Samsung PN50C6500TFXZA Schematic

Page 1
Latest Firmware: Please check Samsung.com for latest update!
2010 PDP Firmware for Valencia 1G (T­VALAUSC, 1035.0)
Firmware for Valencia 1G Model Ver: 1035.0 Folder Name: T-VALAUSC Description: Support Netflix 2.1 and MLB.tv apps. And this firmware prevents below issues:
- 3D picture judders when 'Motion Judder Canceller' is set to 'Smooth' or 'Standard'.
- USB Power Overload' message pops up even USB port is not connected
- HDMI ports recognition error and signal loose
- Plug & Play is displayed whenever turning on
TV.
No Service Bulletins
Please check GSPN for parts update!
Quick Parts List:
HELP: 1-888-751-4086 (Tech Support)
1-866-894-0637 (FE) GSPN
http://gspn3.samsungcsportal.com
PLUS ONE
http://my.plus1solutions.net/clientPortals/samsung
HOT TIPS
-Power On Problems: (pg. 3)
-Video Problems: (pg. 4)
PN50C6500TFXZA
Version
Parts No
Short Description
NZ02
BN44-00333A
SMPS
NZ02
BN94-03316N
Main PCB
NZ02
BN96-12958A
Buffer E
NZ02
BN96-12959A
Buffer F
NZ02
BN96-12960A
X Main
NZ02
BN96-12961A
Buffer X
NZ02
BN96-12962A
Y Main
NZ02
BN96-12963A
Buffer Y
NZ02
BN96-12964A
Logic Main PCB
NZ02
BN96-14336B
Function & IR PCB
NZ02
BN96-12712A
Panel
NZ02
BN63-06481A
Bottom Cover
NZ02
BN96-10689A
Stand Guide Neck
NZ02
BN96-12992C
Front Cover
NZ02
BN96-13008D
Rear Cover
NZ02
BN96-13019A
Stand Guide
NZ02
BN96-13431A
Stand Base
NZ02
BN40-00162A
Tuner
NZ02
BN96-12723U
LVDS Cable
NZ02
BN96-12941K
Speaker
NZ02
BN96-13273A
Speaker
NZ02
BN59-01042A
Remote
NZ02
BN63-01798B
Cleaning Cloth
NZ02
BN96-09872R
Power Cord
NZ02
BN96-10788A
Accessory Pack
Y Buffer
Y Main
Woofer
Fast Track Troubleshooting Manual, Rev. 1/10/12
X Buffer
SMPS
Logic
Buffer F Buffer E
X Main
Main
Page 2
PN50C6500TFXZA
Fast Track Troubleshooting Manual
Power On Sequence:
1. STBY 5V (CN801, #2, 5v)
2. PS_ON (CN801, #1, 3.3v-0v)
3. VS_ ON (CN802, #6, 0-3.3v)
4. Panel should illuminate briefly
Page 3
PN50C6500TFXZA
Fast Track Troubleshooting Manual
Power Supply Trouble Shooting Notes:
2010/2011 models
Will not be run with the “X” or “Y” main disconnected. The SMPS will
shut down immediately. However if a meter is first connected to the test point when power is applied it will read the correct voltage briefly before shut- ting down.(You have enough time to check key voltages)
CAUTION: Do not reconnect any connectors to SMPS or Y/X Boards
until power has been turned off long enough for Vs to drop below 10V or damage will occur to X or Y Boards.
SMPS Over Current Protection
If a short circuit occurs on either the VS or VA voltage lines, the SMPS stops operating, but should not fail. When the short circuit is removed from the source line, the Power Supply will operate normally again.
Many SMPS Supplies are replaced needlessly!
Sample
“VITAL SIGNS”
When troubleshooting, It’s very important to first check Vs, Va, Vsc & Ve
If Vs is missing (0V), disconnect power and check for short. Use ohm meter to measure resistance while disconnecting Y-Board & X-Board supply feeds one at a time. Turn Power On and Test SMPS with shorted connector removed for correct Vs voltage verification. (It may only come up briefly but to full level). Be careful not to reconnect power connectors until Vs falls below
10V.
If Va is low or missing, disconnect power connectors to Address Boards and Check to see if SMPS Supply is restored. (Note Va feed normally passes through the Y-Drive to the Address Boards (Logic Buffer Boards).
If Vsc is low or missing and Vs is OK, the failure is with the Y-Board
.
since the Y-Board generates the Vsc voltage from the supplied Vs. If Ve is low or missing and Vs is OK, the failure is with the X-Board since the
Ve is generated by the X-Board from the supplied Vs. (Please note: In some
rare cases the Ve is generated by the Y-Board fed to the X-Board.)
Other SMPS Voltages:
Check Low Voltage feeds to the Main Board and other supplied Assemblies.
3
Page 4
PN50C6500TFXZA
Fast Track Troubleshooting Manual
TROUBLESHOOTING VIDEO PROBLEMS
1. Verify Video Operation
a) Customer Picture Test (if available) b) “Display” (If display is OK source is suspected) c) Substitute with known good Source (external DVD or Signal Generator)
3. Determine cause
a) If Logic pattern is NG; Logic
board, Logic buffers or
Panel are suspect.
b) If FBE patterns is NG and
Logic is OK; Main or LVDS cable are suspect.
c) If both are OK it is likely a
source issue.
2. Using Test Patterns in Service Mode
- ENTERING SERVICE MODE –
Customer Remote: Service Remote:
1. Power off 1. Power On
2. Mute, 182, Power 2. Info, Factory
4
Page 5
Model
Code:
PN50C6500TFXZA
Option
Side Label
Type
Model
Tuner
Light Effect
Country
Front Color
NZ01
50FArV4
PC6500
SEMCO
OFF
USA
T-C-Black
NZ02
50FArV4
PC6500
SEMCO
OFF
USA
T-C-Black
N003
50FArV4
PC6500
SEMCO
OFF
USA
T-C-Black
N004
50FArV4
PC6500
SEMCO
OFF
USA
T-C-Black
PN50C6500TFXZA
Fast Track Troubleshooting Manual
ALIGNMENTS & OPTION BYTES :
1. Check/Adj. VS, VA, VE, & VSC according to Panel Label and Diffusion test. (see bulletins for any special notes before making changes)
2. Check/Set Option Bytes:
- ENTER SERVICE MODE -
a) Customer Remote: Power off; Mute, 182, Power On
b) Service Remote: Power On; Info, Factory
DIFFUSION TEST/ADJ. (cell miss-firing, older units)
- Allow the unit to warm up 15 to 20 minutes
- Access the Burn Protect Sig. Pattern in Cust. Menu.
-Adjust the Vs volts until screen errors are gone in both dark and bright areas.
- Adjust the Vs volts within +/- 10V on the panel label.
SPECIAL NOTES:
See bulletin “Red Dots” for correction/
adjustments for this model.
5