 

TIMER

HEATER

 

S/BLU

 

 

F.M

 

ORG

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAN MOTOR

 

 

DOOR-S/W

 

S/BLU

 

 

 

M

 

2

1

RED

 

2

5

 

 

 

 

 

C

3

OVERLOAD

 

 

 

 

 

 

 

S/BLU

BLU

3

6

S

COMPRESSOR

 

PROTECTOR

 

 

 

RUNNING

 

P.T.C RELAY

 

 

 

 

 

CONDENSER

 

 

 

 

 

GRY - GRAY

RED - RED BRN - BROWN YEL - YELLOW

S/BLU - SKY BLUE PNK - PINK

BLK - BLACK

WHT - WHITE

BLU - BLUE

SR-21/24 NME(WME)

9

Loading...
+ 20 hidden pages