Intruder Detector using a radar principle
URX-P01
User’s Manual
Written By
Device Development Group
S-1 CORPORATION
168, S1 BUILDING,
SOONHWA-DONG, JOONG-GU,
SEOUL, KOREA
Tel: +82 1588 3112
Fax: +82 2 2131 8869
Website: www.s1.co.kr
Revised: May 2015
CAUTION!!
• This equipment may only be operated Indoors.
• Do not use to Outdoors.
• Do not intentionally install aimed at windows or outside opening doors.

Table of Contents
Introduction & Information ………………………...............……….1
Features of the UWB Sensor....……………………………………...2
Coverage of the UWB Sensor.……………………………………….3
UWB Sensor Specifications………………………………………….4
Installation………………………………………………………………5
Operational precautions……………………………………………...7

INTRODUCTION & INFORMATION
Introduction
The UWB(Ultra Wide Band) sensors refers to a kind of radar technology that was traditionally
used in military applications. When used as a security means, it’s low power, wide band
characteristics often causes frequent false alarms. Overcoming such limitations with its
excellence in technology, S1 showcases the first ever UWB-based security sensor in the world.
Its radar-based principle makes it inherently immune to heat source-induced false alarms and
enables high level of sensitivity to the movement of heat-insulated intruders. Coverage can be
flexibly adjusted to enable its deployment in various environments.
This document describes the features and the specifications of the UWB sensor, important
regulatory information concerning its use, and details on how to diagnose potential problems.
Information to the User
The UWB sensor is an ultra-wideband(UWB) wireless device certified under FCC Part 15.517.
It’s use is subject to technical requirements for indoor UWB systems, in particular the stipulation
that the devices must only be used indoors. Users should note carefully the following
information:
• CAUTION: This equipment may only be operated indoors. Operation outdoors is in
violation of 47 U.S.C. 301 and could subject the operator to serious penalties.
• This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
Users should also carefully note the following information:
• CAUTION: Any changes or modifications made to the “UWB Sensor” which are not
expressly approved by the “S-1” could void the user’s authority to operate the equipment.
• NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications, However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver
Is connected.
- Consult the dealer or an experienced radio/TV technician for help.
- 1- UWB Intrusion Detection Sensor – URX-P01

FEATURES OF THE UWB SENSOR
Features of the UWB Sensor
The diagram below shows several important features of the UWB Sensor:
UWB
Antenna
GB-41
(Bracket)
Lens
Terminal
(Power, COM,Tamper)
Rotary Switch
LED
[SET]
Magnetic Switch
Point
Label
(System)
[TOP] [BOTTOM]
- 2- UWB Intrusion Detection Sensor – URX-P01

COVERAGE OF THE UWB SENSOR
Coverage of the UWB Sensor
Maximum detection area of the sensor is as follows:
Horizontal View
Vertical View
0m
1.8m
2.4m
3.0m
0m(0ft)
Note
- Installer is to walk into the pattern or may walk perpendicular to the pattern to verify the pattern.
-3- UWB Intrusion Detection Sensor – URX-P01
2m(6.5ft)
5m(16.4ft)
10m(32.8ft)
0ft
6ft
8ft
10ft

UWB SENSOR SPECIFICATIONS
Impulse Radio(Ultra Wide Band)
Wide: 8m x 10m(26.24 x 32.80ft), 80˚ Wide
0.3 ~ 1.5m/sec.(1 ~ 5ft/sec.)
Red LED ON (When detecting)
N.C (200VDC 0.1A max.)
Alarm Output Period
12VDC(9.6 ~ 14.4VDC)
Current Consumption
20mA (max.) at 12VDC(9.6 ~ 14.4VDC)
-10℃ ~ +50℃(+14℉ ~ +122℉)
UWB Sensor Specifications
The specification of the sensor refer to the following table:
- 4- UWB Intrusion Detection Sensor – URX-P01

INSTALLATION
1 Step : Using key separate “TOP” and “BOTTOM”
2 Step : Assemble “Bottom” and “GB-41”
3 Step : Connection “Top” and “Wire”
SPARE
TAMPER ALRAM 12VDC
NC C SP NC C (-) (+)
- 5- UWB Intrusion Detection Sensor – URX-P01

INSTALLATION
4 Step : Assemble “Top” and “Bottom”
※Adjustable detection range from 1 to 10 meter by rotary switch
☞ Note that each adjusted range has ±0.5m deviation
Be sure walk test after installation
Note
1. The unit is to be tested at a min once per year.
2. This unit is designed to detect a burglar or an intruder. When an alarm control panel is activated, the
unit detects a burglar or an intruder. It is only a part of a complete system, we cannot responsibility any
damage to change without prior consent of the S-1
※Specifications and design are subject to change without prior notice
- 6- UWB Intrusion Detection Sensor – URX-P01

OPERATIONAL PRECAUTIONS
Operational precautions
• Do not apply voltages higher than the
rated voltage.
AC220V
• When swaying objects(mobiles of metal material),
in the detection area, change the direction or
adjust the detection distance.
• Do not install where dogs and cats.
• Do not install the outdoor.
• Do not install in the swaying wall.
• Do not install the curtain(blind) by the external
wind swaying.
• Do not install near any moving fan.
- 7- UWB Intrusion Detection Sensor – URX-P01