SAMSUNG RCD-590 Service Manual Alignment & Adjustment

1. Alignment and Adjustments
1-1 Tuner
Samsung Electronics 1-1
FM THD Adjustment
Minimum Distortion (Figure 1-1)
SSG FREQ.
Adjustment point (IT1)
98 MHz
FM DETECTOR COIL
FM Stereo Adjustment
L-CH/R-CH : Maximum(Figure 1-3)
SSG FREQ.
Frequency
Adjustment point (ISVR1)
98MHz
98MHz
SEMI-VR(5K)
FM Search Level Adjustment
Adjust ISVR2 so that “TUNED” of LCD is lighted (Figure 1-2)
Figure1-2 FM Auto Search Level Adjustment
Figure1-3 FM Stereo Separation Adjustment
Figure1-1 IF CENTER and THD Adjustment
SSG FREQ.
Adjustment point
(ISVR2)
98 MHz
BEACON SENSITIVITY
SEMI-VR(50K)
FM SSG
FM SSG
75
Dummy
5K
Stereo Modulator (Pilot 10%)
OUT
Oscilloscope
FM antenna
SET
Speaker Terminal
EXT
GND
VTVM
GND
26 dB
FM SSG
Output GND
Speaker Terminal
FM Antenna Terminal
Distortion Meter
Input
SET
Input
output
Oscilloscope
FM IN
FM Antenna
SET
50 k
FREQ:1KHz MOD : 40KHz DEV
1-2 Samsung Electronics
1-1-1 Test Equipment
1-1-2 Pre-Adjustment
1-1-3 AM Adjustment
1. AM Standard Signal Generator (S.S.G) : 400Hz, 30% MOD
2. Oscilloscope
3. VTVM
4. Frequency counter
5. Loop antenna
6. Dummy load (3½)
7. DC voltmeter
1. Check the source voltage
2. Press TUNER/BAND to select the AM(MW) function.
3. Set the EQ/S.BASS control to OFF position.
4. Set the volume control to approximaterly 50mw
Intermediate frequency (IF) adjustment
AM frequency coverage adjustment
AM tracking adjustment
Figure 1-4
Connect DC voltmeter to AM VT(OR10) and GND
1
2
4
5
3
Figure 1-5
Figure 1-5
450 KHz
594 KHz
Figure 1-4
SET
60 cm
AM Signal Generator
Test Loop Antenna
Speaker Terminal
VTVM
IN
OUT
GND
Oscilloscope
AM-ANT
Figure 1-5
SET
AM VT(OR10)
GND
DC Voltmeter
594 KHz
MW-ANT
-
-- -
OCT2
1611KHz
-
-
522 KHz
522 KHz
IT 2
OT 1
1.0V
Maximum output
Maximum output
4.6V
Non Adjust
Remark
FREQ. Setting
Adjust. PointSSG.FREQ.Item
Connection
Alignment and Adjustments
Dummy Load(3½)
1-1-4 MW/LW
Intermediate frequency (IF) adjustment
MW frequency coverage adjustment
MW tracking adjustment
Fig 1-4
1
2
4
5
3
Fig 1-5
594 KHz
594 KHz
MW ANT
COIL
-
OCT2
-
-
LW ANT
COIL
OT1
1.0V(LOW)
Maximum output
Maximum output
Remark
FREQ. Setting
Adjust. Point
SSG.FREQ.
Item
Connection
522 KHz
4.6V(HIGH)
1611 KHz
1404 KHz
­NON Adjust
6
Fig 1-4
-
144 KHz
OT2
0.7V(LOW)
-
290 KHz
OCT4
3.1V(HIGH)
LW frequency coverage adjustment
7
9
8
LW tracking adjustment
Fig 1-5
170KHz
170 KHz
270KHz
-
-
Fig 1-5
450 KHz 522 KHz
IT2
Maximum output
NON Adjust
Loading...
+ 1 hidden pages