1. Precaution
3. Operating Instructions
4. Disassembly and Reassembly
5. Alignment and Adjustments
6. Troubleshooting
7. Exploded Views and Parts List
8. PCB Diagrams
9. Schematic Diagrams
Samsung Electronics
(a) Do not operate or allow the oven to be
operated with the door open.
(b) Make the following safety checks on
all ovens to be serviced before activating the magnetron or other microwave source, and make repairs as necessary: (1) Interlock operation, (2) proper door closing, (3) seal and sealing surfaces (arcing,
wear, and other damage),
(4) damage to or loosening of hinges
and latches,
(5) evidence of dropping or abuse.
(c) Before turning on microwave power
for any service test or inspection within the microwave generating compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment, integrity, and connections.
(d) Any defective or misadjusted
components in the interlock, monitor, door seal, and microwave generation and transmission systems shall be repaired, replaced, or adjusted by procedures described in this manual before the oven is released to the owner.
(e) A Microwave leakage check to verify
compliance with the Federal performance standard should be performed on each oven prior to release to the owner.
PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY
1. Precaution
1-1 Safety precautions ( )
Samsung Electronics 1-1
Follow these special safety precautions. Although the microwave oven is completely safe during ordinary use, repair work can be extremely hazardous due to possible exposure to microwave radiation, as well as potentially lethal high voltages and currents.
1. All repairs should be done in accordance with the procedures described in this manual. This product complies with Federal Performance Standard 21 CFR Subchapter J (DHHS).
2. Microwave emission check should be performed to prior to servicing if the oven is operative.
3. If the oven operates with the door open : Instruct the user not to operate the oven and contact the manufacturer and the center for devices and radiological health immediatly.
4. Notify the Central Service Center if the microwave leakage exceeds 5 mW/cm
2
5. Check all grounds.
6. Do not power the MWO from a "2-prong" AC cord. Be sure that all of the built-in protective devices are replaced. Restore any missing protective shields.
7. When reinstalling the chassis and its assemblies, be sure to restore all protective devices, including: nonmetallic control knobs and compartment covers.
8. Make sure that there are no cabinet openings through which people--particularly children--might insert objects and contact dangerous voltages. Examples: Lamp hole, ventilation slots.
9. Inform the manufacturer of any oven found to have emmission in excess of 5 mW/cm2, Make repairs to bring the unit into compliance at no cost to owner and try to determine cause. Instruct owner not to use oven until it has been brought into compliance.
CENTRAL SERVICE CENTER
10. Service technicians should remove their watches while repairing an MWO.
11. To avoid any possible radiation hazard, replace parts in accordance with the wiring diagram. Also, use only the exact replacements for the following parts: Primary and secondary interlock switches, interlock monitor switch.
12. If the fuse is blown by the Interlock Monitor Switch: Replace all of the following at the same time: Primary, door sensing switch and power relay, as well as the Interlock Monitor Switch. The correct adjustment of these switches is described elsewhere in this manual. Make sure that the fuse has the correct rating for the particular model being repaired.
13. Design Alteration Warning: Use exact replacement parts only, i.e., only those that are specified in the drawings and parts lists of this manual. This is especially important for the Interlock switches, described above. Never alter or add to the mechanical or electrical design of the MWO. Any design changes or additions will void the manufacturer's warranty.10.Always unplug the unit's AC power cord from the AC power source before attempting to remove or reinstall any component or assembly.
14. Never defeat any of the B+ voltage interlocks. Do not apply AC power to the unit (or any of its assemblies) unless all solid-state heat sinks are correctly installed.
15. Some semiconductor ("solid state") devices are easily damaged by static electricity. Such components are called Electrostatically Sensitive Devices (ESDs). Examples include integrated circuits and field-effect transistors.
Immediately before handling any semiconductor components or assemblies, drain the electrostatic charge from your body by touching a known earth ground.
16. Always connect a test instrument's ground lead to the instrument chassis ground before connecting the positive lead; always remove the instrument's ground lead last.
17. When checking the continuity of the witches or transformer, always make sure that the power is OFF, and one of the lead wires is disconnected.
18. Components that are critical for safety are indicated in the circuit diagram by shading, or .
19. Use replacement components that have the same ratings, especially for flame resistance and dielectric strength specifications. A replacement part that does not have the same safety characteristics as the original might create shock, fire or other hazards.
1. High Voltage Warning Do not attempt to measure any of the high voltages--this includes the filament voltage of the magnetron. High voltage is present during any cook cycle.
Before touching any components or wiring, always unplug the oven and discharge the high voltage capacitor (See Figure 1-1)
2. The high-voltage capacitor remains charged about 30 seconds after disconnection. Short the negative terminal of the high-voltage capacitor to the oven chassis. (Use a screwdriver.)
3. High voltage is maintained within specified limits by close-tolerance, safety-related components and adjustments. If the high voltage exceeds the specified limits, check each of the special components.
1-2
Pretaution
Samsung Electronics
1-2 Special Servicing Precautions (Continued)
1-3 Special High Voltage Precautions
Fig. 1-1. Discharging the High Voltage Capacitor
2. Specifications
2-1 Table of Specifications
Samsung Electronics 2-1
MODEL MW5490W / MW5491G
ITEM
TIMER 99 MINUTES 99 SECONDS
POWER SOURCE 120V/60HZ, AC
POWER CONSUMPTION MICROWAVE : 1,450W
OUTPUT POWER FROM 100W TO 1000W (10 LEVEL POWER)
(IEC-705 TEST PROCEDURE)
OPERATING FREQUENCY 2,450MHz
MAGNETRON OM75PH(31)ESS
COOLING METHOD COOLING FAN MOTOR
OUTSIDE DIMENSIONS 20
11/32
(W) x 11
11/16
(H) x 14
11/16
(D)
NET WEIGHT 35.3 lbs.
3-1 Samsung Electronics
Auto Reheat Button
Sets type of dish to be reheated.
One Minute + Button
Press once for every minute of cooking at High power.
Auto Defrost Button
Sets weight of food to be defrosted.
Power Level Selection Button
Sets power to level other than high.
Clock Button
Sets current time.
Pause/Canel Button
Press to pause oven ro correct a mistake.
Instant Cook Button
Instant setting to cook popular foods.
Number Key Button
Sets cooking times or amounts.
More/Less Button
Inscreases to decreases cooking time.
Start Button
Press to start cooking
Kitchen Timer Button
Auto
Defrost
Auto
Reheat
Pause
Cancel
Start
Clock
Kitchen
Timer
One Minute +
Popcorn
Diet Cook
Frozen Dinner
1
2
3
4
5
6
7
8
9
0
More/Less
Power Level
Baby Food
Potato
Fresh
Vegetable
3. Operating Instructions
3-1 Control Panel
3-2 Features & External Views
Door
Ventilation Holes
Light
Safety Interlock Holes
Control Panel
Open Door Push Button
Guide Roller
Glass Tray
Door Latches
517mm
370mm
297mm
215mm
379mm
4. Disassembly and Reassembly
4-1 Replacement of Magnetron, Motor Assembly and Lamp
Samsung Electronics 4-1
Remove the magnetron including the shield case, permanent magnet, choke coils and capacitors (all of which are contained in one assembly).
1. Disconnect all lead wires from the magnetron and lamp.
2. Remove the air cover.
3. Remove screws securing the magnetron to the wave guide.
4. Take out the magnetron very carefully.
5. Remove tow screws from the back panel of fan motor assembly.
6. Take out the fan motor assembly.
7. Remove the oven lamp by pulling out from hole of air cover.
NOTE1: When removing the magnetron, make
sure that its antenna does not hit any adjacent parts, or it may be damaged.
NOTE2: When replacing the magnetron, be sure to
remount the magnetron gasket in the correct position and make sure the gasket is in good condition.
1. Discharge the high voltage capacitor.
2. Disconnect all the leads.
3. Remove the mounting bolts.
4. Reconnect the leads correctly and firmly.
4-2 Replacement of High Voltage Transformer
Lamp
Cover Air
Magnetron
H. V. Trans
H. V. Capacitor
Thermo S/W
Fan Motor
Screw
Loading...