Samsung AVXCSH023CE, AVXWNH060CE, AVXCSH032CE, AVXCSH040CE, AVXC4H052CE Service Manual

...
SYSTEM AIR CONDITIONER
INDOOR UNIT
AVXCSH023/032/040CE AVXC4H052/072/100/110/145CE AVXCMH032/040/052/060CE AVXDSH020/032/040/052/072/100/110/145CE AVXDUH100/110/145CE AVXWVH020/032/040/052/060CE AVXWNH020/032/040/052/060CE ND023/032/0401HXCA ND052/072/100/1454HXCA ND032/040/052/060MHXCA ND020/032/040/052/072/100/110/145LHXCA ND100/110/145SHXCA ND220/280HHXCE(CA) ND020/032/040/052/060VHXCA ND020/032/040/052/060NHXCA ND052/072CHXCA ND020/032/040/052/060QHXCA ND052/072/100/110/1454HXCB
OUTDOOR UNIT
RVXVHT075/100/125FE RD040/050MHXCA RD075/100/125VHXFA RD075/100/125VRXFA
AIR CONDITIONER CONTENTS
1. Precautions
2. Product Specifications
3. Disassembly and Reassembly
4. Troubleshooting
5. Exploded Views and Parts List
6. PCB Diagram and Parts List
8. Schematic Diagram
9. Reference Sheet
Refer to the service manual in the GSPN(see the rear cover) for the more information.
Contents
1. Precautions
1-1 Precautions for the Service ························································································································· 1-1 1-2 Precautions for the Static Electricity and PL ························································································ 1-1 1-3 Precautions for the Safety ··························································································································· 1-2 1-4 Others ·································································································································································· 1-2
2. Product Specifications
2-1 The Feature of Product ································································································································· 2-1 2-1-1 Feature ··················································································································································· 2-1 2-1-2 Changes in comparison to basic model ··················································································· 2-22 2-2 Product Specifications ·································································································································· 2-24 2-2-1 Indoor Unit ··········································································································································· 2-24 2-2-2 Outdoor Unit ······································································································································· 2-47 2-3 Accessory and Option Specifications ····································································································· 2-50 2-3-1 Accessories ··········································································································································· 2-50
3. Disassembly and Reassembly
3-1 Indoor Unit ························································································································································ 3-2 3-2 Outdoor Unit ···················································································································································· 3-11
 ·························································································································································· 1-1
······························································································································ 2-1
············································································································ 3-1
4. Troubleshooting
4-1 Setting Option Setup Method ·················································································································· 4-1 4-1-1 PCB option code input method ·································································································· 4-1 4-1-2 Setting an indoor unit address and installation option ···················································· 4-11 4-1-3 Option Items ········································································································································ 4-17 4-2 What to check before diagnosis ··············································································································· 4-19 4-2-1 Lamp combination expression method display (cassette type indoor unit) ··········· 4-19 4-2-2 4-3 How to take measures for each symptom (Model : RVXVHT075/100/125FE, RD075/100/125VHXFA) ···························································· 4-31 4-3-1 Outdoor unit operation flow ········································································································ 4-36 4-3-2 Indoor Unit ROOM sensor Error (Open/Short) ······································································ 4-40 4-3-3 Indoor unit EVAP IN sensor Error (Open/Short) ···································································· 4-41 4-3-4 Indoor EVAP OUT sensor Error (Open/Short) ········································································· 4-42 4-3-5 Indoor heat exchanger’s EVAP IN sensor dislocation error ·············································· 4-43 4-3-6 Indoor Heat Exchanger’s EVA OUT sensor dislocation error (Open/Short) ··············· 4-44 4-3-7 4-3-8 Operational error of indoor Unit’s Clean Fan (Open/Short) ············································· 4-46
Numeric type display(outdoor unit, Wired remote controller, wall-mount type etc.)
Simultaneous Indoor heat exchanger’s EVA IN, OUT sensor dislocation error (Open/Short)
·············································································································································· 4-1
··· 4-29
··· 4-45
Contents
4-3-9 Breakdown of EEV (2nd) ··················································································································· 4-47
nd
4-3-10 Problem with EEV closure (2 4-3-11 4-3-12 The operational error of Indoor Unit’s Fan Motor ······························································ 4-50 4-3-13 EEPROM error ···································································································································· 4-51 4-3-14 Option error of the Remote Controller for an Indoor Unit ············································ 4-52 4-3-15 Error due to confused use of Fahrenheit and Celsius ······················································ 4-53 4-3-16 Error due to incorrect Indoor Unit Power/Communication Cable Connection ···· 4-54 4-3-17 SPi Feedback Error ·························································································································· 4-55 4-3-18 Communication error between Indoor and Outdoor units during Tracking ········· 4-56 4-3-19 4-3-20 Communication error between Main and Sub Micoms of an Outdoor unit or
4-3-21 Outdoor Temperature Sensor error ························································································· 4-60 4-3-22 Outdoor Temperature dislocation error ················································································ 4-61 4-3-23 COND OUT Temperature Sensor error (Open/Short) ······················································· 4-62 4-3-24 Outdoor COND OUT Sensor dislocation error ···································································· 4-63 4-3-25 Discharge Temperature Sensor error for a digital Compressor (Open/Short) ······· 4-64 4-3-26 4-3-27 Compressor’s Discharge Temperature Sensor dislocation error ································· 4-66 4-3-28 4-3-29 4-3-30 SUMP Temperature Sensor error (Open/Short) ·································································· 4-69 4-3-31 High Pressure Temperature Sensor error (Open/Short) ·················································· 4-70 4-3-32 Low Ppressure Temperature Sensor error (Open/Short) ················································ 4-70 4-3-33 Oil Balance Valve Temp. Sensor error (Open/Short) ························································ 4-71 4-3-34 SUCTION Temperature Sensor error (Open/Short) ··························································· 4-72 4-3-35 Double pipe temperature sensor error ·················································································· 4-73 4-3-36 Main Cooling Sol Valve Open Error ·························································································· 4-74 4-3-37 EVI IN Temperature Sensor error (Open/Short) ·································································· 4-75 4-3-38 EVI OUT Temperature Sensor error (Open/Short) ······························································ 4-76 4-3-39 4-3-40 4-3-41 Protection Control by Sump Sensor Error ············································································· 4-79 4-3-42 4-3-43 3 Detection of phase negative voltage sequence, Phase fail ······································· 4-81 4-3-44 4-3-45
4-3-46 EVI EEV Open Error ························································································································· 4-84
: Detection of Floating Switch of Indoor Unit’s Drain Pump ·························· 4-49
Communication error between Indoor & Outdoor units after Completing Tracking
among Outdoor Units ··················································································································· 4-59
Discharge Temperature Sensor error for a fixed scroll Compressor (Open/Short)
:
Dislocation error of Compressor SUMP Temperature (oil temperature) Sensor
: Dislocation error of Suction Temperature Sensor ············································· 4-68
: Comp. Down due to a Protective Control of High pressure ························· 4-77 : Comp. Down due to a Protective Control of Low Pressure ·························· 4-77
: Comp. Down due to Discharge Temperature Sensor of a Compressor ··· 4-80
: Comp. Down due to compression rate control ················································· 4-82 :
Self-diagnosis of Oil valve(balance keeping valve) 1(open or closure
breakdown, sensor dislocation or defect)
) ·································································································· 4-48
··· 4-58
··· 4-65
··· 4-67
···························································· 4-83
Contents
4-3-47 , : Prohibition of the operation of Compressor due to
OoutdoorTemperature ·················································································· 4-85 4-3-48 High Pressure below the Average before Cooling (Unable to Restart) ···················· 4-86 4-3-49 Instantaneous Blackout ················································································································ 4-87 4-3-50 Error by High Temperature in an Outdoor Fan Motor ····················································· 4-87 4-3-51 RPM Error of an Outdoor Fan Motor ······················································································· 4-87 4-3-52 Over-Voltage Error of an Outdoor Fan Motor ····································································· 4-88 4-3-53 Counter-Rotation Error of an Outdoor Fan motor ···························································· 4-88 4-3-54 4-3-55 4-3-56 Liquid Compressor Protection Control ·················································································· 4-91 4-3-57 Breakdown of an EEV(1 4-3-58 Breakdown of an EEV closure(1 4-4 How to take measures for each symptom(Model : RD040/050MHXCA) 4-4-1 Indoor Unit ROOM sensor Error (Open/Short) 4-4-2 Indoor unit EVAP IN sensor Error (Open/Short) 4-4-3 Indoor EVAP OUT sensor Error (Open/Short) 4-4-4 Indoor Heat Exchanger’s EVAP IN sensor dislocation error 4-4-5 Indoor Heat Exchanger’s EVA OUT sensor dislocation error (Open/Short) 4-4-6 4-4-7 4-4-8 4-4-9 4-4-10 4-4-11 4-4-12 EEPROM error 4-4-13 Option error of the Remote Controller for an Indoor Unit 4-4-14 Error due to confused use of Fahrenheit and Celsius 4-4-15 Error due to incorrect Indoor Unit Power/Communication Cable Connection 4-4-16 Communication error between Indoor and Outdoor units during Tracking 4-4-17 4-4-18 Communication error between main PCB and inverter PCB during Tracking 4-4-19 Outdoor Temperature Sensor error 4-4-20 COND OUT Temperature Sensor error (Open/Short) 4-4-21 4-4-22 Discharge Temperature Sensor error (Open/Short) 4-4-23 4-4-24 High Pressure Temperature Sensor error (Open/Short) 4-4-25 Double pipe temperature sensor error(Open/Short) 4-4-26 OLP sensor error (Open/Short)
: Over-voltage error of Compressor ·········································································· 4-89 : Low-amperage error of Compressor ······································································ 4-90
st
) ············································································································· 4-92
st
) ····························································································· 4-93
································
·····································································
···································································
········································································
·············································
···············
:
Simultaneous Indoor Heat Exchanger’s EVA IN, OUT sensor dislocation error (Open/Short) : Breakdown of EEV (2nd) : Problem with EEV closure (2nd) : Detection of Floating Switch of Indoor Unit’s Drain Pump
: The operational error of Indoor Unit’s Fan Motor : Mixed operation Error
··································································································································
································································································
··················································································
····························
············································
·································································································
············································
·····················································
········
Communication error between Indoor & Outdoor units after Completing Tracking
························································································
······················································
: Outdoor COND OUT Sensor dislocation error
: Compressor’s Discharge Temperature Sensor dislocation error
································································································
···················································
·························································
················
·················································
······················································
······
····
····
···
4-94 4-97 4-98 4-99 4-100 4-101 4-102 4-103 4-104 4-105 4-106 4-107 4-108 4-109 4-109 4-109 4-110 4-111 4-112 4-113 4-114 4-115 4-116 4-117 4-118 4-119 4-120
Contents
4-4-27 : Freezing control causes comp. down 4-4-28 4-4-29 4-4-30 4-4-31 4-4-32 4-4-33 4-4-34 4-4-35 4-4-36
5. Exploded Views and Parts List
: High voltage protection compressor stopped : Compressor down by low pressure sensor protection control : Dischase temperature sensor error , , :
Abnormal outside temperature halts operation of the compressor : Current protection control causes comp. down : OLP protection control caused comp. down , : Electrical malfunctions of the outdoor machine : EEV Off-malfunctions (1st) : EEV Off inefficiently (1st)
·························································································
·····························································································
·········································································································· 5-1
···································································
··················································
··················
·······································································
···
···············································
·····················································
······························
4-121 4-122 4-123 4-124 4-125 4-125 4-126 4-127 4-128 4-128
5-1 Indoor Unit ························································································································································ 5-1 5-1-1 Slim 1 way cassette type ················································································································· 5-1 5-1-2 Mini 4 way cassette type ················································································································ 5-7 5-1-3 4 way cassette type ··························································································································· 5-11 5-1-4 Globel 4 way cassette type ············································································································ 5-17 5-1-5 Duct type(Slim I) ································································································································· 5-23 5-1-6 Duct type(Slim II) ······························································································································· 5-25 5-1-7 Duct type(Slim III) ······························································································································ 5-27 5-1-8 Duct type(MSP) ··································································································································· 5-29 5-1-9 Duct type(BIG) ····································································································································· 5-33 5-1-10 Wall-mounted type(Vivace) ········································································································ 5-35 5-1-11 Wall-mounted type(Neo Forte without EEV) ······································································· 5-39 5-1-12 Wall-mounted type(Neo Forte with EEV) ·············································································· 5-43 5-1-13 Ceiling type ········································································································································· 5-47 5-2 Outdoor Unit ···················································································································································· 5-51 5-2-1 RVXVHT075/100FE, RD075/100VHXFA ····················································································· 5-51 5-2-2 RVXVHT125FE, RD125VHXFA ········································································································ 5-55 5-2-3 RD075/100VRXFA ······························································································································· 5-59 5-2-4 RD125VRXFA ········································································································································ 5-63 5-2-5 RD040/050MHXCA ···························································································································· 5-67
6. PCB Diagram
6-1 Indoor Unit ························································································································································ 6-1 6-1-1 Slim 1 way cassette type ················································································································· 6-1 6-1-2 4 way cassette type ··························································································································· 6-3 6-1-3 Mini 4 way cassette type ················································································································ 6-4 6-1-4 Duct type(Slim) ··································································································································· 6-5
······················································································································································· 6-1
Contents
6-1-5 Duct type(MSP) ··································································································································· 6-9 6-1-6 Duct type(BIG) ····································································································································· 6-11 6-1-7 Wall-mounted type(Neo Forte without EEV) ········································································· 6-15 6-1-8 Wall-mounted type(Neo Forte with EEV) ················································································ 6-19 6-1-9 Wall-mounted type(Vivace) ··········································································································· 6-23 6-1-10 Ceiling type ········································································································································· 6-26 6-2 Outdoor Unit ···················································································································································· 6-27 6-2-1 RVXVHT075/100/125FE, RD075/100/125VHXFA ·································································· 6-27 6-2-2 RD040/050MHXCA ···························································································································· 6-33
7. Wiring Diagram
7-1 Indoor unit ························································································································································· 7-1 7-1-1 Slim 1 way cassette type ················································································································· 7-1 7-1-2 4 way cassette type ··························································································································· 7-2 7-1-3 Mini 4way cassette type ·················································································································· 7-3 7-1-4 Duct type(Slim I, II) ···························································································································· 7-4 7-1-5 Duct type(Slim III) ······························································································································ 7-5 7-1-6 Duct type(MSP) ··································································································································· 7-6 7-1-7 Duct type(BIG) ····································································································································· 7-7 7-1-8 Wall Mounted type(Vivace) ··········································································································· 7-8 7-1-9 Wall Mounted type(Neo Forte with EEV) ················································································· 7-9 7-1-10 Wall Mounted type(Neo Forte without EEV) ······································································· 7-10 7-1-11 Distributor kit ···································································································································· 7-11 7-1-12 Ceiling type ········································································································································· 7-12 7-2 Outdoor Unit ···················································································································································· 7-13
8. Schematic Diagram
8-1 Indoor Unit ························································································································································ 8-1 8-1-1 Slim 1 way cassette type ················································································································· 8-1 8-1-2 4 way cassette type ··························································································································· 8-2 8-1-3 Mini 4 way cassette type ················································································································ 8-3 8-1-4 Duct type ··············································································································································· 8-4 8-1-5 Duct type(BIG) ····································································································································· 8-5 8-1-6 Wall-mounted type(Neo Forte/Vivace) ····················································································· 8-7 8-1-7 Wall-mounted type(Neo Forte with EEV) ················································································ 8-8 8-1-8 Ceiling type ··········································································································································· 8-9 8-2 Outdoor Unit ···················································································································································· 8-10 8-2-1 RVXVHT075/100/125FE, RD075/100/125VHXFA ·································································· 8-10 8-2-2 RD040/050MHXCA ···························································································································· 8-15
················································································································································ 7-1
······································································································································ 8-1
Contents
9. Reference Sheet
9-1 Index for Model Name ·································································································································· 9-1 9-1-1 Indoor Unit ··········································································································································· 9-1 9-1-2 Outdoor Unit ······································································································································· 9-3 9-2 Refrigerant Circuit Diagram ························································································································ 9-5 9-2-1 Cycle Operation Mode ····················································································································· 9-5
··············································································································································· 9-1
1. Precautions
1-1 Precautions for the Service
OUse the standard parts when replacing the electric parts.
– Confirm the model name, rated voltage, rated current of the electric parts.
ORepair the disconnection of HARNESS securely when repairing the break down.
– If there is any connection error, it causes an abnormal noise and incorrect operation.
OIn case that you assemble or disassemble the products with laying it on the side, do work on the work cloth.
– If not, the exterior of products can be scratched.
ORemove dust and foreign materials from harness, connection part, and inspection part thoroughly when repairing the
break down.
– It protects the danger of fire such as tracking and short.
OTighten tightly the service valve of outdoor unit and the cap of charging valve with a monkey spanner.
OCheck the assembly status of parts after repairing the break down.
– It should be same as the status before repairing.
1-2 Precautions for the Static Electricity and PL
OAs the PCB power terminal has a weakness for the static electricity, pay attention to it during the repair and measurement.
– Work with insulation gloves during the repair and measurement of PCB.
OCheck the distance between the product and the other electronic appliances such as TV, video, and audio.
It should be over 6.6ft.
– If not, it causes a bad picture quality or a noise.
ORepairing the products by consumer should be strictly prohibited.
– There is a danger of electric shock or fire due to incorrect disassembly.
Samsung Electronics 1-1
1-3 Precautions for the Safety
ODo not pull any electric wires and do not touch an auxiliary power switch with a wet hand.
– There is a danger of electric shock or fire.
OIn case any wire or power plug has been damaged, replace it to eliminate any possible danger.
ODo not bend the power cord by force and do not put any heavy object on the power cord.
– There is a danger of electric shock or fire.
ODo not use multi socket.
– There is a danger of electric shock or fire.
OGround the product if necessary.
– Be sure to ground the product if there is any danger of electric leakage due to water or moisture.
OBe sure to turn off the auxiliary power switch or pull out the power plug during replacement or repair of electric parts.
– There is a danger of electric shock.
OIn case the product will not be in use for a long time, the battery of remote control should be kept separately.
– Leakage of inside fluid can cause break down of remote control.
The installation must be done by the manufacturer or its service agent or a similar qualified person in order to avoid a hazard.
O
– Installation by an unqualified person may cause a water leakage, electric shock or fire and so on.
O
The electric work must be done by service agent or similarly qualified persons according to national wiring regulations and use only rated cable.
– If the capacity of the power cable is insufficient or electric work is not properly completed, electric shock or fire may occur.
O
Use only rated parts and tools.
– If you don’t use the rated parts and tools, it can cause trouble with the air conditioner and bring about injury.
O
If any gas or impurities except R410A refrigerant come into the refrigerant pipe, serious problem may occur and it may cause
injury.
O
Leak test must be done using only Nitrogen(NO2)gas.
O
R410A refrigerant is used for DVM PLUS ,,,, SUPER FJM air conditioner.
– When using R410A, moisture or foreign substances may affect to the capacity and reliability of the product.Safety precautions
must be taken when installing the refrigerant pipe.
– The design pressure of the unit is 4.1MPa. Select appropriate material and thickness according to the regulations.
– R410A is a quasi-azeotrope of two refrigerants.
Make sure to charge liquid one when adding refrigerant. If you charge gaseous refrigerant, it may affect the capacity and reliability of the product as a result of change formation of the refrigerant.
O
Connect only the indoor units fit on R410A refrigerant. Check whether the indoor units can be connected with the product’s catalogue. (When incorrect indoor units are connected, they cannot operate normally.)
1-4 Others
OWhen installing, make sure there is no leakage. When recovering the refrigerant, ground the compressor first before removing the
connection pipe. If the refrigerant pipe is not properly connected and the compressor works with the service valve open, the pipe inhales the air and it makes the pressure inside of the refrigerant cycle abnormally high. It may cause explosion and injury.
1-2 Samsung Electronics
2. Product Specifications
2-1 The Feature of Product
2-1-1 Feature
2-1-1-1 RVXVHT075/100/125FE, RD075/100/125VHXFA, RD075/100/125VRXFA
1. Introduction
DVM PLUS III is a module multi-system air conditioner that has the world’s largest capacity(7.5~37.5HP) with the application of a
DVI (Digital Vapor Injection) compressor, and can connect up to a maximum of 49 indoor units.
• The highest COP levels in the industry
• The smallest installation space requirement in the world
• The highest heating capacity and COP in low temperature condition (14°F/-10°C)
• Possible to connect up to 49 indoor units
• Digital unit module
2.
New technology of DVM PLUS III
Q Digital hybrid system
DHS (Digital Hybrid System) is a brand new concept system
composed of DVI (Digital Vapor Injection) compressor, vapor injection technology and turbo intercooler. These 3 factors together provide highly efficient performance.
1) DVI compressor
Efficient and reliable DVI (Digital Vapor Injection) compressor
coupled with vapor injection technology has been applied to improve cooling and heating performance and energy efficiency.
Compressor
Vapor
injection
port
DVI
PWM valve
Vapor
Injection
Discharge port
Suction port
Oil port
Turbo
Intercooler
Gas inlet
Samsung Electronics 2-1
Product Specifications
2) Vapor injection technology
Improved cooling and heating performance and COP by a new technology of two stage compression. As injecting optimized
mid-range pressure refrigerant, this technology achieved the high heating performance and COP under the lowest temperature, which leads the industry.
• Increase refrigerant flow rates with a new vapor injection technology.
• Improved sub-cooling necessary for long piping installation while increasing cooling and heating performance and COP.
More mass flow passing Indoor unit
Evaporator (ID)
DVI compressor
Vapor injection
Condenser (OD)
Mo
Mi
Mo + Mi
Solenoid Valve
2nd EEV
Flash tank
1st EEV
1st Expansion
2nd Expansion
Vapor injection reduces the liquid enthalpy in flash tank, facilitating heat exchanger to absorb heat more.
increases heating capacity.
Mo + Mi
Mi
Vapor injection
Mo
Enthalpy (kJ/kg)
Injection point
3) Turbo intercooler (RVXVH075/100/125FE, RD075/100/125VHXFA Only)
Turbo intercooler (Shell & tube type) improves cooling and heating COP and secures reliable operation of installation with long
piping [200m(656ft)].
Subcooling liquid refrigerant
Low temperature gas
refrigerant
Low temp. liquid
refrigerant
Saturated liquid
refrigerant
Temperature
High
Low
4) Plate type intercooler (RD075/100/125VRXFA Only)
The plate type intercooler is the new concept intercooler technology which is more advanced than the existing double layered
pipe type and Shell & Tube type heat exchanger. The plate type intercooler increases heat exchange efficiency by 30% and provides stable performance with long piping and vertical piping.
Double layered pipe Shell & Tube Plate type
Turbo Inter-
Cooler
DVI
Compressor
EER Heat transfer efficiency
Efficiency Rate
Plate type
Structure Diagram
2-2 Samsung Electronics
Product Specifications
Q High efficiency Ø0.32 heat exchanger
Efficient Ø0.32 grooved tube reduced pressure loss while increasing heat exchange rates to improve COP. Grooved shape is designed
to be high and slim to increase heat transfer performance inside the tube.
New grooved shape (High and slim)
Company A
Item Improved heat exchanger
Diameter(inch)
Heat transfer surface area
Pressure loss in heat
exchanger
Evaporation
Condensation
Inside heat transfer performance
Ø0.28
14.1%
10.3%
30.8%
o
19%
Ø0.32
n
p p n
Pressure resistance same
Q New G-fin
Highly efficient new G-fin increased heat transfer performance, reinforced corrosion resistance, and increased operating duration in
frost condition.
• Heat transfer performance improved by 13% compared to the conventional fin, even with the equivalent pressure loss.
• Epoxy acrylic coating reinforced corrosion resistance.
• 1.4 times longer heating operation in frost condition thanks to new G-fin.
(New G-fin)
60
50 40 30 20 10
0
-10
-20
Eva. Cond., temperature (°C)
-30 030
Time (min.)
5000
4000
3000
2000
1000
Capacity, Power output (W)
60
Conventional model (Louver fin)
0
030
60 90 120
Time (min.)
Anti corrosive layer Epoxy acrylic
Raw aluminum material
92μm
Hydrophilic layer Acrylic resin + surfactant
1.0μm
2.0μm
Samsung Electronics 2-3
Product Specifications
Q Newly designed fan guard
Fan guard has been optimized to improve air volume and reduce noise and vibration.
• BLDC motor, which is 2.7% more efficient than the competitors has been applied.
• High static pressure propeller fan and the optimum Bell mouth figuration for high external static pressure. (8mmAq)
Conventional model
100
90
80
70
60
Efficiency
50
40
30
200 300 400 500 600 700 800 900
RPM
DVM PLUS III Company A
1000
2-4 Samsung Electronics
Product Specifications
Q Upgraded control solutions
1) Easy management system
A wide range of control system is provided to support various needs and applications such as individual or central control and
automated building management.
2) Enhanced remote analysis System managers, installers or service engineers can monitor the whole air-conditioning system through the internet, analyzing
the operation and providing service promptly.
Internet
Samsung Electronics 2-5
Product Specifications
3) Simple contact control Contact interface makes it possible to connect mechanical contacts to indoor units directly, allowing individual and group control
as well as malfunction monitoring of the indoor units.
Z
Direct ON/OFF indoor unit control
Emergent control
Schedule control
Window
synchronization
Key holder
synchronization
Operation state
Normal
Faulty
4) Wrong wiring protection Non-polarity communication ensures Normal Operation of air-conditioning system even in case of wrong communication wiring.
Furthermore, power protection mechanism protects indoor units from blowing out under a crossed connection between power and communication wires, resulting in enhancing system safety and robustness.
Z
Z
Automatic recovery for incorrect
Protection against wrong power line connection
communication wiring
Outdoor unit
F1 F2
L N F1 F2
Indoor unit 1
Non-Polarility
Wrong wiring
Wrong wiring
L N F1 F2
Indoor unit 1
Outdoor unit
F1 F2
L N F1 F2
Indoor unit 1
Wrong wiring Wrong wiring Wrong wiring Wrong wiring
Protection
L N F1 F2
Indoor unit 1
Outdoor unit
F1 F2
Wrong wiring
L N F1 F2
Indoor unit 1
Protection
L N F1 F2
Indoor unit 1
5) Wireless test run tool Zigbee wireless test run tool provides installers with easy and convenient control and monitoring of the outdoor unit and 49 indoor
units without bothersome wiring.
2-6 Samsung Electronics
Product Specifications
3. Main features of DVM PLUS III, DVM PLUS III HR
T High Performance and Efficiency
Q High COP
High efficiency DVM PLUS III has improved average cooling and heating COP compared to conventional products and achieved the
world’s top class energy efficiency.
• DHS(Digital Hybrid System) technology increased refrigerant flow rate and evaporation enthalpy difference.
• Wide Ø0.32 Grooved tube and new G-fin increased heat exchange efficiency.
• The best BLDC motor in the industry and optimum fan guard design increased efficiency.
17.5HP7.5HP
&RQYHQWLRQDO&RQYHQWLRQDO
&RPSDQ\$&RPSDQ\$
 


Q Improved heating performance
Vapor injection technology has improved heating performance
by 20% at a low ambient temperature of (14ºF/-10ºC).
&RQYHQWLRQDO&RQYHQWLRQDO
&RPSDQ\$&RPSDQ\$
10HP
Company ACompany A
ConventionalConventional




21kW
21kW
25kW
Samsung Electronics 2-7
Product Specifications
T Simple and Easy Installation
Q Digital unit module
Digital unit module combination enables the system to alternate
compressor operation to prolong each compressor’s life cycle and improves COP with part loads.
DVI
FVI
Scroll
Scroll
• Control the compressor capacity precisely.
• Ensure long life cycle by alternating operation of the DVI compressors.
• Improve COP using multiple heat exchangers of outdoor units at part loads.
A unit B unit
Q Free installation
DVM PLUS III provides the degree of freedom from priority of capacity when installing outdoor units in module.
DVI
Scroll
Scroll
FVI
7.5HP
(Digital unit)
DVM PLUS III
12.5HP
(Digital unit)
Any priority is OK.
10HP
(Digital unit)
Conventional model
7.5HP
(Fixed unit)
A digital outdoor unit with the largest
10HP
(Fixed unit)
capacity should come last.
(Digital unit)
12.5HP
An outdoor unit with the largest capacity
Company A
14HP 10HP
>
should come first.
8HP
>
Q Small size and light weight
To facilitate the convenience and mobility of module installation, DVM PLUS III is the best compact air conditioner in the world
with its small size and weight. It reduces the burden of weight and minimizes the required installation space (it can be installed in the rooftop), ensuring a more spacious place for relaxation, parking lots, or additional offices, for instance.
Z
Rooftop space (Garden)
Item
Conventional model
Design
Weight
250kg(551lbs) (100%) 240kg(529lbs) (96%)
2-8 Samsung Electronics
Product Specifications
Q Rapid installation
DVM PLUS III supports more convenient and rapid installation work through the improvement of service valve structure and the
provision of branch joints.
• Improved the location of service valve and welding points for aiding piping connection work
• Modified the plate into open structure type for keeping interference out during welding work
• The application of OTS (One Touch Solution) valve that makes it easy to connect pipes and to open or shut valves.
DVM PLUS
423mm(16.65inch)
120mm(4.72inch)
50mm(1.97inch)
260mm(10.24inch)
Ô Y, Header, Outdoor joints allow easy piping expansion and reduction with insulations to facilitate the installation.
Y-joint Outdoor joint Header joint
Q Free piping & wiring directions
DVM PLUS III is easy to install as its piping can be connected from front, right, left and bottom side.
Wiring hole (Conduits) adds convenience as it allows power and communication lines to be connected in various ways and directions.
Samsung Electronics 2-9
Free piping connection Free wiring connection
Product Specifications
Q The world’s longest piping length
DVM PLUS III has an actual piping length of 656ft, with the maximum
piping length of 147.6ft from the first branch joint to the farthest indoor unit, thereby providing convenience and flexibility for installa­tion for commercial buildings.
Level differences
between indoor &
outdoor unit : 164ft
• The longest piping length : 721.8ft (Equivalent)
• Total piping length: 3280.8ft
• From the first branch joint to the farthest indoor unit : 295.3ft
- Upsize all pipes between branch joints. (liquid&gas)
Level difference between indoor units : 49.2ft
Q Automatic piping length recognition
With automatic piping length recognition, installation can be carried out without extra PCB setup.
P
The longest pipe length : 721.8ft (Equivalent)
The first branch joint to the farthest indoor unit : 147.6ft (1 size up : 295.3ft)
∆P
pressure according to
pressure drop of piping
(
∆P
Q High external static pressure
To respond to a range of various installation environments, DVM PLUS
III is designed to be used even in external static pressure of 8 mmAq.
∆P{
Corrected target
compensation)
h
Indoor’s low pressure (Eva. inlet temperature of indoor units)
Outdoor unit’s low pressure
2-10 Samsung Electronics
Product Specifications
T Easy Maintenance
Q Auto data backup in PCB
In case of problems in product, operation information of last 20 mins is stored before system shut down. Therefore, DVM PLUS III can
be diagnosed rapidly and serviced.
High pressure
Data
SNET 1+
Data storing
Q Refrigerant pump-down and pump-out
DVM PLUS III provides several functions to facilitate the replacements of product, additional installation and maintenance without
much effort.
Fan motor RPM
Current
System stop
Time
Z
Refrigerant pump-down function
In case of moving outdoor units, maintenance of pipes between indoor units, between outdoor units and indoor units, it is possible that recover refrigerant into outdoor units.
Z
Refrigerant pump-out function
In case of maintenance of outdoor units, it is possible that recover refrigerant into indoor or pipes.
Breakdown
Breakdown
Samsung Electronics 2-11
Product Specifications
T High Reliability
Q Optimum control and high reliability of DVI scroll compressor
1) DVI scroll compressor As DVM PLUS III employs a DVI scroll compressor, it can adjust not only the compressor capacity linearly in accordance with
indoor loads, but at minimum load. Therefore it is superior to Inverter system in creating a pleasant indoor environment and energy saving.
DVI
DVI
compressor
DVI
compressor
compressor
FVI
compressor
Inverter
compressor
Company A
2) Dual compliances Through rigorous tests such as High load and liquid
flood back, DVI compressor is evaluated as reliable as it can operate under any conditions.
°F
°C
170
Condensing temperature
°F
°C
Evaporating temperature
As DVI compressor is mechanically simple in structure, it has strong durability, and flexibility in radial and axial directions while being
strong against debris, liquid flood back, leakage of refrigerant inside the scroll, and internal overheating. In particular, it is very strong against partial abrasion and compressor burn out by internal overheating compared with inverter compressor that employs tip seal techniques.
Z
Radial compliance
Z
Axial compliance
Floating seal
Debris
2-12 Samsung Electronics
Lower scroll (Orbiting)
Upper scroll (Fixed)
Product Specifications
Q Compressor operating pattern
Digital unit’s module installation secures reliability of long life cycle with sequential activation of compressors and improves part load
efficiency as it is possible to use bigger outdoor units to take care of part load.
Q Oil balancing and recovery technology
In terms of oil recovery that is the most important operation in module system air conditioner’s reliability,
DVM PLUS III :
• Achieves continuous cooling or heating during oil recovery operation.
• Allows level difference between outdoor unit module.
Ô DVM PLUS III’s oil recovery has much higher reliability as internal and external oil balancing take place simultaneously.
Z
Oil balancing
Z
Oil recovery
Company A
Oil recovery during
cooling operation
Oil recovery during
heating operation
Cooling operation Cooling operation
Heating operation Cooling operation
Q Acceleration life cycle test
All parts fitted to DVM PLUS III ensure reliability for life cycle through ALT (Acceleration Life cycle Test ).
Samsung Electronics 2-13
Product Specifications
Q Robust design
DVM PLUS III ensures product reliability through robust design against all
potential defects that can occur in the process of production, distribution and customers’ usage environment.
Robust design through CAE
T Sound Quality
Q Sound quality
DVM PLUS III improves the problem of noise not only at the low sound level, but also at the actual sound quality level by:
• Developing a sound insulation material for compressor
• Improving fan guard air flow
• Adopting Ø0.32 heat exchanger
Ô In particular, it enhances sound quality as it improves compressor noise by 4dB(A) by employing new material with better
acoustic absorptivity.
1.200
1.000
0.800
0.600
0.400
Acoustic absorptivity
0.200
0.000
250 500 1000 2000 4000
Frequency (Hz)
Conventional material
New material
2-14 Samsung Electronics
T Environment Friendly
Q Small refrigerant charge amount
With consideration of environment, DVM PLUS III is less charged compared to competitor’s products.
of (10HP) Company A (10HP)
Refrigerant volume 7.5kg(16.5lbs) 8.4kg(18.5lbs)
% 89 100
Q Refrigerant leakage prevention
To prevent refrigerant leakage, we provide how to diagnose any refrigerant leakage in operation. Also,
changing service valves from flange type to brazed type further prevents refrigerant leakage.
Product Specifications
Q RoHS compliance
RoHS restriction only applies to small or large household appliances, IT equipment, lightings, power train, toys, leisure or sports
equipment, and vending machines.
Samsung expands the RoHS restriction into its entire range of products based on its own environmental policies.
Q Lead-free
DVM PLUS III is an environment friendly product that prevents pollution problems caused by the use of lead, by applying lead-free
indoor and outdoor PCBs.
Samsung Electronics 2-15
Product Specifications
4. DVM PLUS III HR
1) Versatile application
As DVM PLUS III HR allows a simultaneous cooling and heating operation with one system, the product makes it possible for a wide
range of applications.
• Great for places where simultaneous cooling and heating operation is required such as hotels, nursing homes, conference rooms, etc.
• For seasonal air-conditioning which may need a simultaneous cooling and heating operation.
• In case of medium or large office, DVM PLUS III HR satisfies cooling and heating operation simultaneously for the requirements of
interior and perimeter zone.
Z
Simultaneously cooling and heating for individual rooms
Heating
Cooling
Heating
Z
Simultaneously cooling and heating for each zone
Perimeter Zone : Heating Interior Zone : Cooling
MCU (Mode Change Unit)
Cooling
Cooling
Heating
2-16 Samsung Electronics
DVM PLUS III HR
2) High COP
P
As DVM PLUS III HR utilizes the retrieved energy from indoor
cooling operation for heating, which has a high energy efficiency and is further enhanced by our Vapor Injection technology.
3) Wide operation range
DVM PLUS III HR can carry out a simultaneous cooling and
heating operation within a wide range of temperatures.
h
3
Indoor temp.
30 C
Simultaneous operation zone
18 C
16 C
Heating
-20 C -10 C 24 C 30 C 43 C
Product Specifications
Q3
Q2
Q1
h2h
1
h
Cooling
Outdoor temp.
4) New MCU
The MCU for DVM PLUS III HR has a double-tube heat
exchanger for securing high subcooling effect by the MCU itself, thus improving the reliability of the long piping and cooling and heating performance.
MCU subcooling heat exchanger
Samsung Electronics 2-17
Product Specifications
Feature(Cont.)
2-1-1-2 RD040/050MHXCA
Summarize
Overview
POWER SAVING
Samsung patented compressor
Samsung has been researching and developing compressors since the 70's. It has developed power saving compressors for more than thirty years. The SUPER FJM compressor adopts a double-rotor BLDC compressor with permanent magnets made by Samsung. Electricity for the compressor rotor is obtained from a neodium-iron-boron permanent magnetic material (boron magnet can attract iron material weighing 1000 times its own weight.) It strengthens the rotary moment of the compressor to maximize the entire efficiency of the compressor.
SUPER FJM is an all-in-one type product integrating the control R&D and Samsung patented compressor.
The air conditioning system uses the latest single tube in parallel connection and both the indoor and outdoor machines use independent electronic expansion valves to control the amount of coolant. You can connect a maximum of nine indoor machines to one outdoor machine.
SUPER FJM considers the trend in air conditioner use. It optimizes the energy efficiency of loads ranging from partial to full. It achieves an excellent energy effect for the users of the air conditioner.
BLDC electricity “Permanent magnet,” strong magnetic rotor
Double rotor compression cylinder
Nd-Fe-B Neodium-Iron-Boron magnet
SAMSUNG's double-rotor compressor has the upper and lower rotors designed symmetrically. The double rotor in symmetry can remove vibrations caused by the eccentric design of the cylinder.
2 rotors balancing the rotary moment
Permanent magnet rotor
Eccentric design
Nd-Fe-B Neodium-Iron-Boron magnet
Centered symmetry
Upper cylinder
Lower rotor
Upper rotor
Lower cylinder
High efficiency heat exchanger
SUPER FJM uses new multiple-teeth screw pipes with a diameter of 8 mm to improve the heat exchangeability of the pipe by 30.8%.
The water-friendly aluminum foil in the heat exchanger uses the G-fin patent design to improve the efficiency of heat exchange by 13%.
Multiple-teeth screw pipes
General screw pipes
DC fan electricity
The SUPER FJM outdoor machine uses DC fan electricity. The rotational speed of electricity is 100 RPM to 1050 RPM with step-free control. The electrical efficiency is improved by about
33% compared to AC electricity.
2-18 Samsung Electronics
Efficiency
Speed (RPM)
Product Specifications
Excellent energy efficiency
All the SUPER FJM series is superior to class 1 energy efficiency, the power saving standard for multiple connection (heat pump) machines. Its IPLV(C), the comprehensive energy efficiency is 4.94.
Lower energy consumption
Middle
Higher energy consumption
FRESHNESS AND HEALTH
Environment friendliness
SUPER FJM uses the environment-friendly coolant, R410A and all of its parts are in strict compliance with the EU environment guidelines (RoHS).
It controls toxic materials and prevents damage to the atmosphere. It does not spread any toxic materials indoors.
Strong heater
SUPER FJM adopts Samsung's high performance double-rotor compressor. Compared to other products, its heating effect at -10°C is about 20% higher.
à SUPER FJM's excellent energy efficiency
World's number one class
Energy efficiency
SUPER FJM
Comprehensive energy efficiency
SUPER FJM optimizes the aspects of environment friendliness, air control, toxic material control, low temperature heaters and noise. It guarantees a refreshing and healthy environment for the user.
Cadmium
Lead
Brominated flame retardant
Poly brom penyl
With smart
control
Hexa chromium
mercury
Heating performance (kW)
Heating performance improved 20%
External temperature(°C)
SUPER FJM measurement
Other product measurement
Other product measurement
Outside temperature rises about 7°C
Inside temperature rises about 3°C
The air conditioning capacity increases about 0.8HP
Deep level anti-bacteria
All of the SUPER FJM indoor heat exchanger aluminum foil is processed with special anti-bacteria paint to prevent the growth of bacteria in the humid inner area of the air conditioner and maintain clean indoor air.
Basic materials for the aluminum foil Anti-corrosion layer
(resin, anti-corrosion materials)
Water friendly layer
(Silicon+water-friendly material +anti-corrosions)
Indoor machine heat exchanger Aluminum foil pin
Ticks in the blankets
Sofa ticks
Carpet ticks
Pet's ticks
Threatens the indoor air environment.
Samsung Electronics 2-19
Product Specifications
Quiet operation of the indoor machine
SUPER FJM's indoor machine has a minimum noise level of 21 decibels. Even in the late, quiet night, you can hardly hear any noise.
Quiet night
SUPER FJM's outdoor machine can be set to quiet nighttime operation mode. The outdoor machine executes quiet operation (sleeping mode)
after six hours. After 12 hours, it returns to the previous mode automatically.
Hearing test room Library room Office room Convention hall Crowded streets
Environment load
change curves
Max temperature
Temperature change curve
Decibels
Noise change curve
(sleeping mode)
SIMPLE DESIGN AND INSTALLATION
Long pipe
The SUPER FJM indoor/outdoor machine's pipe length is a max. of 70 meters. The max. drop height between the indoor and the outdoor machines is 30 meters. (If the outdoor machine is located below the indoor machine, it is 25 meters). The max. pipe length after installation of the first branch pipe is 40 meters.
After 6 hours
1 hour of quiet operation
Start Stop
The SUPER FJM design supports simple installation. The outdoor and indoor machines use a copper pipe and a branch pipe string in parallel connection. They are provided with electricity independently.
Bedroom
Bedroom
Max outdoor/indoor drop heights 30m
Max actual pipe length 70m
Max drop heights between the indoor machines 15m
(Caution: The max. pipe length for the 3HP model is 45 meters. The max. indoor/outdoor drop height is 15 meters and the max. drop heights between the indoor machines is 7.5 meters. The max. pipe length after installation of the first branch pipe is 30 meters.)
Bedroom
Kitchen
Livingroom
Bedroom
Limitations of the operational current classes
SUPER FJM's indoor/outdoor machine control circuit board uses four types of current limits mode. It can be efficiently installed in an area with
a shortage of electrical stability. If it is to be remodeled for an old building that does not meet the electricity capacity standard, first install an air conditioner for testing. Then set the current after expanding the electricity capacity.
Current limit mode DIP button DIP button
Mode 1 ON ON Mode 2 ON OFF Mode 3 OFF ON Mode 4 OFF OFF
2-20 Samsung Electronics
Product Specifications
PROHIBITION
Independent smart central control
Independent controllers are installed in each indoor machine of SUPER FJM. Using the central controller, it can control all the indoor machines at home. When leaving home, use the central controller installed in the living room to turn off all the air conditioners. You can prevent unnecessary power consumption caused by the air conditioner running with no one at home.
Smart group control for multiple households
SUPER FJM supports group controls in conjunction with Samsung's other commercial air conditioners. It achieves a wide range of smart control
including individual metering for each household, computer monitoring and network monitoring.
Ethernet
SUPER FJM with smart control uses the smart network control method for management and support simple controls.
ON/OFF central controller
Bedroom
Kitchen
Livingroom
Bedroom
Connection
Functional central controller
SPEEDY TROUBLESHOOTING
that support speedy troubleshooting.
Self diagnosis of malfunctions
SUPER FJM is designed to perform perfect smart self diagnosis functions
The SUPER FJM indoor/outdoor machines has an LED monitor where you can quickly diagnose the operational variables and repair them
Control parts Malfunction codes
LED display of the control panel
of the outdoor machine
Codes Causes for malfunction
Communication failures between the indoor
E101
machine and the outdoor machine Bad power connection between the indoor and
E460
the outdoor machines
E467 Bad operation of the compressor E466 Inadequate voltage supply
Auto recovery of the coolant
SUPER FJM is designed to support the saving function that recovers the coolant automatically for the user. Depending on which outdoor or
indoor machine is being repaired, it decides which machine to recover the coolant from. This way, the amount of coolant can be saved.
Repaired indoor machine Repaired outdoor machine
Samsung Electronics 2-21
Product Specifications
2-1-2 Changes in comparison to basic model
Q
RVXVHT075/100/125FE, RD075/100/125VHXFA, RD075/100/125VRXFA
Changed part Changed item and feature Basic After changed
Compressor DVI compressor
Intercooler Turbo intercooler (Shell & Tube type)
Heat Exchanger New G-Fin
Fan Guard Fan Guard has been optimized to improve
Efficient and reliable DVI(Digital Vapor Injection) compressor coupled with Vapor Injection technology has been applied to improve cooling and heating performance and energy efficiency.
improves cooling and heating COP and secures reliable operation of installation with long piping (200m).
Highly efficient new G-Fin increased heat transfer performance, reinforced corrosion resistance, and increased operating duration in frost condition.
air volume and reduce noise and vibration.
Service Valve Ball type service valve applied
MAIN PCB Expanded MICOM capacity, improved
SUB PCB Redesigned Power circuit, improved
o easy to operate
serviceability
assembly
2-22 Samsung Electronics
Q
RD040/050MHXCA
Changed part Changed item and feature Basic After changed
Guard Fan Guard Fan P/D t M/D Changed(New Mold)
Improved trouble caused by rust development and reduced noise by increasing air volume
Motor Bracket Secured larger opening for improved air flow
Product Specifications
Compressor Digital Scroll t Twin BLDC Inverter
Control
Felt Double layerd felt reduces noice
from compressor
Samsung Electronics 2-23
2-2 Product Specifications
2-2-1 Indoor Unit
Q
Slim 1 way cassette type
Model AVXCSH023CE/ND0231HXCA AVXCSH032CE / ND0321HXCA AVXCSH040CE/ND0401HXCA
Power Supply
*1)
Mode
*2)
Cooling
Performance
Power
Noise Level Actual Noise Pressure (High)
Fan
Fan Speed
Airflow Rate
Refrigerant
Temperature Control - Micom&Thermistors Micom&Thermistors Micom&Thermistors Safety Devices - Fuse Fuse Fuse
Option Code
Piping Connections
Weight
Dimensions
Panel Size
Capacity
Condensate (with High fan speed) /h - - ­Input Consumption (Cooling/Heating) W 40/40 45/45 50/50 Running Current (Cooling/Heating) A 0.2/0.2 0.23/0.23 0.25/0.25
Type - Cross flow fan Cross flow fan Cross flow fan
Motor
The progress of work(H/M/L) Cooling (H/M/L) 930/860/790 1,035/913/790 1,245/1,105/965 Heating (H/M/L) 1,035/965/895 1,140/1,018/895 1,245/1,105/965 Cooling (High) Heating (High) 7.0 8.0 9.0 Cooling (High) Heating (High) 247 283 318
External Static Pressure
Type - R410a R410a R410a Control Method - EEV EEV EEV
AVXCSH666CE -
ND6661HXCA -
Liquid (Flare)
Gas (Flare)
Drain (Quick Lock)
Net Weight
Shipping Weight
Net Dimensions (W×H×D)
Shipping Dimensions (W×H×D)
Model - PSSMA PSSMA PSSMA
Net Weight
Shipping Weight
Net Dimensions (W×H×D)
Shipping Dimensions (W×H×D)
*3)
Heating
*4)
Model - SFN-220-20-4B-1 SFN-220-20-4B-1 SFN-220-20-4B-1 Type - Non Feedback SSR Non Feedback SSR Non Feedback SSR Output W 20 20 20
Standard(Min.~Max) mmH2O - - ­Standard(Min.~Max) WG - - -
Ø,V,Hz 1,208~230,60 1,208~230,60 1,208~230,60
HP / HR HP / HR HP / HR
kW 2.3 3.2 4.0
Btu/h 7,500 9,500 12,000
kW 2.6 3.6 4.5
Btu/h 8,500 10,500 13,500
dB(A) 34 37 40
---
rpm
/min
CFM
Ø,mm 6.35 6.35 6.35 Ø,inch 1/4" 1/4" 1/4" Ø,mm 12.70 12.70 12.70 Ø,inch 1/2" 1/2" 1/2" Ø,mm ID 18 hose ID 18 hose ID 18 hose Ø,inch - - -
kg 10.5 10.5 10.5
lbs 23.0 23.0 23.0
kg 13.5 13.5 13.5
lbs 30.0 30.0 30.0 mm 970x135x410 970x135x410 970x135x410 inch 38.2x5.3x16.1 38.2x5.3x16.1 38.2x5.3x16.1 mm 1,164x212x478 1,164x212x478 1,164x212x478 inch 45.8x8.3x18.8 45.8x8.3x18.8 45.8x8.3x18.8
kg 3.0 3.0 3.0
lbs 6.6 6.6 6.6
kg 5.0 5.0 5.0
lbs 11.0 11.0 11.0 mm inch 46.5×1.0×18.1 46.5×1.0×18.1 46.5×1.0×18.1 mm inch 49.6×5.7×21.2 49.6×5.7×21.2 49.6×5.7×21.2
6.0 7.0 8.0
212 247 283
078605-1260C8 200001-300000
078605-1260C8 200000-300000
1,180×25×460 1,180×25×460 1,180×25×460
1,259×144×539 1,259×144×539 1,259×144×539
078605-1460F8 200001-300000
078605-1460F8 200000-300000
075605-16625D 200001-300000
075605-16625D 200000-300000
2-24 Samsung Electronics
Indoor Unit(cont.)
Slim 1 way cassette type(cont.)
Model AVXCMH032CE/ND032MHXCA AVXCMH040CE/ND040MHXCA AVXCMH052CE/ND052MHXCA
Auto Restart - O O O Auto Swing - O O O
Functions
Standard Accessories
Optional Accessories
Group/Individual Control - O O O External Contact Control - O O O Trouble Shooting by LED - O O O Installation Manual - O O O Operation Manual - X X X Pattern Sheet for Installation - O O O Flexible Drain Hose - O O O Filter / Safety Grille - Filter / Safety Grille Filter / Safety Grille Filter / Safety Grille Drain Pump (Pumping speed, lift) /h,mm 24, 750 24, 750 24, 750
Wireless Remote Controller
Wired Remote Controller
External Contact Interface Module - MIM-B14 MIM-B14 MIM-B14
AVXCSH666CE - MR-BH01U MR-BH01U MR-BH01U
ND
6661HXCA MR-BH01 MR-BH01 MR-BH01
Simplified - MWR-SH00 MWR-SH00 MWR-SH00 Multi Function - MWR-WE00 MWR-WE00 MWR-WE00 Premium - MWR-WS01 MWR-WS01 MWR-WS01
Product Specifications
*1) Mode
- HP : Heat Pump *2) Norminal cooling capacities are based on;
- Indoor temperature : 81˚F/27˚C DB, 66 ˚F/19˚C WB
- Outdoor temperature : 95˚F/35˚C DB, 75˚F/24˚C WB
*3) Norminal heating capacities are based on;
- Indoor temperature : 70˚F/20˚C DB, 60˚F/15˚C WB
- Outdoor temperature : 47˚F/7˚C DB, 43˚F/6˚C WB *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications may be subject to change without prior notice for product improvement.
Samsung Electronics 2-25
Product Specifications
Indoor Unit(cont.)
Q
Mini 4 way cassette type
Model
Power Supply Ø,V,Hz 1,208~230,60 1,208~230,60 1,208~230,60 1,208~230,60
*1)
Mode
*2)
Cooling
Performance
Power
Noise Level Actual Noise Pressure (High)
Fan
Fan Speed
Airflow Rate
Refrigerant
Temperature Control - Micom&Thermistors Micom&Thermistors Micom&Thermistors Micom&Thermistors Safety Devices - Fuse Fuse Fuse Fuse
Option Code
Piping Connections
Weight
Dimensions
Panel Size
Capacity
Condensate (with High fan speed) /h - - - ­Input Consumption (Cooling/Heating) W 110 / 110 110 / 110 110 / 110 110 / 110 Running Current (Cooling/Heating) A 0.47 / 0.47 0.47 / 0.47 0.47 / 0.47 0.50 / 0.50
Type - Turbo Fan (Ø320) Turbo Fan (Ø320) Turbo Fan (Ø320) Turbo Fan (Ø320)
Motor
The progress of work(H/M/L) Cooling (H/M/L) 745/690/620 745/690/620 760/700/631 820/700/601 Heating (H/M/L) 745/690/620 745/690/620 760/700/632 820/700/602 Cooling (High) Heating (High) 12.0 12.0 14.5 15.5 Cooling (High) Heating (High) 424 424 512 547
External Static Pressure
Type - R410a R410a R410a R410a Control Method - EEV EEV EEV EEV
AVXCMH666CE
ND666MHXCA -
Liquid (Flare)
Gas (Flare)
Drain (Quick Lock)
Net Weight
Shipping Weight
Net Dimensions (W×H×D)
Shipping Dimensions (W×H×D)
Model - PMSMAA PMSMAA PMSMAA PMSMAA
Net Weight
Shipping Weight
Net Dimensions (W×H×D)
Shipping Dimensions (W×H×D)
*3)
Heating
*4)
Model - ASS035ZTEJ ASS035ZTEJ ASS035ZTEJ ASS035ZTEJ Type - Non Feedback SSR Non Feedback SSR Non Feedback SSR Non Feedback SSR Output W 55
Standard(Min.~Max) mmH2O - - - ­Standard(Min.~Max) WG - - - -
Btu/h 9,500 12,000 18,000 20,000
Btu/h 10,500 13,500 20,000 23,000
dB(A) 46 / 46 46 / 46 47 / 47 48 / 48
rpm
m³/min
CFM
Ø,mm 6.35 6.35 6.35 6.35 Ø,inch 1/4" 1/4" 1/4" 1/4" Ø,mm 12.70 12.70 12.70 12.70 Ø,inch 1/2" 1/2" 1/2" 1/2" Ø,mm VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) Ø,inch VP25 (OD 1 1/4",ID 1") VP25 (OD 1 1/4",ID 1") VP25 (OD 1 1/4",ID 1") VP25 (OD 1 1/4",ID 1")
mm 575×260×575 575×260×575 575×260×575 575×260×575 inch 22.6×10.2×22.6 22.6×10.2×22.6 22.6×10.2×22.6 22.6×10.2×22.6 mm 660×310×635 660×310×635 660×310×635 660×310×635 inch 26×12.2×25 26×12.2×25 26×12.2×25 26×12.2×25
mm 670×35×670 670×35×670 670×35×670 670×35×670 inch 26.3×1.4×26.3 26.3×1.4×26.3 26.3×1.4×26.3 26.3×1.4×26.3 mm 717×93×717 717×93×717 717×93×717 717×93×717 inch 28.2×3.7×28.2 28.2×3.7×28.2 28.2×3.7×28.2 28.2×3.7×28.2
AVXCMH032CE/
ND032MHXCA
HP / HR HP / HR HP / HR HP / HR
kW 3.2 4.0 5.2 6.0
kW 3.6 4.5 6.0 6.8
*5)
745/690/620 745/690/620 760/700/630 820/700/600
11.0 11.0 13.5 14.5
388 388 477 512
045224-1540B3
-
-200000-300000
kg 17.0 17.0 17.0 17.0 lbs 37.5 37.5 37.5 37.5 kg 20.0 20.0 20.0 20.0 lbs 44.1 44.1 44.1 44.1
kg 3.5 3.5 3.5 3.5 lbs 7.7 7.7 7.7 7.7 kg 6.2 6.2 6.2 6.2 lbs 13.7 13.7 13.7 13.7
AVXCMH040CE/
ND040MHXCA
*5)
55
045224-1840B3
-200001-300000
AVXCMH052CE/
ND052MHXCA
*5)
55
045224-1B40B3
-200001-300000
AVXCMH060CE/
ND060MHXCA
*5)
55
045224-1C40F1
-200001-300000
2-26 Samsung Electronics
Indoor Unit(cont.)
Mini 4 way cassette type(cont.)
Product Specifications
Functions
Standard Accessories
Optional Accessories
Model
Auto Restart - OOOO Auto Swing - OOOO Group/Individual Control - OOOO External Contact Control - OOOO Trouble Shooting by LED - OOOO Installation Manual - OOOO Operation Manual - XXXX Pattern Sheet for Installation - OOOO Flexible Drain Hose - OOOO Filter / Safety Grille - Filter / Safety Grille Filter / Safety Grille Filter / Safety Grille Filter / Safety Grille Drain Pump (Pumping speed, lift) /h,mm 24, 750 24, 750 24, 750 24, 750
Wireless Remote Controller
Wired Remote Controller
External Contact Interface Module - MIM-B14 MIM-B14 MIM-B14 MIM-B14
AVXCMH666CE - MR-BH01U MR-BH01U MR-BH01U MR-BH01U ND666MHXCA - MR-BH01 MR-BH01 MR-BH01 MR-BH01
Simplified - MWR-SH00 MWR-SH00 MWR-SH00 MWR-SH00 Multi Function - MWR-WE00 MWR-WE00 MWR-WE00 MWR-WE00 Premium - MWR-WS01 MWR-WS01 MWR-WS01 MWR-WS01
AVXCMH032CE/
ND032MHXCA
AVXCMH040CE/
ND040MHXCA
AVXCMH052CE/
ND052MHXCA
AVXCMH060CE/
ND060MHXCA
*1) Mode
- HP : Heat Pump *2) Norminal cooling capacities are based on;
- Indoor temperature : 81˚F/27˚C DB, 66˚F/19˚C WB
- Outdoor temperature : 95˚F/35˚C DB, 75˚F/24˚C WB
*3) Norminal heating capacities are based on;
- Indoor temperature : 70˚F/20˚C DB, 60˚F/15˚C WB
- Outdoor temperature : 47˚F/7˚C DB, 43˚F/6˚C WB *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications may be subject to change without prior notice for product improvement.
Samsung Electronics 2-27
Product Specifications
Indoor Unit(cont.)
4 way cassette type
Model
Power Supply Ø,V,Hz 1,208~230,60 1,208~230,60 1,208~230,60 1,208~230,60 1,208~230,60
*1)
Mode
*2)
Cooling
Performance
Power
Noise Level Actual Noise Pressure (High)
Fan
Fan Speed
Airflow Rate
Refrigerant
Temperature Control - Micom&Thermistors Micom&Thermistors Micom&Thermistors Micom&Thermistors Micom&Thermistors Safety Devices - Fuse Fuse Fuse Fuse Fuse
Option Code
Piping Connections
Weight
Dimensions
Panel Size
Capacity
Condensate (with High fan speed) /h 2.71 3.51 5.58 5.58 7.18 Input Consumption (Cooling/Heating) W 40 / 40 45 / 45 50 / 50 50 / 50 80 / 80 Running Current (Cooling/Heating) A 0.19 / 0.19 0.21 / 0.21 0.23 / 0.23 0.23 / 0.23 0.36 / 0.36
Type - Turbo Fan Turbo Fan Turbo Fan Turbo Fan Turbo Fan
Motor
The progress of work(H/M/L) Cooling (H/M/L) 440/400/360 500/440/380 520/470/420 560/520/480 600/560/520 Heating (H/M/L) 400/360/320 460/400/340 520/470/420 560/520/480 640/600/560 Cooling (High) Heating (High) 16.5 18.5 26.5 29.5 32.0 Cooling (High) Heating (High) 583 653 936 1,042 1,130
External Static Pressure
Type - R410a R410a R410a R410a R410a Control Method - EEV EEV EEV EEV EEV
AVXC4H666CE
ND6664HXCA -
Liquid (Flare)
Gas (Flare)
Drain (Quick Lock)
Net Weight
Shipping Weight
Net Dimensions (W×H×D)
Shipping Dimensions (W×H×D)
Model - P4SMA P4SMA P4SMA P4SMA P4SMA
Net Weight
Shipping Weight
Net Dimensions (W×H×D)
Shipping Dimensions (W×H×D)
*3)
Heating
*4)
Model - SIC-67FV-F135-1 SIC-67FV-F135-1 SPG DL-95835SSIA SPG DL-95835SSIA SPG DL-95835SSIA Type - BLDC BLDC BLDC BLDC BLDC Output W - - - - -
m³/min
Standard(Min.~Max) Standard(Min.~Max)
mmH2O - - - - -
AVXC4H052CE/
ND0524HXCA
HP / HR HP / HR HP / HR HP / HR HP / HR
kW 5.2 7.2 10.0 11.0 14.5
Btu/h 18,000 24,000 30,000 36,000 48,000
kW 6.0 8.1 11.0 12.8 16.3
Btu/h 20,000 27,000 34,000 40,000 54,000
dB(A) 43 / 44 43 / 44 46 / 46 46 / 46 51 / 52
-----
rpm
14.5 17.0 23.0 25.0 26.5
CFM
WG-----
-
Ø,mm 6.35 9.52 9.52 9.52 9.52 Ø,inch 1/4" 3/8" 3/8" 3/8" 3/8" Ø,mm 12.70 15.88 15.88 15.88 15.88 Ø,inch 1/2" 5/8" 5/8" 5/8" 5/8" Ø,mm VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) Ø,inch
kg 25.0 25.0 29.0 29.0 29.0
lbs 55.1 55.1 63.9 63.9 63.9
kg 31.0 31.0 35.0 35.0 35.0
lbs 68.3 68.3 77.2 77.2 77.2 mm 840×218×840 840×218×840 840×298×840 840×298×840 840×298×840 inch 33.1×8.6×33.1 33.1×8.6×33.1 33.1×11.7×33.1 33.1×11.7×33.1 33.1×11.7×33.1 mm 925×280×925 925×280×925 925×360×925 925×360×925 925×360×925 inch 36.4×11×36.4 36.4×11×36.4 36.4×14.2×36.4 36.4×14.2×36.4 36.4×14.2×36.4
kg 7.0 7.0 7.0 7.0 7.0
lbs-----
kg 10.3 10.3 10.3 10.3 10.3
lbs----­mm 950×35×950 950×35×950 950×35×950 950×35×950 950×35×950 inch 37.4×1.4×37.4 37.4×1.4×37.4 37.4×1.4×37.4 37.4×1.4×37.4 37.4×1.4×37.4 mm 1,042×103×1,042 1,042×103×1,042 1,042×103×1,042 1,042×103×1,042 1,042×103×1,042 inch 41×4.1×41 41×4.1×41 41×4.1×41 41×4.1×41 41×4.1×41
512 600 812 883 936
043217-1B00C8
200001-300000
043217-1B00C8
200000-300000
VP25 (OD 1 1/4",ID 1") VP25 (OD 1 1/4",ID 1") VP25 (OD 1 1/4",ID 1") VP25 (OD 1 1/4",ID 1") VP25 (OD 1 1/4",ID 1")
AVXC4H072CE/
ND0724HXCA
043217-1D00F9
200001-300000
043217-1D00F9
200000-300000
AVXC4H100CE/
ND1004HXCA
045A17-10020B 200001-300000
045A17-10020B 200000-300000
AVXC4H110CE/
ND1104HXCA
045A17-12022E
200001-300000
045A17-12022E
200000-300000
AVXC4H145CE/
ND1454HXCA
047A17-130340 200001-300000
047A17-130340 200000-300000
2-28 Samsung Electronics
Indoor Unit(cont.)
4 way cassette type(cont.)
Product Specifications
Functions
Standard Accessories
Optional Accessories
Model
Auto Restart - O O O O O Auto Swing - O O O O O Group/Individual Control - O O O O O External Contact Control - O O O O O Trouble Shooting by LED - O O O O O Installation Manual - O O O O O Operation Manual - X X X X X Pattern Sheet for Installation - O O O O O Flexible Drain Hose - O O O O O Filter / Safety Grille - Filter / Safety Grille Filter / Safety Grille Filter / Safety Grille Filter / Safety Grille Filter / Safety Grille Drain Pump (Pumping speed, lift) /h,mm 24, 750 24, 750 24, 750 24, 750 24, 750
Wireless Remote Controller
Wired Remote Controller
External Contact Interface Module - MIM-B14 MIM-B14 MIM-B14 MIM-B14 MIM-B14
AVXC4H666CE - MR-BH01U MR-BH01U MR-BH01U MR-BH01U MR-BH01U ND6664HXCA - MR-BH01 MR-BH01 MR-BH01 MR-BH01 MR-BH01
Simplified - MWR-SH00 MWR-SH00 MWR-SH00 MWR-SH00 MWR-SH00 Multi Function - MWR-WE00 MWR-WE00 MWR-WE00 MWR-WE00 MWR-WE00 Premium - MWR-WS01 MWR-WS01 MWR-WS01 MWR-WS01 MWR-WS01
AVXC4H052CE/
ND0524HXCA
AVXC4H072CE/
ND0724HXCA
AVXC4H100CE/
ND1004HXCA
AVXC4H110CE/
ND1104HXCA
AVXC4H145CE/
ND1454HXCA
*1) Mode
- HP : Heat Pump *2) Norminal cooling capacities are based on;
- Indoor temperature : 81˚F/27˚C DB, 66˚F/19˚C WB
- Outdoor temperature : 95˚F/35˚C DB, 75˚F/24˚C WB
*3) Norminal heating capacities are based on;
- Indoor temperature : 70˚F/20˚C DB, 60˚F/15˚C WB
- Outdoor temperature : 47˚F/7˚C DB, 43˚F/6˚C WB *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications may be subject to change without prior notice for product improvement.
Samsung Electronics 2-29
Product Specifications
Indoor Unit(cont.)
Global 4 way cassette
Model ND0524HXCB ND0724HXCB ND1004HXCB ND1104HXCB ND1454HXCB
Power Supply Ø,V,Hz 1,208~230,60 1,208~230,60 1,208~230,60 1,208~230,60 1,208~230,60
*1)
Mode
*2)
Cooling
Performance
Power
Noise Level Actual Noise Pressure (High)
Fan
Fan Speed
Airflow Rate
Refrigerant
Temperature Control - Micom&Thermistors Micom&Thermistors M icom&Thermistors Micom&Thermistors Micom&Thermistors Safety Devices - Fuse Fuse Fuse Fuse Fuse
Option Code AVXC4H666CE -
Piping Connections
Weight
Dimensions
Panel Size
Capacity
Condensate (with High fan speed) /h ----­Input Consumption (Cooling/Heating) W 32/32 40/40 32/32 69/69 89/89 Running Current (Cooling/Heating) A 0.15/0.15 0.20/0.20 0.15/0.15 0.33/0.33 0.45/0.45
Type - Turbo Fan Turbo Fan Turbo Fan Turbo Fan Turbo Fan
Motor
The progress of work(H/M/L) Cooling (H/M/L) 360/320/300 440/390/340 540/460/380 540/480/420 600/550/500 Heating (H/M/L) 340/300/280 440/390/340 540/460/380 540/480/420 600/550/500 Cooling (High) Heating (High) 17.5 19.5 22.0 28.0 33.0 Cooling (High) Heating (High) 618 689 777 989 1,165
External Static Pressure
Type - R410a R410a R410a R410a R410a Control Method - EEV EEV EEV EEV EEV
Liquid (Flare)
Gas (Flare)
Drain (Quick Lock)
Net Weight
Shipping Weight
Net Dimensions (W×H×D)
Shipping Dimensions (W×H×D)
Model - PC4NUSKA PC4NUSKA PC4NUSKA PC4NUSKA PC4NUSKA
Net Weight
Shipping Weight
Net Dimensions (W×H×D)
Shipping Dimensions (W×H×D)
*3)
Heating
*4)
Model - FMC6531SSH FMC6531SSH FMC6531SSH FMC6531SSF DAI33585ZLB Type - BLDC BLDC BLDC BLDC BLDC Output W - - - - -
Standard(Min.~Max) Standard(Min.~Max)
kW 5.2 7.2 10.0 11.0 14.5
Btu/h 18,000 24,000 30,000 36,000 48,000
kW 6.0 8.1 11.0 12.8 16.3
Btu/h 20,000 27,000 34,000 40,000 54,000
dB(A) 42/44 43 / 44 48/49 49/49 53/53
rpm
m³/min
CFM
mmH2O - - - - -
WG-----
Ø,mm 6.35 9.52 9.52 9.52 9.52 Ø,inch 1/4" 3/8" 3/8" 3/8" 3/8" Ø,mm 12.70 15.88 15.88 15.88 15.88 Ø,inch 1/2" 5/8" 5/8" 5/8" 5/8" Ø,mm VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) Ø,inch
kg 15.5 15.5 15.5 17.0 19.0
lbs 34.2 34.2 34.2 37.5 41.9
kg 19.5 19.5 19.5 22.0 24.0
lbs 43 43 43 48.5 52.9 mm 840x204x840 840x204x840 840x204x840 840x246x840 840x288x840 inch 33.1x8.0x33.1 33.1x8.0x33.1 33.1x8.0x33.1 33.1x9.7x33.1 33.1x11.3x33.1 mm 898x275x898 898x275x898 898x275x898 898x316x898 898x357x898 inch 35.4x10.8x35.4 35.4x10.8x35.4 35.4x10.8x35.4 35.4x12.4x35.4 35.4x14.0x35.4
kg 6.7 6.7 6.7 6.7 6.7
lbs-----
kg 8.9 8.9 8.9 8.9 8.9
lbs----­mm 950x30x950 950x30x950 950x30x950 950x30x950 950x30x950 inch 37.4x1.2x37.4 37.4x1.2x37.4 37.4x1.2x37.4 37.4x1.2x37.4 37.4x1.2x37.4 mm 1,042×93×1,042 1,042×93×1,042 1,042×93×1,042 1,042×93×1,042 1,042×93×1,042 inch 41.0×3.7×41.0 41.0×3.7×41.0 41.0×3.7×41.0 41.0×3.7×41.0 41.0×3.7×41.0
HP / HR HP / HR HP / HR HP / HR HP / HR
-----
15.5 17.5 19.5 24.0 29.0
547 618 689 848 1,024
01407F 156097 233434 300008 020010 100000 200000 300000 030000 100000 200000 300000
VP25 (OD 1 1/4",ID 1") VP25 (OD 1 1/4",ID 1") VP25 (OD 1 1/4",ID 1") VP25 (OD 1 1/4",ID 1") VP25 (OD 1 1/4",ID 1")
01407F 1560C7 234848 300008 020010 100000 200000 300000 030000 100000 200000 300000
01407F 156219 236464 300008 020010 100000 200000 300000 030000 100000 200000 300000
01407F 15621B 236E6E 300028 020010 100000 200000 300000 030000 100000 200000 300000
01407F 15624F 239191 300048 020010 100000 200000 300000 030000 100000 200000 300000
2-30 Samsung Electronics
Indoor Unit(cont.)
Global 4 way cassette(cont.)
Model ND0524HXCB ND0724HXCB ND1004HXCB ND1104HXCB ND1454HXCB
Auto Restart - O O O O O Auto Swing - O O O O O
Functions
Standard Accessories
Optional Accessories
Group/Individual Control - O O O O O External Contact Control - O O O O O Trouble Shooting by LED - O O O O O Installation Manual - O O O O O Operation Manual - X X X X X Pattern Sheet for Installation - O O O O O Flexible Drain Hose - O O O O O Filter / Safety Grille - Filter / Safety Grille Filter / Safety Grille Filter / Safety Grille Filter / Safety Grille Filter / Safety Grille Drain Pump (Pumping speed, lift) /h,mm 24, 750 24, 750 24, 750 24, 750 24, 750
Wireless Remote Controller
Wired Remote Controller
External Contact Interface Module - MIM-B14 MIM-B14 MIM-B14 MIM-B14 MIM-B14
AVXC4H666CE - MR-BH01U MR-BH01U MR-BH01U MR-BH01U MR-BH01U ND6664HXCA - MR-BH01 MR-BH01 MR-BH01 MR-BH01 MR-BH01
Simplified - MWR-SH00 MWR-SH00 MWR-SH00 MWR-SH00 MWR-SH00 Multi Function - MWR-WE00 MWR-WE00 MWR-WE00 MWR-WE00 MWR-WE00 Premium - MWR-WS01 MWR-WS01 MWR-WS01 MWR-WS01 MWR-WS01
Product Specifications
*1) Mode
- HP : Heat Pump *2) Norminal cooling capacities are based on;
- Indoor temperature : 81˚F/27˚C DB, 66˚F/19˚C WB
- Outdoor temperature : 95˚F/35˚C DB, 75˚F/24˚C WB
*3) Norminal heating capacities are based on;
- Indoor temperature : 70˚F/20˚C DB, 60˚F/15˚C WB
- Outdoor temperature : 47˚F/7˚C DB, 43˚F/6˚C WB *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications may be subject to change without prior notice for product improvement.
Samsung Electronics 2-31
Product Specifications
Indoor Unit(cont.)
Slim duct type
Model
Power Supply Ø,V,Hz 1,208~230,60 1,208~230,60 1,208~230,60 1,208~230,60
*1)
Mode
*2)
Cooling
Performance
Power
Noise Level Actual Noise Pressure (High)
Fan
Fan Speed
Airflow Rate
Refrigerant
Temperature Control - Micom&Thermistors Micom&Thermistors Micom&Thermistors Micom&Thermistors Safety Devices - Fuse Fuse Fuse Fuse
Option Code
Piping Connections
Weight
Dimensions
Panel Size
Capacity
Condensate (with High fan speed) /h - - - ­Input Consumption (Cooling/Heating) Running Current (Cooling/Heating) A 0.32 / 0.32 0.34 / 0.34 0.35 / 0.35 0.65 / 0.65
Type - Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan
Motor
The progress of work(H/M/L) Cooling (H/M/L) 920/840/740 1,040/960/830 1,060/990/870 1,220/1,048/916 Heating (H/M/L) 920/840/740 1,040/960/830 1,060/990/870 1,220/1,048/916 Cooling (High) Heating (High) 9.0 12.0 13.0 16.5 Cooling (High) Heating (High) 318 424 459 583
External Static Pressure
Type - R410a R410a R410a R410a Control Method - EEV EEV EEV EEV
AVXDSH666CE -
ND666LHXCA -
Liquid (Flare)
Gas (Flare)
Drain (Quick Lock)
Net Weight
Shipping Weight
Net Dimensions (W×H×D)
Shipping Dimensions (W×H×D)
Model - - - - -
Net Weight
Shipping Weight
Net Dimensions (W×H×D)
Shipping Dimensions (W×H×D)
*3)
Heating
*4)
Model - YSK110-25-6SN YSK110-25-6SN YSK110-25-6SN YSK140-60-4B-1 Type - Non Feedback SSR Non Feedback SSR Non Feedback SSR Non Feedback SSR Output W - - - -
Standard(Min.~Max) Standard(Min.~Max)
kW 2.0 3.2 4.0 5.2
Btu/h 6,000 7,500 12,000 18,000
kW 2.3 3.6 4.5 6.0
Btu/h 7,000 8,500 13,500 20,000
dB(A) 37 / 38 37 / 38 37 / 38 45 / 45
rpm
m³/min
CFM
mmH2O 2 (0~4) 2 (0~4) 2 (0~4) 2 (0~4)
WG 0.08 (0~0.16) 0.08 (0~0.16) 0.08 (0~0.16) 0.08 (0~0.16)
Ø,mm 6.35 6.35 6.35 6.35 Ø,inch 1/4" 1/4" 1/4" 1/4" Ø,mm 12.70 12.70 12.70 12.70 Ø,inch 1/2" 1/2" 1/2" 1/2" Ø,mm VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) Ø,inch VP25 (OD 1 1/4",ID 1") VP25 (OD 1 1/4",ID 1") VP25 (OD 1 1/4",ID 1") VP25 (OD 1 1/4",ID 1")
kg 26.0 26.0 26.0 31.0 lbs 57.3 57.3 57.3 68.3 kg 31.0 31.0 31.0 39.0 lbs 68.3 68.3 68.3 86.0
mm 900×199×600 900×199×600 900×199×600 1100×199×600
inch 35.4×7.8×23.6 35.4×7.8×23.6 35.4×7.8×23.6 43.3×7.8×23.6
mm 1,133×330×730 1,133×330×730 1,133×330×730 1,330×330×730
inch 44.6×13×28.7 44.6×13×28.7 44.6×13×28.7 52.4×13×28.7
kg---­lbs---­kg---­lbs----
mm----
inch - - - -
mm----
inch - - - -
AVXDSH020CE/
ND020LHXCA
- HP / HR HP / HR HP / HR HP / HR
W 47 / 47 60 / 60 75 / 75 110 / 110
702/560/451 988/839/571 1,008/852/616 1,115/907/739
8.0 10.0 12.0 14.5
282 353 424 512
015221-1103D1
-200001-300000
015221-1103D1
-200000-300000
AVXDSH032CE/
ND032LHXCA
015223-1401B6
-200001-300000
015223-1401B6
-200000-300000
AVXDSH040CE/
ND040LHXCA
015223-160329
-200001-300000
015223-160329
-200000-300000
AVXDSH052CE/
ND052LHXCA
015223-1901ED
-200001-300000
015223-1901ED
-200000-300000
2-32 Samsung Electronics
Indoor Unit(cont.)
Slim duct type(cont.)
Product Specifications
Functions
Standard Accessories
Optional Accessories
Model
Auto Restart - O O O O Auto Swing - X X X X Group/Individual Control - O O O O External Contact Control - O O O O Trouble Shooting by LED - X X X X Installation Manual - O O O O Operation Manual - O O O O Pattern Sheet for Installation - X X X X Flexible Drain Hose - O O O O Filter / Safety Grille - Filter (Washable) Filter (Washable) Filter (Washable) Filter ( Washable) Drain Pump (Pumping speed, lift) /h,mm 24, 750 24, 750 24, 750 24, 750
Wireless Remote Controller
Wired Remote Controller
External Contact Interface Module - MIM-B14 MIM-B14 MIM-B14 MIM-B14 Drain Pump - MDP-E075SEE MDP-E075SEE MDP-E075SEE MDP-E075SEE
Remote Controller Receiver Kit(Duct)
Remote Controller Receiver Wire(Duct)
AVXDSH666CE - MR-BH01U MR-BH01U MR-BH01U MR-BH01U ND666LHXCA - MR-BH01 MR-BH01 MR-BH01 MR-BH01
Simplified - MWR-SH00 MWR-SH00 MWR-SH00 MWR-SH00 Multi Function - MWR-WE00 MWR-WE00 MWR-WE00 MWR-WE00 Premium - MWR-WS01 MWR-WS01 MWR-WS01 MWR-WS01
AVXDSH020CE/
ND020LHXCA
- MRK-A00 MRK-A00 MRK-A00 MRK-A00
- MR W-10A MRW-10A MRW-10A MRW-10A
AVXDSH032CE/
ND032LHXCA
AVXDSH040CE/
ND040LHXCA
AVXDSH052CE/
ND052LHXCA
*1) Mode
- HP : Heat Pump *2) Norminal cooling capacities are based on;
- Indoor temperature : 81˚F/27˚C DB, 66˚F/19˚C WB
- Outdoor temperature : 95˚F/35˚C DB, 75˚F/24˚C WB
*3) Norminal heating capacities are based on;
- Indoor temperature : 70˚F/20˚C DB, 60˚F/15˚C WB
- Outdoor temperature : 47˚F/7˚C DB, 43˚F/6˚C WB *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications may be subject to change without prior notice for product improvement.
Samsung Electronics 2-33
Product Specifications
Indoor Unit(cont.)
Slim duct type(cont.)
Model
Power Supply Ø,V,Hz 1,208~230,60 1,208~230,60 1,208~230,60 1,208~230,60
*1)
Mode
*2)
Cooling
Performance
Power
Noise Level Actual Noise Pressure (High)
Fan
Fan Speed
Airflow Rate
Refrigerant
Temperature Control - Micom&Thermistors Micom&Thermistors Micom&Thermistors Micom&Thermistors Safety Devices - Fuse Fuse Fuse Fuse
Option Code
Piping Connections
Weight
Dimensions
Panel Size
Capacity
Condensate (with High fan speed) /h - - - ­Input Consumption (Cooling/Heating) W 130 / 130 95/95 120/120 180/180 Running Current (Cooling/Heating) A 0.70 / 0.70 0.8/0.8 1.05/1.05 1.4/1.4
Type - Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan
Motor
The progress of work(H/M/L) Cooling (H/M/L) 1,350/1,139/968 950/880/810 1,020/910/830 1,160/1,000/870 Heating (H/M/L) 1,350/1,139/968 950/880/810 1,020/910/830 1,160/1,000/870 Cooling (High) Heating (High) 19.0 22.0 33.0 37.0 Cooling (High) Heating (High) 671 777 1165 1306
External Static Pressure
Type - R410a R410a R410a R410a Control Method - EEV EEV EEV EEV
AVXDSH666CE
ND666LHXCA
Liquid (Flare)
Gas (Flare)
Drain (Quick Lock)
Net Weight
Shipping Weight
Net Dimensions (W×H×D)
Shipping Dimensions (W×H×D)
Model - - - - -
Net Weight
Shipping Weight
Net Dimensions (W×H×D)
Shipping Dimensions (W×H×D)
*3)
Heating
*4)
Model - YSK140-60-4B-1 DL-12840SSBC DL-12840SSBC DL-12840SSBC Type - Non Feedback SSR BLDC BLDC BLDC Output W 183 183 183 183
Standard(Min.~Max) Standard(Min.~Max)
Btu/h 24,000 30,000 36,000 48,000
Btu/h 27,000 34,000 40,000 54,000
dB(A) 47 / 47 43 / 44 43 / 44 45 / 46
rpm
m³/min
CFM
mmH2O 2 (0~4) 3 (0~6) 3 (0~6) 3 (0~6)
Ø,mm 9.52 9.52 9.52 9.52 Ø,inch 3/8" 3/8" 3/8" 3/8" Ø,mm 15.88 15.88 15.88 15.88 Ø,inch 5/8" 5/8" 5/8" 5/8" Ø,mm VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) Ø,inch VP25 (OD 1 1/4",ID 1") VP25 (OD 1 1/4",ID 1") VP25 (OD 1 1/4",ID 1") VP25 (OD 1 1/4",ID 1")
mm 1,100×199×600 1,300×295×690 1,300×295×690 1,300×295×690 inch 43.3×7.8×23.6 51.2×11.6×27.2 51.2×11.6×27.2 51.2×11.6×27.2 mm 1,330×330×730 1,600×441×831 1,600×441×831 1,600×441×831 inch 52.4×13×28.7 63×17.4×32.7 63×17.4×32.7 63×17.4×32.7
mm---­inch - - - ­mm---­inch - - - -
AVXDSH072CE/
ND072LHXCA
- HP / HR HP / HR HP / HR HP / HR
kW 7.2 10.0 11.0 14.5
kW 8.1 11.0 12.8 16.3
1,275/1,025/785 886/817/737 945/847/758 1,075/930/801
17.0 25.0 29.0 35.0
600 883 1024 1236
WG 0.08 (0~0.16) 0.12(0~0.24) 0.12(0~0.24) 0.12(0~0.24)
015224-1C0250
-
-200001-300000
015224-1C0250
-
-200000-300000
kg 31.0 43.0 43.0 46.0 lbs 68.3 94.8 94.8 101.4 kg 39.0 51.5 51.5 54.5 lbs 86.0 113.5 113.5 120.2
kg---­lbs - - - ­kg---­lbs----
AVXDSH100CE/
ND100LHXCA
015213-1F019F 200001-300000
015213-1F019F 200000-300000
AVXDSH110CE/
ND110LHXCA
015A14-1000D0
200001-300000
015A14-1000D0
200000-300000
AVXDSH145CE/
ND145LHXCA
015A14-130263 200001-300000
015A14-130263 200000-300000
2-34 Samsung Electronics
Indoor Unit(cont.)
Slim duct type(cont.)
Product Specifications
Functions
Standard Accessories
Optional Accessories
Model
Auto Restart - OOOO Auto Swing - XXXX Group/Individual Control - OOOO External Contact Control - OOOO Trouble Shooting by LED - XXXX Installation Manual - OOOO Operation Manual - OOOO Pattern Sheet for Installation - XXXX Flexible Drain Hose - O O O O Filter / Safety Grille - Filter (Washable) Filter (Washable) Filter (Washable) Filter (Washable) Drain Pump (Pumping speed, lift) /h,mm 24, 750 24, 750 24, 750 24, 750
Wireless Remote Controller
Wired Remote Controller
External Contact Interface Module - MIM-B14 MIM-B14 MIM-B14 MIM-B14 Drain Pump - MDP-E075SEE1 MDP-E075SEE1 MDP-E075SEE1 MDP-E075SEE1
Remote Controller Receiver Kit(Duct)
Remote Controller Receiver Wire(Duct)
AVXDSH666CE - MR-BH01U MR-BH01U MR-BH01U MR-BH01U ND666LHXCA - MR-BH01 MR-BH01 MR-BH01 MR-BH01
Simplified - MWR-SH00 MWR-SH00 MWR-SH00 MWR-SH00 Multi Function - MWR-WE00 MWR-WE00 MWR-WE00 MWR-WE00 Premium - MWR-WS01 MWR-WS01 MWR-WS01 MWR-WS01
AVXDSH072CE/
ND072LHXCA
- MRK-A00 MRK-A00 MRK-A00 MRK-A00
- MRW-10A MRW-10A MRW-10A MRW-10A
AVXDSH100CE/
ND100LHXCA
AVXDSH110CE/
ND110LHXCA
AVXDSH145CE/
ND145LHXCA
*1) Mode
- HP : Heat Pump *2) Norminal cooling capacities are based on;
- Indoor temperature : 81˚F/27˚C DB, 66˚F/19˚C WB
- Outdoor temperature : 95˚F/35˚C DB, 75˚F/24˚C WB *3) Norminal heating capacities are based on;
- Indoor temperature : 70˚F/20˚C DB, 60˚F/15˚C WB
- Outdoor temperature : 47˚F/7˚C DB, 43˚F/6˚C WB *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications may be subject to change without prior notice for product improvement.
Samsung Electronics 2-35
Product Specifications
Indoor Unit(cont.)
MSP duct type
Model
Power Supply Ø,V,Hz 1,208~230,60 1,208~230,60 1,208~230,60
*1)
Mode
*2)
Cooling
Performance
Power
Noise Level Actual Noise Pressure (High)
Fan
Fan Speed
Airflow Rate
Refrigerant
Temperature Control - Micom&Thermistors Micom&Thermistors Micom&Thermistors Safety Devices - Fuse Fuse Fuse
Option Code
Piping Connections
Weight
Dimensions
Panel Size
Capacity
Condensate (with High fan speed) /h - - ­Input Consumption (Cooling/Heating) W 260 / 260 275 / 275 430 / 430 Running Current (Cooling/Heating) A 1.52 / 1.52 1.57 / 1.57 2.45 / 2.45
Type - Sirocco Fan Sirocco Fan Sirocco Fan
Motor
The progress of work(H/M/L) Cooling (H/M/L) 1,240/1,170/1090 1,280/1,190/1,110 1,040/950/880 Heating (H/M/L) 1,240/1,170/1,090 1,280/1,190/1,110 1,040/950/880 Cooling (High) Heating (High) 25.0 27.0 35.0 Cooling (High) Heating (High) 883 953 1236
External Static Pressure
Type - R410a R410a R410a Control Method - EEV EEV EEV
AVXDUH666CE -
ND666SHXCA -
Liquid (Flare)
Gas (Flare)
Drain (Quick Lock)
Net Weight
Shipping Weight
Net Dimensions (W×H×D)
Shipping Dimensions (W×H×D)
Model - - - -
Net Weight
Shipping Weight
Net Dimensions (W×H×D)
Shipping Dimensions (W×H×D)
*3)
Heating
*4)
Model - YSK140-200-4 YSK140-200-4 YDK-370S65023-01 Type - Non Feedback SSR Non Feedback SSR Non Feedback SSR Output W 180 180 218
Standard(Min.~Max) mmH2O 8 (6~10) 8 (6~10) 8 (6~10) Standard(Min.~Max) WG 0.31 (0.24~0.39) 0.31 (0.24~0.39) 0.31 (0.24~0.39)
- HP / HR HP / HR HP / HR
kW 10.0 11.0 14.5
Btu/h 30,000 36,000 48,000
kW 11.0 12.8 16.3
Btu/h 34,000 40,000 54,000
dB(A) 48 / 49 48 / 49 50 / 51
rpm
m³/min
CFM
Ø,mm 9.52 9.52 9.52 Ø,inch 3/8" 3/8" 3/8" Ø,mm 15.88 15.88 15.88 Ø,inch 5/8" 5/8" 5/8" Ø,mm VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) Ø,inch VP25 (OD 1 1/4",ID 1") VP25 (OD 1 1/4",ID 1") VP25 (OD 1 1/4",ID 1")
kg 46.0 46.0 52.0
lbs 101.4 101.4 114.6
kg 54.5 54.5 60.0
lbs 120.2 120.2 132.3 mm 1,150×320×480 1,150×320×480 1,200×360×650 inch 43.3×12.6×18.9 43.3×12.6×18.9 47.2×14.2×25.6 mm 1,390×424×584 1,390×424×584 1,456×434×778 inch 54.7×16.7×23 54.7×16.7×23 57.3×17.1×30.6
kg---
lbs - - -
kg---
lbs - - ­mm--­inch - - ­mm--­inch - - -
AVXDUH100CE/
ND100SHXCA
1,000/880/744 1,071/921/787 895/763/645
25.0 27.0 35.0
883 953 1236
015224-1F0202
-200001-300000
015224-1F0202
-200000-300000
AVXDUH110CE/
ND110SHXCA
015A24-100244
-200001-300000
015A24-100244
-200000-300000
AVXDUH145CE/
ND145SHXCA
015A24-130243
-200001-300000
015A24-130243
-200000-300000
2-36 Samsung Electronics
Indoor Unit(cont.)
MSP duct type(cont.)
Product Specifications
Functions
Standard Accessories
Optional Accessories
Model
Auto Restart - O O O Auto Swing - X X X Group/Individual Control - O O O External Contact Control - O O O Trouble Shooting by LED - X X X Installation Manual - O O O Operation Manual - O O O Pattern Sheet for Installation - X X X Flexible Drain Hose - O O O Filter / Safety Grille - Filter (Washable) Filter ( Washable) Filter (Washable) Drain Pump (Pumping speed, lift) /h,mm 24, 750 24, 750 24, 750
Wireless Remote Controller
Wired Remote Controller
External Contact Interface Module - MIM-B14 MIM-B14 MIM-B14 Drain Pump - MDP-M075SGU1 MDP-M075SGU1 MDP-M075SGU2
Remote Controller Receiver Kit(Duct)
Remote Controller Receiver Wire(Duct)
AVXDUH666CE - MR-BH01U MR-BH01U MR-BH01U ND666SHXCA - MR-BH01 MR-BH01 MR-BH01
Simplified - MWR-SH00 MWR-SH00 MWR-SH00 Multi Function - MWR-WE00 MWR-WE00 MWR-WE00 Premium - MWR-WS01 MWR-WS01 MWR-WS01
- MRK-A00 MRK-A00 MRK-A00
- MRW-10A MRW-10A MRW-10A
AVXDUH100CE/
ND100SHXCA
AVXDUH110CE/
ND110SHXCA
AVXDUH145CE/
ND145SHXCA
*1) Mode
- HP : Heat Pump *2) Norminal cooling capacities are based on;
- Indoor temperature : 81˚F/27˚C DB, 66˚F/19˚C WB
- Outdoor temperature : 95˚F/35˚C DB, 75˚F/24˚C WB
*3) Norminal heating capacities are based on;
- Indoor temperature : 70˚F/20˚C DB, 60˚F/15˚C WB
- Outdoor temperature : 47˚F/7˚C DB, 43˚F/6˚C WB *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications may be subject to change without prior notice for product improvement.
Samsung Electronics 2-37
Product Specifications
Indoor Unit(cont.)
BIG duct type
Model
Power Supply Ø,V,Hz
*1)
Mode
*2)
Cooling
Performance
Power
Noise Level Actual Noise Pressure (High)
Fan
Fan Speed
Airflow Rate
Refrigerant
Temperature Control ­Safety Devices -
Option Code
Piping Connections
Weight
Dimensions
Panel Size
Capacity
Condensate (with High fan speed) /h Input Consumption (Cooling/Heating) W Running Current (Cooling/Heating) A
Type -
Motor
The progress of work(H/M/L)
Heating (H/M/L) Cooling (High) Heating (High) Cooling (High) Heating (High)
External Static Pressure
Type ­Control Method -
ND666CE -
ND666CA -
Liquid (Flare)
Gas (Flare)
Drain (Quick Lock)
Net Weight
Shipping Weight
Net Dimensions (W×H×D)
Shipping Dimensions (W×H×D)
Model - - -
Net Weight
Shipping Weight
Net Dimensions (W×H×D)
Shipping Dimensions (W×H×D)
*3)
Heating
*4)
Model ­Type ­Output W
Standard(Min.~Max) mmH2O Standard(Min.~Max) WG
-
kW
Btu/h
kW
Btu/h
dB(A)
rpmCooling (H/M/L)
m³/min
CFM
Ø,mm Ø,inch Ø,mm Ø,inch Ø,mm Ø,inch
kg
lbs
kg
lbs mm inch mm inch
kg - -
lbs - -
kg - -
lbs - ­mm - ­inch - ­mm - ­inch - -
ND220HHXCE
ND220HHXCA
1/208-230/60 1/208-230/60
HP / HR HP / HR
22.4 28.0
76,800 96,000
25.0 31.5
85,200 108,000
530 790
3.8 5.9 47 48
Sirocco Fan Sirocco Fan
DL-13875SSOB DL-13875SSOB
BLDC BLDC
400 400
965/870/810 1100/1000/870 965/870/810 1100/1000/870
58 72
58 72 2,048 2,542 2,048 2,542
15(5-25) 15(5-28)
0.59(0.20-0.98) 0.59(0.20-1.10) R410A R410A
EEV EEV
Micom&Thermistors Micom&Thermistors
Fuse Fuse
"015A171600E8
-200001300000"
"015A171600E8
-200000300000"
9.52 9.52 3/8" 3/8"
19.05 22.2 3/4" 7/8"
VP25(OD32, ID25) VP25(OD32, ID25)
VP25(OD1 1/4", ID 1") VP25(OD1 1/4", ID 1")
95 95 210 210 105 105 232 232
1240x470x1040 1240x470x1040
48.8x18.5x41.0 48.8x18.5x41.0
1507x558x1155 1507x558x1155
59.4x22.0x45.5 59.4x22.0x45.5
ND280HHXCE ND280HHXCA
"015A1717025B
-200001300000"
"015A1717025B
-200000300000"
2-38 Samsung Electronics
Indoor Unit(cont.)
BIG duct type(cont.)
Product Specifications
Functions
Standard Accessories
Optional Accessories
Model
Auto Restart - O O Auto Swing - X X Group/Individual Control - O O External Contact Control - O O Trouble Shooting by LED - X X Installation Manual - O O Operation Manual - O O Pattern Sheet for Installation - O O Flexible Drain Hose - O O Filter / Safety Grille - X X Drain Pump (Pumping speed, lift) /h,mm 24, 470 24, 470
Wireless Remote Controller
Wired Remote Controller
External Contact Interface Module - MIM-B14 MIM-B14 Drain Pump - MDP-N047SNC1 MDP-N047SNC1
Remote Controller Receiver Kit(Duct)
Remote Controller Receiver Wire(Duct)
ND666CE - MR-BH01U MR-BH01U ND666CA - MR-BH00 MR-BH00
Simplified - MWR-WH02 MWR-WH02 Multi Function - MWR-WE10 MWR-WE10 Premium - - -
- MRK-A00 MRK-A00
- MRW-10A MRW-10A
ND220HHXCE
ND220HHXCA
ND280HHXCE ND280HHXCA
*1) Mode
- HP : Heat Pump *2) Norminal cooling capacities are based on;
- Indoor temperature : 81˚F/27˚C DB, 66˚F/19˚C WB
- Outdoor temperature : 95˚F/35˚C DB, 75˚F/24˚C WB
*3) Norminal heating capacities are based on;
- Indoor temperature : 70˚F/20˚C DB, 60˚F/15˚C WB
- Outdoor temperature : 47˚F/7˚C DB, 43˚F/6˚C WB *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications may be subject to change without prior notice for product improvement.
Samsung Electronics 2-39
Product Specifications
Indoor Unit(cont.)
Wall Mounted type_Vivace
Model
Power Supply Ø,V,Hz 1,208~230,60 1,208~230,60 1,208~230,60 1,208~230,60 1,208~230,60
*1)
Mode
*2)
Cooling
Performance
Power
Noise Level Actual Noise Pressure (High)
Fan
Fan Speed
Airflow Rate
Refrigerant
Temperature Control - Micom&Thermistors M icom&Thermistors Micom&Thermistors Micom&Thermistors Micom&Thermistors Safety Devices - Fuse Fuse Fuse Fuse Fuse
Option Code
Piping Connections
Weight
Dimensions
Functions
Standard Accessories
Capacity
Condensate (with High fan speed) /h 1.12 1.44 1.91 3.03 3.51 Input Consumption (Cooling/Heating) W 30 / 30 30/30 35 / 35 50 / 50 50 / 50 Running Current (Cooling/Heating) A 0.13 / 0.13 0.18/0.18 0.19 / 0.19 0.3 / 0.3 0.3 / 0.3
Type - Crossflow Fan Crossflow Fan Crossflow Fan Crossflow Fan Crossflow Fan
Motor
Cooling (H/M/L) Heating (H/M/L) 965/843/720 965/843/720 1,175/1,035/930 1,245/1,105/1,000 1,315/1,210/1,105 Cooling (High) Heating (High) 7.3 7.3 8.8 14.0 14.0 Cooling (High) Heating (High) 258 258 311 494 494
External Static Pressure
Type - R410a R410a R410a R410a R410a Control Method - EEV (optional) EEV (optional) EEV (optional) EE V (optional) EEV (optional)
AVXWVH666CE -
ND666VHXCA -
Liquid (Flare)
Gas (Flare)
Drain (Quick Lock)
Net Weight
Shipping Weight
Net Dimensions (W×H×D)
Shipping Dimensions (W×H×D)
Auto Restart - O O O O O Auto Swing - O O O O O Group/Individual Control - O O O O O External Contact Control - O O O O O Trouble Shooting by LED - O O O O O Installation Manual - O O O O O Operation Manual - O O O O O Pattern Sheet for Installation - X X X X X Flexible Drain Hose - O O O O O Filter / Safety Grille - Filter (Washable) Filter (Washable) Filter (Washable) Filter (Washable) Filter (Washable)
*3)
Heating
*4)
Model - YDK-016S1408-01 YDK-016S1408-01 YDK-016S1408-01 YDK-045S42213-02 YDK-045S42213-02 Type - Feedback SSR Feedback SSR Feedback SSR Feedback SSR Feedback SSR Output W 23.0 23.0 23.0 42.0 42.0
Standard(Min.~Max) mmH2O - - - - ­Standard(Min.~Max) WG - - - - -
AVXWVH020CE/
ND020VHXCA
- HP / HR HP / HR HP / HR HP / HR HP / HR
kW 2.0 3.2 4.0 5.2 6.0
Btu/h 6,000 9,500 12,000 18,000 20,000
kW 2.3 3.6 4.5 6.0 6.8
Btu/h 7,000 10,500 13,500 20,000 23,000
dB(A) 42 / 42 43 / 43 43 / 43 50 / 50 50 / 50
1,000/878/755 1,000/878/755 1,105/965/860 1,245/1,105/1,000 1,315/1,210/1,105
rpm
m³/min
CFM
Ø,mm 6.35 6.35 6.35 6.35 6.35 Ø,inch 1/4" 1/4" 1/4" 1/4" 1/4" Ø,mm 12.70 12.70 12.70 12.70 12.70 Ø,inch 1/2" 1/2" 1/2" 1/2" 1/2" Ø,mm ID 18 hose ID 18 hose ID 18 hose ID 18 hose ID 18 hose Ø,inch - - - - -
kg 8.5 7.8 7.8 12.0 12.0
lbs 18.7 17.2 17.2 26.5 26.5
kg 11.5 9.4 9.4 15.0 15.0
lbs 25.4 20.7 20.7 33.1 33.1 mm 825×285×189 825×285×189 825×285×189 1,065×298×218 1,065×298×218 inch 32.5×11.2×7.4 32.5×11.2×7.4 32.5×11.2×7.4 42×11.7×8.6 42×11.7×8.6 mm 900×349×252 900×349×252 900×349×252 1,137×377×299 1,137×377×299 inch 35.4×13.7×10 35.4×13.7×10 35.4×13.7×10 44.8×14.8×11.8 44.8×14.8×11.8
7.0 7.0 8.2 13.3 13.3
247 247 290 470 470
004602-1120E7 200001-300000
004602-1120E7 200000-300000
AVXWVH032CE/
ND032VHXCA
004602-1320E7 200001-300000
004602-1320E7 200000-300000
AVXWVH040CE/
ND040VHXCA
007602-15221A 200001-300000
007602-15221A 200000-300000
AVXWVH052CE/
ND052VHXCA
005606-1A225E
200001-300000
005606-1A225E
200000-300000
AVXWVH060CE/
ND060VHXCA
005606-1C2371 200001-300000
005606-1C2371 200000-300000
2-40 Samsung Electronics
Indoor Unit(cont.)
Wall Mounted type_Vivace(cont.)
Product Specifications
Optional Accessories
Model
Wireless Remote Controller
Wired Remote Controller
External Contact Interface Module - MIM-B14 MIM-B14 MIM-B14 MIM-B14 MIM -B14
*1) Mode
- HP : Heat Pump *2) Norminal cooling capacities are based on;
*3) Norminal heating capacities are based on;
*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications may be subject to change without prior notice for product improvement.
AVXWVH666CE - MR-BH01U MR-BH01U MR-BH01U MR-BH01U MR-BH01U ND666VHXCA - MR-BH01 MR-BH01 MR-BH01 MR-BH01 MR-BH01
Simplified - MWR-SH00 MWR-SH00 MWR-SH00 MWR-SH00 MWR-SH00 Multi Function - MWR-WE00 MWR-WE00 MWR-WE00 MWR-WE00 MWR-WE00 Premium - MWR-WS01 MWR-WS01 MWR-WS01 MWR-WS01 MWR-WS01
- Indoor temperature : 81˚F/27˚C DB, 66˚F/19˚C WB
- Outdoor temperature : 95˚F/35˚C DB, 75˚F/24˚C WB
- Indoor temperature : 70˚F/20˚C DB, 60˚F/15˚C WB
- Outdoor temperature : 47˚F/7˚C DB, 43˚F/6˚C WB
AVXWVH020CE/
ND020VHXCA
AVXWVH032CE/
ND032VHXCA
AVXWVH040CE/
ND040VHXCA
AVXWVH052CE/
ND052VHXCA
AVXWVH060CE/
ND060VHXCA
Samsung Electronics 2-41
Product Specifications
Indoor Unit(cont.)
Wall Mounted type_Neo forte without EEV
Model
Power Supply Ø,V,Hz 1,208~230,60 1,208~230,60 1,208~230,60 1,208~230,60 1,208~230,60
*1)
Mode
*2)
Cooling
Performance
Power
Noise Level Actual Noise Pressure (High)
Fan
Fan Speed
Airflow Rate
Refrigerant
Temperature Control - Micom&Thermistors Micom&Thermistors Micom&Thermistors Micom&Thermistors Micom&Thermistors
Safety Devices - Fuse Fuse Fuse Fuse Fuse
Option Code
Piping Connections
Weight
Dimensions
Capacity
*3)
Heating
Condensate (with High fan speed) /h 1.12 1.44 1.91 2.87 3.51
Input Consumption (Cooling/Heating) W 25 / 25 25 / 25 30 / 30 45 / 45 50/50
Running Current (Cooling/Heating) A 0.16 / 0.16 0.16 / 0.16 0.18 / 0.18 0.27 / 0.27 0.30/0.30
*4)
Type - Crossflow fan Crossflow fan Crossflow fan Crossflow fan Crossflow fan
Model - YDK-016S41408-01 YDK-016S41408-01 YDK-016S41408-01 YDK-045S42213-02 YDK-045S42213-02
Motor
Cooling (H/M/L)
Heating (H/M/L) 1,105 / 1,018 / 930 1,105 / 1,018 / 930 1,280 / 1,158 / 1,035 1,315 / 1,193 / 1,070 1,385 / 1,228 / 1,070
Cooling (High)
Heating (High) 8.2 8.2 9.5 13.0 15.0
Cooling (High)
Heating (High) 290 290 335 459 530
External Static Pressure
Type - R410a R410a R410a R410a R410a
Control Method - EEV (optional) EEV (optional) EEV (optional) EEV (optional) EEV (optional)
AVXWNH666CE -
ND666NHXCA -
Liquid (Flare)
Gas (Flare)
Drain (Quick Lock)
Net Weight
Shipping Weight
Net Dimensions (W×H×D)
Shipping Dimensions (W×H×D)
Type - Feedback SSR Feedback SSR Feedback SSR Feedback SSR Feedback SSR
Output W 23 23 23 40 40
Standard(Min.~Max) mmH2O - - - -
Standard(Min.~Max) WG - - - -
AVXWNH020CE/
ND020NHXCA
- HP / HR HP / HR HP / HR HP / HR HP / HR
kW 2.0 3.2 4.0 5.2 6.0
Btu/h 6,000 9,500 12,000 18,000 20,000
kW 2.3 3.6 4.5 6.0 6.8
Btu/h 7,000 10,500 13,500 20,000 23,000
dB(A) 42 / 42 43 / 43 43 / 43 48 / 48 48 / 48
1,035 / 948 / 860 1,035 / 948 / 860 1,210 / 1,088 / 965 1,280 / 1,158 / 1,035 1,350 / 1,193 / 1,035
rpm
m³/min
CFM
Ø,mm 6.35 6.35 6.35 6.35 6.35
Ø,inch 1/4" 1/4" 1/4" 1/4" 1/4"
Ø,mm 12.70 12.70 12.70 12.70 12.70
Ø,inch 1/2" 1/2" 1/2" 1/2" 1/2"
Ø,mm ID 18 hose ID 18 hose ID 18 hose ID 18 hose ID 18 hose
Ø,inch - - - - -
kg 7.8 7.8 7.8 13.0 13.0
lbs 17.2 17.2 17.2 28.7 28.7
kg 9.4 9.4 9.4 16.0 16.0
lbs 20.7 20.7 20.7 35.3 35.3
mm 825×285×189 825×285×189 825×285×189 1,099×315×217 1,099×315×217
inch 32.5×11.2×7.4 32.5×11.2×7.4 32.5×11.2×7.4 43.3×12.4×8.5 43.3×12.4×8.5
mm 900×349×252 900×349×252 900×349×252 1,137×377×299 1,137×377×299
inch 35.4×13.7×10 35.4×13.7×10 35.4×13.7×10 44.8×14.8×11.8 44.8×14.8×11.8
7.8 7.8 9.3 12.0 14.0
275 275 328 424 494
027602-1120FA 200001-300000
027602-1120FA 200000-300000
AVXWNH032CE/
ND032NHXCA
027602-1320FA 200001-300000
027602-1320FA 200000-300000
AVXWNH040CE/
ND040NHXCA
027602-15224D 200001-300000
027602-15224D 200000-300000
AVXWNH052CE/
ND052NHXCA
026602-1A226F 200001-300000
026602-1A226F 200000-300000
AVXWNH060CE/
ND060NHXCA
026602-1C228F 200001-300000
026602-1C228F 200000-300000
2-42 Samsung Electronics
Indoor Unit(cont.)
Wall Mounted type_Neo forte without EEV(cont.)
Product Specifications
Functions
Standard Accessories
Optional Accessories
Model
Auto Restart - O O O O O
Auto Swing - O O O O O
Group/Individual Control - O O O O O
External Contact Control - O O O O O
Trouble Shooting by LED - O O O O O
Installation Manual - O O O O O
Operation Manual - O O O O O
Pattern Sheet for Installation - X X X X X
Flexible Drain Hose - O O O O O
Filter / Safety Grille - Filter (Washable) Filter (Washable) Filter (Washable) Filter (Washable) Filter (Washable)
Wireless Remote Controller
Wired Remote Controller
External Contact Interface Module - MIM-B14 MIM-B14 MIM-B14 MIM-B14 MIM -B14
AVXWNH666CE - MR-BH01U MR-BH01U MR-BH01U MR-BH01U MR-BH01U
ND666NHXCA - MR-BH01 MR-BH01 MR-BH01 MR-BH01 MR-BH01
Simplified - MWR-SH00 MWR-SH00 MWR-SH00 MWR-SH00 MWR-SH00
Multi Function - MWR-WE00 MWR-WE00 MWR-WE00 MWR-WE00 MWR-WE00
Premium - MWR-WS01 MWR-WS01 MWR-WS01 MWR-WS01 MWR-WS01
AVXWNH020CE/
ND020NHXCA
AVXWNH032CE/
ND032NHXCA
AVXWNH040CE/
ND040NHXCA
AVXWNH052CE/
ND052NHXCA
AVXWNH060CE/
ND060NHXCA
*1) Mode
- HP : Heat Pump *2) Norminal cooling capacities are based on;
- Indoor temperature : 81˚F/27˚C DB, 66˚F/19˚C WB
- Outdoor temperature : 95˚F/35˚C DB, 75˚F/24˚C WB
*3) Norminal heating capacities are based on;
- Indoor temperature : 70˚F/20˚C DB, 60˚F/15˚C WB
- Outdoor temperature : 47˚F/7˚C DB, 43˚F/6˚C WB *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications may be subject to change without prior notice for product improvement.
Samsung Electronics 2-43
Product Specifications
Indoor Unit(cont.)
Wall Mounted type_Neo forte with EEV
Model ND020QHXCA ND032QHXCA ND040QHXCA ND052QHXCA ND060QHXCA
Power Supply Ø,V,Hz 1,208~230,60 1,208~230,60 1,208~230,60 1,208~230,60 1,208~230,60
*1)
Mode
*2)
Cooling
Performance
Power
Noise Level Actual Noise Pressure (High)
Fan
Fan Speed
Airflow Rate
Refrigerant
Temperature Control - Micom&Thermistors Micom&Thermistors Micom&Thermistors Micom&Thermistors Micom&Thermistors
Safety Devices - Fuse Fuse Fuse Fuse Fuse
Option Code
Piping Connections
Weight
Dimensions
Capacity
*3)
Heating
Condensate (with High fan speed) /h 1.12 1.44 1.91 2.87 3.51
Input Consumption (Cooling/Heating) W 25 / 25 25 / 25 30 / 30 45 / 45 50/50
Running Current (Cooling/Heating) A 0.16 / 0.16 0.16 / 0.16 0.18 / 0.18 0.27 / 0.27 0.27 / 0.27
*4)
Type - Crossflow fan Crossflow fan Crossflow fan Crossflow fan Crossflow fan
Model - YFK-8-4-SX06 YFK-8-4-SX06 YFK-8-4-SX06 YDK-045S42213-02 YDK-045S42213-02
Motor
Cooling (H/M/L)
Heating (H/M/L) 1,105 / 1,018 / 930 1,105 / 1,018 / 930 1,280 / 1,158 / 1,035 1,315 / 1,193 / 1,070 1,315 / 1,193 / 1,070
Cooling (High)
Heating (High) 8.2 8.2 9.5 13.0 13.0
Cooling (High)
Heating (High) 290 290 335 459 530
External Static Pressure
Type - R410a R410a R410a R410a R410a
Control Method - EEV EEV EEV EEV EEV
ND666QHXCA -
Liquid (Flare)
Gas (Flare)
Drain (Quick Lock)
Net Weight kg 9 9 9 13.0 13.0
Shipping Weight kg 11 11 11 16.0 16.0
Net Dimensions (W×H×D)
Shipping Dimensions (W×H×D)
Type - Feedback SSR Feedback SSR Feedback SSR Feedback SSR Feedback SSR
Output W 16 16 16 40 40
Standard(Min.~Max) mmH2O - - - -
Standard(Min.~Max) WG - - - -
- HP / HR HP / HR HP / HR HP / HR HP / HR
kW 2.0 3.2 4.0 5.2 6.0
Btu/h 6,000 9,500 12,000 18,000 20,000
kW 2.3 3.6 4.5 6.0 6.8
Btu/h 7,000 10,500 13,500 20,000 23,000
dB(A) 43 / 43 44 / 44 44 / 44 49 / 49 49 / 49
1,035 / 948 / 860 1,035 / 948 / 860 1,210 / 1,088 / 965 1,280 / 1,158 / 1,035 1,280 / 1,158 / 1,035
rpm
m³/min
CFM
Ø,mm 6.35 6.35 6.35 6.35 6.35
Ø,inch 1/4" 1/4" 1/4" 1/4" 1/4"
Ø,mm 12.70 12.70 12.70 12.70 12.70
Ø,inch 1/2" 1/2" 1/2" 1/2" 1/2"
Ø,mm ID 18 hose ID 18 hose ID 18 hose ID 18 hose ID 18 hose
Ø,inch - - - - -
mm 825×285×189 825×285×189 825×285×189 1,099×315×217 1,099×315×217
inch 32.5×11.2×7.4 32.5×11.2×7.4 32.5×11.2×7.4 43.3×12.4×8.5 43.3×12.4×8.5
mm 900×349×252 900×349×252 900×349×252 1,137×377×299 1,137×377×299
inch 35.4×13.7×10 35.4×13.7×10 35.4×13.7×10 44.8×14.8×11.8 44.8×14.8×11.8
7.8 7.8 9.3 12.0 12.0
275 275 328 424 424
027602-1120FA 200000-300000
027602-1420FA 200000-300000
027602-16224D 200000-300000
026602-19226F 200000-300000
026602-1B226F 200000-300000
2-44 Samsung Electronics
Indoor Unit(cont.)
Wall Mounted type_Neo forte with EEV(cont.)
Model ND020QHXCA ND032QHXCA ND040QHXCA ND052QHXCA ND060QHXCA
Auto Restart - O O O O O
Auto Swing - O O O O O
Functions
Standard Accessories
Optional Accessories
Group/Individual Control - O O O O O
External Contact Control - O O O O O
Trouble Shooting by LED - O O O O O
Installation Manual - O O O O O
Operation Manual - O O O O O
Pattern Sheet for Installation - X X X X X
Flexible Drain Hose - O O O O O
Filter / Safety Grille - Filter (Washable) Filter (Washable) Filter (Washable) Filter (Washable) Filter (Washable)
Wireless Remote Controller
Wired Remote Controller
External Contact Interface Module - MIM-B14 MIM-B14 MIM-B14 MIM-B14 MIM -B14
AVXWNH666CE - MR-BH01U MR-BH01U MR-BH01U MR-BH01U MR-BH01U
ND666NHXCA - MR-BH01 MR-BH01 MR-BH01 MR-BH01 MR-BH01
Simplified - MWR-SH00 MWR-SH00 MWR-SH00 MWR-SH00 MWR-SH00
Multi Function - MWR-WE00 MWR-WE00 MWR-WE00 MWR-WE00 MWR-WE00
Premium - MWR-WS01 MWR-WS01 MWR-WS01 MWR-WS01 MWR-WS01
Product Specifications
*1) Mode
- HP : Heat Pump *2) Norminal cooling capacities are based on;
- Indoor temperature : 81˚F/27˚C DB, 66˚F/19˚C WB
- Outdoor temperature : 95˚F/35˚C DB, 75˚F/24˚C WB
*3) Norminal heating capacities are based on;
- Indoor temperature : 70˚F/20˚C DB, 60˚F/15˚C WB
- Outdoor temperature : 47˚F/7˚C DB, 43˚F/6˚C WB *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications may be subject to change without prior notice for product improvement.
Samsung Electronics 2-45
Product Specifications
Indoor Unit(cont.)
Q
Ceiling type
Power Supply ø/V/Hz 1/220~240/50 1/220~240/50
1)
Mode*
Performance
Power
Sound Level Sound Pressure (High/Low)*
Fan
Airflow Rate
Refrigerant
Temperature Control - Micom&Thermistors Micom&Thermistors Safety Devices - Fuse Fuse
Piping Connections
Weight
Dimensions
Functions
Standard Accessories
Optional Accessories
Capacity
Condensate (with High fan speed) Liters/h 2.87 2.87 Input W 72 120 Running Current A 0.33 0.6
Type - Sirocco Fan Sirocco Fan
Motor
Cooling (High) m Heating (High) m Type - R410A R410A Control Method - EEV EEV
Liquid (Flare) ø, mm 9.52 9.52 Gas (Flare) ø, mm 15.88 15.88 Drain ø, mm VP25 (OD 32,ID 25) VP25 (OD 32,ID 25) Net Weight kg 31.0 31.0 Shipping Weight kg 39.0 39.0 Net Dimensions (W x H x D) mm 1,100x199x600 1,100x199x600 Shipping Dimensions (W x H x D) mm 1,330x330x730 1,330x330x730 Auto Restart - O O Auto Swing - X X Group/Individual Control - O O External Contact Control - O O Trouble Shooting by LED - X X Installation Manual - O O Operation Manual - O O Pattern Sheet for Installation - X X Flexible Drain Hose - O O Filter / Safety Grille - Filter (Washable) Filter (Washable) Wireless Remote Controller - MRK-A01 MRK-A01
Wired Remote Controller
External Contact Interface Module - MDP-E075SEE MDP-E075SEE1
Model AVXTFH056E6 AVXTFH071E6
2)
Cooling*
3)
Heating*
4)
Model - YSK140-60-4B YSK140-60-4B Type - Non Feedback SSR Non Feedback SSR Output W *5) *5)
Simplified - MWR-TH01 MWR-TH01 Standard - MWR-WS00 MWR-WS00 Premium - MIM-B14 MIM-B14
kW 5.6 7.1
Btu/h 19,100 24,200
kW 6.3 8.0
Btu/h 21,400 27,200
dB(A) 36 / 32 36 / 32
3
/min 16.5 16.5
3
/min 20.0 20.0
HP / HR HP / HR
*1) Mode
- HP : Heat Pump, HR : Heat Recovery
*2) Nominal cooling capacities are based on;
- Indoor temperature : 81°F/27°C DB, 66°F/19°C WB
- Outdoor temperature : 95°F/35°C DB, 75°F/24°C WB, Equivalent refrigerant piping : 7.5m(24.6ft), Level differences : 0m
*3) Nominal heating capacities are based on;
- Indoor temperature : 70°F/20°C DB, 60°F/15°C WB
- Outdoor temperature : 47°F/7°C DB, 43°F/6°C WB, Equivalent refrigerant piping : 7.5m(24.6ft), Level differences : 0m *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications may be subject to change without prior notice for product improvement.
2-46 Samsung Electronics
2-2-2 Outdoor Unit
QRVXVHT075/100/125FE, RD075/100/125VHXFA, RD075/100/125VRXFA
Product Specifications
Model
Power Supply Ø,V,Hz 3,208~230,60 3,208~230,60 3,208~230,60
*1)
Mode
Horse Power HP 7.5 10.0 12.5
*2)
Performance
Power
COP
Compressor
Fan
Safety Devices
Piping Connections
Refrigerant
*4)
Sound
Set Size
Cooling
Capacity
Heating
Nominal input
Circuit Breaker (MCCB/ELB) Cooling - 3.84 3.75 3.29 Heating - 4.61 4.47 3.92 Model ­Type - Digital Scroll Fixed Scroll Digital Scroll Fixed Scroll Digital Scroll Fixed Scroll Number EA 1 1 1 1 1 1 Piston Displacement cc/Rev 67.1 Output kW 6.94 5.83 6.94 5.83 8.01 8.01
Lubricant
Type/Control - Propeller/BLDC Propeller/BLDC Propeller/BLDC Motor Output W 630 630 630
Airflow Rate
External Static Pressure
Mechanical Type
Electronic Type
Liquid
Gas
Oil (Flare)
Installation Limitation
Type - R410A R410A R410A
Factory Charging
Sound Pressure dB(A) 57 58 60
Net Weight
Shipping Weight
Net Dimensions (WxHxD)
Shipping Dimensions (WxHxD)
Cooling kW 5.50 7.50 10.70 Heating kW 5.15 7.08 10.09
Type - 3MAF POE 3MAF POE 3MAF POE Charging cc 1,685 1,685 1,685 1,685 1,685 1,685
Max.
Max. Length
Max. Height
Btu/h 72,000 96,000 120,000
*3)
Btu/h 81,000 108,000 135,000
m³/min 170 170 180
mmAq 8 8 8
Ø,mm 9.52 9.52 12.70
Ø,inch 3/8” 3/8” 1/2”
Ø,mm 19.05 22.23 28.58
Ø,inch 3/4” 7/8” 1 1/8”
Ø,mm - - -
Ø,inch - - -
RVXVHT075FE/RD075VHXFA/
RD075VRXFA
-HPHPHP
kW 21.1 28.1 35.2
kW 23.7 31.7 39.6
A 40 50 60
ZPJ72KCE-TF5-496 ZPI61KCE-TF5-496 ZPJ72KCE-TF5-496
58.1 67.1 58.1 77.2 77.2
CFM 6,004 6,004 6,357
Pa 78.5 78.5 78.5
- High Pressure Switch High Pressure Switch High Pressure Switch
- Crank Case Heater Crank Case Heater Crank Case Heater
- Fuse for PCB Fuse for PCB Fuse for PCB
- Over Voltage Protection Over Voltage Protection Over Voltage Protection
- Current Transformer Current Transformer Current Transformer
- Fan Over Heat/Current Protector Fan Over Heat/Current Protector Fan Over Heat/Current Protector
m 200 200 200
ft 656 656 656
m 50 50 50
ft 164 164 164
kg 6.5 7.5 9.0 lbs 14.4 16.5 19.8
kg 240 240 280 lbs 529 529 617 kg 253 253 297
lbs 558 558 655 mm 880×1,723×765 880×1,723×765 1,200×1,723×765 inch 34.6×67.8×30.1 34.6×67.8×30.1 47.2×67.8×30.1 mm 948×1,888×832 948×1,888×832 1,268×1,888×832 inch 37.3×74.3×32.8 37.3×74.3×32.8 50×74.3×32.8
RVXVHT100FE/RD100VHXFA/
RD100VRXFA
ZPI61KCE-TF5-496 ZPJ83KCE-TF5-496 ZPI83KCE-TF5-496
RVXVHT125FE/RD125VHXFA/
RD125VRXFA
Samsung Electronics 2-47
Product Specifications
Outdoor Unit(cont.)
RVXVHT075/100/125FE(cont.)
Operating Temp. Range
Standard Accessories
Cooling
Heating
Model
*1) Mode
- HP : Heat Pump *2) Norminal cooling capacities are based on;
- Indoor temperature : 81˚F/27˚C DB, 66˚F/19˚C WB
- Outdoor temperature : 95˚F/35˚C DB, 75˚F/24˚C WB
*3) Norminal heating capacities are based on;
- Indoor temperature : 70˚F/20˚C DB, 60˚F/15˚C WB
- Outdoor temperature : 47˚F/7˚C DB, 43˚F/6˚C WB *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications may be subject to change without prior notice for product improvement.
RVXVHT075FE/RD075VHXFA/
˚C -5 ~ 43 -5 ~ 43 -5 ~ 43 ˚F 23~109 23~109 23~109 ˚C -20 ~ 24 -20 ~ 24 -20 ~ 24 ˚F -4~75 -4~75 -4~75
- Installation Manual Installation Manual Installation Manual
- Drain Plug Drain Plug Drain Plug
RD075VRXFA
RVXVHT100FE/RD100VHXFA/
RD100VRXFA
RVXVHT125FE/RD125VHXFA/
RD125VRXFA
2-48 Samsung Electronics
Outdoor Unit(cont.)
QRD040/050MHXCA
Product Specifications
Power Supply ø,V,H z 1/208~230/60 1/208~230/60 Mode - HP HP
Performance
Power
EER Cooling - 9.6 9.0 SEER - 13.2 13.1 HSPF - 7.85 7.9
Compressor
Fan
Piping Connections
Refrigerant
Refrigerant charging
Set Size
Operating Temp. Range
Standard Accessories
Horse Power HP 4 5
Capacity
Nominal input
Circuit Breaker (MCCB/ELB) A 40
Model - UG5T360FUCEKSS UG5T450FUCEXSS Type - Twin BLDC Twin BLDC Number EA 1 1 Piston Displacement cc/Rev - ­Out put kW - -
Lubricant
Type/Control - Propeller/BLDC Propeller/BLDC Motor Output W 130 130 Airflow Rate(C/H) m External Static Pressure
Liquid
Gas
Oil (Flare)
Installation Limitation
Type - R410A R410A
Factory Charging
3/8” (Charge according to liquid piping)
1/4” (Charge according to liquid piping)
Net Weight
Shipping Weight
Net Dimensions (WxHxD)
Shipping Dimensions (WxHxD)
Cooling
Heating
Model RD040MHXCA RD050MHXCA
Cooling
Heating
Cooling kW 3.0 4.5 Heating kW 3.4 4.2
Type - - ­Charging cc 1,300 1,300
Max.
Max. Length
Max. Height
kW 11.2 14.0
Btu/h 36,000 48,000
kW 12.5 16.0
Btu/h 40,000 54,000
40
3
/min 97/102 97/102
mmAq - -
Pa - ­ø, mm 9.52 9.52 ø, inch 3/8” 3/8” ø, mm 15.88 15.88 ø, inch 5/8” 5/8” ø, mm - ­ø, inch - -
m70 70 ft 229 11/16 229 11/16 m30 30 ft 98 7/16 98 7/16
kg 4.0 4.0
lbs 8.82 8.82
g/m 50 50 oz/ft 0.54 0.54 g/m 20 20 oz/ft 0.215 0.215
kg 108 108
lbs 238.1 238.1
kg 116 116
lbs 255.7 255.7
mm 1,128x932x375 1,128x932x375
inch 44 13/32x36 11/16x14 3/4 44 13/32x36 11/16x14 3/4
mm 1,286x1,091x472 1,286x1,091x472
inch 50 5/8x42 15/16x18 19/32 50 5/8x42 15/16x18 19/32
˚C -5~43 -5~43
˚F 23~109.4 23~109.4
˚C -20~24 -20~24
˚F -4~75.2 -4~75.2
- Installation Manual Installation Manual
- Drain Plug Drain Plug
*1) Mode
- HP : Heat Pump *2) Norminal cooling capacities are based on;
- Indoor temperature : 81˚F/27˚C DB, 66˚F/19˚C WB - Outdoor temperature : 95˚F/35˚C DB, 75˚F/24˚C WB
*3) Norminal heating capacities are based on;
- Indoor temperature : 70˚F/20˚C DB, 60˚F/15˚C WB - Outdoor temperature : 47˚F/7˚C DB, 43˚F/6˚C WB *4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions. *5) Specifications may be subject to change without prior notice for product improvement.
Samsung Electronics 2-49
2-3 Accessory and Option Specifications
2-3-1 Accessories
Item Descriptions Code-No. Q'TY Remark
Installation Manual
Drain Plug
Drain Cap DB63-10355C 2 Outdoor Unit
DB98-31180A
(RVXVHT666FE,
RD666VHXFA)
DB98-32073A
(RD666MHXCA)
DB67-20011A
(RVXVHT666FE,
RD666VHXFA)
DB67-00477A
(RD666MHXCA)
1 Outdoor Unit
2 Outdoor Unit
Slim 1 way cassette panel PSSMA -
4 way cassette panel P4SMA -
mini 4 way cassette panel PMSMAA -
Global 4 way cassette pane PC4NUSKA -ND6664H666
MDP-E075SEE -
MDP-E075SEE1 -
Drain Pump
MDP-M075SGU1 -
MDP-M075SGU2 -
ND66616666
AVXCSH666 Series
ND66646666
AVXC4H666 Series
ND666M6666
AVXCMH666 Series
ND020~072L6666
AVXDSH020~072C6 Series
ND100~145L6666
AVXDSH100~145C6 Series
ND100~100S6666
AVXDUH100~110C6 Series
ND145S6666
AVXDUH145C6 Series
2-50 Samsung Electronics
MDP-N047SNC1 - ND220/2806 Series
Outdoor Joint MXJ-T38196 - Below 48 HP
MXJ-HA25126 - Below 160MBH (for 4 rooms)
Header Joint
MXJ-HA31156 - 160~240MBH (for 8 rooms)
MXJ-HA38196 - Over 240MBH (for 8 rooms)
Accessories (cont.)
Item Descriptions Code-No. Q'TY Remark
Product Specifications
MXJ-YA15096 - Below 51MBH
MXJ-YA25126 - 51~138MBH
MXJ-YA28126 - 138~160MBH
Y-Joint
MCU(Mode Control Unit)
Single EEV Kit
2 Room EEV Kit
MXJ-YA28156 - 160~240MBH
MXJ-YA33196 - 240~336MBH
MXJ-YA38196 - 336~468MBH
MXJ-YA44226 - Over 468MBH
MCU-X6NEF1 - For 6 rooms
MCU-X4NEF1 - For 4 rooms
MCU-X4VEF1 -
MCU-X4WEF1 -
MEV-A13SA - Below 12MBH
MEV-A16SA - Over 18~24MBH
MXD-A13K116A -
MXD-A13K200A - Below 12MBH(2 units)
MXD-A16K200A - 18MBH~24MBH(2 units)
For 4 rooms (EEV included)
Below 4.5MBH
For 4 rooms (EEV included)
Over 5.6MBH
Below 12MBH(1 unit)
+18MBH~24MBH(1 unit)
Wireless Signal Receiver Kit MRK-A00 - Option
Samsung Electronics 2-51
MXD-A22K200A - Over 24MBH(2 units)
MXD-A13K216A -
MXD-A13K300A - Below 12MBH(3 units)
3 Room EEV Kit
MXD-A16K213A -
MXD-A16K300A - 18MBH~24MBH(3 units)
Receiver Wire MRW-10A - Option
Below 12MBH(2 units)
+18MBH~24MBH(1 units)
Below 12MBH(1 unit)
+18MBH~24MBH(2 units)
Product Specifications
Accessories (cont.)
Item Descriptions Code-No. Q'TY Remark
Wireless Remote Controller MR-BH01U - Option
MWR-WS01 - Option
Wired Remote Controller
MWR-SH00 - Option
485 Interface Module MIM-B13A - Option
Ket Tag Interface Module MIM-B02 - Option
External Contact Interface
Module
SIM Interface Module MIM-B12 - Option
Centralized Controller MCM-A202A - Option
Operation Selection Switch MCM-C200 - Option
DMS MIM-D00 - Option
MIM-B14 - Option
2-52 Samsung Electronics
S-NET 3 MST-P3P - Option
S-NET mini MST-S3W - Option
3. Disassembly and Reassembly
Q
Necessary Tools
Item Remark
+Screw Driver
Monkey Spanner
–Screw Driver
Nipper
Electric Motion Driver
L-Wrench
Samsung Electronics 3-1
3-1 Indoor Unit
Q
Global 4way Cassette type
No Parts Procedure Remark
1 Panel 1) Push the handles on both sides of the
Samsung logo towards the product’s interior to open the Grille.
2) Push up the green knob in the Open direction, and detach the white link from the panel. Detach the safety clip.
3) Remove the 2 fixed screws to remove the Control-Box Cover. (Use +Screw Driver)
4) Remove the Remocon-Receiver and Blade Connector Wire from the PBA. (3EA)
5) Push the 4 panel corners and cover
downwards to remove it.
3-2 Samsung Electronics
Disassembly and Reassembly
No Parts Procedure Remark
6) Disassemble the bolts that are assembled with the indoor unit at the 4 panel corners.
7) Press the Steel Hangers at both sides of the panel inwards, and rotate them 90 degrees to remove it from the indoor unit’s Hock. Remove the panel from the indoor unit.
2 Control-Box 1) Disconnect the Connector Wire that is
connected to the indoor unit’s PBA from the PBA.
2) Unscrew the 2 fixed screws on both sides of
the Control Box, and disassemble the Control Box from the indoor unit. (Use +Screw Driver)
Samsung Electronics 3-3
Disassembly and Reassembly
No Parts Procedure Remark
3 Bell-Mouth 1) Unscrew the screw fixed on the Bell-Mouth.
(Use +Screw Driver)
2) Push the Bell-Mouth in the direction opposite to where it’s installed on the Control-Box to remove it.
4 Drain Pan 1) Unscrew the screws on the 4 corners of the
indoor unit. (Use +Screw Driver)
2) Remove the Drain Pan from the indoor unit
3-4 Samsung Electronics
Disassembly and Reassembly
No Parts Procedure Remark
5 Bell-Mouth 1) Remove the 2 fixed screws and disconnect
the white drainage hose from the Drain Pump. (Use +Screw Driver)
6 Evap. Temperature
Sensor
2) Remove the 2 screws and take the
Drain-Hose out from the indoor unit to disassemble the transparent Drain-Hose fixed on the side of the indoor unit. (Use +Screw Driver)
1) Use your hand to remove the temperature
sensor attached to the Evap Pipe along with the fixing clip.
Samsung Electronics 3-5
Disassembly and Reassembly
No Parts Procedure Remark
7 Fan
&
Motor
1) Turn the hexangular nut attached to the top of the Fan counterclockwise to remove it. Take the Fan out of the Motor.
2) Turn the three hexangular nuts on the
Motor counterclockwise to remove the nuts. Take the Motor Wires attached to these three locations out with your hands prior to removing the Motor.
7 Evap. Temperature
Sensor
1) Remove the screws of the 2 Steel Holder
Evaps that are used to fix the Heat Exchanger, and then remove it. (Use +Screw Driver)
2) Remove the 2 fixing screws of the Partition
Evap at the Heat Exchanger’s In/Out Pipe. (Use +Screw Driver)
3-6 Samsung Electronics
Disassembly and Reassembly
No Parts Procedure Remark
3) Remove the screw of the Cover Pipe that is used to fix the In/Out Pipe. Remove the In/Out Pipe. (Use +Screw Driver)
4) Remove the Heat Exchanger from the
indoor unit’s cabinet.
Samsung Electronics 3-7
Disassembly and Reassembly
Q
BIG DUCT
No Parts Procedure Remark
1 MOTOR
&
BLOWER
1) Detach the motor connectors from the PCB.
2) Unscew 16 screws and detach Cabinet-Base Blower. (Use+Screw Driver)
3) Unscrew 8 screws and detach Case-Blower. (Use +Screw Driver)
4) Unscrew 4 bolts and separate Motor & blower from Bracket-Motor. (Use +Screw Driver)
3-8 Samsung Electronics
No Parts Procedure Remark
5) Unscrew bolt and Separate Blower from the motor. (Use +Screw Driver)
Disassembly and Reassembly
2 EVAPORATOR &
DRAIN-PAN
1) Detach EEV and Sensor connectors from the PCB. (Use +Screw Driver)
2) Unscrew 8 screws and Detach Cover-Pipe. (Use +Screw Driver)
3) Unscrew 31 screws and detach Cabinet­Base Blower andCabinet-Base Drain. (Use +Screw Driver)
Samsung Electronics 3-9
Disassembly and Reassembly
No Parts Procedure Remark
4) Unscrew 10 screws and detach Drain-Pan from the indoor unit. (Use +Screw Driver)
5) Separate Evaporator from the indoor unit.
3-10 Samsung Electronics
3-2 Outdoor Unit
Q
RVXVHT075/100FE, RD075/100VHXFA, RD075/100/120VRXFA
No Parts Procedure Remark
1 Common In 1) Remove fixing screw from the Cabinet.
(Use +Screw Driver)
2) Separate the Cabinet from the Outdoor Unit.
Samsung Electronics 3-11
Disassembly and Reassembly
No Parts Procedure Remark
2) Separate the Electrical Component Box from the Outdoor Unit.
2 Motor
&
1) Remove fixing screw from the Bell Mouth. (Use +Screw Driver)
Fan
2) Separate the Bell Mouth.
3) Remove fixing bolt from the Fan.
4) Separate the Fan from the Outdoor Unit.
5) Remove fixing screw and after removing screws, separate the Motor.
3-12 Samsung Electronics
Q
RVXVHT125FE, RD125VHXFA, RD125VRXFA
No Parts Procedure Remark
1 Common In 1) Remove fixing screw from the Cabinet.
(Use +Screw Driver)
2) Separate the Cabinet from the Outdoor Unit.
Disassembly and Reassembly
Samsung Electronics 3-13
Disassembly and Reassembly
No Parts Procedure Remark
2) Separate the Electrical Component Box from the Outdoor Unit.
3-14 Samsung Electronics
No Parts Procedure Remark
Disassembly and Reassembly
2 Motor
&
Fan
1) Remove fixing screw from the Bell Mouth. (Use +Screw Driver)
2) Separate the Bell Mouth.
3) Remove fixing bolt from the Fan.
4) Separate the Fan from the Outdoor Unit.
5) Remove fixing screw and after removing screws, separate the Motor.
Samsung Electronics 3-15
Disassembly and Reassembly
Q
RD040/050MHXCA
No Parts Procedure Remark
1 General tasks 1) Stop operating the machine.
Disassemble the main power cable.
2) Unfasten the two fixing bolts and remove the right-front board.
3) Unfasten the eight fixing bolts and remove the upper cover. (Use +Screw Driver)
4) Unfasten the three bolts fixing the electrical control box to the right rear plate. (Use +Screw Driver)
5) Unfasten the twelve bolts and remove the right rear plate. (Use +Screw Driver)
3-16 Samsung Electronics
No Parts Procedure Remark
6) Unfasten the two bolts and disassemble the column. (Use +Screw Driver)
7) Unfasten the eleven bolts and disassemble the front board. (Use +Screw Driver)
Disassembly and Reassembly
2 Fan and electricity 1) Unfasten the flange nut to remove the fan.
(Refer to the right figure.) (Use Monkey Spanner.)
2) Unfasten the four fixing bolts and remove the electrical machinery. (Use Monkey Spanner.)
3) Disassemble the electrical cable. The white plug is for the upper part. The blue plug is for the lower part.
Samsung Electronics 3-17
Disassembly and Reassembly
No Parts Procedure Remark
4) Unfasten the two fixing bolts to disassemble the electricity support. (Use +Screw Driver)
3 Disassemble
the electrical
control box.
1) Disassemble the parts for the electrical control panel.
2) Push the buckle to loosen the three black cable ties.
3) Cut the white cable tie.
4) Unfasten the two fixing bolts between
3-18 Samsung Electronics
the electrical control box and the central separation plate. (Use +Screw Driver)
Disassembly and Reassembly
No Parts Procedure Remark
5) Unfasten the two ground bolts.
6) Lift the electrical control box and push it outward.
4 Disassemble
the electrical
control box.
(Inverter board)
1) Disassemble the left-front board.
2) Unfasten the one fixing bolt on the fixing board below the electrical control box and the left-rear board.
3) Unfasten the one fixing bolt on the fixing board below the electrical control box and the central separation plate. (Use +Screw Driver)
Samsung Electronics 3-19
Disassembly and Reassembly
No Parts Procedure Remark
4) Unfasten the two fixing bolts on the fixing board below the inverter control box and the electrical control box. (Use +Screw Driver)
5) Use a wrench to cut the cable tie.
6) Unplug the power cable for the compressor.
7) Disassemble the fixing plate below the electrical control box.
8) Unfasten the fixing bolt for the inverter control box and the right-rear board. (Use +Screw Driver)
3-20 Samsung Electronics
Disassembly and Reassembly
No Parts Procedure Remark
9) Push the fixing buckle with your thumb
to disassemble the black cable tie of the control box.
10) Use a knife to cut off the cable tie.
Unfasten the two bolts fixing the harness.
11) Unfasten the two bolts in the lower area
of the metering device and disassemble the harness. (Use +Screw Driver)
12) Disassemble the plug for the reactor
connection cable.
13) Unfasten the one bolt fixing the inverter
control box and the central separation board. (Use +Screw Driver)
Samsung Electronics 3-21
Disassembly and Reassembly
No Parts Procedure Remark
14) Unfasten the four bolts fixing the main
control box and the inverter control box. (Use +Screw Driver)
5 Heat exchanger and
compressor
15)
Pull out the inverter control box to separate it.
16) Finish disassembling the control box.
1) Discharge all the coolants.
2) Unfasten the fixing bolts of the blocking
valve. (Use +Screw Driver)
3) Using a welding machine, disassemble the
4) Disassemble the heat exchanger.
3-22 Samsung Electronics
inlet and outlet pipes.
Disassembly and Reassembly
No Parts Procedure Remark
5) Remove the noise protection sponge in
the external layer.
6) Remove the noise protection sponge in
the internal layer.
7) Unfasten the bolts fixing the electrical box
for the compressor. (Use Monkey Spanner.)
8) Disassemble the power cable for the
compressor.
9) Unfasten the three bolts on the
compressor leg. (Use Monkey Spanner.)
10) Disassemble the compressor.
Samsung Electronics 3-23
4. Troubleshooting
4-1 Setting Option Setup Method
4-1-1 PCB option code input method
4-1-1-1 example : 021E31142285
Be sure to input the option code suitable for the indoor unit by use of wireless remote controller after replacing the PCB of indoor unit. Follow to do the following 15 steps sequentially.
Operation method Applicable button Indicating state
6Step 1
Method) ① Remove the battery of remote
controller.
② Push the temperature adjustment
button simultaneously.
③ Insert the battery.
Result) When the display of remote controller is
indicated as shown in the right, then go to the step 2.
6Step 2
Method) If the first digit of remote
controller shows "0", go to the step 3.
• If it shows 1, press the Mode button one time to change it into 0 and then go to step 3.
Step 3
Method) Input the second digit of option code by
pressing the temperature adjustment button(up). example) 021E31142285
Result) If 2 is displayed, go to the step 4 (whenever
pressing the button, 1~9, A,B,C,D,E,F are lit in order.)
4-1
Samsung Electronics
Operation method Applicable button Indicating state
Step 4
Method)Input the third digit of option code by
pressing the temperature adjustment button(down). example) 021E31142285
Result)If 1 is displayed, go to the step 5.
Step 5
Method)Input the fourth digit of option code by
pressing the fan speed adjustment button. example) 021E31142285
Troubleshooting
Result)If E displays, go to step 6.
Step 6
Method)Input the fifth digit of option code
by pressing the On timer button. example) 021E31142285
Result)If 3 displays, go to step 7.
SEG 5
Samsung Electronics
4-2
Troubleshooting
Operation method Applicable button Indicating state
Step 7
Method) Input the sixth digit by pressing the
Off timer button. example) 021E31142285
Result)If 1 displays, go to step 8.
Step 8
Method)After completion up to step 7, pressing
mode button.
1~7 steps are saved internally. If the first number is 1 at the time,
it is correct. So go to step 9.
• If wanting to see the screen
of 2~7 steps, press the mode button to make the first digit 0.
Step 9
Method) Input the eighth digit by pressing
the temperature adjustment button(up). example) 021E31142285
Result)If 4 displays, go to step 10.
4-3
Samsung Electronics
Operation method Applicable button Indicating state
Step 10
Method)Input the ninth digit by pressing the
temperature adjustment button(down). example) 021E31142285
Result)If 2 displays, go to step 11.
Step 11
Method)Input the tenth digit by pressing fan speed
adjustment button. example) 021E31142285
Troubleshooting
Result)If 2 displays, go to step 12.
Step 12
Method)Input the 11st digit by pressing the
On timer button. example) 021E31142285
Result)If 8 displays, go to step 13.
Samsung Electronics
4-4
Troubleshooting
Operation method Applicable button Indicating state
Step 13
Method) Input the 12th digit by pressing the
Off timer button. example) 021E31142285
Result)If 5 displays, go to step 14.
Step 14
Method)Turn the remote controller toward the
indoor unit and press the On/Off button, and if the “Ting” or “Tiriring” sounds, the input of option is completed.
• If error displays, solve the
problem with reference to the right side.
Step 15
Method)If the steps 1 to 14 are completed, remove
the battery and insert it again to return to the original display of remote controller. (Operation mode/SET TEMP. /fan speed displays.)
Error
If the On/Off, Timer and Fan
indicator is flickering, the wrong option code is input. Put off the power of indoor unit and turn it on again and then input the option code again. If the same error occurs, it is the EEPROM is defective or not inserted. Replace the PCB.
If all of On/Off, Timer, Fan and Filter
Sign indicator are flickering along with the "Tiriring" sound, there is option code already input which are different from the current ones. Check the option code and press the button again if correct. Option code will be input.(Check the option code correctly. At the time, if the same error continues to occur, the option code is out of input range. Check the option code again and repeat the step 1~14.
4-5
rear side
Samsung Electronics
PCB option code input method(cont.)
4-1-1-2 example : 066064-170373
AVXWVH666C6/ND666V6666
Step 1 : Enter the Option Setup mode.
st
1
Take out the batteries of remote control.
Troubleshooting
2
nd
Press the temperature button simultaneously and
insert the battery again.
3
rd
Make sure the remocon display shown as .
Step 2 : Enter the Option Setup mode and select your option according to the following procedure.
1
The default value is .
3 2
1 4
Otherwise, push the button to Every time you push the button, the display panel reads
2
Push the button to set the display panel to . Every time you push the button, the display panel reads
. . .
3
Push the button to set the display panel to . Every time you push the button, the display panel reads
. . .
.
repeatedly.
repeatedly.
or repeatedly.
5
Setting is not required if you must
a value which has a
6
default.
Samsung Electronics
4
Push the button to set the display panel to . Every time you push the button, the display panel reads
. . .
5
Push the button to set the display panel to . Every time you push the button, the display panel reads
. . .
6
Push the button to set the display panel to . Every time you push the button, the display panel reads
. . .
repeatedly.
repeatedly.
repeatedly.
4-6
Troubleshooting
7
Press button, then the default value is .
8
Push the button to set the display panel to . Every time you push the button, the display panel reads 
. . .
repeatedly.
9 8
7
10
11
Setting is not required if you must
a value which has a
12
default.
9
Push the button to set the display panel to . Every time you push the button, the display panel reads 
. . .
10
Push the button to set the display panel to . Every time you push the button, the display panel reads 
. . .
11
Push the button to set the display panel to . Every time you push the button, the display panel reads 
. . .
12
Push the button to set the display panel to . Every time you push the button, the display panel reads 
. . .
Step 3 : Upon completion of the selection, check you made right selections.
Press the Mode Selection key, to set the display part to
The display part shows .
and check the display part.
Press the Mode Selection key, to set the display part to
The display part shows .
and check the display part.
repeatedly.
repeatedly.
repeatedly.
repeatedly.
Step 4 : Pressing the ON/OFF button (
When pressing the operation ON/OFF key with the direction of remote control for unit, the sound "Ding" or "Diriring" is heard
and the OPERATION ICON( diriring sound isn't heard, try again pressing the ON/OFF button.)
Step 5 : Unit operation test-run
First, Remove the battery from the remote control. Second, Re-insert the battery into the remote control. Third, Press ON/OFF key with the direction of remote control for set.
• Error Mode
1st If all lamps of indoor unit are flickering, plug out, plug in power plug again and press the ON/OFF key to retry. 2nd If the unit is not working properly or all lamps are continuously flickering after setting the option code, see if the correct option code
is set up for its model.
4-7 Samsung Electronics
)
) lamp of the display is flickering at the same time, then the input of option is completed. (If the
PCB option code input method(cont.)
4-1-1-3 example : 660157022E
AVXWNH666C6/ND666N6666
Step 1 : Enter the Option Setup mode.
st
1
2
3
Take out the batteries of remote control.
nd
Press the temperature button simultaneously and
insert the battery again.
rd
Make sure the remocon display shown as .
Troubleshooting
Step 2 : Enter the Option Setup mode and select your option according to the following procedure.
Feature Display
1
Setting Option SEG1.
button to set the display panel to .
button to set the display panel to .
button.
button to set the display panel to .
repeatedly.
repeatedly.
repeatedly.
3
1,4 2,5
Push the Every time you push the button, the display panel reads
. . .
2
Setting Option SEG2. Push the Every time you push the button, the display panel reads
. . .
3
Change it into the set display of Option SEG3 and SEG4 with the
4
Setting Option SEG3. Push the Every time you push the button, the display panel reads
. . .
5
Samsung Electronics 4-8
Setting Option SEG4. Push the Every time you push the button, the display panel reads
. . .
button to set the display panel to .
repeatedly.
Troubleshooting
Feature Display
6
Change it into the set display of Option SEG5 and SEG6 with the button.
7
Setting Option SEG5. Push the Every time you push the button, the display panel reads
. . .
button to set the display panel to .
repeatedly.
8
Setting Option SEG6. Push the Every time you push the button, the display panel reads
. . .
button to set the display panel to .
repeatedly.
6,9
7,10 8,11
12
13 14
9
Change it into the set display of Option SEG7 and SEG8 with the button.
10
Setting Option SEG7. Push the Every time you push the button, the display panel reads
. . .
button to set the display panel to .
repeatedly.
11
Setting Option SEG8. Push the Every time you push the button, the display panel reads
. . .
button to set the display panel to .
repeatedly.
12
Change it into the set display of Option SEG9 and SEG10 with
button.
the
13
Setting Option SEG9. Push the Every time you push the button, the display panel reads
. . .
button to set the display panel to .
repeatedly.
14
4-9 Samsung Electronics
Setting Option SEG10. Push the Every time you push the button, the display panel reads
. . .
button to set the display panel to .
repeatedly.
Step 3 : Upon completion of the selection, check you made right selections.
Whenever you press the
button, the set Option will be displayed.
Troubleshooting
Step 4 : Pressing the ON/OFF button (
)
When pressing the operation ON/OFF key with the direction of remote controller for unit, the sound "Ding" is heard and the
OPERATION LED lamp is flickering at the same time, then the input of option is completed. (If the "ding" sound isn't heard, try again pressing the ON/OFF button.)
Step 5 : Unit operation test-run
First, Remove the battery from the remote controller. Second, Re-insert the battery into the remote controller. Third, Press ON/OFF (
) key with the direction of remote controller for set.
• Error Mode
st
1
If all lamps of indoor unit are flickering, Plug out, plug in power plug again and press ON/OFF key to retry.
nd
2
If the unit is not working properly or all lamps are continuously flickering after setting the option code, see if the cor-
rect option code is set up for its model.
Samsung Electronics 4-10
Troubleshooting
4-1-2 Setting an indoor unit address and installation option
Set the indoor unit address and installation option with remote controller option. Set the each option separately since you cannot set the ADDRESS setting and indoor unit installation setting option at the same time.You need to set twice when setting indoor unit address and installation option.
4-1-2-1
The procedure of option setting
Entering mode for
option setting
High Temp Button
Low Temp Button
Option setting mode
Mode change
High Fan Button
Low Fan Button
Step 1. Entering mode to set option
1. Remove batteries from the remote controller.
2. Insert batteries and enter the option setting mode while pressing High Temp button and Low Temp button.
3. Check if you have entered the option setting status.
Step 2. The procedure of option setting
After entering the option setting status, select the option as listed below.
Option setting is available from SEG1 to SEG 24
• SEG1, SEG7, SEG13, SEG19 are not set as page option.
• Set the SEG2~SEG6, SEG8~SEG12 as ON status and SEG14~18, SEG20~24 as OFF status.
SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
0XXXXX1XXXXX
SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 SEG19 SEG20 SEG21 SEG22 SEG23 SEG24
2XXXXX3XXXXX
4-11 Samsung Electronics
On(SEG1~12) O(SEG13~24)
Option setting Status
1. Setting SEG2, SEG3 option Press Low Fan button(∨) to enter SEG2 value.
Press High Fan button( Each time you press the button,
2. Setting Cool mode
Press Mode button to be changed to Cool mode in the ON status.
3. Setting SEG4, SEG5 option Press Low Fan button( Press High Fan button( Each time you press the button,
4. Setting Dry mode
Press Mode button to be changed to DRY mode in the ON status.
5. Setting SEG6, SEG8 option Press Low Fan button( Press High Fan button( Each time you press the button,
6. Setting Fan mode
Press Mode button to be changed to FAN mode in the ON status.
) to enter SEG3 value.
󱈓 󱈓󱈓 will be selected in rotation.
) to enter SEG4 value.
) to enter SEG5 value.
󱈓 󱈓󱈓 will be selected in rotation.
) to enter SEG6 value.
) to enter SEG8 value.
󱈓 󱈓󱈓 will be selected in rotation.
Troubleshooting
SEG2 SEG3
SEG4
SEG6
SEG5
SEG8
7. Setting SEG9, SEG10 option Press Low Fan button( Press High Fan button( Each time you press the button,
8. Setting Heat mode
Press Mode button to be changed to HEAT mode in the ON status.
9. Setting SEG11, SEG12 option Press Low Fan button( Press High Fan button( Each time you press the button,
10. Setting Auto mode
Press Mode button to be changed to AUTO mode in the OFF status.
11. Setting SEG14, SEG15 option Press Low Fan button( Press High Fan button( Each time you press the button,
) to enter SEG9 value.
) to enter SEG10 value.
󱈓 󱈓󱈓 will be selected in rotation.
) to enter SEG11 value.
) to enter SEG12 value.
󱈓 󱈓󱈓 will be selected in rotation.
) to enter SEG14 value.
) to enter SEG15 value.
󱈓 󱈓󱈓 will be selected in rotation.
SEG9
SEG11
SEG14
SEG10
SEG12
SEG15
Samsung Electronics 4-12
Troubleshooting
Option setting Status
12. Setting Cool mode
Press Mode button to be change to Cool mode in the OFF status.
13. Setting SEG16, SEG17 option
Press Low Fan button( Press High Fan button( Each time you press the button,
14. Setting Dry mode
Press Mode button to be change to Dry mode in the OFF status.
15. Setting SEG18, SEG20 option Press Low Fan button( Press High Fan button( Each time you press the button,
16. Setting Fan mode
Press Mode button to be change to Fan mode in the OFF status.
) to enter SEG16 value.
) to enter SEG17 value.
󱈓 󱈓󱈓 will be selected in rotation.
) to enter SEG18 value.
) to enter SEG20 value.
󱈓 󱈓󱈓 will be selected in rotation.
SEG16
SEG18
SEG17
SEG20
17. Setting SEG21, SEG22 option
Press Low Fan button( Press High Fan button( Each time you press the button,
18. Setting Heat mode
Press Mode button to be change to HEAT mode in the OFF status.
19. Setting SEG23, SEG24 mode Press Low Fan button( Press High Fan button( Each time you press the button,
) to enter SEG21 value.
) to enter SEG22 value.
󱈓 󱈓󱈓 will be selected in rotation.
) to enter SEG23 value.
) to enter SEG24 value.
󱈓 󱈓󱈓 will be selected in rotation.
Step 3. Check the option you have set
After setting option, press
¤
¤
button to check whether the option code you input is correct or not.
¤
¤
¤
¤
¤
¤
SEG21
SEG23
¤
SEG22
SEG24
Step 4. Input option
Press operation button
with the direction of remote control for set.
For the correct option setting, you must input the option twice.
Step 5. Check operation
1. Reset the indoor unit by pressing the RESET button of indoor unit or outdoor unit.
2. Take the batteries out of the remote controller and insert them again and then press the operation button.
4-13 Samsung Electronics
Troubleshooting
4-1-2-2
1. Check whether power is supplied or not.
2. The panel(display ) should be connected to an indoor unit to receive option.
3. Before installing the indoor unit, assign an address to the indoor unit according to the air
4. Assign an indoor unit address by wireless remote controller.
Option No. : 0AXXXX-1XXXXX-2XXXXX-3XXXXX
Explanation PAGE MODE Setting Main address
Controller
Indication
and Details
Setting an indoor unit address (MAIN/RMC)
- When the indoor unit is not plugged in, there should be additional power supply in the
indoor unit.
conditioning system plan.
- The initial setting status of indoor unit ADDRESS(MAIN/RMC) is "0A0000-100000-200000-300000".
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Remote
Display
100-digit of indoor
unit address
Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details
0
0A
1
No Main
address
0~9 Main address setting mode
10-digit of indoor
100
-digit
0~9 10-digit 0~9
Indoor Unit
1(L) 2(N)
The unit digit of an
unit
F2 F1
indoor unit
A unit
digit
Option SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
Explanation PAGE Setting RMC address Group channel(*16) Group address
Remote
Controller
Display
Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details
Indication
and Details
• When “A”~”F” is entered to SEG5~6, the indoor unit MAIN ADDRESS is not changed.
• If you set the SEG 3 as 0, the indoor unit will maintain the previous MAIN ADDRESS even if you input the option value of SEG5~6.
• If you set the SEG 9 as 0, the indoor unit will maintain previous RMC ADDRESS even if you input the option value of SEG11~12.
1
0 No RMC address
RMC address
1
setting mode
RMC1 0~2 RMC2 0~F
Samsung Electronics 4-14
Troubleshooting
4-1-2-3 Setting an indoor unit installation option(suitable for the condition of each installation location)
1. Check whether power is supplied or not.
- When the indoor unit is not plugged in, there should be additional power supply in the
indoor unit.
2. The panel(display ) should be connected to an indoor unit to receive option.
3. Set the installation option according to the installation condition of an air conditioner.
- The default setting of an indoor unit installation option is “02000-100000-200000-300000”.
- Individual control of a remote controller(SEG20) is the function that controls an indoor unit
individually when there is more than one indoor unit.
4. Set the indoor unit option by wireless remote controller.
SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
0 2 RESERVED Exterior temperature sensor Central control FAN RPM compensation
SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
1 Drain pump Hot water heater Electronic heater
SEG13 SEG14 SEG15 SEG16 SEG17 SEG18
2 External control
SEG19 SEG20 SEG21 SEG22 SEG23 SEG24
3
Individual control of
a remote controller
External control
output
Heating setting
compensation
S-Plasma ion Buzzer
EEV opening of an indoor
unit stopped during oil
return or Defrost operation.
Opening the electronic
expansion valve
- Human sensor
Indoor Unit
1(L) 2(N)
Master / Slave
Number of hours using
lter
F2 F1
1WAY/2WAY/4WAY MODEL : Drain pump(SEG8) will be set to 'USE + 3minute delay' even if the drain pump is set to 0. 1 WAY/2WAY/4WAY,DUCT MODEL : Number of hours using lter(SEG18) will be set to '1000hour' even if the SEG18 is set to exept for 2 or 6. If you input a number other than 0~4 of the individual control of the indoor unit(SEG20), the indoor is set as "indoor 1".
Option No. : 02XXXX-1XXXXX-2XXXXX-3XXXXX
Option
Explanation
Remote
Controller
Display
Indication
and Details
Option
Explanation
Remote
Controller
Display
Indication
and Details
SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
PAGE MODE
Indication
Indication
Details
Indication
02
SEG7 SEG8 SEG9 SEG10 SEG11 SEG12
PAGE Use of drain pump
Details
Indication
1
Details
Details 0 Disuse 0 Disuse 0 Disuse 0 0 0 slave 1 Use 1 Use 1 Use 1 80 1 master
Use +
3minute
2
delay
Use of robot
cleaning
Indication
Use of hot water
Indication
Details
0 Disuse 0 Disuse 0 Disuse
1 Use 1 Use 1 Use 2
heater
Details
Use of external
temperature sensor
Indication
Use of electronic
Indication
Details
heater
Details
Use of central control
Indication
Opening the electronic
expansion valve of an indoor unit
when heating operation stops.
Indication
Details
Details
Indication
Indication
FAN RPM
compensation
Details
0 Disuse 1
Master / Slave
RPM
compensation
High ceiling
KIT
Details
4-15 Samsung Electronics
Troubleshooting
Option
Explanation
Remote
Controller
Display
Indication
and Details
Option
Explanation
Remote
Controller
Display
Indication
and Details
SEG13 SEG14 SEG15 SEG16 SEG17 SEG18
PAG E
Indication
Indication
Details
2
SEG19 SEG20 SEG21 SEG22 SEG23 SEG24
PAG E
Details
3
Use of external
control
Indication
0 Disuse 0
1
2
Individual control of
a remote controller
Indication
channel 1
0 or 1
channel 2
2 3
channel 3 channel 4
4
Details
ON/OFF
Control
OFF
Control
Details
Setting the output of external control
Indication
Indication
Details
Thermo
on
Operation
1
on
Heating setting
compensation
Details 0 Disuse 1 2°C 2 5°C
S-Plasma ion Buzzer control
Indication
EEV opening of an
indoor unit stopped
during oil return or
defrost operation.
Indication
Details
Indication
0
Disuse 0
1
1
Use
Details
0 150 step 8 Disuse
1 0 step 9 Use
2
3
Indication
Details
Mixed operation control1/
Use buzzer
Mixed operation control1/
Disuse of buzzer
Mixed operation control2/
Use buzzer
Mixed operation control2/
Disuse of buzzer
Details
Number of hours
Indication
Indication
using lter
Details
2
1000 Hour
6
2000 Hour
Human sensor
Details
4-1-2-4
Changing a particular option
You can change each digit of set option.
Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
Explanation PAGE MODE
Remote
Controller
Display
Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details
Indication
and Details
• When changing a digit of an indoor unit address setting option, set the SEG3 as ‘A’.
• When changing a digit of indoor unit installation option, set the SEG3 as ‘2’.
Ex) When setting the 'buzzer control' into disuse status.
0D
Option
Explanation PAGE MODE
Indication 0 D 2 1 7 1
SEG1 SEG2 SEG3 SEG4 SEG5 SEG6
The option mode you
want to change
Option
mode
0~F
The option mode
you want to
change
The tens’ digit of an option SEG you will
change
Tens’ digit
of SEG
The tens’ digit of an option SEG you will
change
0~9
The unit digit of an
option SEG you will
change
Unit digit
of SEG
The unit digit of
an option SEG you
0~9
will change
The changed value
The
changed
value
The changed value
0~F
Samsung Electronics 4-16