1-2 Samsung Electronics
(a) Do not operate or allow the oven to be
operated with the door open.
(b) Make the following safety checks on
all ovens to be serviced before activating the magnetron or other microwave source, and make repairs as necessary: (1) Interlock operation, (2) proper door closing, (3) seal and sealing surfaces (arcing,
wear, and other damage),
(4) damage to or loosening of hinges
and latches,
(5) evidence of dropping or abuse.
(c) Before turning on microwave power
for any service test or inspection within the microwave generating compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment, integrity, and connections.
(d) Any defective or misadjusted
components in the interlock, monitor, door seal, and microwave generation and transmission systems shall be repaired, replaced, or adjusted by procedures described in this manual before the oven is released to the owner.
(e) A Microwave leakage check to verify
compliance with the Federal performance standard should be performed on each oven prior to release to the owner.
PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO A VOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY
Samsung Electronics
1. Precaution
1-1 Safety precautions ( )
1-1
1. All repairs should be done in accordance with the procedures described in this manual. This product complies with Federal Performance Standard 21 CFR Subchapter J (DHHS).
2. Microwave emission check should be performed to prior to servicing if the oven is operative.
3. If the oven operates with the door open : Instruct the user not to operate the oven and contact the manufacturer and the center for devices and radiological health immediatly.
4. Notify the Central Service Center if the microwave leakage exceeds 5 mW/cm
2
5. Check all grounds.
6. Do not power the MWO from a "2-prong" AC cord. Be sure that all of the built-in protective devices are replaced. Restore any missing protective shields.
7. When reinstalling the chassis and its assemblies, be sure to restore all protective devices, including: nonmetallic control knobs and compartment covers.
8. Make sure that there are no cabinet openings through which people--particularly children--might insert objects and contact dangerous voltages. Examples: Lamp hole, ventilation slots.
9. Inform the manufacturer of any oven found to have emmission in excess of 5 mW/cm2, Make repairs to bring the unit into compliance at no cost to owner and try to determine cause. Instruct owner not to use oven until it has been brought into compliance.
CENTRAL SERVICE CENTER
10. Service technicians should remove their watches while repairing an MWO.
11. To avoid any possible radiation hazard, replace parts in accordance with the wiring diagram. Also, use only the exact replacements for the following parts: Primary and secondary interlock switches, interlock monitor switch.
12. If the fuse is blown by the Interlock Monitor Switch: Replace all of the following at the same time: Primary, door sensing, interlock monitor switch and power relay. The correct adjustment of these switches is described elsewhere in this manual. Make sure that the fuse has the correct rating for the particular model being repaired.
13. Design Alteration Warning: Use exact replacement parts only, i.e., only those that are specified in the drawings and parts lists of this manual. This is especially important for the Interlock switches, described above. Never alter or add to the mechanical or electrical design of the MWO. Any design changes or additions will void the manufacturer's warranty.10.Always unplug the unit's AC power cord from the AC power source before attempting to remove or reinstall any component or assembly.
14. Never defeat any of the B+ voltage interlocks. Do not apply AC power to the unit (or any of its assemblies) unless all solid-state heat sinks are correctly installed.
15. Some semiconductor ("solid state") devices are easily damaged by static electricity. Such components are called Electrostatically Sensitive Devices (ESDs). Examples include integrated circuits and field-effect transistors.
Immediately before handling any semiconductor components or assemblies, drain the electrostatic charge from your body by touching a known earth ground.
Follow these special safety precautions. Although the microwave oven is completely safe during ordinary use, repair work can be extremely hazardous due to possible exposure to microwave radiation, as well as potentially lethal high voltages and currents.
Samsung Electronics
16. Always connect a test instrument's ground lead to the instrument chassis ground before
connecting the positive lead; always remove the instrument's ground lead last.
17. When checking the continuity of the witches or transformer, always make sure that the power is OFF, and one of the lead wires is disconnected.
18. Components that are critical for safety are indicated in the circuit diagram by shading, or .
19. Use replacement components that have the same ratings, especially for flame resistance and dielectric strength specifications. A replacement part that does not have the same safety characteristics as the original might create shock, fire or other hazards.
1. High Voltage Warning Do not attempt to measure any of the high voltages--this includes the filament voltage of the magnetron. High voltage is present during any cook cycle.
Before touching any components or wiring, always unplug the oven and discharge the high voltage capacitor (See Figure 1-1)
2. The high-voltage capacitor remains charged about 30 seconds after disconnection. Short the negative terminal of the high-voltage capacitor to the oven chassis. (Use a screwdriver.)
3. High voltage is maintained within specified limits by close-tolerance, safety-related components and adjustments. If the high voltage exceeds the specified limits, check each of the special components.
1-2
Pretaution
1-2 Special Servicing Precautions (Continued)
1-3 Special High Voltage Precautions
Fig. 1-1. Discharging the High Voltage Capacitor
Samsung Electronics
2. Specifications
2-1 Table of Specifications
2-1
MODEL MW5780H
ITEM TIMER 99 MINUTES 99 SECONDS POWER SOURCE 120V/60HZ, AC POWER CONSUMPTION MICROWAVE : 1,200W OUTPUT POWER FROM 80W TO 800W (10 LEVEL POWER)
(IEC-705 TEST PROCEDURE) OPERATING FREQUENCY 2,450MHz MAGNETRON OM75SH(31)ESS COOLING METHOD COOLING FAN MOTOR OUTSIDE DIMENSIONS 20
11/32
(W) x 11
11/32
(H) x 14
5/8
(D) NET WEIGHT 33.1 lbs. SHIPPING WEIGHT 37.5 lbs
2-2 Comparison Chart
MORE/LESS ­AUTO REHEAT ­AUTO DEFROST ­TIME COOK ­POWER LEVEL O
CUSTOM COOK O MEMORY O CHILD LOCK ­CLOCK O SOUND O
Samsung Electronics
Power Level Selection Button
Clock Start Button
Canel Button
Number Key Button
Start Button
1 2 3 4 5
Start
321 654 987
0
Clock Sound
Power Level
Cancel
MW5780H
3. Operating Instructions
3-1 Control Panel
3-1
3-2 Features & External Views
Door
Ventilation Holes Light
Safety Interlock Holes
Control Panel
Open Door Push Button
Guide Roller
Glass Plate
Door Latches
517mm
369mm
297.3mm
216.4mm
317.4mm
4. Disassembly and Reassembly
4-1 Replacement of Magnetron, Motor Assembly and Lamp
Samsung Electronics 4-1
Remove the magnetron including the shield case, permanent magnet, choke coils and capacitors (all of which are contained in one assembly).
1. Disconnect all lead wires from the magnetron and lamp.
2. Remove the air cover.
3. Remove screws securing the magnetron to the wave guide.
4. Take out the magnetron very carefully.
5. Remove screws from the back panel.
6. Take out the fan motor.
7. Remove the oven lamp by pulling out from hole of air cover.
NOTE1: When removing the magnetron, make
sure that its antenna does not hit any adjacent parts, or it may be damaged.
NOTE2: When replacing the magnetron, be sure
to remount the magnetron gasket in the correct position and make sure the gasket is in good condition.
1. Discharge the high voltage capacitor.
2. Disconnect all the leads.
3. Remove the mounting bolts.
4. Reconnect the leads correctly and firmly.
4-2 Replacement of High Voltage Transformer
Lamp
Cover Air
Magnetron
H. V. Trans
H. V. Capacitor
Thermo S/W
Fan Motor
Screw
H. V. Trans
Bolts