Any Modification of Specification is not allowed without SEC's Permission.
NOTE :
LCD
LCD
: LTA520HA02
: LTA520HA02
APPROVAED BY
Product Planning Group3, LCD Business
Samsung Electronics Co., LTD.
DATE
23.Jan.2007
PREPARED BY
DATE
23.Jan.2007
1/ 28Page05-000-G-070123Doc. NoLTA520HA02MODEL
Page 2
Contents
Revision History -------------------------------------------------------------------------------------------- (3)
General Description --------------------------------------------------------------------------------------- (4)
General Information --------------------------------------------------------------------------------------- (4)
1. Absolute Maximum Ratings -------------------------------------------------------------------------- (5)
10. General Precaution ----------------------------------------------------------------------------------- (26)
10.1 Handling
10.2 Storage
10.3 Operation
10.4 Operation Condition Guide
10.5 Others
2/ 28Page05-000-G-070123Doc. NoLTA520HA02MODEL
Page 3
* Revision History
Date
Jan
23,
2007
Rev.
No
SummaryPage
First issuedall000
3/ 28Page05-000-G-070123Doc. NoLTA520HA02MODEL
Page 4
General Description
Description
LTA520HA02 is a color active matrix liquid crystal display (LCD) that uses amorphous
silicon TFT(Thin Film Transistor) as switching components. This model is composed of a
TFT LCD panel, a driver circuit and a back light unit. The resolution of a 52.0“ is 1920 x
1080 and this model can display up to 1.07 billion colors with wide viewing angle of 89° or
higher in all directions. This panel is intended to support applications to provide a excellent
performance for Flat Panel Display such as Home-alone Multimedia TFT-LCD TV, Display
terminals for AV application products, and High Definition TV (HDTV).
Features
RoHS compliance (Pb-free)
High contrast ratio, high aperture ratio, fast response time
SPVA(Super Patterned Vertical Align) mode
Wide viewing angle (±178°)
High speed response
Wide UXGA (1920 x 1080 pixels) resolution (16:9)
Low Power consumption
Direct Type 24 CCFTs(Cold Cathode Fluorescent Tube)
DE(Data Enable) mode
LVDS (Low Voltage Differential Signaling) interface (2pixel/clock)
General Information
Module Size
1226.0(H
Haze 44% , Hard-coating (3H)Surface Treatment
RGB vertical stripePixel Arrangement
58.5(D
Normally BlackDisplay Mode
) x 719.2(V
TYP
MAX
UnitSpecificationItems
)
TYP
)
mm
g21,000(Max.)Weight
mm0.6(H) x 0.2(W)*3Pixel Pitch
mm1152.0(H) x 648.0(V)Active Display Area
colors10 bit – 1.07BDisplay Colors
pixel1920 x 1080Number of Pixels
cd/㎡500 (Typ.)Luminance of White
Note
±1.0mm
4/ 28Page05-000-G-070123Doc. NoLTA520HA02MODEL
Page 5
1. Absolute Maximum Ratings
If the condition exceeds maximum ratings, it can cause malfunction or unrecoverable
damage to the device.
NoteUnitMax.Min.SymbolItem
Power Supply Voltage
Storage temperature
Glass surface
Center
DD
STG
OPR
temperature
(Operation)
T. Uniformity
Shock ( non - operating )
Vibration ( non - operating )
Note (1) Ta= 25 ± 2 °C
(2) Temperature and relative humidity range are shown in the figure below.
a. 90 % RH Max. (Ta ≤ 39 °C)
b. Relative Humidity is 90% or less. (Ta > 39 °C)
c. No condensation
(3) 11ms, sine wave, one time for ±X, ±Y, ±Z axis
(4) 10-300 Hz, Sweep rate 10min, 30min for X,Y,Z axis
△T
nop
nop
60-20T
500T
10-
30
℃
℃
℃
(1)V13.0GND-1V
(2)
(2),(5)
(3)G-S
(4)G1.5-V
Fig. Temperature and Relative humidity range
5/ 28Page05-000-G-070123Doc. NoLTA520HA02MODEL
Page 6
(5) Definition of test point
5mm
5mm
12
5
○
LCD Module (Active)
3
℃
△T should be less than 10
T
: Temperature of the center of the glass surface (Test point 5)
OPR
(△T = | T
OPR–TMAX
T1~ T4 : Temperature of each edge of the glass surface
T
: The highest temperature of the glass surface
MAX
4
| )
6/ 28Page05-000-G-070123Doc. NoLTA520HA02MODEL
Page 7
2. Optical Characteristics
The optical characteristics should be measured in a dark room or equivalent.
Measuring equipment : TOPCON BM-5A, SR-3, RD80s, Eldim EZ-Contrast
Contrast Ratio
(Center of screen)
Response
Time
Luminance of White
(Center of screen)
Color
Chromaticity
(CIE 1931)
Rising
Falling
Red
Green
Blue
White
(Ta = 25 ± 2°C, VDD=12.0V, fv= 60Hz, f
TgG-to-G
L
Rx
Normal
θL,R=0
θU,D=0
Viewing
Angle
TYP.
-0.03
0.667
0.315Ry
0.200Gx
0.650Gy
0.142Bx
0.080By
.0282Wx
0.284Wy
=74.25MHz, Dim = Max Dim )
DCLK
-20001200C/R
SR-3
1810-Tr
86-Tf
msec
RD80s
-8-
2
-500400Y
TYP.
+0.03
cd/m
SR-3
(7),(8)
SR-3
NoteUnitMax.Typ.Min.ConditionSymbolItem
(3)
(5)
(6)
θ
Hor.
Viewing
Angle
Ver.
L
R
U
D
Brightness Uniformity
(9 Points)
uni
Note (1) Test Equipment Setup
The measurement should be executed in a stable, windless and dark room between
40min and 60min after lighting the back light at the given temperature for stabilization
of the back light. This should be measured in the center of screen.
Dimming Condition : Max Dimming
Environment condition : Ta = 25 ± 2 °C
C/R≥10
%-90--Color Gamut
K-10000--Color Temperature
(7)
SR-3
(7)
SR-3
-8975
-8975θ
Degree
-8975θ
(8)
EZ-Contrast
-8975θ
%25--B
(4)
BM-5A
7/ 28Page05-000-G-070123Doc. NoLTA520HA02MODEL
Page 8
Field Photo detector
2°SR-3
2°RD80s
TFT - LCD Module
Note (2) Definition of test point
3209601600
Photo detector
Field
SR-3 : 50㎝
RD80s : 50㎝
LCD Panel
The center of the screen
180
540
900
Note (3) Definition of Contrast Ratio (C/R)
: Ratio of gray max (Gmax) & gray min (Gmin) at the center point ⑤ of the panel
C
/
R =
⑨
⑥
G
max
G
min
Gmax : Luminance with all pixels white
Gmin : Luminance with all pixels black
⑧
⑤④
⑦
①②③
Active Area
Test Point
8/ 28Page05-000-G-070123Doc. NoLTA520HA02MODEL
Page 9
Note (4) Definition of 9 points brightness uniformity
Buni
BB
=∗
(max min)
100
B
−
max
Bmax : Maximum brightness
Bmin : Minimum brightness
Note (5) Definition of Response time : Sum of Tr, Tf
Display data
Optical Instruments
Response
100%
Black (data off)
T
R
White (data on)
90%
10%
0%
White (data off)
T
F
TIME
Note (6) Definition of Luminance of White : Luminance of white at center point ⑤
Note (7) Definition of Color Chromaticity (CIE 1931)
Color coordinate of Red, Green, Blue & White at center point ⑤
Note (8) Definition of Viewing Angle
: Viewing angle range (C/R ≥10)
9/ 28Page05-000-G-070123Doc. NoLTA520HA02MODEL
Page 10
3. Electrical Characteristics
3.1 TFT LCD Module
The connector for display data & timing signal should be connected.
Ta = 25°C ± 2 °C
NoteUnitMax.Typ.Min.SymbolItem
Voltage of Power Supply
Current
(a) Black
of Power
DD
I
DD
Supply
Vsync Frequency
Hsync Frequency
Main Frequency
Rush Current
V
H
DCLK
RUSH
Note (1) The ripple voltage should be controlled under 10% of VDD.
V=60Hz, fDCLK = 74.25MHz, V
(2) f
= 12.0V, DC Current.
DD
(3) Power dissipation check pattern (LCD Module only)
(4) For each LVDS channel
a) Black Pattern b) White Pattern c) N-Pattern
(1)V131211V
mA-1000mA-1300-(b) White
(2),(3)
mA14001200-(c) N-Pattern
Hz62.060.048.0f
kHz75.067.560.0f
(4)MHz77.574.2565f
(5)A5--I
(5) Measurement Conditions
100%
90%
10%
GND
Rush Current I
can be measured when T
RUSH
T
RUSH
=470㎲
. is 470㎲.
RUSH
V
DD
10 / 28Page05-000-G-070123Doc. NoLTA520HA02MODEL
Page 11
3.2 Back Light Unit
The back light unit contains 24 direct-lighting type CCFTs ( Cold Cathode Fluorescent
Tube ). The characteristics of lamps are shown in the following tables.
Ta=25 ± 2°C
NoteUnitMax.Typ.Min.SymbolItem
Lamp Current
Lamp Voltage
Note (1) It is defined as the time to take until the brightness reduces to 50% of its original value.
[Operating condition : Ta = 25±2℃, For single lamp only. ]
L
L
Socket
HOT 1
HOT 2
mArms7.06.04.0I
Vrms-1620-V
Socket
HOT 1
HOT 2
LCD
Inverter
Inverter
Module
(1)Hour--30,000HrOperating Life Time
HOT 23
HOT 24
HOT 23
HOT 24
11 / 28Page05-000-G-070123Doc. NoLTA520HA02MODEL
Page 12
3.3 Inverter Input Condition & Specification
ConditionsSymbolItems
Specifications
NoteUnit
Max.Typ.Min.
Input
Voltage
Input
Current
Lamp
Current
Frequency
Backlight
On/Off
Dimming
Control
I
RUSH
LAMP
V
O
DIM
Vin=24.0V
Vdim=3.3V
Ta=25±2 °CV252423-Vin
Initial Turn-onA15--
mArms6.56.05.5Vdim=3.3 VI
kHz51.048.546.0Vin=24.0 VF
-
-
5.25-2.4Vin=24.0 VON
-V
0.8--0.3Vin=24.0 VOFF
3.3--Max Lum
-V
--0.0Min. Lum
12 / 28Page05-000-G-070123Doc. NoLTA520HA02MODEL
Page 13
4. Block Diagram
CONTROL PCB
USER CONNECTORTIMING CONTROLLER
DC/DC STEP DOWN
DC/DC CONVERTOR
(AV
DD/VDD/VON/VOFF
DATA
CONTROL
VIN(12.0V)
AV
VON/V
V
COM
Y VOLTAGE
VDD(3.3V)
VDD(2.5V)
DD
OFF
)
GAMMA-GENERATOR
V
-GENERATOR
COM
R-STRING + FB
SSC
MEMORY(DCC)
FPC
FPC
SOURCE
PCB
SOURCE
PCB
DATA DRIVER
IC
LTA520HA
PANEL
DATA DRIVER
IC
GATE DRIVER
IC
13 / 28Page05-000-G-070123Doc. NoLTA520HA02MODEL
Page 14
5. Input Terminal Pin Assignment
5.1. Input Signal & Power Connector : FI-RE51S-HF (JAE)
DescriptionSymbolPinDescriptionSymbolPin
26DC 12VPower1
27DC 12VPower2
28DC 12VPower3
29DC 12VPower4
30DC 12VPower5
31GNDGND6
32GNDGND7
33GNDGND8
34GNDGND9
35Odd LVDS Signal -RO[0]N10
36Odd LVDS Signal +RO[0]P11
37Odd LVDS Signal -RO[1]N12
38Odd LVDS Signal +RO[1]P13
39Odd LVDS Signal -RO[2]N14
40Odd LVDS Signal +RO[2]P15
41GNDGND16
Even LVDS Signal +RE[0]P
Even LVDS Signal -RE[1]P
Even LVDS Signal +RE[1]P
Even LVDS Signal -RE[2]P
Even LVDS Signal + RE[2]P
GNDGND
Even LVDS Signal -ROCLKEven LVDS Signal +ROCLK+
GNDGND
Even LVDS Signal -RO[3]N
Even LVDS Signal +RO[3]P
Even LVDS Signal -RO[4]N
Even LVDS Signal +RO[4]P
GNDGND
NCNC
NCNC
42Odd LVDS Signal -ROCLK-17
43Odd LVDS Signal +ROCLK+18
44GNDGND19
45Odd LVDS Signal -RO[3]N20
46Odd LVDS Signal +RO[3]P21
47Odd LVDS Signal -RO[4]N22
48Odd LVDS Signal +RO[4]P23
49GNDGND24
50Even LVDS Signal -RE[0]N25
5.5 Input Signals, Basic Display Colors and Gray Scale of Each Color
COLOR
BASIC
COLOR
GRAY
SCALE
OF
RED
GRAY
SCALE
OF
GREEN
GRAY
SCALE
OF
BLUE
DISPLAY
(8bit)
MAGENTA
DARK
↑
↓
LIGHT
DARK
↑
↓
LIGHT
DARK
↑
↓
LIGHT
DATA SIGNAL
BLUEGREENRED
G8
R8
R9
0
0
000BLUE
000BLACK
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
:
:
:
:
1
1
1
1
1
1
0
0
0
0
0
0
:
:
:::::::
:
:
0
0
0
0
0
0
0
0
0
0
0
0
:
:
:
:
0
0
0
0
0
0
00000000000BLACK
:::::::::::::::
G9
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
0
0
:
:
:
:
0
0
0
0
0
0
0
0
0
0
0
0
:
:
:
:
1
1
1
1
1
1
0
0
0
0
0
0
:
:
:
:
0
0
0
0
0
0
0000000000000000000BLACK
B7B6B5B4B3B2B1B0G7G6G5G4G3G2G1G0R7R6R5R4R3R2R1R0
::::::::::::::::::::::::
:::::::::
::::::::::::::::::::::::
:::::::::::::::::
::::::::::::::::::::::::
::::::::::::::::::::::::
GRAY
SCALE
LEVEL
B8
B9
0
1
0
1
0
1
0
1
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
1
1
1
-000000000000000000000000BLACK
0
-111111110000000000000
1
-000000001111111100000000GREEN
0
-111111111111111100000000CYAN
1
-000000000000000011111111RED
0
-111111110000000011111111
1
-000000001111111111111111YELLOW
0
-111111111111111111111111WHITE
1
R000000
0
R1000000000000000000000001
0
R2000000000000000000000010
0
:
R3~
R1020
:
R1021000000000000000011111101
0
R1022000000000000000011111110
0
R1023000000000000000011111111RED
0
G00000000000000
0
G1000000000000000100000000
0
G2000000000000001000000000
0
:
G3~
G1020
:
G1021000000001111110100000000
0
G1022000000001111111000000000
0
G1023000000001111111100000000GRE EN
0
B0000000000000000000000
0
B1000000010000000000000000
0
B2000000100000000000000000
0
:
B3~
B1020
:
1
B1021111111010000000000000000
1
B1022111111100000000000000000
1
B1023111111110000000000000000BLUE
Note) Definition of Gray :
Rn : Red Gray, Gn : Green Gray, Bn : Blue Gray (n = Gray level)
Input Signal : 0 = Low level voltage, 1 = High level voltage
18 / 28Page05-000-G-070123Doc. NoLTA520HA02MODEL
Page 19
6. Interface Timing
6.1 Timing Parameters ( DE only mode )
NOTEUnitMAX.TYP.MIN.SYMBOLITEMSIGNAL
Clock
Hsync
Vsync
Frequency
C
H
V
Active
Vertical
Display
Period
VD
Display Term
Vertical
Total
VB
Active
Horizontal
Display
Period
HD
Display Term
Horizontal
Total
H
Note) This product is DE only mode. The input of Hsync & Vsync signal does
not have an effect on normal operation.
(1) For each LVDS channel
(2) Test Point : TTL control signal and CLK at LVDS Tx input terminal in system
(3) Internal VDD = 3.3V
(1)MHz77.574.2565.01/T
-KHz75.067.560.0F
-Hz62.060.048.0F
-lines-1080-T
-lines148011251100T
-clocks-1920-T
-clocks245023002150T
19 / 28Page05-000-G-070123Doc. NoLTA520HA02MODEL
Page 20
6.2 Timing diagrams of interface signal ( DE only mode )
TV
DE
DE
DCLK
DATA
SIGNALS
TVD
TVB
TH
THD
TC
DCLK
DISPLAY
DATA
DE
TC
TCH
TDSTDH
TES
TCL
0.5
V
0.5
V
CC
0.5
V
CC
CC
20 / 28Page05-000-G-070123Doc. NoLTA520HA02MODEL
Page 21
6.3 Power ON/OFF Sequence
To prevent a latch-up or DC operation of the LCD Module, the power on/off
sequence should be as the diagram below.
0<T1≤10msec
0<T2≤50msec
0<T3≤50msec
1000msec≤T4
1000msec≤T5
(Recommend Value)
100msec≤T6
(Recommend Value)
2.4 V
T1 : VDDrising time from 10% to 90%
T2 : The time from V
T3 : The time from valid data off to V
T4 : V
off time for Windows restart
DD
to valid data at power ON.
DD
off at power Off.
DD
T5 : The time from valid data to B/L enable at power ON.
T6 : The time from valid data off to B/L disable at power Off.
The supply voltage of the external system for the Module input should be the same
as the definition of V
DD
.
Apply the lamp voltage within the LCD operation range. When the back light turns on
before the LCD operation or the LCD turns off before the back light turns off,
the display may momentarily show abnormal screen.
In case of V
= off level,
DD
please keep the level of input signals low or keep a high impedance.
T4 should be measured after the Module has been fully discharged between power off
and on period.
Interface signal should not be kept at high impedance when the power is on.
21 / 28Page05-000-G-070123Doc. NoLTA520HA02MODEL
Page 22
7. Outline Dimension (Front View)
ModelLTA520HA02Doc. No05-000-G-070123Page22 / 28
Page 23
7. Outline Dimension (Rear View)
ModelLTA520HA02Doc. No05-000-G-070123Page23 / 28
Page 24
8. PACKING
8.1 CARTON (Internal Package)
(1) Packing Form
Corrugated fiberboard box and corrugated cardboard as shock absorber
(2) Packing Method
Packing
-Pallet Box
Cushion-Foam
LCD Module
Direction be able to open it
Cushion-Foam
Pallet-Plastic
8.2 Packing Specification
LCD Packing
9ea / (Packing-
Pallet Box)
RemarkSpecificationItem
1. 207Kg / LCD (9ea)
2. 15.6 Kg / Cushion-pallet (2ea)
3. 10.5 Kg / Packing-Pallet Box (1ea)
4. Cushion-pallet Material : EPS
5. Packing-Pallet Box Material : DW4
1. Pallet weight = 10kg1Box / PalletPallet
VerticalPacking Direction
1475mm(H) x 1150mm(V) x 995mm(height)H x V x heightTotal Pallet Size
A nameplate bearing followed by is affixed to a shipped product at the specified
location on each product.
(1) Parts number : LTA520HA02
(2) Revision: Three letters
(3) Lot number : X X X X XXX XX X
Cell Position No. (In the Glass)
Glass No. (In the one Lot)
Lot No. (Glass)
Month
Year (Note1)
Product code
Line
(4) Nameplate Indication
Week code : 05 29
LTA520HA02
XXXXXXXXXXXXX
(5) Packing box attach
LTA520HA02
week
year
40mm
Revision code
Lot number
80mm
100mm
Part number
XXXX
10
Box serial number
165mm
(6) Others
1. After service part
Lamps cannot be replaced because of the narrow bezel structure.
25 / 28Page05-000-G-070123Doc. NoLTA520HA02MODEL
Page 26
10. General Precautions
10.1 Handling
(a) When the Module is assembled, it should be attached to the system firmly
using all mounting holes. Be careful not to twist and bend the Module.
(b) Because the inverter use high voltage, it should be disconnected from power
before it is assembled or disassembled.
(c) Refrain from strong mechanical shock and / or any force to the Module.
In addition to damage, this may cause improper operation or damage to the Module
and CCFT back light.
(d) Note that polarizers are very fragile and could be damage easily.
Do not press or scratch the surface harder than a HB pencil lead.
(e) Wipe off water droplets or oil immediately. If you leave the droplets for a long
time, staining or discoloration may occur.
(f) If the surface of the polarizer is dirty, clean it using absorbent cotton or soft cloth.
(g) Desirable cleaners are water, IPA(Isopropyl Alcohol) or Hexane.
Do not use Ketone type materials(ex. Acetone), Ethyl alcohol, Toluene, Ethyl acid
or Methyl chloride. It might permanent damage to the polarizer due to chemical
reaction.
(h) If the liquid crystal material leaks from the panel, it should be kept away
from the eyes or mouth . In case of contact with hands, legs or clothes, it must
be washed away with soap thoroughly.
(i) Protect the Module from static, or the CMOS Gate Array IC would be damaged.
(j) Use finger-stalls with soft gloves in order to keep display clean during the
incoming inspection and assembly process.
(k) Do not disassemble the Module.
(l) Do not pull or fold the lamp wire.
(m) Do not adjust the variable resistor located on the Module.
(n) Protection film for polarizer on the Module should be slowly peeled off just before use
so that the electrostatic charge can be minimized.
(o) Pins of I/F connector should not be touched directly with bare hands.
26 / 28Page05-000-G-070123Doc. NoLTA520HA02MODEL
Page 27
10.2 Storage
(a) Do not leave the Module in high temperature, and high humidity for a long time.
It is highly recommended to store the Module with temperature from 0 to 35℃
and relative humidity of less than 70%.
(b) Do not store the TFT- L CD Module in direct sunlight.
(c) The Module should be stored in a dark place. It is prohibited to apply sunlight or
fluorescent light in storing.
10.3 Operation
(a) No Connection or disconnect the Module in the "Power On" condition.
(b) Power supply should always be turned on/off by the "Power on/off sequence"
(c) Module has high frequency circuits. Sufficient suppression to the electromagnetic
interference should be done by system manufacturers. Grounding and shielding methods
may be important to minimize the interference.
(d) The cable between the back light connector and its inverter power supply should
be connected directly with a minimized length. A longer cable between
the back light and the inverter may cause lower luminance of lamp(CCFT) and
may require higher startup voltage(Vs).
10.4 Operation Condition Guide
(a) The LCD product should be operated under normal conditions.
(b) If the product will be used in extreme conditions such as high temperature,
humidity, display patterns or operation time etc.., It is strongly recommended
to contact SEC for Application engineering advice. Other wise, its reliability and
function may not be guaranteed. Extreme conditions are commonly found at
Airports, Transit Stations, Banks, Stock market, and Controlling systems.
27 / 28Page05-000-G-070123Doc. NoLTA520HA02MODEL
Page 28
10.5 Others
(a) Ultra-violet ray filter is necessary for outdoor operation.
(b) Avoid condensation of water. It may result in improper operation or disconnection
of electrode.
(c) Do not exceed the absolute maximum rating value. ( supply voltage variation,
input voltage variation, variation in part contents and environmental temperature,
and so on)
Otherwise the Module may be damaged.
(d) If the Module keeps displaying the same pattern for a long period of time,
the image may be "sticked" to the screen.
To avoid image sticking, it is recommended to use a screen saver.
(e) This Module has its circuitry PCB's on the rear side and should be handled
carefully in order not to be stressed.
(f) Please contact SEC in advance when you display the same pattern for a long time.
28 / 28Page05-000-G-070123Doc. NoLTA520HA02MODEL
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.