Samsung RL-33EBMS TROUBLE DIAGNOSIS AND REPAIR SOLUTIONS

7. TROUBLE DIAGNOSIS & REPAIR SOLUTIONS
Mainboard inspection method
At the self-diagnosis stage, you must cut off and reconnect to the power for inspection. The self-diagnosis codes are listed below
self-diagnosis codes:
NO
Refrigerating sensor
Main evaporator sensor
Freeze sensor
External sensor
Magnetic switch
ITEM
C C
DISPLAY
TROUBLE Open circuit short circuit Open circuit short circuit Open circuit short circuit Open circuit short circuit
Air door relay failure, or motor, air door magnetic spring switch or magnet trouble
Door switch
Refrigerating sensor
Refrigerating compartment
Freeze compartment
COMMENTS Test temp. lower than -50 Test temp. higher than +85 Test temp. lower than -50 Test temp. higher than +85 Test temp. lower than -50 Test temp. higher than +85 Test temp. lower than -50 Test temp. higher than +85 Magnetic spring switch ON/OFF is unable to be detected after 1 minute's run
Sensor resistance and core chip voltage and temp.
Resistance ResistanceResistance Resistance
Temp Temp
Voltage VoltageVoltage Voltage
Temp Temp
21
Primary Inspection
1. Prior to trouble settlement, check if the power socket is electrified and the connecting power
supply spec. is normal.
2. Check if the power botton on display is pressed or not.
3. If other troubles are found, please refer to the remarks on the next page to make an inspection.
Start
Test the 7812 output woltage Test the 7805 output woltage
Power on again
N
Is primary voltage of the
transformer ok ?
Y
Is secondary voltage of
Transformer ok ?
Y
Is display ok ?
Y
Replace the mainboard
subassembly
Y
Normal
N
Check and repair the
wire assembly
N
replace the transformer
N
Repair or replace the display
22