SAMSUNG NB17ASHS_EDC Service Manual Disassembly & Reassembly

NB17A*/NB19A* 3-1
3 Disassembly and Reassembly
This section of the service manual describes the disassembly and reassembly procedures for the NB17A*/NB19A* monitor.
WARNING: This monitor contains electrostatically sensitive devices. Use caution when handling
these components.
3-1 Disassembly
Cautions : 1. Disconnect the monitor from the power source before disassembly.
3. R/Cover opening jig : BH81-00001A
1. Place monitor face down on cushioned table. Remove 2 screws from grip on the stand and remove signal cable. (CAUTION : Remove screw grip don’t on the stand than fall the stand from the top side of the foot.)
2. Remove front cover and remove back cover.
3. Remove 2 screws shield TCO and remove 1 screw shield power.
4. Remove casket tape and disconnect function cable, inverter cable.
(NB17A*) (NB19A*)
3 Disassembly and Reassembly
3-2 NB17A*/NB19A*
3-2 Replacement Order of Lamp Assemblies
1. Remove 2 screws from LCD module. (top & bottom)
Note : Always clear the work table
before operation.
2. Slide out the lamp unit. Do not use excessive force.
5. Disconnect LVDS cable and remove 4 screws from the shield. (the coner of the shield 4 screws)
6. Lift up shield from the panel.